TABLE OF CONTENTS
MODEL NUMBERS……………………………………………………………………………2
UNIT PARTS & FEATURES……………………………………………………………………3
INSTALLATION DIMENSION DIAGRAM……………………………………………………4
SAFETY WARNINGS……………………………………………………………………………5
SELECTION OF INSTALLATION LOCATIONS………………………………………………6
INDOOR UNIT INSTALLATION………………………………………………………………8
OUTDOOR UNIT INSTALLATION……………………………………………………………11
TESTING………………………………………………………………………………………13
PRINCIPLE……………………………………………………………………………………15
SPECIFICATIONS………………………………………………………………………………17
WARRANTY……………………………………………………………………………………18
TECHNICAL SUPPORT
IF YOU NEED TECHNICAL SUPPORT PLEASE CALL
1-(704)504-8590
SEA BREEZE Installation Kit is recommended.
Catalog number can be located on page 17.
1
MODEL NUMBERS
Heat Pump
SYSTEM MODEL Indoor Unit 12H43ZIGX
12H43ZGX Outdoor Unit 12H43ZOGX
12,000 BTU 208-230 VAC
13 SEER
SYSTEM MODEL Indoor Unit 18H43ZIGX
18H43ZGX Outdoor Unit 18H43ZOGX
18,000 BTU 208-230 VAC
13 SEER
2
INSTALLATION DIMENSION DIAGRAM
4
SAFETY WARNINGS
z Use Copper Wires only for Power Supply.
z Risk of electric shock can cause injury or death. Disconnect all electric power
supplies before servicing or installation
z Do not use excessive torque on flare nuts during connection of the
refrigeration tubes, or service valve on discharge line may be damaged.
z Do not install indoor unit in damp or wet locations.
z Electrical installation must be done by a qualified technician according to the
instruction manual and in accordance with local electrical standards.
z Certified Power supply conductors must be used.
5