Scotsman C2148 Installation Manual

Installation and User’s Manual
Models C1448, C1848, C2148W
C1448, C1848, C2148W Air and Water Cooled User Manual
Introduction
The design of this modular cuber is the result of years of experience and testing. Standard features include front accessible indicator lights and on-off switches that provide the user with fast access to critical information and easy operational control.
When desired, optional controls can add features like ultrasonic bin ice level sensing, seven day programmable bin ice level setting, remote lock out and more.
Contents
Installation: Product Specications ................................................... Page 2
Product Information ............................................................... Page 3
Product Description & Electrical Requirements .......................................... Page 4
Cabinet Layout, Air Cooled ......................................................... Page 5
Cabinet Layout, Water Cooled ...................................................... Page 6
Water .......................................................................... Page 7
This installation and user manual is divided into three main sections: Installation, which provides the trade person with the information needed to set up and install this product; Use and Operation, which provides the user with the information to use the product; and Maintenance, which provides the user with the information needed keep it operating
efciently.
Panel Removal .................................................................. Page 8
Uncrate and Set Up ............................................................... Page 9
Plumbing Requirements ........................................................... Page 10
Drains ......................................................................... Page 11
Electrical ....................................................................... Page 12
Final Check List .................................................................. Page 13
Initial Start Up ................................................................... Page 14
Adjustments ..................................................................... Page 15
Water ush setting ................................................................ Page 16
Use and Operation ............................................................... Page 17
Switches ....................................................................... Page 18
Options and Other Information ...................................................... Page 19
Cleaning, Sanitation and Maintenance ................................................ Page 20
Air cooled condenser lter .......................................................... Page 22
What to do before calling for service .................................................. Page 23
November 2006
Page 1
C1448, C1848, C2148W Air and Water Cooled User Manual
Installation: Product Specications
Location Limitations: The product is designed to be installed indoors, in a controlled environment. Air cooled models discharge very warm air into the room out the back. Space must be allowed at the left side and back for air intake and discharge.
Water cooled models discharge warm water into the building’s drain. Space needs to be provided on both sides and above for service access.
Space Limitations
Note: Although the machine will function, ice capacity
of air cooled machines will be signicantly reduced
with minimal clearance at the sides, back and top. Some space is recommended for service and maintenance purposes on all models.
6" of space at the sides and back are required for adequate operation. To get the most capacity, locate the machine away from heat producing appliances and heating ducts. Provide several feet of space to the left for maximum ice capacity.
Environmental Limitations
Minimum Maximum Air temperature 50oF. 1 100oF. Water
temperature Water pressure 20 psi 80 psi
Power supply – acceptable voltage ranges
208-230 volt model
Warranty Information
The warranty statement for this product is provided separately from this manual. Refer to it for applicable coverage. In general warranty covers defects in material or workmanship. It does not cover maintenance, corrections to installations, or situations when the machine is operated in circumstances that exceed the limitations printed above
40oF. 100oF.
Minimum Maximum
198 volts 253 volts
Walls or other large machines near to the ice machine might also cause a reduction in ice capacity. One foot behind and two feet above will be required to make rated capacity.
Airow is in the front, in the left side, out the back (as
viewed from the front).
Airow
November 2006
Page 2
C1448, C1848, C2148W Air and Water Cooled User Manual
Product Information
The product is a modular cuber. That type of machine is designed to be placed on an ice storage bin or an ice dispenser. Many installations only require the matching bin, but some also require an adapter to be placed between the bin and the cuber or between the dispenser and the cuber.
This product cannot be stacked. See the chart for application information.
Model Number Description
Example:
C1448SA-32B
C= cuber
14= nominal ice capacity in 100s of pounds
48= nominal width of cabinet
S= Cube size. S=small or half dice cube.
M=medium or full dice cube
Some installations require bin adapters. See the table below.
Standard Bin Applications - Adapter information.
Model BH900*, B948S BH1100,
BH1300, BH1600
C1448, C1848, C2148
* Note. If previously equipped with stainless steel
bafe, KBAFFLE3, remove and replace with original plastic bafe.
Other Bins & Applications:
Note the drop zone and ultrasonic sensor locations in the illustrations.
Scotsman ice systems are designed and manufactured with the highest regard for safety and performance. They meet or exceed the standards of UL and NSF.
Direct Fit, no
adapter needed
No adapter needed
A=Condenser type. A=air cooled. W=water cooled
-32=Electrical code. -32=208-230 single phase.
-3=208-230 three phase
B=Series revision code. B=2nd series
Note: In some areas of this manual model numbers
may include only the rst ve characters of the model
number, meaning that the cube size, condenser type and voltage differences are not critical to the information listed there.
Options:
There are several eld-installed options that can be installed at initial start up or later. They include: • KVS
- Vari-Smart adjustable ice level system.
• KSBU - Smart-Board advanced feature control.
• A39515-021 air bafe to reduce air recirculation
around the back of the cabinet when installed in a corner.
Scotsman assumes no liability of responsibility of any kind for products manufactured by Scotsman that have been altered in any way, including the use
of any part and/or other components not specically
approved by Scotsman.
Scotsman reserves the right to make design changes
and/or improvements at any time. Specications and
design are subject to change without notice.
December 2011
November 2006
Page 3
C1448, C1848, C2148W Air and Water Cooled User Manual
Product Description & Electrical Requirements
Dimensions w” x d” x h”
48 x 24 x 29 C1448SA-32 208-230/60/1 Air 17.7 20 30 same C1448SW-32 208-230/60/1 Water 16.0 20 30 same C1448SA-3 208-230/60/3 Air 13.6 20 30 same C1448SW-3 208-230/60/3 Water 11.9 15 30 same C1848SA-32 208-230/60/1 Air 25.5 30 30 same C1848SW-32 208-230/60/1 Water 23.8 30 30 same C1848SA-3 208-230/60/3 Air 16.5 20 30 same C1848SW-3 208-230/60/3 Water 14.8 20 30 same C2148SW-32 208-230/60/1 Water 22.2 30 30 same C2148SW-3 208-230/60/3 Water 18.0 20 20
Table notes: Medium cube models have the same electrical characteristics as Small. Series revision code omitted.
* Or HACR type circuit breakers.
This manual covers several models. The model number on the product is located in two places, on the back dataplate and on the model and serial number tag, located behind the front panel.
Model Electrical Condenser Minimum
Circuit Ampacity
Suggested Fuse Size
Maximum Fuse Size*
Write the model and serial number of this product here:
_________________________________________
August 2008
November 2006
Page 4
C1448, C1848, C2148W Air and Water Cooled User Manual
Cabinet Layout, Air Cooled
REF.
24.00
5.1
2.00
9.00
22.9
57.8
22.75
MINIMUM BIN
9.63
24.5
TOP OPENING
46.5
18.30
ICE DROP OPENING
2.3
.92
48.00
121.9
2.3
.92
61
FRONT VIEW
LOUVER AND
24.00
REMOVABLE FILTER
AC UNITS ONLY
48.89
48.00 REF.
124.2
PLAN VIEW
73.7
29.00
1.57 REFRIGERATION AND ELECTRICAL CHASE
LEFT SIDE VIEW
ACCESS
.88 DIA
ELECTRICAL
61.4
24.18
WATER
3/8" FPT
INLET
November 2006
Page 5
52.2
20.54
45.7
18.00
7.4
2.91
63.2
24.90
3/4" FPT
DRAIN
46.17
117.3
BACK VIEW
AIR COOLED
C1448, C1848, C2148W Air and Water Cooled User Manual
Cabinet Layout, Water Cooled
REF.
24.00
5.1
2.00
9.00
22.9
57.8
22.75
MINIMUM BIN
9.63
24.5
TOP OPENING
46.5
18.30
ICE DROP OPENING
48.89
48.00 REF.
124.2
PLAN VIEW
73.7
29.00
1.57 REFRIGERATION AND ELECTRICAL CHASE
121.9
2.3
61
48.00
FRONT VIEW
.92
24.00
LEFT SIDE VIEW
3/8" FPT (C1448/1848)
4.63
11.7
61.5
24.20
ACCESS
.88 DIA
ELECTRICAL
WATER
3/8" FPT
INLET
November 2006
Page 6
WATER INLET
CONDENSER
1/2" FPT (C2148)
56.1
45.7
22.09
18.00
52.3
20.59
14.3
5.64
9.4
3.70
63.2
7.5
2.96
3/4" FPT
DRAIN
24.90
117.3
CONDENSER
DRAIN
1/2" FPT
46.17
BACK VIEW
WATER COOLED
C1448, C1848, C2148W Air and Water Cooled User Manual
Water
The quality of the water supplied to the ice machine will have an impact on the time between cleanings and ultimately on the life of the product. There are two ways water can contain impurities: in suspension
or in solution. Suspended solids can be ltered out. In solution or dissolved solids cannot be ltered, they must be diluted or treated. Water lters are
recommended to remove suspended solids. Some
lters have treatment in them for suspended
solids. Check with a water treatment service for a recommendation.
Scotsman lters:
A triple head lter is recommended for the potable water. Either the Scotsman SSM3 taste and odor lter
system, or the ADS-AP3 Aqua Patrol system. RO water. This machine can be supplied with Reverse Osmosis water, but the water conductivity must be no less than 10 microSiemens/cm.
Condenser Water Supply - ltration not recommended
for this water supply
Additionally, devices intended to enhance ice machine sanitation, such as the Scotsman Aqua Bullet, can be placed in the machine to keep it cleaner between manual cleanings
Water Flush
Cube ice machines use more water than what ends up in the bin as ice. While most water is used during ice making, a portion is designed to be drained out every cycle to reduce the amount of hard water scale
in the machine. That’s known as water ush, and an effective ush can increase the time between needed
water system cleaning.
In addition, this product is designed to automatically
vary the amount of water ushed based on the purity of the water supplied to it. The water ush rate can
also be set manually.
Adjustments of ush due to local water conditions are
not covered by warranty.
GPH, 70 degree water C1448W 70 C1848W 106 C2148W 1 10
Potential for Airborne Contamination
Installing an ice machine near a source of yeast or similar material can result in the need for more frequent sanitation cleanings due to the tendency of these materials to contaminate the machine.
Most water lters remove chlorine from the water
supply to the machine which contributes to this
situation. Testing has shown that using a lter that
does not remove chlorine, such as the Scotsman Aqua Patrol, will greatly improve this situation, while the ice making process itself will remove the chlorine from the ice, resulting in no taste or odor impact.
November 2006
Page 7