The design of this modular cuber is the result of
years of experience and testing. Standard features
include front accessible indicator lights and on-off
switches that provide the user with fast access to
critical information and easy operational control.
When desired, optional controls can add features
like ultrasonic bin ice level sensing, seven day
programmable bin ice level setting, remote lock out
This installation and user manual is divided into
three main sections: Installation, which provides
the trade person with the information needed to set
up and install this product; Use and Operation,
which provides the user with the information to use
the product; and Maintenance, which provides the
user with the information needed keep it operating
efficiently.
Options and Other Information ......................................Page 19
Cleaning, Sanitation and Maintenance ..................................Page 20
Air cooled condenser filter ........................................Page 22
What to do before calling for service ...................................Page 23
Note any Caution or Warning symbols when they
appear on the product or in this manual. They
indicate potential hazards.
November 2006
Page 1
C1448, C1848, C2148W
Air and Water Cooled User Manual
Installation: Product Specifications
Location Limitations: The product is designed to be
installed indoors, in a controlled environment. Air
cooled models discharge very warm air into the
room out the back. Space must be allowed at the
left side and back for air intake and discharge.
Water cooled models discharge warm water into
the building’s drain. Space needs to be provided on
both sides and above for service access.
Space Limitations
Note: Although the machine will function, ice
capacity of air cooled machines will be significantly
reduced with minimal clearance at the sides, back
and top. Some space is recommended for service
and maintenance purposes on all models.
6" of space at the sides and back are required for
adequate operation. To get the most capacity,
locate the machine away from heat producing
appliances and heating ducts. Provide several feet
of space to the left for maximum ice capacity.
Walls or other large machines near to the ice
machine might also cause a reduction in ice
capacity. One foot behind and two feet above will
be required to make rated capacity.
Environmental Limitations
MinimumMaximum
o
Air temperature50
Water
temperature
Water pressure20 psi80 psi
F.100oF.
o
40
F.100oF.
Power supply – acceptable voltage ranges
MinimumMaximum
208-230 volt
model
198 volts253 volts
Warranty Information
The warranty statement for this product is provided
separately from this manual. Refer to it for
applicable coverage. In general warranty covers
defects in material or workmanship. It does not
cover maintenance, corrections to installations, or
situations when the machine is operated in
circumstances that exceed the limitations printed
above.
Airflow is in the front, in the left side, out the back
(as viewed from the front).
Airflow Direction
November 2006
Page 2
Product Information
C1448, C1848, C2148W
Air and Water Cooled User Manual
The product is a modular cuber. That type of
machine is designed to be placed on an ice storage
bin or an ice dispenser. Many installations only
require the matching bin, but some also require an
adapter to be placed between the bin and the
cuber or between the dispenser and the cuber.
This product cannot be stacked. See the chart
for application information.
Model Number Description
Example:
C1448SA-32A
•
C= cuber
•
14= nominal ice capacity in 100s of pounds
•
48= nominal width of cabinet
•
S= Cube size. S=small or half dice cube.
•
M=medium or full dice cube
A=Condenser type. A=air cooled. W=water
•
cooled
-32=Electrical code. -32=208-230 single
•
phase. -3=208-230 three phase
A=Series revision code. A=first series
•
Note: In some areas of this manual model numbers
may include only the first five characters of the
model number, meaning that the cube size,
condenser type and voltage differences are not
critical to the information listed there.
Options:
There are several field-installed options that can be
installed at initial start up or later. They include:
KVS - Vari-Smartä adjustable ice level
•
system.
KSB - Smart-Boardä advanced feature
•
control.
A39515-021 air baffle to reduce air
•
recirculation around the back of the cabinet
when installed in a corner.
Some installations require bin adapters. See the
table below.
Standard Bin Applications - Adapter
information.
BH1100,
ModelBH900*, B948S
C1448,
C1848,
C2148
* Note. If previously equipped with stainless steel
baffle, KBAFFLE3, remove and replace with
original plastic baffle.
Direct Fit, no
adapter needed
BH1300,
BH1600
No adapter
needed
Other Bins & Applications:
Note the drop zone and ultrasonic sensor locations
in the illustrations.
Scotsman ice systems are designed and
manufactured with the highest regard for safety
and performance. They meet or exceed the
standards of UL and NSF.
Scotsman assumes no liability of responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any part and/or other components not
specifically approved by Scotsman.
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and design are subject to change
without notice.
October 2008
Page 3
C1448, C1848, C2148W
Air and Water Cooled User Manual
Product Description & Electrical Requirements
Dimensions
w” x d” x h”
48 x 24 x 29C1448SA-32208-230/60/1Air
same
same
same
same
same
same
same
ModelElectricalCondenser
C1448SW-32208-230/60/1Water16.02030
C1448SA-3208-230/60/3Air13.62030
C1448SW-3208-230/60/3Water11.91530
C1848SA-32208-230/60/1Air25.53030
C1848SW-32208-230/60/1Water23.83030
C1848SA-3208-230/60/3Air16.52030
C1848SW-3208-230/60/3Water14.82030
Minimum
Circuit
Ampacity
Suggested
Fuse Size
17.72030
sameC2148SW-32208-230/60/1Water22.23030
sameC2148SW-3208-230/60/3Water18.02020
Table notes: Medium cube models have the same
electrical characteristics as Small. Series revision
code omitted.
Maximum
Fuse Size*
* Or HACR type circuit breakers.
This manual covers several models. The model
number on the product is located in two places, on
the back dataplate and on the model and serial
number tag, located behind the front panel.
See the illustration for the dataplate and serial tag
locations.
Write the model and serial number of this product
here:
_________________________________________
August 2008
Page 4
Cabinet Layout, Air Cooled
C1448, C1848, C2148W
Air and Water Cooled User Manual
November 2006
Page 5
C1448, C1848, C2148W
Air and Water Cooled User Manual
Cabinet Layout, Water Cooled
November 2006
Page 6
Water
C1448, C1848, C2148W
Air and Water Cooled User Manual
The quality of the water supplied to the ice machine
will have an impact on the time between cleanings
and ultimately on the life of the product. There are
two ways water can contain impurities: in
suspension or in solution. Suspended solids can be
filtered out. In solution or dissolved solids cannot
be filtered, they must be diluted or treated. Water
filters are recommended to remove suspended
solids. Some filters have treatment in them for
suspended solids. Check with a water treatment
service for a recommendation.
Scotsman filters:
A triple head filter is recommended for the potable
water. Either the Scotsman SSM3 taste and odor
filter system, or the ADS-AP3 Aqua Patrol system.
RO water. This machine can be supplied with
Reverse Osmosis water, but the water conductivity
must be no less than 10 microSiemens/cm.
Condenser Water Supply - filtration not
recommended for this water supply
Cube ice machines use more water than what ends
up in the bin as ice. While most water is used
during ice making, a portion is designed to be
drained out every cycle to reduce the amount of
hard water scale in the machine. That’s known as
water flush, and an effective flush can increase the
time between needed water system cleaning.
In addition, this product is designed to
automatically vary the amount of water flushed
based on the purity of the water supplied to it. The
water flush rate can also be set manually.
Adjustments of flush due to local water conditions
are not covered by warranty.
GPH, 70 degree water
C1448W70
C1848W106
C2148W110
Potential for Airborne Contamination
Installing an ice machine near a source of yeast or
similar material can result in the need for more
frequent sanitation cleanings due to the tendency
of these materials to contaminate the machine.
Most water filters remove chlorine from the water
supply to the machine which contributes to this
situation. Testing has shown that using a filter that
does not remove chlorine, such as the Scotsman
Aqua Patrol, will greatly improve this situation,
while the ice making process itself will remove the
chlorine from the ice, resulting in no taste or odor
impact. Additionally, devices intended to enhance
ice machine sanitation, such as the Scotsman
Aqua Bullet, can be placed in the machine to keep
it cleaner between manual cleanings
Water Flush