This ice machine is the result of years of experience
with aked and nugget ice machines. The latest in
electronics has been coupled with the time tested
Scotsman aked ice system to provide reliable ice
making and the features needed by customers.
The features include simple conductivity water level
sensing, evaporator clearing at shut down, photo-eye
sensing bin control and the ability to add options.
D Series Remote Low Side User Manual
Installation:
This machine is designed to be used indoors, in a
controlled environment. Operation outside the limits
listed here will void the warranty.
Air temperature limits
Minimum Maximum
Ice maker 50
o
F. 100oF.
Water temperature limits
Minimum Maximum
All models 40
o
F. 100oF.
Water pressure limits (potable)
Minimum Maximum
All models 20 psi 80 psi
Voltage limits
Minimum Maximum
115 volt 104 126
Most water lters remove chlorine from the water
supply to the machine which contributes to this
situation. Testing has shown that using a lter that
does not remove chlorine, such as the Scotsman
Aqua Patrol, will greatly improve this situation.
Warranty Information
The warranty statement for this product is provided
separately from this manual. Refer to it for applicable
coverage. In general warranty covers defects
in material or workmanship. It does not cover
maintenance, corrections to installations, or situations
when the machine is operated in circumstances that
exceed the limitations printed above.
Minimum conductivity (RO water)
• 10 microSiemens / CM
Water Quality (ice making circuit)
• Potable
The quality of the water supplied to the ice machine
will have an impact on the time between cleanings
and ultimately on the life of the product. Water can
contain impurities either in suspension or in solution.
Suspended solids can be ltered out. In solution
or dissolved solids cannot be ltered, they must be
diluted or treated. Water lters are recommended
to remove suspended solids. Some lters have
treatment in them for suspended solids. Check with a
water treatment service for a recommendation.
RO water. This machine can be supplied with Reverse
Osmosis water, but the water conductivity must be no
less than 10 microSiemens/cm.
Potential for Airborne Contamination
Installing an ice machine near a source of yeast
or similar material can result in the need for more
frequent sanitation cleanings due to the tendency of
these materials to contaminate the machine.
October 2014
Page 3
Page 4
N0922L, N1322L, F1222L, F1522L
D Series Remote Low Side User Manual
Location:
While the machine will operate satisfactorily within the
air and water temperature limits, it will operate more
efciently when those temperatures are nearer the
lower limits. Avoid locations that are hot, dusty, greasy
or conned.
Options
The standard machine will make ice until ice lls
the bin and blocks an infrared light beam inside the
bottom of the machine. A eld installed kit is available
to adjust the ice level lower. That kit number is KVS.
The standard controller has excellent diagnostic
capabilities and communicates to the user through the
AutoAlert light panel, seen through the front panel.
There is a eld installed kit that can log data and
provide additional information when the front panel is
removed. That kit number is KSBU. A similar kit adds
network connectivity, and its number is KSB-NU.
Bin compatibility
All models are the same width: 22 inches. All models
are the same depth: 24 inches.
Dispenser compatibility
Only nugget ice models may be used with ice
dispensers. Flaked ice is not dispensable.
• ID150 – use KBT42 and KDIL-PN-150; includes
KVS, KNUGDIV and R629088514
• ID200 – use KBT43 and KNUGDIV and KVS
• ID250 – use KBT43 and KNUGDIV and KVS
See sales literature for other brand model ice and
beverage dispenser applications.
Other Bins & Applications:
Note the drop zone and ultrasonic sensor locations in
the illustrations on the next page.
Line Set
NRTE45 is a non-precharged tubing kit that contains
a 45 foot 3/8" liquid line and a 45 foot 5/8" suction
line. Tubes are supplied nitrogen charged and
capped.
Bin & adapter list:
• B322S – no adapter needed
• B330P – Use KBT27
• B530P – Use KBT27
• B530S – Use KBT27
• B842S – Use KBT39
• B948S - Use KBT38 for a single unit
• B948S – Use KBT38-2X for two units side by side
BH1100, BH1300 and BH1600 upright bins include
ller panels to accommodate a single 22 inch wide
ake or nugget ice machine. No adapter is needed.
Scotsman ice systems are designed and
manufactured with the highest regard for safety and
performance.
Scotsman assumes no liability of responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the use
of any part and/or other components not specically
approved by Scotsman.
Scotsman reserves the right to make design changes
and/or improvements at any time. Specications and
design are subject to change without notice.
October 2014
Page 4
Page 5
N0922L, N1322L, F1222L, F1522L
D Series Remote Low Side User Manual
Cabinet Layout
21.81
55.4
18.81
47.8
13.35
1.59
4
BACK VIEW
2.63
3/4" FPT DRAIN
33.9
6.7
CONNECTION
3/8"FLARE
MACHINE
WATER INLET
3/8" O.D. REMOTE
LIQUID LINE
14.36
36.5
120 VOLT CORD
5/8" O.D. REMOTE
SUCTION
CONNECTION
16.86
42.8
LEFT SIDE VIEW
24.00
61
27.00
[68.6]
4.30
4.30
10.9
10.9
6.48
6.48
16.5
16.5
2.81
2.81
7.1
7.1
ICE DROP
OPENING
2.92
2.92
7.4
7.4
16.50
16.50
41.9
41.9
24.00
24.00
REF.
REF.
61
61
PLAN VIEW
ULTRA SONIC
BIN LEVEL
SENSOR
OPTIONAL
12.50
12.50
31.8
31.8
22.00
22.00
REF.
REF.
55.9
55.9
FRONT VIEW
22.00
55.9
22.70
57.7
October 2014
Page 5
Page 6
N0922L, N1322L, F1222L, F1522L
D Series Remote Low Side User Manual
Unpacking
Remove the carton from the skid. Check for hidden
freight damage, notify the carrier immediately if any is
found. Retain the carton for the carrier’s inspection.
The machine is not bolted to the skid. If strapped
remove the strap.
Place on Bin or Dispenser
If reusing an existing bin, be sure that the bin is in
good shape and that the gasket tape on the top is not
torn up. Water leaks, not covered by warranty, could
result from a poor sealing surface. Because this is a
remote low side, a new bin is recommended due to
the high cost to the user of replacing an old bin when
a remote system is on top.
Install the correct adapter, following the directions
supplied with that adapter.
Hoist the machine onto the adapter.
Note: The machine is heavy! Use of a mechanical lift
is recommended.
Panel Removal
Position the machine on the bin or adapter. Secure
with straps from the hardware bag packed with the
machine, or those supplied with the adapter.
Remove any plastic covering the stainless steel
panels.
Remove any packaging, such as tape or foam blocks,
that may be near the gear reducer or ice chute.
Level the bin and ice machine front to back and left to
right by using the bin leg levelers.
1. Locate and loosen the two screws at the bottom
edge of the front panel.
2. Pull the front panel out at the bottom until it clears
the bin.
3. Lower the front panel down and off the machine.
4. Remove two screws at the front of the top panel.
Lift up the front of the top panel, push the top panel
back an inch, then lift to remove.
5. Locate and loosen the screw holding each side
panel to the base. Left side panel also has a screw
holding it to the control box.
6. Pull the side panel forward to release it from the
back panel.
October 2014
Page 6
Page 7
N0922L, N1322L, F1222L, F1522L
D Series Remote Low Side User Manual
Water
The water supply for ice making must be cold, potable
water. There is a single 3/8” male are potable water
connection on the back panel.
Backow
The design of the oat valve and reservoir prevents
potable water backow by means of a 1" air gap
between the reservoir's maximum water level and the
oat valve water inlet orice.
Drain
There is one ¾” FPT condensate drain tting at the
back of the cabinet.
Tubing
Connect the potable water
supply to the potable water
tting, 3/8” OD copper tubing or
the equivalent is recommended.
Connect the drain tube to the
condensate drain tting. Vent this
drain tube.
Do not Tee ice machine drains
into the drain tube from the ice
storage bin or dispenser. Back
ups could contaminate and
/ or melt the ice in the bin or
dispenser.
Follow all local and national
codes for tubing, traps and air
gaps.
Potable Water Inlet
Condensate Drain
October 2014
Page 7
Page 8
N0922L, N1322L, F1222L, F1522L
D Series Remote Low Side User Manual
Electrical
The machine includes a power cord, connect
to the proper power supply. A separate circuit is
recommended to avoid unintended shut downs.
If a dedicated condensing unit is connected to this
machine, it will have a separate power supply.
Do not use an extension cord.
Follow all local and national codes.
ModelDimensions
Voltage
Min Circuit Ampacity Max Fuse Size
(cord connected)
w" x d" x h"
Volts/Hz/Phase
All 22 x 24 x 27 115/60/1 5.8 15
Power Cord
3/8 OD Liquid Line Stub
5/8 OD Suction
Line Stub
October 2014
Page 8
Page 9
N0922L, N1322L, F1222L, F1522L
D Series Remote Low Side User Manual
Refrigeration
BTUH Capacity Requirements
Model BTUH
N0922L, F1222L 5,000
N1322L, F1522L 7,200
Condensing Units
Model Use Condensing Unit
N0922L or F1222L NME954-RHS-A/C
N1322L or F1522L None - rack only
Remote low side models require connection to a
dedicated condensing unit or a rack system.
Recommended Tubing from Head to Condensing Unit
• Suction Line: 5/8" OD
• Liquid Line: 3/8" OD
Distance limits:
• Maximum distance between dedicated condensing
unit and head: 75 feet.
• Condensing Unit Elevation over Ice Making
Section: 35 feet.
Note: Elevations greater than 20 feet require
installation of a suction line trap at the 10 foot mark.
Ice Making Section
• Elevation over Condensing Unit: 15 feet.
Refrigeration Installation:
Connections
The liquid and suction ttings on the back of the
cabinet are stubs. The liquid line size is 3/8" OD. The
suction line size is 5/8" OD.
1. Recover holding charge
2. Cut the stubs off.
3. Braze line set tubing to each tting. Sweep with
dry nitrogen while brazing.
4. Dedicated condensing unit: Evacuate complete
system to 50 microns.
5. Open the ball valves.
Rack: The skills of a refrigeration technician are
required to connect the ice machine to the building’s
refrigeration system.
Notes:
• R-404A models: 1.5 ounces of R-404A refrigerant
is in the system as a holding charge.
• Be sure the liquid connection is NOT in series with
another liquid line valve.
Install and attach the remote condensing unit to the
roof of the building, using the methods and practices
of construction that conform to the local building
codes, including having a roong contractor secure
the condenser to the roof.
October 2014
• N0922L or F1222L: 8 lb R-404A
• N1322L of F1522L: n/a - rack only
Page 9
Page 10
N0922L, N1322L, F1222L, F1522L
D Series Remote Low Side User Manual
Final Check List
After Connections
1. Wash out the bin. If desired, the interior of the bin
could be sanitized.
2. Locate the ice scoop (if supplied) and have it
available for use when needed.
Final Check List:
1. Is the unit located indoors in a controlled
environment?
2. Is the unit located where it can receive adequate
cooling air?
3. Has the correct electrical power been supplied to
the machine?
4. Have all the water supply connections been
made?
5. Have all the drain connections been made?
6. Has the unit been leveled?
Control Operation
Use and Operation
Once started, the ice machine will automatically make
ice until the bin or dispenser is full of ice.
When ice level drops, the ice machine will resume
making ice.
Caution: Do not place anything on top of the ice
machine, including the ice scoop. Debris and moisture
from objects on top of the machine can work their way
into the cabinet and cause serious damage. Damage
caused by foreign material is not covered by warranty.
There are four indicator lights at the front of the
machine that provide information on the condition of
the machine.
Indicator Lights:
• Power
• Status
Switch Door
7. Have all unpacking materials and tape been
removed?
8. Is the correct switch bezel installed in the trim
strip?
9. Is the water pressure adequate?
10. Have the drain connections been checked for
leaks?
11. Has the bin interior been wiped clean or sanitized?
12. Have any water lter cartridges been replaced?
13. Have all required kits and adapters been properly
installed?
14. Has the ice machine been properly connected to
the condensing unit or rack?
• Water
• De-scale &
Sanitize
Under the door are two switches – On and Off. To
switch the machine OFF, push and release the Off
button. The machine will shut off at the end of the next
cycle.
To switch the machine ON, push and release the
On button. The machine will go through a start up
process and then resume ice making.
October 2014
Page 10
Page 11
N0922L, N1322L, F1222L, F1522L
D Series Remote Low Side User Manual
Initial Start Up
1. Turn the water supply on.
2. Switch the electrical power on. Conrm voltage is
correct for the model.
3. Push and release the On button. The machine will
start up in about two minutes.
The liquid line valve will open and liquid refrigerant
will ow into the machine. For the units connected to
a dedicated condensing unit, the resulting increase in
suction pressure will start the condensing unit and the
condensing unit will begin discharging warm air from
the remote condenser. After about 5 minutes, ice will
begin to drop into the bin or dispenser.
4. Check the machine for unusual rattles.
5. Tighten any loose screws, be sure no wires are
rubbing moving parts. Check for tubes that rub.
6. Check suction pressure, adjust EPR setting. As
shipped the EPR valve should maintain low side
pressure at about 36 PSIG + or - 2 PSIG.
Note: Machines will operate and make ice at the
factory EPR setting. For optimum performance, adjust
the EPR to the settings in the chart below:
• All models require sensor cleaning.
• All models require a top bearing check.
Maintenance Frequency:
Scale removal. At least twice a year, in some water
conditions it might be every 3 months. The yellow De-
Scale & Sanitize light will switch on after a set period
of time as a reminder. The default time period is 6
months of power up time. There are 4 available time
period intervals: 1 year, 0 or disabled, 6 months or 4
months.
Sanitizing: Every time the scale is removed or as
often as needed to maintain a sanitary unit.
Sensor Cleaning: Every time the scale is removed.
Top bearing check: At least twice a year or every time
the scale is removed.
Maintenance: Remote air cooled condenser
The condenser ns will occasionally need to be
cleaned of leaves, grease or other dirt. Check the coil
every time the ice machine is cleaned.
Maintenance: Exterior Panels
Model
Number
N0922L /
Scotsman
Rack
Condensing Unit
Full open 30 PSIG
F1222L
N1322L /
Not specied 26 PSIG
F1522L
Superheat will be 12
o
F, + or - a few degrees.
7. Fill out the warranty registration form and either
le it on line or mail it.
8. Notify the user of the maintenance requirements
and whom to call for service.
Maintenance
This ice machine needs ve types of maintenance:
• Remote condensing units need their condenser coils
cleaned regularly.
• All models need scale removed from the water
system.
The front and side panels are durable stainless steel.
Fingerprints, dust and grease will require cleaning
with a good quality stainless steel cleaner
Note: If using a sanitizer or a cleaner that contains
chlorine on the panels, after use be sure to wash the
panels with clean water to remove chlorine residue.
Maintenance: Water lters
If the machine has been connected to water lters,
check the cartridges for the date they were replaced
or for the pressure on the gauge. Change cartridges
if they’ve been installed more than 6 months or if the
pressure drops too much during ice making
• All models require regular sanitization.
October 2014
Page 11
Page 12
N0922L, N1322L, F1222L, F1522L
D Series Remote Low Side User Manual
Scale removal
Note: Following this procedure will reset the de-scale
and sanitize light.
1. Remove front panel.
2. Push and release the Off button.
3. Remove ice from bin or dispenser.
4. Turn the water supply to the ice machine OFF.
5. Drain the water and evaporator by disconnecting
the leg of the hose connected to the water sensor
and draining it into the bin. Return the hose to its
original position.
6. Remove the water reservoir cover.
7. Mix a solution of 8 ounces of Scotsman Clear One
Scale Remover and 3 quarts of 95-115 degree F.
potable water.
Scotsman Ice Machine
Cleaner contains acids. ese
compounds may cause burns.
If swallowed, DO NOT
induce vomiting. Give large
amounts of water or milk.
Call Physician immediately.
In case of external contact,
ush with water.
KEEP OUT OF THE
REACH OF CHILDREN
8. Pour the scale remover solution into the reservoir.
Use a small cup for pouring.
Discard or melt all ice made during the previous
step.
13. To sanitize the water system, mix a locally
approved sanitizing solution. An example of a
sanitizing solution is mixing one ounce of liquid
household bleach and two gallons of 95 – 115
degree F. water.
14. Pour the sanitizing solution into the reservoir.
15. Push and release the On button.
16. Switch the water supply to the ice machine on.
17. Operate the machine for 20 minutes.
18. Push and release the Off button.
19. Wash the reservoir cover in the remaining
sanitizing solution.
20. Return the reservoir cover to its normal position.
21. Melt or discard all ice made during the sanitizing
process.
22. Wash the inside of the ice storage bin with the
sanitizing solution.
23. Push and release the On button.
24. Return the front panel to its original position and
secure with the original screws.
9. Push and release the Clean button: the auger
drive motor and light are on, C is displayed and
the De-scale light blinks. After 20 minutes the
compressor will start.
10. Operate the machine and pour the scale remover
into the reservoir until it is all gone. Keep the
reservoir full. When all the scale remover solution
has been used, turn the water supply back on.
After 20 minutes of ice making the compressor
and auger motor will shut off.
11. Turn the water supply to the ice machine OFF
12. Drain the water reservoir and evaporator by
disconnecting the leg of the hose connected to
the water sensor and draining it into the bin or a
bucket. Return the hose to its original position.
October 2014
Page 12
Page 13
N0922L, N1322L, F1222L, F1522L
D Series Remote Low Side User Manual
Check Top Bearing
This task should only be done by a qualied service
technician
The bearing in the breaker should be checked at least
two times per year.
Check the bearing by:
1. Removing the bail clamp and ice chute cover
Bail Clamp
3. Removing the water shed & unscrewing the
breaker cover (left hand threads).
2. Unscrewing the ice sweep
4. Inspect the top of the bearing. When new the
grease is white, over time some gray will appear
over the rollers, that is normal. Add grease to
replace gray grease or if gaps between rollers
are visible. If grease is watery, all gray or rust is
visible, have the bearing replaced. See the next
page for more information.
Note: When checking the top bearing, always inspect
the drip pan for water seal leaks. If water is present
in the drip pan, service the water seal and check the
gear reducer's lubricant. See the next page.
October 2014
Page 13
Page 14
N0922L, N1322L, F1222L, F1522L
D Series Remote Low Side User Manual
Bearing Service
This task should only be done by a qualied service
technician
If the bearing only needs grease, or to conrm the
quality of the grease low in the bearing, inject grease
into the lower part of the bearing using Scotsman
Drip Pan
grease needle pn 02-3559-01 and Scotsman bearing
grease cartridge, pn A36808-001. Be sure to inject
grease evenly and thoroughly.
Bearing
Needle, pn 02-3559-01
Check Drip Pan For Water
Change De-Scale Notication Interval
This feature is accessible only from standby
(Status Light Off).
1. Press and hold Clean button for 3 seconds.
Starts the Time to Clean Adjustment State and
displays the current time to clean setting.
2. Press the clean button repeatedly to cycle through
the 4 possible settings:
If the grease is uniformly white, no further action is
needed. If very gray, rusty, wet or has any embedded
metal, have the bearing replaced.
October 2014
Page 14
• 1 year (8760 hours)
• 0 (disabled)
• 4 months (2920 hrs)
• 6 months (4380 hours) (default)
Page 15
N0922L, N1322L, F1222L, F1522L
D Series Remote Low Side User Manual
Options
Vari-Smart
Optional adjustable ice level control (KVS)
When this option is present there is an adjustment
post and an additional indicator light to the right of the
four indicator lights mentioned earlier. The ultrasonic
ice level control allows the user to control the point
that the ice machine will stop making ice before the
bin or dispenser is full. Reasons for this include:
• Seasonal changes in ice used
• Planning to sanitize the bin
• Faster turnover for fresher ice
Dispenser applications -
Nugget ice only:
Set the adjustment knob to either the rst or second
position CW after the maximum ll position.
• Certain dispenser applications where maximum ice
level is not desired
There are several positions
the ice level can be set to,
including Off (knob and label
indicators lined up), where it
lls the bin until the standard
bin control shuts the machine
off. See the kit’s instructions
for complete details.
Rotate the adjustment post
to the desired ice level. The
machine will ll up to that
level and when it shuts off
the indicator light next to the
adjustment post will be On.
Note: The maximum ll position is when the arrow on
the knob points to the arrow on the label
October 2014
Page 15
Page 16
N0922L, N1322L, F1222L, F1522L
D Series Remote Low Side User Manual
Service Diagnosis
Symptom Probable Cause Possible Correction
No ice No powerCheck that ice machine and
condensing unit, if used, both have
power. If power light is out, check
transformer.
Code 3: No water Restore water
Status light is off Push and release ON switch
Code 1: No ice sensedCheck for ice ow down chute. if
very slow or no ice being made,
check water inlet tubing for
restriction; check for condensing
unit or refrigeration system failure
Check auger motor for power, if no
power, check controller component
indicator light. If there is power to
the motor, check motor windings
Code 2: Auger motor draws too
many amps, controller shuts unit
off.
Bin Eyes Blocked light is OnIce is in the chute.
Everything is in operation, but no
refrigeration effect
Low ice making capacity Scale build upRemove scale from evaporator and
Restricted water supply to
evaporator
Suction tubing kinked Check suction tubing
Expansion valve superheat
incorrect
Check that liquid line valve shuts
off tightly
Check for damage to gear reducer
or auger bearings.
No ice in the chute. Check position
of sensors, check sensors for scale
build up
Check liquid line valve
Check condensing unit
Check TXV
Check refrigerant charge
water system
Squeeze hose, if bubbles appear
revise hose and reservoir
Check superheat
October 2014
Page 16
Page 17
N0922L, N1322L, F1222L, F1522L
D Series Remote Low Side User Manual
What to do before calling for service
Normal Operation
Ice
The machine will make either aked or nugget ice,
depending upon the model. The ice will be produced
continuously until the bin is full.
Heat
Most heat is exhausted at the remote condensing unit
or at the rack; the ice machine should not generate
signicant heat.
Noise
The ice machine will make noise when it is in ice
making mode. The gear reducer will produce sound.
Some ice making noise could also occur. These
noises are all normal for this machine.
Reasons the machine might shut itself off:
• Lack of water.
• Does not make ice
• Auger motor overloaded
2. Has power been shut off to the ice machine? If yes,
the ice machine will automatically restart when
power is restored.
3. Has someone shut the power off to the remote
condensing unit while the ice machine still had
power? If yes, the ice machine may need to be
manually reset.
To Manually Reset the machine.
• Open the switch door
• Push and release the Off button.
• Push and release the On button.
To Shut the Machine Off:
1. Push and hold the Off button for 3 seconds or until
the machine stops
Open
Switch
Door
• Controller self test failure.
Check the following:
1. Has the water supply to the ice machine or
building been shut off? If yes, the ice machine will
automatically restart within minutes after water begins
to ow to it.
.
Indicator Lights & Their Meanings
Light Actions Power Status Water De-Scale & Sanitize
Steady Green Normal Normal - Blinking Green Self Test Failure Switching on or
off. When Smart-
Board used,
machine attention
recommended.
Blinking Red - Diagnostic shut
down
Yellow - - - Time to descale and
Blinking Yellow - - - In Cleaning Mode
Light Off No power Switched to Off Normal Normal
- -
Lack of water -
sanitize
October 2014
Page 17
Page 18
SCOTSMAN ICE SYSTEMS
775 Corporate Woods Parkway
Vernon Hills, IL 60061
800-726-8762
www.scotsman-ice.com
17-3532-01
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.