Power Water Usage
Bin Basic Max. Fuse Min. Shipping Consumption Gallons/100 lbs.
Model Condenser Cap. Electrical Size or HACR Comp. Circuit Circuit Weight KWH/100 lbs. Potable Condenser
Number Unit lbs./kg. Volts/Hz/Phase Circuit Breaker HP Wires Ampacity lbs./kg. 90°F/70° F 90°F/70° F 90°F/70° F
AFE400A-1C Air 80/36 115/60/1 15 1/4 2 Cord 185/84 5.4 12.0 –
AFE400W-1C Water 80/36 115/60/1 15 1/4 2 Cord 185/84 5.0 12.0 131.0
Ice Machine Specifications
All models: Dimensions: W x D x H
without legs (Add 6˝ height for legs):
Unit: 241/4˝ x 24˝ x 33˝ Shipping Carton: 27˝ x 271/2˝ x 38˝
IMPORTANT OPERATING REQUIREMENTS:
Minimum Maximum
Air Temperatures 50
0
F (100C) 1000F (37.70C)
Water Temperatures 40
0
F (4.40C) 1000F (37.70C)
Water Pressures 20 PSIG 80 PSIG
Electrical Voltage -5% +10%
Finish: Rotocast grey plastic.
Refrigerant R-134A.
LEGS SUPPLIED:
Four black plastic legs screw into mounting plates on cabinet base. Provide
6˝ minimum height including adjustable leveling foot.
Consult Your Local SCOTSMAN Representative At:
Machine requires voltage indicated on rating name plate. Failures caused by improper voltage are not considered factory defects. Extended periods of operation at temperatures exceeding limitations constitutes
misuse under the terms of Scotsman Manufacturer’s Limited Warranty, resulting in a loss of warranty coverage. Specifications and design are subject to change without notice.
Scotsman’s ice machines are not designed for outdoor installations. Scotsman remote condensers are
designed for outdoor installations.
SU-400 7M 3-05
INSTALLAT ION NOTE: Allow 6˝ minimum space at back for utility connections.
775 Corporate Woods Parkway • Vernon Hills, IL 60061 • 1-800-SCOTSMAN • Fax: (847) 913-9844
Visit our website at: www.scotsman-ice.com • E-mail: customer.service@scotsman-ice.com
Y OU’LL VALUE THE DIFFERENCE.
TM