Product Application Bulletin
Bulletin Number: 2010-01
Subject: Approved Condensers
Condenser coils in certain rack condensing units have been approved for use with Scotsman Remote cooled
cube ice equipment. They include:
Bohn G or X series: MAC4XS6C; MAC7XS6C or MAC8XS6C
•
Master Bilt: R62R1104C; R62R1104CC; R62R1103C; R62R1105C
•
Conditions
The condenser coil must NOT have been connected to an R-502 or R-22 system.
•
A head pressure control valve, like a headmaster, must be added. Scotsman’s kit for the above is
•
RCKCME6GX
Eclipse condensing units
The condenser coil must NOT have been connected to an R-502 or R-22 system.
•
Only the condenser coil part of the rack has been approved. Use of the Eclipse CP is mandatory. If
•
connecting an Eclipse CP compressor pack to one of the above, a head pressure control valve is NOT
needed.