C0322 through C1030
Air and Water Cooled User Manual
Introduction
The design of this modular cuber is the result of years
of experience and testing. Standard features include
front accessible indicator lights and on-off switches
that provide the user with fast access to critical
information and easy operational control.
This installation and user manual is divided into
three main sections: Installation, which provides
the trade person with the information needed to
set up and install this product; Use and Operation,
which provides the user with the information to use
the product; and Maintenance, which provides the
user with the information needed keep it operating
What to do before calling for service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 21
Note any Caution or Warning symbols when they
appear on the product or in this manual. They indicate
potential hazards.
November 2012
Page 1
C0322 through C1030
Air and Water Cooled User Manual
Installation: Product Specications
Location Limitations:
The product is designed to be installed indoors, in a
controlled environment. Air cooled models discharge
very warm air into the room out the back. Space must
be allowed at the left side and back for air intake and
discharge. Water cooled models discharge warm
water into the building’s drain.
Space needs to be provided on both sides and above
for service access.
Space Limitations
Note: Although the machine will function, ice capacity
of air cooled machines will be signicantly reduced
with minimal clearance at the sides, back and
top. Some space is recommended for service and
maintenance purposes on all models. 6" of space
at the sides and back are required for adequate
operation. To get the most capacity, locate the
machine away from heat producing appliances and
heating ducts, and keep the left side away from any
wall, allow 12-18 inches of space at the left for
good air ow.
Airow is in the left side, out the back (as viewed from
the front).
Environmental Limitations
Minimum Maximum
Air temperature50oF. 100oF.
Water temperature40oF. 100oF.
Water pressure20 psi 80 psi
Power supply – acceptable voltage ranges
Minimum Maximum
115 volt model 104 volts 126 volts
230 volt model 198 volts 253 volts
Warranty Information
The warranty statement for this product is provided
separately from this manual. Refer to it for applicable
coverage. In general warranty covers defects
in material or workmanship. It does not cover
maintenance, corrections to installations, or situations
when the machine is operated in circumstances that
exceed the limitations printed above.
Product Information
The product is a modular cuber. That type of machine
is designed to be placed on an ice storage bin or
an ice dispenser. Many installations only require the
matching bin, but some also require an adapter to
be placed between the bin and the cuber or between
the dispenser and the cuber. This product cannot be
stacked. See the chart for application information.
Air Flow
November 2012
Page 2
C0322 through C1030
Air and Water Cooled User Manual
Model Number Description
Example:
• C0322SA-1B
• C= cuber
• 03= nominal ice capacity in 100s of pounds
• 22= nominal width of cabinet
• S= Cube size. S=small or half dice cube.
M=medium or full dice cube
• A=Condenser type. A=air cooled. W=water cooled
• -1=115 60 Hz, -32=208-230 60 Hz, -3= 208-230 3
phase 60 Hz
• B=Series revision code. B=second series
Note: Listed model numbers typically include only the
rst ve characters of the model number.
Options:
There are several eld-installed options that can be
installed at initial start up or later. They include:
• KVS, Vari-Smart Adjustable ice level system.
• KSB, SmartBoard Advanced feature board.
• KPMFA223-B, front air ow panel. Fits C0322 and
C0522. B series.
• KPMFA303-B, front air ow panel. Fits C0330,
C0530, C0630. B or C series.
• KPFMA309-B, front air ow panel. Fits C0830 and
C1030. B series.
• A39514-021 air bafe for corner locations. Fits
C0322, C0330, C0522, C0722, C0530, C0630.
• A39515-021, air bafe for corner locations. Fits
C0830 and C1030.
Some installations require bin or dispenser adapters.
Standard Bin Applications - Adapter information.
ModelB222
B322
C0322,
C0522,
C0722
Direct t KBT27Not
B530P,
B330P,
B530S,
HTB555
BH800,
BH801,
B842S
available
BH900,
B948S
Not
available
C0530,
C0630,
C0830,
C1030
Does not tDirect tKBT28KBT22
Hotel Dispensers
The HD22 and HD30 are compatible with this ice
machine, no adapters are needed. Some typical
combinations include:
• HD22 – use with C0322 or C0522
• HD30 – use with C0330 or C0530
Note: All models ship with the On and Off switches
front accessible. If desired, the On and Off switches
can be covered but by changing the bezel in the front
panel’s trim strip, available from a local distributor.
Ice and Beverage Dispensers – Adapter
information
Model ID150 ID200 or ID250
C0322, C0522,
KBT42 KBT43
C0722
C0530, C0630,
Does not t KBT44
C0830, C1030
Other Bins & Applications:
Note the drop zone and ultrasonic sensor locations in
the illustrations on the next pages.
Scotsman ice systems are designed and
manufactured with the highest regard for safety and
performance.
Scotsman assumes no liability of responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the use
of any part and/or other components not specically
approved by Scotsman.
Scotsman reserves the right to make design changes
and/or improvements at any time. Specications and
design are subject to change without notice.
November 2012
Page 3
C0322 through C1030
Air and Water Cooled User Manual
Product Description & Electrical Requirements
Dimensions w" x d" x h" ModelSeriesElectrical
volts/Hz/
phase
22.75** x 24 x 23 C0322SA-1A or B115/60/1Air12.715
C0322SW-1A or B115/60/1Water11.915
C0322SA-32 A or B 208-230/60/1 Air 6.1 15
C0322SW-32 A or B 208-320/60/1 Water 5.6 15
C0522SA-1 A or B 115/60/1 Air 13.8 15
C0522SW-1 A or B 115/60/1 Water 12.2 15
C0522SA-32 A or B 208-230/60/1 Air 7.6 15
C0522SW-32 A or B 208-230/60/1 Water 6.7 15
30.75** x 24 x 23C0330SA-1 A or B or C 115/60/1 Air 12.7 15
C0330SW-1 A or B or C 115/60/1 Water 11.9 15
C0330MA-32 A or B or C 208-230/60/1 Air 6.1 15
C0330SW-32 A or B208-230/60/1 Water 5.6 15
C0530SA-1 A or B115/60/1 Air 13.9 15
C0530SW-1 A or B 115/60/1 Water 12.2 15
C0530SA-32 A or B 208-230/60/1 Air 7.9 15
C0530SW-32 A or B 208-230/60/1 Water 6.7 15
C0530SA-1 C 115/60/1 Air 15.2 20
C0530SW-1C 115/60/1 Water 13.5 15
C0530SA-32 C 208-230/60/1 Air 7.8 15
C0530SW-32 C 208-230/60/1 Water 6.6 15
C0630SA-32 A or B 208-230/60/1 Air 18.2 20
C0630SW-32 A or B 208-230/60/1 Water 17 20
22.75** x 24 x 29C0722SA-32B208-230/60/1Air1015
30.75** x 24 x 29C0830SA-32A or B208-230/60/1Air10.215
C0830SW-32 A or B 208-230/60/1 Water 9 15
C0830SA-3 A or B 208-230/60/3 Air 8.4 15
C0830SW-3 A or B 208-230/60/3 Water 7.2 15
C1030SA-32 A or B 208-230/60/1 Air 16 20
C1030SW-32 A or B 208-230/60/1 Water 14.8 15
C1030SA-3 A or B 208-230/60/3 Air 11 15
C1030SW-3 A or B 208-230/60/1 Water 9.8 15
CondenserMinimum
Circuit
Ampacity
Maximum
Fuse Size*
Table notes: Medium cube models have the same electrical characteristics as Small. Series revision code
omitted.
* Or HACR type circuit breakers.
** Maximum width at top panel. Air cooled models add .75" for left side louvers.
November 2012
Page 4
C0322 through C1030
4.1
26
Air and Water Cooled User Manual
C0322 and C0522 Cabinet Layout
1.60
.88" DIA
ELECTRICAL
ACCESS
27.4
10.79
37
14.56
24.00
LEFT SIDE VIEW
3/8" FPT
61
LOUVER AND
REMOVABLE FILTER
AC UNITS ONLY
AIR COOLED
BACK VIEW
WATER
INLET
4.1
1.62
3.6
1.43
7.7
3.04
3/4" FPT
DRAIN
C0322, C0522 Air Cooled Side ViewC0322, C0522 Air Cooled Back View
10.25
8.3
3.25
ULTRASONIC
BIN LEVEL
SENSOR
(OPTIONAL)
17.8
7.00
ICE DROP OPENING
5.1
2.00
48.4
19.05
5.1
2.00
61
24.00 REF.
55.9
22.00 REF.
PLAN VIEW
22" PRODIGY
C0322, C0522, C0722 Top View
November 2012
Page 5
C0322 through C1030
4.3
26
Air and Water Cooled User Manual
C0330, C0530, C0630 and C1030 Cabinet Layout
1.70
.88" DIA
ELECTRICAL
ACCESS
37
14.59
27.5
10.81
AIR COOLED
BACK VIEW
3/8" FPT
WATER
INLET
4.4
1.73
3.7
1.48
7.8
3.06
3/4" FPT
DRAIN
C0330, C0530, C0630 Air Cooled Back View
17.8
7.00
ULTRASONIC
BIN LEVEL
SENSOR
(OPTIONAL)
76.2
30.00 REF.
PLAN VIEW
10.25
ICE DROP OPENING
2.00
5.1
8.3
3.25
48.4
19.05
2.00
5.1
61
24.00 REF.
61
24.00
LOUVER AND
LEFT SIDE VIEW
REMOVABLE FILTER
AC UNITS ONLY
C0330, C0530, C0630 Air Cooled Side View
61
24.00
LEFT SIDE VIEW
LOUVER AND
REMOVABLE FILTER
AC UNITS ONLY
C0330, C0530, C0630, C0830, C1030 Top View
November 2012
C0722, C0830, C1030 Air Cooled Side View
Page 6