In continuing the tradition of Scott Safety’s dedication to our customers’ demanding needs, the
TRC-1 (Technical Rescue Carts) Air Carts provide an uninterrupted supply of breathing air for up
to eight users simultaneously. The TRC-1 Air Cart also features a unique air control switch that
has the ability to utilize common or isolated air sources on the left and right outlet banks. When
in isolated mode, this enables the cart to provide two separate, dedicated air sources for both a
primary work team and a rescue team.
5.5: MAXIMUM DURATION,
EXTENDED TIME
The Mobile Air Carts and
Te ch n ic a l Re s cu e C a rt s ( TR C-
1) are manufactured to be
compatible for use with the
Scott Safety high-pressure
5500 psi (5.5) cylinders.
Available in a 75-minute
duration, 5.5 cylinders
provide the maximum amount
of rated duration breathing air.
Two 75-minute 5.5 psi cylinders
provide 30 additional minutes
of rated duration air supply
(at 40 lpm) as compared to
the traditional two 60-minute
4.5 cylinders commonly used—
previously the longest-rated
duration available for portable
air sources of this kind. By
simply rotating cylinders, the
carts supply several hours
of air for multiple users at a
time, providing a compact
and ecient portable source
of breathing air ideal for
applications such as plant
maintenance operations,
confined space entry, HazMat
operations and construction
activities.
TRC-1 AIR CART
DURABLE, COMPATIBLE, DEPENDABLE
The Scott Safety TRC-1 Air Carts are equipped with:
•
Eight outlet ports which can provide an uninterrupted supply of breathing air for up to eight
respirators simultaneously
•
High-pressure inlet supply connector enables use of a high-pressure air supply such as a
compressor or cascade system
•
Air source selector switch for the ability to utilize common or isolated air sources on the left
and right outlet banks; this enables the cart to provide two separate, dedicated air sources
for both a primary work team and a rescue team utilizing cylinders and the high-pressure
inlet supply
•
Independent fail-safe-open, sealed regulators on the respirator and the auxiliary supply side
provides for independent adjustment of outlet pressures
•
Loud, aspirating end-of-service whistle alarm indicating low cylinder pressure and a loud,
pneumatic end-of-service bell indicating low-pressure condition on the auxiliary high-
pressure inlet source
•
Internal check valve to prevent manifold contamination with use of tools
•
Ability to use supply cylinders from 2216 psi to 5500 psi
•
Respirator outlet pressures adjustable between 0-125 psig
Extendable handle
with pull pin
Roll bars for added
outlet/panel protection
Auxiliary supply
outlets
Auxiliary outlet
pressure gauge
Auxiliary inlet
pressure gauge
End-of-service
alarm whistle
High-pressure
coupling nuts
Respirator inlet
pressure gauge
High-pressure
inlet supply
End-of-service
alarm bell
Regulator outlet
pressure gauge
Respirator supply
outlets
Auxiliary outlet
pressure regulator
Air source
selector switch
Respirator outlet
pressure regulator