Scotsman C0322, C0522, C0330, C0530, C0630 Operation Manual

...
Installation and User's Manual for Modular Cuber
Models C0322, C0522, C0330, C0530, C0630, C0830 and C1030
Introduction
C0322 through C1030
Air and Water Cooled User Manual
The design of this modular cuber is the result of years of experience and testing. Standard features include front accessible indicator lights and on-off switches that provide the user with fast access to critical information and easy operational control. .
Keep this manual for future reference.
This installation and user manual is divided into three main sections: Installation, which provides the trade person with the information needed to set up and install this product; Use and Operation, which provides the user with the information to use the product; and Maintenance, which provides the user with the information needed keep it operating efficiently.
Table of Contents
Installation: Product Specifications ............................... Page 2
Model Number Description ................................... Page 3
Product Description & Electrical Requirements ......................... Page 4
C0322 and C0522 Cabinet Layout ............................... Page 5
C0330, C0530, C0630, C0830 and C1030 Cabinet Layout ................... Page 6
Water .............................................. Page 7
Panel Removal ......................................... Page 8
Plumbing Requirements ..................................... Page 9
Electrical ............................................. Page 10
Final Check List ......................................... Page 11
Initial Start Up .......................................... Page 12
Adjustments ........................................... Page 13
Use and Operation........................................ Page 14
Control Switches......................................... Page 15
Options ............................................. Page 16
Cleaning, Sanitation and Maintenance ............................. Page 17
Air cooled condenser filter .................................... Page 19
What to do before calling for service .............................. Page 20
Note any Caution or Warning symbols when they appear on the product or in this manual. They indicate potential hazards.
July 2006
Page 1
C0322 through C1030 Air and Water Cooled User Manual
Installation: Product Specifications
Location Limitations:
The product is designed to be installed indoors, in a controlled environment. Air cooled models discharge very warm air into the room out the back. Space must be allowed at the left side and back for air intake and discharge. Water cooled models discharge warm water into the building’s drain. Space needs to be provided on both sides and above for service access.
Space Limitations
Note: Although the machine will function, ice capacity of air cooled machines will be significantly reduced with minimal clearance at the sides, back and top. Some space is recommended for service and maintenance purposes on all models.
6" of space at the sides and back are required for adequate operation. To get the most capacity, locate the machine away from heat producing appliances and heating ducts, and keep the left side away from any wall, allow 12-18 inches of space for good air flow
Airflow is in the left side, out the back (as viewed from the front).
Environmental Limitations
Minimum Maximum
Air temperature
Water temperature
Water pressure
o
50
F. 100oF.
o
40
F. 100oF.
20 psi 80 psi
Power supply – acceptable voltage ranges
Minimum Maximum
115 volt model 104 volts 126 volts
230 volt model 198 volts 253 volts
Warranty Information
The warranty statement for this product is provided separately from this manual. Refer to it for applicable coverage. In general warranty covers defects in material or workmanship. It does not cover maintenance, corrections to installations, or situations when the machine is operated in circumstances that exceed the limitations printed above.
Air Flow
Product Information
The product is a modular cuber. That type of machine is designed to be placed on an ice storage bin or an ice dispenser. Many installations only require the matching bin, but some also require an adapter to be placed between the bin and the cuber or between the dispenser and the cuber. This product cannot be stacked. See the chart for application information.
May 2007
Page 2
Model Number Description
C0322 through C1030
Air and Water Cooled User Manual
Example:
C0322SA-1A
C= cuber
03= nominal ice capacity in 100s of pounds
22= nominal width of cabinet
S= Cube size. S=small or half dice cube.
M=medium or full dice cube A=Condenser type. A=air cooled. W=water
cooled
-1=115 60 Hz, -32=208-230 60 Hz
A=Series revision code. A=first series
Note: Model numbers in the manual might include only the first five characters of the model number.
Options:
There are several field-installed options that can be installed at initial start up or later. They include:
KVS, Vari-Smart Adjustable ice level system.
KSB, SmartBoard Advanced feature board.
KPMFA223, front air flow panel. Fits C0322
and C0522.
KPMFA303, front air flow panel. Fits C0330, C0530, C0630.
KPFMA309, front air flow panel. Fits C0830 and C1030.
A39514-021 anti-recirculation baffle. Fits C0322, C0330, C0522, C0530, C0630.
A39515-021, anti-recirculation baffle. Fits C0830 and C1030.
Some installations require bin or dispenser adapters. See the table. Standard Bin
Applications - Adapter information.
Hotel Dispensers
The HD22 and HD30 are compatible with this ice machine, no adapters are needed.
HD22 – use with C0322 or C0522
HD30 – use with C0330 or C0530
Note: All models ship with the On and Off switches front accessible. If desired, the On and Off switches can be covered but by changing the bezel in the front panel’s trim strip. A cover-up bezel ships loose with the machine.
Ice and Beverage Dispensers – Adapter information
Model ID150 ID200 or ID250
C0322, C0522 KBT42 KBT43
C0530, C0630, C0830, C1030
Does not fit
KBT44
Other Bins & Applications:
Note the drop zone and ultrasonic sensor locations in the illustrations on the next pages.
Scotsman ice systems are designed and manufactured with the highest regard for safety and performance.
Scotsman assumes no liability of responsibility of any kind for products manufactured by Scotsman that have been altered in any way, including the use of any part and/or other components not specifically approved by Scotsman.
Model
C0322, C0522
C0530, C0630, C0830, C1030
B530P,
BH360, or B222 or B322
Direct fit KBT27
Does not fit
B330P, B530S, HTB555 or BH550
Direct fit KBT28 KBT22
BH800, BH801, B842S
Not available
BH900, B948S
Not available
August 2006
Page 3
Scotsman reserves the right to make design changes and/or improvements at any time. Specifications and design are subject to change without notice.
C0322 through C1030 Air and Water Cooled User Manual
Product Description & Electrical Requirements
Dimensions w"xd"xh"
22.75** x 24 x 23
30.75** x 24 x 23
Model
C0322SA-1 115/60/1 Air 12.7 15
C0322SW-1 115/60/1 Water 11.9 15
C0322SA-32 208-230/60/1 Air 6.1 15
C0322SW-32 208-320/60/1 Water 5.6 15
C0522SA-1 115/60/1 Air 13.8 15
C0522SW-1 115/60/1 Water 12.2 15
C0522SA-32 208-230/60/1 Air 7.6 15
C0522SW-32 208-230/60/1 Water 6.7 15
C0330SA-1 115/60/1 Air 12.7 15
C0330SW-1 115/60/1 Water 11.9 15
C0330SA-32 208-230/60/1 Air 6.1 15
C0330SW-32 208-230/60/1 Water 5.6 15
C0530SA-1 115/60/1 Air 13.9 15
C0530SW-1 115/60/1 Water 12.2 15
Electrical volts/Hz/phase
Condenser
Minimum Circuit Ampacity
Maximum Fuse Size*
C0530SA-32 208-230/60/1 Air 7.9 15
C0530SW-32 208-230/60/1 Water 6.7 15
C0630SA-32 208-230/60/1 Air 18.2 20
C0630SW-32 208-230/60/1 Water 17 20
C0830SA-32 208-230/60/1 Air 10.2 15
C0830SW-32 208-230/60/1 Water 9 15
C0830SA-3 208-230/60/3 Air 8.4 15
30.75** x 24 x 29
Table notes: Medium cube models have the same electrical characteristics as Small. Series revision code omitted.
* Or HACR type circuit breakers. ** Maximum width at top panel. Air cooled models add .75" for left side louvers.
C0830SW-3 208-230/60/3 Water 7.2 15
C1030SA-32 208-230/60/1 Air 16 20
C1030SW-32 208-230/60/1 Water 14.8 15
C1030SA-3 208-230/60/3 Air 11 15
C1030SW-3 208-230/60/1 Water 9.8 15
July 2006
Page 4
C0322 and C0522 Cabinet Layout
PLAN VIEW
22" PRODIGY
24.00 REF.
61
22.00 REF.
55.9
2.00
5.1
2.00
5.1
19.05
48.4
3.25
8.3
10.25
26
7.00
17.8
ICE DROP OPENING
ULTRASONIC BIN LEVEL SENSOR (OPTIONAL)
LEFT SIDE VIEW
24.00
61
LOUVER AND REMOVABLE FILTER AC UNITS ONLY
AIR COOLED
BACK VIEW
1.43
3.6
1.62
4.1
3.04
7.7
10.79
27.4
14.56
37
1.60
4.1
3/8" FPT WATER INLET
3/4" FPT DRAIN
.88" DIA ELECTRICAL ACCESS
C0322 through C1030
Air and Water Cooled User Manual
Note: Top number is centimeters, bottom number is inches.
C0322, C0522 Air Cooled Side View
Top View
July 2006
Page 5
C0322, C0522 Air Cooled Back View
AIR COOLED
BACK VIEW
3.06
7.8
10.81
27.5
14.59
37
1.48
3.7
1.73
4.4
1.70
4.3
3/4" FPT DRAIN
3/8" FPT WATER INLET
.88" DIA ELECTRICAL ACCESS
LEFT SIDE VIEW
24.00
61
LOUVER AND REMOVABLE FILTER AC UNITS ONLY
C0322 through C1030
PLAN VIEW
24.00 REF.
61
30.00 REF.
76.2
2.00
5.1
2.00
5.1
19.05
48.4
3.25
8.3
10.25
26
7.00
17.8
ICE DROP OPENING
ULTRASONIC BIN LEVEL SENSOR (OPTIONAL)
LEFT SIDE VIEW
24.00
61
LOUVER AND REMOVABLE FILTER AC UNITS ONLY
Air and Water Cooled User Manual
C0330, C0530, C0630, C0830 and C1030 Cabinet Layout
C0330, C0530, C0630 AC Back View
Top View - All
Note: Top number is centimeters, bottom number is inches.
July 2006
C0330, C0530, C0630 Air Cooled Side View
C0830, C1030 Air Cooled Side View
Page 6