Scotsman HID312AW1, HID525AW1, HID540AW1 Installation Manual

Page 1
Installation and User’s Manual for
Meridian Ice Maker-Dispensers
Wall Mount Models
HID312AW, HID525AW and HID540AW
Page 2
HID312AW, HID525AW and HID540AW Installation and User’s Manual
The ice maker-dispensers covered in this manual
were designed by to be the nest on the market. Their
design is a result of Scotsman’s long experience in ice
maker-dispensers.
This manual includes the information needed to
install, start up and operate the machine. Because
there are three models covered, be sure that any
instructions apply to your unit.
HID312 is 16 inches wide.
HID325 is 21 inches wide and 35 inches tall.
HID340 is also 21 inches wide, but it is 40 inches tall.
Contents
Specications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 3
HID312AW Cabinet Drawing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 4
HID525AW Cabinet Drawing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 5
Observe any caution or warning notices. They are important and provide notice of potential hazards. Keep this manual for future reference.
If additional technical information is needed, go to
Scotsman’s website, www.scotsman-ice.com to download a service manual.
HID540AW Cabinet Drawing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 6
Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 8
Wall Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 9
Initial Start Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 10
Operation: Ice and Water Vending . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11
Controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 12
Maintenance and Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 13
Maintenance and Cleaning - Dispensing bin and ice level controls . . . . . . . . . . . . . . . . Page 14
Ice level controls, . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 15
Ice Making and Ice Dispensing System Cleaning Instructions. . . . . . . . . . . . . . . . . . . Page 16
Basic Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 18
Controller Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 19
July 2018
Page 2
Page 3
HID312AW, HID525AW and HID540AW Installation and User’s Manual
Specications
The ice maker-dispenser is designed to be installed
indoors, in a controlled environment. Although
it can operate in a wide range of air and water temperatures, it will provide the best performance if
not subject to extremes.
Air Temperature Limitations
• Maximum: 100oF. or 38oC.
• Minimum: 50oF. or 10oC.
Water Temperature Limitations
• Maximum: 100oF. or 38oC.
• Minimum: 40oF. or 4.4oC.
Water Pressure, potable
Maximum: 80 PSI or 5.5 Bar
Minimum: 20 PSI or 1.3 Bar
Water Conductivity:
• Minimum: 10 microSiemens/cm
RO water may be supplied to the potable water system, but if it has less than the above conductivity, the water level sensor will not detect water and the
unit will not make ice.
Deionized water will not work and isn’t recommended.
Voltage
• Maximum: 126 Minimum: 104
Operating the machine outside of any of the above limitations is considered abuse and any resulting damage is not covered by warranty and could cause a
complete loss of warranty coverage.
Product Information
The product is an ice maker-dispenser. It is designed to be hung on a wall over a sink.
All models require a drain. An internal drain basin
separates the ice storage bin’s drain from other
drains.
A backow preventer may be required by local
plumbing codes.
A power cord with NEMA 5-15P plug is included.
Air cooled models ow air left to right and include
a cleanable air lter.
• Ice or water vending is triggered by touch free
sensors, no other activation method is available.
For available options and kits, see sales literature.
Scotsman Ice Systems are designed and manufactured with the highest regard for safety and
performance. They meet or exceed the standards of UL and NSF.
Scotsman assumes no liability or responsibility of any kind for products manufactured by Scotsman that have been altered in any way, including the use
of any part and/or other components not specically approved by Scotsman.
Scotsman reserves the right to make design changes
and/or improvements at any time. Specications and design are subject to change without notice.
Warranty Information
The warranty statement for this product is provided
separately from this manual. Refer to it for applicable coverage. In general warranty covers defects in material or workmanship. It does not cover
maintenance, corrections to installations, or situations when the machine is operated in circumstances that
exceed the limitations printed above.
Model Electrical Condenser Typical Amp Draw Maximum Fuse Size HID312AW-1A 115/60/1 Air 5.7 - 6 15 HID525AW-1A 115/60/1 Air 7.2 - 8 15 HID540AW-1A 115/60/1 Air 7.2 - 8 15
March 2015
Page 3
Page 4
HID312AW, HID525AW and HID540AW
REMOVABLE
ICE CHUTE
AIR FLOW
Installation and User’s Manual
HID312AW Cabinet Drawing
40.6
16.00
2.8
1.12
3/8" FLARE
WATER INLET
4.6
1.80
BACK VIEW
8.3
3.25
3/4" FPT
DRAIN
9.7
3.80
POWER
CORD
CHASE
UTILITY
61.9
24.38
88.6
0.8
34.88
.312
(6) WALL
MOUNT HOLES
14
5.50
14
38
14.95
AIR FLOW
5.50
16.9
6.66
5.1
2.01 CHASE
UTILITY
2.5
1.00 WALL
FROM
OFFSET
44
17.33
RIGHT SIDE VIEW
7.7
3.02
46.4
18.25 BRACKET
WALL MOUNT
41.3
16.25
March 2015
Page 4
AIR FILTER
40.6
WATER CHUTE
16.00
FRONT VIEW
Page 5
HID312AW, HID525AW and HID540AW
REMOVABLE
ICE CHUTE
AIR FLOW
Installation and User’s Manual
HID525AW Cabinet Drawing
40.6
16.00
.312
0.8
(6) WALL
MOUNT HOLES
3/8" FLARE
WATER INLET
5.2
2.05
BACK VIEW
17.9
7.05
3/4" FPT
DRAIN
9.7
3.80 CHASE
UTILITY
POWER
CORD
14
5.50
14
5.50
16.9
6.66
5.1
2.01 CHASE
UTILITY
59.1
61.9
23.25
24.38
BRACKET
WALL MOUNT
54
21.25
88.6
34.88
AIR FLOW
2.5
1.00 WALL
FROM
OFFSET
44
17.33
RIGHT SIDE VIEW
7.7
3.02
38
14.95
53.3
21.00
FRONT VIEW
WATER CHUTE
AIR FILTER
March 2015
Page 5
Page 6
HID312AW, HID525AW and HID540AW
REMOVABLE
ICE CHUTE
AIR FLOW
Installation and User’s Manual
HID540AW Cabinet Drawing
40.6
16.00
0.8
.312
(6) WALL
MOUNT HOLES
3/8" FLARE
WATER INLET
5.1
2.00
BACK VIEW
17.9
7.05
3/4" FPT
DRAIN
POWER
CHASE
UTILITY
5.1
CORD
2.01 CHASE
UTILITY
9.7
3.80
5.50
14
5.50
16.9
6.66
14
59.1
23.25
61.9
24.38
BRACKET
WALL MOUNT
54
21.25
103.8
40.88
AIR FLOW
2.5
1.00 WALL
FROM
OFFSET
44
17.33
RIGHT SIDE VIEW
7.7
3.02
38
14.95
53.3
21.00
FRONT VIEW
WATER CHUTE
March 2015
Page 6
AIR FILTER
Page 7
HID312AW, HID525AW and HID540AW Installation and User’s Manual
Placement
The location of the equipment should be selected
with care. Consideration should be given to allow
adequate space on the sides for air cooled models
to breathe. Minimum clearance is 3 inches at the sides, none at the back and 2 inches above. The
power outlet should be located within the length of the
supplied power cord.
Air cooled models in a small room require ventilation
to exhaust the heat they produce. They also produce some added noise from the fan.
Nearby infrared emitters or a window that allows sunlight to shine on a dispensing sensor may cause
the unit to dispense ice or water on its own.
Wall mount units do NOT have a drip tray, so they MUST be positioned over a sink to collect any dripping water or spilled ice.
Wall Mount
These models are designed for mounting on a wall.
Check building wall for the strength required to
support a machine of this weight and size. Note that
if at least 6” of space is not left above the machine, cleaning and most service of the machine will require
removal of the machine from the wall mounts. All utilities are to be routed thru the base. One inch of
space is needed between the wall and the back of the
machine.
Note: The wall must be plumb or the unit will be out of
level front to back.
Remove bolts holding machine to pallet. Use caution to not tip unit too far when removing bolts.
Remove the protective plastic covering the panels.
The longer it is left on the panel, the harder it will be
to remove it.
Set Up
It is a good idea to remove the front panels and inspect for any loose or rubbing parts
prior to installation.
It is recommended that the wall mounting installation
be done by an experienced contractor.
The weight of the machine when in use may exceed
350 pounds. The unit should be mounted on a solid,
rigid wall with proper fasteners for that type of wall and of adequate strength to support the weight of the
machine when in use.
Unpack
Separate the carton from the shipping pallet.
Important: Locate and retain the wall mounting brackets, they were shipped in a box on the skid in front of the unit.
Remove any strapping holding the cabinet to the
pallet.
Inspect for hidden shipping damage. If any is found, retain carton and notify carrier for potential claim. Shipping damage is not covered by warranty.
March 2015
Panel Removal
Remove one screw at bottom front of upper front panel, swing bottom of panel forward
and lift off the unit.
Twist ice and water chutes counterclockwise and pull
down to remove.
Remove four screws from sides of splash panel, pull
forward slightly. If needed, unplug sensor connector and separate panel from unit.
Pre-Start Inspection
Conrm there are no loose or rubbing parts.
Page 7
Page 8
HID312AW, HID525AW and HID540AW Installation and User’s Manual
Installation
Installation should be done by an experienced ice
machine installer. To locate one, call the number on
the back of this manual or go to Scotsman’s website
www.scotsman-ice.com to identify a local distributor or service company.
The machine will require power, water and drain. Locate the water supply tting on the lower back of the cabinet and obtain the correct tting to connect the water supply.
Plumbing Fittings:
Potable water inlet: 3/8 male are.
Cabinet drain: 3/4 FPT.
Connect drain tubing to the 3/4 inch FPT central drain
tting at the back of the cabinet. Use 3/4 inch rigid tubing, use material to meet local codes. The drain
basin in the machine will act as an internal vent, no additional vent should be required unless there is a
very long horizontal run. Drain tubing must pitch down 1/4 inch per foot to the building drain. Insulation of drain tubing is recommended for most environments.
Install Wall Mounting Brackets
See next page for detailed instructions.
Electrical Supply - 115 volt models
Plug the unit into a dedicated 15 amp outlet. The unit must be the only device on the circuit. Conrm the outlet is properly grounded and is in good condition.
Worn outlets should be replaced as they can cause
erratic operation of equipment. Do not use an extension cord. Do not cut off the ground plug on the power cord.
Ground fault outlets are not recommended. If ground
fault is required a ground fault breaker should be
used.
Drain Tubing
Potable Water
Connection
All models:
Note: Wall mounting limits access to the utility connections which are at the back bottom of
the machine. Pre-plumbing the water and drain is required so that stubs are available for nal connection to water and drain.
Connect the potable water supply tube to the 3/8
inch male are inlet at the bottom back of the unit. Water lters may be used but are not required. Note that activated carbon or charcoal water lters are
used for taste and odor problems but also take out any chlorine that the local water agency may have
added for purication. That can require more frequent sanitization of the equipment.
March 2015
Page 8
Use the services of a licensed electrician when
needed and conform to local and national codes.
Position the unit in its nal location.
Level the unit front to back and left to right.
Page 9
HID312AW, HID525AW and HID540AW Installation and User’s Manual
Wall Mounting
It is recommended that the wall mounting installation
be done by an experienced contractor.
The weight of the machine when in use may exceed
350 pounds. The unit must be mounted on a solid,
rigid wall with proper fasteners for that type of wall and of adequate strength to support the weight of the
machine when in use.
The machine will have a bracket and there will be
one bracket mounted to the wall. The machine will
hang from the wall bracket by the upper bracket on
the back of the cabinet. The lower bracket keeps the machine plumb to the wall.
1. Attach the water and drain tubing so the tubing extends below the bottom of the cabinet. That
allows connection when the machine is on the
wall.
2. Locate the box with the mounting brackets.
Separate the two
brackets. Retain the bolts and lock washers.
3. Identify the location of
the wall studs or other materials to be used to
fasten the wall bracket to.
4. Mount the wall bracket
(has threaded inserts) to the wall using the appropriate methods and
fasteners. Note: Must be level left to right.
6. Use a mechanical hoist to lift the cabinet high enough to t the ange of the machine bracket over the lip of the wall bracket. Then push it back and lower it onto the wall bracket.
7. Secure the wall and machine bracket with
the bolts and lock washers originally used in
shipment.
Bracket, mounts to back of dispenser.
Bolt the two brackets
together after unit is
mounted.
The wall bracket extends beyond the width of the machine to allow attachment
to multiple wall studs.
5. Mount the other bracket
to the back of the ice machine cabinet at the joint between the two back panels, using 9 existing screws in the
back.
Use cabinet screws to
attach to back of unit.
Bracket, mounts to wall.
March 2015
Page 9
Page 10
HID312AW, HID525AW and HID540AW Installation and User’s Manual
Initial Start Up
Final check list:
1. Is the icemaker-dispenser installed indoors, in a location where the air and water temperatures are controlled, and where they do not go beyond design limitations?
2. Is there an electrical disconnect (switch or plug as required) within sight of the installed machine? Is the machine on a separate circuit? Has the voltage been checked and compared to nameplate requirements?
3. Have all of the plumbing connections been made and checked for leaks?
4. Has the machine been leveled?
5. Is there a minimum of 6 inches of clearance at the
left and right sides of an air cooled machine?
6. Is there a minimum of 6 inches of clearance at the top of the machine for service?
7. Is there a water shut off valve installed near the machine?
Start Up
4. Push and release the On/Off button. The machine will start the ice making process. The code display
will show F. Air cooled models will discharge warm air out the right side, water cooled models will discharge warm (about 110oF.) water out of the
condenser drain.
5. Soon ice will begin to fall into the dispensing bin.
Check ice dispensing by holding a container in front of the Touch Free ice sensor (just below the
ice delivery spout). Ice should ow from the spout
when a container is present, and stop dispensing
when the container is removed.
6. Check water dispensing by holding a container in front of the Touch Free water sensor. Water will ow when a container is present and stop when it is removed.
7. Push the On/Off button to switch the machine off.
8. Unplug or disconnect electrical power.
9. Remove the top panel and the top of the ice storage bin. Scoop out any ice in the bin and
sanitize the interior of the ice storage bin by wiping it with a locally approved sanitizer or a mixture of 1 ounce of household bleach to 2 gallons of water,
allow to air dry.
ON / OFF
1. Remove upper front panel
2. Open the water hand valve, observe that water enters the water reservoir, lls and then shuts off. Check for leaks. Repair any leaks before going any further.
3. Switch electrical supply on. Lights on controller will ash and then the power light will remain on. The code display will show O.
10. Reconnect electrical power.
11. Push the On/off button to switch the machine on.
12. Replace all covers and panels.
13. Give the owner/user the user manual, instruct
him/her in the operation and maintenance
requirements of the unit. Make sure they know who to call for service.
14. Fill out the Customer Evaluation and Warranty
Registration form, and mail it in to Scotsman or
register the unit at Scotsman’s website (www. scotsman-ice.com).
March 2015
Page 10
Page 11
HID312AW, HID525AW and HID540AW Installation and User’s Manual
Operation: Ice and Water Vending
Dispensing takes place when the Touch Free sensor’s infrared beam bounces back to the sensor from a
container placed directly in front of it.
If the container is in front of the Touch Free sensor on the left side, the ice dispensing rotor will rotate
and sweep ice over the ice dispensing chute. Ice will
continue to discharge out this chute as long as the
rotor is turning. It stops when the rotor stops.
Dispense
Sensors
container.
Both dispensing and ice making are disabled
when the unit is switched off at the controller.
Splash panel wipe-off. Wiping the splash panel could result in unintended dispensing. To avoid that, a disable button has been provided. It is recessed into the bottom of the chute panel. Push and release it to disable dispensing for 60 seconds.
Vending Disable
Switch
If the user does not remove the container, ice will be
dispensed for 24 seconds and then stop.
If the container is in front of the Touch Free sensor on the right side, the inlet water valve will open and water
will ow into the container.
If the user does not remove the container water will be
dispensed for 20 seconds and then stop.
Note: Water may dispense cloudy and then clear up in
the glass. That is normal due to air in the water and is not an indicator of any malfunction.
Other notes:
• An occasional drip may be seen from the ice
dispense chute. This is normal and is from ice melting inside the chute. A continuous stream of water from the ice chute indicates a restricted bin drain.
Noise
This is a commercial ice machine. It contains a
powerful compressor, heavy duty gear reducer and, if
air cooled, a fan that moves a lot of air. It will produce some noise when it is making ice. Every effort was
made during its design to minimize the sound level
but some is unavoidable.
• Clear containers (glass or plastic) may not always
activate the dispense sensors. Retry with an opaque
March 2015
Page 11
Page 12
HID312AW, HID525AW and HID540AW Installation and User’s Manual
Controller
All models use the same control system.
The electronic controller operates the compressor (with fan motor), auger drive motor, dispense drive
motor and inlet water solenoid valve. It monitors:
• Reservoir water availability
• Storage bin ice level
• Call for ice dispense
• Call for water dispense
• Refrigeration pressure
• Dispense enable / disable
• Auger motor speed
• Auger motor rotation
• Any installed control options
Many of these are used to insure that the machine
does not damage itself during use. For example, it is
critical that it not attempt to make ice without water, so if the water sensor is dry, the machine will not make
ice.
Switches - there are four switches:
Dispense water - to test water dispensing
Dispense ice - to test ice dispensing
On/Off - to switch the machine on or off. Holding it
in to shut off will stop ice making immediately.
There is also a code display, the codes are: O - - - for off F - - - for ice making b - - - for bin full E - - - for controller error C - - - for clean mode d - - - for test mode 1 - - - for auger rotation direction wrong 2 - - - for auger speed too slow 3 - - - for no water sensed 4 - - - for high refrigerant pressure
If a number code is triggered, the controller will stop
ice making. A blinking code means it is a temporary condition. Example: A blinking F occurs during the
ice making restart process; it stops blinking when the
compressor starts.
The controller will automatically restart from a water interruption or power interruption or when a refrigerant
pressure switch has automatically reset.
To reset the control when it has been manually locked out, Push and release the On/Off button to shut it Off
and then Push and release it again to switch it On.
Note: The compressor will not restart for 2 minutes
from the time it was shut off.
Clean - to engage the clean mode
Indicators - there are nine LEDs:
Power - Glows when controller has power
Status - Glows when in ice making mode
Time to Clean - Glows when it is time to clean the
machine
Water Dispense Sensed - glows when the water dispense sensor has been triggered*
Ice Dispensed Sensed - glows when the ice dispense sensor has been triggered*
Water Dispense - glows when the inlet water solenoid valve has been powered*
Ice Dispense - glows when the ice dispense motor has been powered*
Auger - glows when the auger motor is on
Compressor - glows when the compressor is on
* If blinking the water or ice dispensing time limit has
been met.
March 2015
Page 12
Page 13
HID312AW, HID525AW and HID540AW Installation and User’s Manual
Maintenance and Cleaning
There are ve areas of maintenance:
1. Drain system
2. Air cooled condenser lter and condenser
3. Ice dispense bin and rotor
4. Photo eye ice level control
5. Ice making water system
Drain System
1. Remove upper front panel.
2. Twist dispense chutes clockwise and pull down to remove.
3. Push in dispense disable switch, remove screws
holding lower front panel to unit and unplug lower
panel sensors at the harness connection. Set panels aside.
4. Shut the machine off.
5. Pour hot water into the drain basin to conrm free drainage.
6. Clean the dispense chutes. Use ice machine scale remover if needed to dissolve scale.
Condenser.
The condenser ns may need cleaning too. Remove
the left side air grill and brush any lint and dirt off the
surface of the condenser. Vacuum any remaining dirt. Do not damage the ns of the condenser during cleaning.
7. Reverse to reassemble. Insert chutes and rotate CCW until they snap into place and stop.
Air lter
The air lter on the left side of the cabinet will capture signicant dust and lint during operation. As the dirt builds up it begins to restrict air ow and causes the refrigeration system to work longer to make ice. Clean the air lter regularly.
To remove, pull it forward from the louvers. Do not leave it out for extended periods of time.
To clean, wash it at a utility sink. Return it to the unit when clean.
March 2015
Page 13
Page 14
HID312AW, HID525AW and HID540AW Installation and User’s Manual
Maintenance and Cleaning - Dispensing bin and ice level controls
The ice storage bin and rotor must be cleaned and sanitized on a regular basis, at a minimum when the
ice making system is cleaned. Hand tools and hand
protection like rubber gloves are recommended for
this procedure.
Note: Some steps overlap with the procedure on the
next page. This procedure can be independent of the ice making system cleaning or can be part of it.
1. Remove upper front panel.
2. Remove top panel.
3. Shut machine off.
4. Vend or melt out all ice.
Note: Only add 16 oz water to the bin at a time, as
excess water will drain out the spout.
5. Disconnect ice level control at harness.
6. Unplug or disconnect unit from electrical power.
11. Mix a solution of ice machine scale remover, such
as Scotsman Clear 1 and potable water per the
directions supplied with the scale remover.
Dispense
Rotor
Dispense Drive Pin
Moving parts hazard.
Risk of personal injury.
Disconnect electrical power before
proceeding.
7. Remove ice storage bin cover, set aside.
8. Remove agitator bar (rotate CCW), set aside.
9. Remove 2 thumbscrews & chute cover, set aside.
10. Lift up and remove dispense rotor, set aside.
Agitator
Chute Cover
12. Use a clean cloth and wash all the interior surfaces of the bin and the bin cover, agitator bar, chute cover and dispense rotor with the ice
machine scale remover solution. Rinse with clear water.
13. Mix a 2 gallon solution of locally approved sanitizer. A possible sanitizer solution is one
packet of Stera Sheen Green Label and 2 gallons of warm (95o to 105oF.) potable water.
14. Use a new clean cloth and wash all the interior surfaces of the bin and the bin cover, agitator bar, chute cover and dispense rotor with the sanitizer
solution.
15. Return all parts to their original positions and secure them with their original fasteners.
16. Reconnect electrical power and restart the machine.
March 2015
Page 14
Page 15
HID312AW, HID525AW and HID540AW Installation and User’s Manual
Ice level controls,
Clean if the controller indicates bin full and there is no ice between the sensors.
1. Remove top front and top panels.
2. Shut machine off.
3. Disconnect ice level controls at connector.
4. Remove 3 screws and ice storage bin cover.
5. Pull each sensor grommet clip up and off.
Clip
Cover
Sensor
Grommet
6. Push grommets out of bin top.
6. Remove the chute mounting panel.
7. Remove splash
panel, disconnect sensors from harness and set
panel aside.
7. Pull each sensor out of its rubber grommet. Pull on the part closest to the grommet, not the wire.
8. Wipe the sensor lenses clean with a soft, clean cloth. Caution - do not scratch the lens. If there
is mineral scale on the lens, ice machine scale
remover will be needed to wipe them clean.
9. Return each sensor to a grommet, push it in until it snaps into place.
10. Reverse the rest of the steps to reassemble.
Dispensing Bin
The dispensing bin may be removed for cleaning or to
provide service access to other components.
1. Go thru steps 1 thru 10 of the Bin Cleaning Procedure above.
2. Remove ice sweep.
3. Remove ice delivery chute and chute cover.
4. Remove dispense motor drive pin.
5. Twist and remove the water and ice dispense chutes.
8. Locate two 3
prong knob bolts
under the bin. Remove them.
9. Locate bin drain
and disconnect it
from bin tting.
10. Lift the bin up and off the chassis. Clean as needed.
March 2015
Page 15
Page 16
HID312AW, HID525AW and HID540AW Installation and User’s Manual
Ice Making and Ice Dispensing System Cleaning Instructions
Hand tools, cleaning supplies and hand protection are
recommended for this procedure.
Frequency: Recommended minimum time between
cleanings is 6 months. To aid in determining if the
machine has not been cleaned in 6 months, a Time To Clean light will glow after 6 months of power up
time. Cleaning the machine with the following process will reset that light and the timer that controls it. More
frequent cleanings may be required based on the mineral content of the water, run time and potential
airborne contamination.
1. Remove both front panels.
2. Push On/Off button to shut ice making off.
3. Shut water supply off.
4. Drain water from ice making system by pulling
reservoir drain hose from plug at drain basin and
return to plug when drained.
Note: Drain into drain basin in base of unit. Sink must be attached to unit throughout this process.
5. Remove reservoir cover and ll with hot (110-120 degree F.) water, wait 2 minutes and drain water
from ice making system by pulling reservoir drain hose from plug and return hose to plug when
drained.
Scotsman Ice Machine
Cleaner contains acids.
These compounds may cause
burns.
If swallowed, DO NOT
induce vomiting. Give large amounts of water or milk. Call Physician immediately. In case of external contact, ush with water.
KEEP OUT OF THE REACH OF CHILDREN
6. Mix a solution of 12 ounces of Scotsman Clear 1 ice machine scale remover and 12 ounces of
clean, potable water.
7. Loosen thumb screw holding water reservoir to post.
8. Lift water reservoir to the top of the post and re- secure with the thumb screw.
9. Remove cover from water reservoir.
11. Remove dispense bin cover.
12. Remove ice discharge chute cover from top of ice making system.
13. Pour cleaning solution into reservoir. Caution: solution is highly acidic. Use rubber gloves and Do Not Spill.
Moving parts hazard.
Risk of personal injury.
Disconnect electrical power before
proceeding.
14. Push the Clean button. The unit will operate the auger motor for 30 minutes and then stop.
Note: Stop at any time by pushing the On/Off button.
15. Disconnect unit from electrical power.
16. Drain the scale remover solution from the water
system by pulling the reservoir drain hose from its
plug and return it to the plug when drained.
17. Pour 24 ounces
of clean, potable water into the
reservoir.
18. Drain the water
from the water system by pulling the reservoir drain hose from its plug and return it to
the plug when drained.
19. Mix a solution of 4 ounces of ice machine scale remover and 16 ounces of potable water. Use
this scale remover solution to washout the water reservoir cover, ice discharge chute, ice chute cover, ice delivery chute, storage bin cover and
inside of the ice storage bin. Slowly pour the cleaning solution down the bin drain.
10. Vend all ice from dispenser.
March 2015
Page 16
Page 17
HID312AW, HID525AW and HID540AW Installation and User’s Manual
Sanitize now.
20. Mix a 2 gallon solution of sanitizer. A recommended sanitizer solution is one 2 oz.
packet of Stera Sheen Green Label and 2 gallons of warm (95o to 105oF.) potable water, or an
equivalent sanitizer at a concentration of 100 ppm.
21. Pour the sanitizer solution into the reservoir until it is full (level with the molded line on the side).
22. Reconnect electrical power.
23. Push the On/Off button to make ice for 10 minutes. Add more sanitizer to the reservoir to keep it full while making ice.
24. Push the On/off button to stop making ice.
25. Disconnect electrical power.
26. Remove the ice outlet cover, dispense rotor and ice dispenser agitator from the bin. Wash them with the sanitizer solution.
27. Wash all inside surfaces of the ice storage bin and ice discharge chute with the sanitizer solution.
28. Wash the ice discharge chute cover, ice sweep,
metal area below the ice sweep and ice dispense
chute with the sanitizer solution.
33. Return the ice dispense chute and water reservoir
cover to their original positions and secure them
with their original fasteners.
34. Reconnect water and electrical power to the machine.
35. Push the On / Off button to restart ice making.
36. Operate machine for 5 minutes and then push the On / Off button to stop ice making.
37. Pour 16 oz of warm (95o to 105oF.) potable water into the bin. Repeat until the ice has been melted.
38. Return the dispense bin cover to the machine and secure with the original screws.
39. Push the On / Off button to resume ice making.
40. Return all panels to their normal positions and secure with the original screws.
Other maintenance
The auger in the ice making system is centered by a
bearing at the top. It is also sealed from leaking by a water seal at the bottom. It is important that the top
bearing and lower water seal be periodically checked
for wear.
29. Pour remaining sanitizer into the bin and sink. Do not overll bin.
30. Drain sanitizer from ice making system by pulling
reservoir drain hose from plug and return hose to
plug when drained.
31. Loosen thumb screw holding water reservoir to
post and lower the water reservoir to the top of the
slot, retighten thumb screw.
32. Return the chute cover, dispense rotor and agitator to the inside of the storage bin. Secure with the original fasteners.
March 2015
Page 17
Page 18
HID312AW, HID525AW and HID540AW Installation and User’s Manual
Basic Troubleshooting
See the separate HID service manual for more advanced troubleshooting information.
Symptom Possible Cause Probable Correction
No ice is dispensed No ice in bin Unit in Off mode. Remove upper front panel and
check controller code, push On/Off button to restart. No water to unit. Controller shows code 3. Restore
water supply. No power to unit, power light on controller is off.
Restore power. High pressure control opened. Controller shows
code 4, water interrupted to water cooled model. Restore water and reset controller.
Ice level control sensing full bin falsely. Controller shows b. Clean ice level control sensors.
Dispense motor not turning Remove upper front panel, check controller indicator
lights. Hold container in front of sensor, does the
Ice Dispense Sensed light glow? If no, sensor is
not detecting the container. If yes, does the Ice
Dispense light glow? If yes, push Dispense Ice
button. Does the motor activate? If yes, go to next row. If no, check for voltage at motor. If no voltage, replace controller. If voltage at motor, replace motor.
Dispense motor working, but ice in bin not moving
No water is dispensed No water to unit. Restore water.
Water valve not opening Remove upper front panel, check controller indicator
Water drips from spout May be normal A few drops per minute is normal.
Bin drain may be plugged. Check bin drain tube at basin.
Dispensed water is cloudy, but clears up in a few minutes
Air in the water This is normal and can vary depending upon how
Agitator or rotor not turning, remove all ice and
inspect for damage to agitator and rotor.
lights. Hold container in front of sensor, does the
Water Dispense Sensed light glow? If no, sensor is
not detecting the container. If yes, does the Water
Dispense light glow? If yes, push Dispense Water
button. Does the water valve activate? If no, check for voltage at valve. If no voltage, replace controller. If voltage at valve, replace valve.
much air is in the water. May be improved by lowering water pressure to the unit.
March 2015
Page 18
Page 19
HID312AW, HID525AW and HID540AW Installation and User’s Manual
Controller Diagnostics
Code or Light Action Probable Cause Suggested Action
O F b E C d
1
2
3
4
Water dispense sensed light blinking
Water dispense light blinking Ice dispense sensed light blinking Container positioned in front of ice Ice dispense light blinking
Unit manually switched off If desired, switch unit on.
Freeze mode None, unit is making ice.
Bin sensors sense bin full Check if bin is full.
Corrupted memory Replace controller
Clean mode Continue clean mode
Test mode None, allow unit to nish test
mode.
Auger motor rotated auger
backwards.
Auger motor stalled or operating slowly
No water in reservoir Restore water. If there is water,
High pressure cut out open Check fan motor on air cooled or
Container positioned in front of water dispense sensor for more than 24 seconds
dispense sensor for more than 20
seconds.
Replace auger motor. Check water
seal area for leaks, replace seal if
leaking. Clean ice making system and retry.
is it too pure? Are sensor wires connected?
water supply on water cooled.
Normal, controller has a time limit
for dispensing. Remove container.
Status light is on Unit is in ice making mode Normal, may not be making ice if
bin is full
Time to Clean light is on Unit has not been cleaned for at
least 6 months
Water Dispensed Sensed light is onA container is in front of the sensor Normal during water dispensing
Ice Dispensed Sensed light is on A container is in front of the sensor Normal during ice dispensing
Water Dispense light is on Water solenoid has been activated Normal during water dispensing
Ice Dispense light is on Bin drive motor has been activated Normal during ice dispensing
Auger light is on Auger motor is active Normal when making ice
Compressor light is on Compressor is active Normal when making ice
March 2015
Page 19
Clean unit
Page 20
SCOTSMAN ICE SYSTEMS
101 Corporate Woods Parkway
Vernon Hills, IL 60061
800-726-8762
17-3492-03 Rev. A
Loading...