Scotsman C0600CP-3 Parts List

Page 1
Prodigy Eclipse 600, 800, 1000 Service Parts
This part list contains the service parts for the Eclipse 600, 800 and 1000 systems. The B series references changes to panels. The models that are covered include:
• EH222 - head
Head voltage is independent of the condensing unit voltage. Voltage codes:
-1 = 115/60/1
-3 = 208-230/60/3
-6 = 230/50/1
-32 = 208-230/60/1
• ERC680 - condenser, one circuit
• ERC1086 - condenser, one circuit
• ER2C6810 - condenser, two circuits
Contents
EH222 Cabinet - A Series ................................................................................................. Page 2
EH222 Cabinet - B Series ................................................................................................. Page 3
Back Panel Assembly ...................................................................................................... Page 4
EH222 Interior Parts ......................................................................................................... Page 5
EH222 Water System ........................................................................................................ Page 6
EH222 Refrigeration ......................................................................................................... Page 7
EH222 Electrical ................................................................................................................ Page 8
C0600CP, C0800CP and C1410CP Cabinet ..................................................................... Page 9
C0600CP, C0800CP and C1410CP Refrigeration Components .................................... Page 10
C0600CP, C0800CP and C1410CP Compressors .......................................................... Page 11
C0600CP, C0800CP and C1410CP Control Box ............................................................ Page 12
C0600CP, C0800CP and C1410CP Condensers ............................................................ Page 13
EH222 Schematic Diagram ............................................................................................. Page 14
EH222 Wiring Diagram .................................................................................................... Page 15
C0600CP, C0800CP and C1410CP Single Phase Schematic Diagram ........................ Page 16
C0600CP, C0800CP and C1410CP Single Phase Wiring Diagram ............................... Page 17
C0600CP, C0800CP and C1410CP Three Phase Schematic Diagram ......................... Page 18
C0600CP, C0800CP and C1410CP Three Phase Wiring Diagram ................................ Page 19
50 Hz Model Wiring and Schematic Diagram ................................................................ Page 20
July 2012
Page 1
Page 2
10
Prodigy Eclipse 600, 800, 1000 Service Parts
EH222 Cabinet - A Series
1b
1
12
11
9
8
8a
7
13
6
4a
3
1a
2a
14
2
1
3
Item Part Number Number Description
1 A39074-021 Top panel 1a 02-4221-04 Trim strip 1b 02-4221-03 Trim strip 2 A38553-023 Right side panel, includes item 3 3 02-4067-03 Side panel support 4 02-4341-01 Evaporator cover 4a 03-0727-05 Thumb screw 5 02-4324-01 Insulation 6 02-4217-01 Bottom gusset 7 02-4284-01 Bezel, full window 8 02-4214-01 Trim strip 8a 03-1735-03 Screw
9 02-4284-02 Bezel, partial window 10 A39209-001 Machine strap 11 16-1036-01 Flare union 12 A38551-025 Left side panel, includes item 3 13 A38552-026 Front panel, includes items 5, 8, 6, 15 and 7 14 02-4216-01 Upper gusset
July 2012
Page 2
Page 3
Prodigy Eclipse 600, 800, 1000 Service Parts
EH222 Cabinet - B Series
1b
8a
10
11
9
14
8
7
15
15a
19
12
18
4a
4
1
1a
15b
16
13
Item Part Number Number Description
1 A39074-021 Top panel 1a 02-4221-04 Trim strip* 1b 02-4221-03 Trim strip* 2 A39589-021 Right side panel, 60 Hz A39589-022 Right side panel, 50 hz 3 A39571-001 Panel clip 4 02-4341-01 Evaporator cover 4a 03-0727-05 Thumb screw 5 02-4324-01 Insulation 6 02-4217-01 Bottom gusset 7 02-4284-01 Bezel, full window*** 8 02-4214-01 Trim strip 8a 03-1735-03 Screw 9 02-4284-02 Bezel, partial window** 10 A39209-001 Machine strap 11 16-1036-01 Flare union
16
5
3
12 A39580-025 Left side panel, 60 Hz A39580-027 Left side panel, 50 hz 13 A39578-026 Front panel, includes items 5, 8, 6, 15 and 7 14 02-4216-01 Upper gusset 15 02-4215-01 Receptacle 15a 03-3804-01 Screw receptacle 15b 03-3836-02 Screw, hi-lo 16 03-1733-04 Catch^ 17 03-1733-01 Strike^ 18 03-1531-08 Screw^ 03-1417-27 Washer^ 19 03-1404-12 Screw * Side trim strips discontinued mid 2011. ** Item 9 assembled to front panel and item 7 shipped loose, mid 2011. *** Item 7 discontinued from production 2/8/2012. ^ 50 Hz model only
2
July 2012
Page 3
Page 4
Prodigy Eclipse 600, 800, 1000 Service Parts
Back Panel Assembly
3
6
5
7
1
3
2
4
Item Part Number Number Description
1 A39070-001 Top panel bracket 2 12-2922-01 Inlet water sol valve, 60 Hz 2a 11-0568-02 Inlet water sol valve, 50 Hz 3 02-4067-05 Panel support 4 13-0674-02 Tube, use 16 in 5 A39065-001 Back panel, A series A39664-001 Back panel, B series 6 02-4290-01 Vent hose Not shown
7 02-4716-01 Water inlet tube, 50 Hz only
2a
July 2012
Page 4
Page 5
Prodigy Eclipse 600, 800, 1000 Service Parts
EH222 Interior Parts
1
9
7
8
5
3
6
2
3
4
10
Item Part Number Number Description
1 A39078-001 Bracket 2 02-4065-01 Water distributor cover 3 02-4205-02 Mounting bracket 4 02-4297-01 Evap side cover 5 02-4343-01 Controller box 6 02-4611-21 Curtain only (articulated) for units after sn 10101320010556 or those using articulated curtain A39843-001 Curtain kit, includes magnet and curtain switch 6a 11-0563-02 Magnet for single part curtain - single part curtains only 7 A39053-021 Evaporator, small cube A39053-022 Evaporator, med cube 8 A39031-021 Ice thickness sensor 9 02-4064-02 Water distributor 10 A39054-001 Left surround A39056-001 Right surround
July 2012
Page 5
Page 6
Prodigy Eclipse 600, 800, 1000 Service Parts
EH222 Water System
16
11
10
13
14
18
12
9
17
8
15
19
7
5
Item Part Number Number Description
1 A39277-001 Chase cover 2 11-0564-01 Purge valve 3 11-0563-03 Curtain switch 4 A39232-002 Drain hose 5 02-3692-21 Drain adapter 6 16-1099-01 Fitting 7 16-1134-01 Elbow 8 16-1099-02 Coupling, pvc 9 02-4332-01 Sensor cover, prior
9a 02-4646-01 Sensorguard,ts10a  10 02-4291-01 Pumpbracket-ts9
10a 02-4650-01 Pump bracket for sensor guard, use began w/11121320011187. Fits 9a 11 12-2920-24 Water pump, 60 Hz 12-2920-25 Water pump, 50 Hz
1
2
3
4
5
KVS sensor, order
KVS to replace it.
12 A39030-021 Water level sensor 13 02-4292-01 Sump cover 14 02-4286-01 Pump hose 15 02-4296-01 Hose cover 16 12-3060-21 Harvest assist sol, 60 Hz 12-3060-22 Harvest assist sol, 50 Hz 17 A39232-001 Drain tube, inlet 18 11-0515-21 Water temp sensor 19 02-4290-01 Drain and vent tube
April 2013
July 2012
Page 6
Page 7
Prodigy Eclipse 600, 800, 1000 Service Parts
EH222 Refrigeration
1
6
5
4
Item Part Number Number Description
1 16-0850-01 Quick connect, vapor 2 16-1063-01 Strainer - discontinued 2012 3 11-0493-02 Vapor solenoid valve - 60 Hz 11-0491-01 Vapor solenoid valve, - 50 Hz 4 16-1142-01 TXV 4a 02-4405-01 Insulation, TXV 5 16-0850-04 Quick connect, suction
6 16-0850-03 Quick connect, liquid
2
3
July 2012
Page 7
Page 8
Prodigy Eclipse 600, 800, 1000 Service Parts
EH222 Electrical
1a
1
1
3
2
Item Part Number Number Description
4,5,6
1 12-2949-01 Relay, 60 Hz 12-2949-03 Relay, 50 Hz 1a 12-2949-02 Relay base 2 12-2924-01 Transformer, 60 Hz 12-2639-01 Transformer, 50 hz 3 12-2780-01 Terminal strip 4 11-0550-28 Controller 5 02-4189-01 Overlay label 6 02-4076-01 Control box door 7 KVS Vari-Smart control, complete with sensor 8 12-2686-01 Fuse, 50 Hz only 9 12-2687-01 Fuse holder, 50 Hz only Not shown: 10 12-1638-19 Power cord, 60 Hz 12-1638-25 Power cord, 50 Hz 11 12-2957-01 High voltage harness, 60 Hz 12-3074-02 High voltage harness, 50 Hz 12 12-2954-01 Low voltage harness, 60 Hz 12-3072-01 Low voltage harness, 50 Hz 13 12-2928-01 Water level sensor harness
July 2012
Page 8
8
9
7
Page 9
Prodigy Eclipse 600, 800, 1000 Service Parts
C0600CP, C0800CP and C1410CP Cabinet
1
2
1
3
4
8
9
7
1
4
10
11
9
6
1
4
1
4
5
Item Part Number Number Description
1 03-1645-01 Screw 2 A37853-001 Top cover 3 A37845-001 Back panel 4 03-1531-01 Screw 5 A37829-001 Right side panel 6 12-1213-20 Snap bushing 7 A37896-001 Front cover 8 A37829-002 Left side panel 9 A37962-001 Service valve bracket 10 A37948-001 Receiver or accumulator bracket 11 A37949-001 Receiver top bracket
12 A38430-001 Control box cover
July 2012
Page 9
Page 10
Prodigy Eclipse 600, 800, 1000 Service Parts
C0600CP, C0800CP and C1410CP Refrigeration Components
16
1
17
18
5
15
2
6
3
4
5
7
8
9
1
2
10
Compressors,seenextpage
Item Part Number Number Description
1 16-0701-14 Mountingange  2 16-0850-01 Malequickconnect-discharge  3 16-0701-07 Mountingange  4 16-0850-03 Malequickconnect-liquid  5 16-0832-20 Accessvalve  6 02-3231-02 Filter  7 11-0546-01 Liquidinletvalve(N.O.)  8 A37949-001Topbracket  9 16-1085-01 Receiver  10 A37948-001Bottombracket
11
3
4
13
12
10
14
11 02-3319-02 Filterdryer  12 16-0801-22 Suctionaccumulator  13 16-0701-18 Mountingange  14 16-0850-04 Malequickconnect-suction  15 11-0501-22 Hipresscutout  16 16-1096-21 CPRvalve  17 11-0507-03 Bypasssolenoidvalve  18 11-0422-22 Headmaster
July 2012
Page 10
Page 11
Prodigy Eclipse 600, 800, 1000 Service Parts
C0600CP, C0800CP and C1410CP Compressors
Compressor - see table below
CP Model Phase Hz Part Number
C0600CP-32 single 60 18-8768-22 C0600CP-3 three 60 18-8768-24 C0800CP-32 single 60 18-8813-23 C0800CP-3 three 60 18-8813-25 C0800CP-6 single 50 18-8749-27 C1410CP-32 single 60 18-8749-22 C1410CP-3 three 60 18-8749-24
Single phase 60 Hz compressors include starting components. All include a drier. 18-8813 & 18-8749 types include crankcase heaters
18-2308-01 Crankcase heater for 18-8813 and 18-8749 type 12-1868-02 Crankcase heater for 18-8768 type
Mounting parts for 18-8813 and 18-8749 type compressors: 18-2300-27 Mounting grommet 18-2300-26 Sleeve 03-1406-07 Washer 03-1405-20 Cap screw Mounting parts for 18-8768 type compressors: 18-2200-28 Mounting grommet 18-2200-27 Sleeve 03-1406-07 Washer 03-1404-20 Cap screw
Parts Shipped in CP unit: 12-2865-01 75’ Interconnecting harness
July 2012
Page 11
Page 12
Prodigy Eclipse 600, 800, 1000 Service Parts
C0600CP, C0800CP and C1410CP Control Box
1
2
6
3
4
5
Single Phase Control Box
Three Phase Control Box
1
2
7
Item Part Number Number Description
1 12-2637-01 Toggle switch 2 12-1213-20 Snap bushing 3 12-2469-01 Single phase contactor
C0600CP-32 C0800CP-32 C0800CP-6 C1410CP-32
4 Comp. Relay 18-1903-33 18-1903-33 18-1903-33 18-1903-46 5 Start Capacitor 18-1901-54 18-1901-15 18-1901-48 18-1901-48 6 Run Capacitor 18-1902-45 18-1902-53 18-1902-70 18-1902-55
7 12-2533-01 Contactor, 3 phase Not Shown: 8 12-2836-02 Transformer, 60 Hz models 230 volt to 24 volt 12-2639-02 Transformer, 50 Hz models 9 12-2686-01 Fuse, 50 Hz models only 10 12-2687-01 Fuse holder, 50 Hz models only
11 12-2640-01 Terminal block, 50 Hz models only
July 2012
Page 12
Page 13
Prodigy Eclipse 600, 800, 1000 Service Parts
C0600CP, C0800CP and C1410CP Condensers
1
2
4
7
Models ERC680, ERC1086 Item Part Number Number Description
1 03-1405-08 Screw 2 02-3575-01 Fan guard 3 02-3231-03 Filter 4 18-8816-01 Fan blade 5 12-2651-01 Fan motor 6 16-1057-04 Quick connect, disch 16-1057-03 Quick connect, liquid 7 18-8815-01 Coil, ERC680 18-8827-01 Coil, ERC1086 Not Shown: A37169-001 Leg
A37170-001 Leg brace
3
5
6
Model ER2C6810 (two circuit condenser) Item Part Number Number Description
1 03-1405-08 Screw 2 02-3770-01 Fan guard 3 02-3231-03 Filter 4 18-8820-01 Fan blade 5 12-2717-01 Fan motor 6 16-1057-04 Quick connect, discharge 16-1057-03 Quick connect, liquid Not Shown: A37169-001 Leg A37296-001 Leg brace
03-1645-01 Screw for legs
July 2012
Page 13
Page 14
Prodigy Eclipse 600, 800, 1000 Service Parts
L1
EH222 Schematic Diagram
LINE
L2
TRANSFORMER
12V
HOT GAS
VALV E
HGV RELAY
CONTACTOR RELAY
HARVEST ASSIST
SOLENOID
BN
Y
WATER VALVE
TO COMPRESSOR
SECTION
Shown in OFF mode.
WATER LEVEL SENSOR
DISCHARGE TEMP.
DUMP VALV E
ELECTRONIC CONTROL
SUMP TEMP.
ICE THICKNESS PROBE
CURTAIN SWITCH 1
WATER PUMP
July 2012
Page 14
CURTAIN SWITCH 2
Page 15
17-3111-01
Prodigy Eclipse 600, 800, 1000 Service Parts
EH222 Wiring Diagram
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE
WATER
SOLENOID
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL STATE AND LOCAL CODES.
MOT PUMP
BN/W
HOT GAS
SOLENOID
BN/W
HARV ASSIST
W
SOLENOID
USE COPPER CONDUCTORS ONLY
WATER LEVEL SENSOR
ICE THICKNESS PROBE
SUMP TEMP. SENSOR
DISCHARGE TEMP. SENSOR
DUMP VALV E
R
8
4
HGV RELAY
14
12
BN
5
1
13
9
TO COMPRESSOR SECTION
V
V
BN
W
Y
W
BK
Y
8
5
4
1
COMP. RELAY
14
13
12
9
W
TRANSFORMER
GN/Y
V
LOAD
LINE
BK
Y
TERM. BLOCK
L1
W
R
BK
W
BK
ELECTRONIC CONTROL
4321
R/W
W
J10
J6
J7
J8
2
2
1
1
BU
3
2
1
J9
1234
J1
8
J2
1234567
W
W
BN/W
BK
O
Y
SEE NAMEPLATE FOR PROPER VOLTAGE REQUIREMENTS AND MAXIMUM FUSE SIZE
W
N
GN/Y
EARTH ROUND
INLET
POWER
CORD
CAUTION:
CURTAIN SWITCH 1
CURTAIN SWITCH 2
THIS UNIT MUST BE GROUNDED.
Freeze: Coil Freeze: Contacts Harvest: Coil Harvest: Contacts
Comp Relay Energized (by Y) 8-12 closed (to Y) Energized (by Y) 8-12 Closed (to Y)
HGV Relay NOT Energized 5-9 Open Energized (by BN/W) 5-9 Closed (to BN)
July 2012
Page 15
MORE THAN ONE DISCONNECT MEANS MAY BE REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.
Page 16
Prodigy Eclipse 600, 800, 1000 Service Parts
C0600CP, C0800CP and C1410CP Single Phase Schematic Diagram
CONTROL WIRE FROM ICE MAKING SECTION
BN
Y
24 VOLT FROM ICE MAKING SECTION
LOAD 24V TRANSFORMER
HIGH PRESSURE CONTROL
L1
COMPRESSOR SWITCH
CRANKCASE HEATER
LINE TRANSFORMER
CONDENSER BYPASS VALVE ( N.C.)
CONTACTOR COIL
LIQUID INLET VALVE (N.O.)
L2
CONTACTOR T1
POTENTIAL RELAY COIL
COMPRESSOR
ERC CONDENSER FAN (WHEN USED)
POTENTIAL RELAY
July 2012
Page 16
START CAP.
RUN CAP.
Page 17
Prodigy Eclipse 600, 800, 1000 Service Parts
17-3130-01
C0600CP, C0800CP and C1410CP Single Phase Wiring Diagram
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE
USE COPPER CONDUCTORS ONLY
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL STATE AND LOCAL CODES.
Y
Y
COMPRESSOR
1
POWER SUPPLY
1
SEE NAMEPLATE FOR PROPER VOLTAGE REQUIREMENTS AND MAXIMUM FUSE SIZE
SWITCH
BK
L2
W/R
BU
Y/W
BN
POTENTIAL RELAY
1
5
2
RUN CAP
R/W
START CAP
L1
T1
CONTACTOR
BK
T2
GROUND SCREW
TRANSFORMER
V
O
LOAD
LINE
BK
BK
O
BK
CONDENSER BYPASS VALV E
BN
LIQUID IINLET VALV E
BN
BK
CONDENSER FAN LEADS (USED ONLY WITH ERC680 OR ERC1086 CONDENSERS) WIRES SUPPLIED WITH THIS UNIT
EARTH GROUND
O
HIGH PRESSURE CONTROL
THIS UNIT MUST BE GROUNDED.
BK
Y
CRANKCASE HEATER
Y
24 VOLT FROM ICE MAKING SECTION
PROTECTOR INTERNAL
TERMINAL BOX
R
BK
W
COMPRESSOR
C1
S2
R3
R
CAUTION:
MORE THAN ONE DISCONNECT MEANS MAY BE REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.
July 2012
Page 17
Page 18
Prodigy Eclipse 600, 800, 1000 Service Parts
C0600CP, C0800CP and C1410CP Three Phase Schematic Diagram
CONTROL WIRE FROM
24 VOLT FROM ICE MAKING SECTION
LOAD 24V TRANSFORMER
ICE MAKING SECTION
HIGH PRESSURE CONTROL
L1
COMPRESSOR SWITCH
CRANKCASE HEATER
LINE TRANSFORMER
CONTACTOR COIL
CONDENSER BYPASS VALVE ( N.C.)
LIQUID INLET VALVE (N.O.)
L2
L3
CONTACTOR T1
COMPRESSOR
ERC CONDENSER FAN (WHEN USED)
July 2012
Page 18
T2
T3
Page 19
Prodigy Eclipse 600, 800, 1000 Service Parts
17-3131-01
C0600CP, C0800CP and C1410CP Three Phase Wiring Diagram
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE
USE COPPER CONDUCTORS ONLY
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL STATE AND LOCAL CODES.
Y
Y
COMPRESSOR SWITCH
GROUND SCREW
BK
BK
BK
L1
L3L2
BK
1
1
1
EARTH GROUND
BK
CONDENSER FAN LEADS (USED ONLY WITH
BK
WIRES SUPPLIED WITH CONDENSING UNIT)
POWER SUPPLY SEE NAMEPLATE FOR PROPER VOLTAGE REQUIREMENTS AND MAXIMUM FUSE SIZE
T3T2T1
CONDENSER BYPASS
BN
BN
VALV E
LIQUID IINLET VALV E
O
CONTACTOR
V
O
LOAD
LINE
TRANSFORMER
O
HIGH PRESSURE CONTROL
THIS UNIT MUST BE GROUNDED.
R
R
CRANKCASE HEATER
Y
24 VOLT FROM ICE MAKING SECTION
PROTECTOR INTERNAL
TERMINAL BOX
R
BK
W
COMPRESSOR
C1
S2
R3
R
CAUTION:
MORE THAN ONE DISCONNECT MEANS MAY BE REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.
July 2012
Page 19
Page 20
Prodigy Eclipse 600, 800, 1000 Service Parts
50 Hz Model Wiring and Schematic Diagram
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE
USE COPPER CONDUCTORS ONLY
L2
ASSIST
HARVEST
SOLENOID
HGV
VALVE
RELAY
HOT GAS
12V
LINE
SECTION
TO COMPRESSOR
WATER VALVE
SWITCH 1
CURTAIN
WATER
ICE
PROBE
THICKNESS
PUMP
CONTACTOR
RELAY
TEMP.
SUMP
ELECTRONIC CONTROL
TEMP.
DISCHARGE
DUMP
CAUTION:
VALVE
MORE THAN ONE DISCONNECT MEANS MAY BE
REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.
FUSE
CODE AND ALL STATE AND LOCAL CODES.
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTR ICAL
SEE NAMEPLATE FOR PROPER
VOLTAGE REQUIREMENTS
TRANSFORMER
AND MAXIMUM FUSE SIZE
CORD POWER INLET
L1
BU
5 8
SOLENOID
HARV ASSIST
TO COMPRESSOR
SECTION
W
V
V
5 8
(3A)
N
BN
TERM.
BLOCK
L1
Y
BN
9
13
COMP.
RELAY
W
14
12
W
9
13
HGV
14
12
RELAY
1
4
1 4
GN/Y
VV
BK
Y
FUSE (3A)
WATER
LEVEL
SENSOR
EARTH
ROUND
12V
LOAD
LINE
230V
1
10
9
2
GN/Y
BK
4
7
TRANSFORMER
5
6
BK
W
BN/W
W
BK
O
Y
THIS UNIT MUST
BE GROUNDED.
HOT GAS
SOLENOID
BN/W
BN/W
17-3396-01
MOT
PUMP
WATER
SOLENOID
W
W
DUMP
VALVE
R/W
BU
3
4321
2
J9
1
J1
J10
W
W
7654321
8
J2
2 1
J8
2 1
J7
J6
CONTROL
ELECTRONIC
1 2 3 4
SWITCH 1
CURTAIN
BK
BK
R
R
LEVEL
SENSOR
WATER
ICE
PROBE
THICKNESS
SENSOR
SUMP TEMP.
SENSOR
DISCHARGE
TEMP.
July 2012
Page 20