The design of this modular cuber is the result of
years of experience and testing. Standard features
include front accessible indicator lights and on-off
switches that provide the user with fast access to
critical information and easy operational control. .
Keep this manual for future reference.
This installation and user manual is divided into
three main sections: Installation, which provides
the trade person with the information needed to set
up and install this product; Use and Operation,
which provides the user with the information to use
the product; and Maintenance, which provides the
user with the information needed keep it operating
efficiently.
Cleaning, Sanitation and Maintenance ............................. Page 17
Air cooled condenser filter .................................... Page 19
What to do before calling for service .............................. Page 20
Note any Caution or Warning symbols when they
appear on the product or in this manual. They
indicate potential hazards.
July 2006
Page 1
C0322 through C1030
Air and Water Cooled User Manual
Installation: Product Specifications
Location Limitations:
The product is designed to be installed indoors, in
a controlled environment. Air cooled models
discharge very warm air into the room out the back.
Space must be allowed at the left side and back for
air intake and discharge. Water cooled models
discharge warm water into the building’s drain.
Space needs to be provided on both sides and
above for service access.
Space Limitations
Note: Although the machine will function, ice
capacity of air cooled machines will be significantly
reduced with minimal clearance at the sides, back
and top. Some space is recommended for service
and maintenance purposes on all models.
6" of space at the sides and back are required for
adequate operation. To get the most capacity,
locate the machine away from heat producing
appliances and heating ducts, and keep the left
side away from any wall, allow 12-18 inches of
space for good air flow
Airflow is in the left side, out the back (as viewed
from the front).
Environmental Limitations
MinimumMaximum
Air
temperature
Water
temperature
Water
pressure
o
50
F.100oF.
o
40
F.100oF.
20 psi80 psi
Power supply – acceptable voltage ranges
MinimumMaximum
115 volt model104 volts126 volts
230 volt model198 volts253 volts
Warranty Information
The warranty statement for this product is provided
separately from this manual. Refer to it for
applicable coverage. In general warranty covers
defects in material or workmanship. It does not
cover maintenance, corrections to installations, or
situations when the machine is operated in
circumstances that exceed the limitations printed
above.
Air Flow
Product Information
The product is a modular cuber. That type of
machine is designed to be placed on an ice
storage bin or an ice dispenser. Many installations
only require the matching bin, but some also
require an adapter to be placed between the bin
and the cuber or between the dispenser and the
cuber. This product cannot be stacked. See the
chart for application information.
May 2007
Page 2
Model Number Description
C0322 through C1030
Air and Water Cooled User Manual
Example:
C0322SA-1A
•
C= cuber
•
03= nominal ice capacity in 100s of pounds
•
22= nominal width of cabinet
•
S= Cube size. S=small or half dice cube.
•
M=medium or full dice cube
A=Condenser type. A=air cooled. W=water
•
cooled
-1=115 60 Hz, -32=208-230 60 Hz
•
A=Series revision code. A=first series
•
Note: Model numbers in the manual might include
only the first five characters of the model number.
Options:
There are several field-installed options that can be
installed at initial start up or later. They include:
KVS, Vari-Smart Adjustable ice level system.
•
KSB, SmartBoard Advanced feature board.
•
KPMFA223, front air flow panel. Fits C0322
•
and C0522.
•
KPMFA303, front air flow panel. Fits C0330,
C0530, C0630.
•
KPFMA309, front air flow panel. Fits C0830
and C1030.
A39515-021, anti-recirculation baffle. Fits
C0830 and C1030.
Some installations require bin or dispenser
adapters. See the table. Standard Bin
Applications - Adapter information.
Hotel Dispensers
The HD22 and HD30 are compatible with this ice
machine, no adapters are needed.
HD22 – use with C0322 or C0522
•
HD30 – use with C0330 or C0530
•
Note: All models ship with the On and Off switches
front accessible. If desired, the On and Off
switches can be covered but by changing the bezel
in the front panel’s trim strip. A cover-up bezel
ships loose with the machine.
Ice and Beverage Dispensers – Adapter
information
ModelID150ID200 or ID250
C0322, C0522KBT42KBT43
C0530, C0630,
C0830, C1030
Does not
fit
KBT44
Other Bins & Applications:
Note the drop zone and ultrasonic sensor locations
in the illustrations on the next pages.
Scotsman ice systems are designed and
manufactured with the highest regard for safety
and performance.
Scotsman assumes no liability of responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any part and/or other components not
specifically approved by Scotsman.
Model
C0322,
C0522
C0530,
C0630,
C0830,
C1030
B530P,
BH360,
or B222
or B322
Direct fitKBT27
Does not
fit
B330P,
B530S,
HTB555
or
BH550
Direct fitKBT28KBT22
BH800,
BH801,
B842S
Not
available
BH900,
B948S
Not
available
August 2006
Page 3
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and design are subject to change
without notice.
C0322 through C1030
Air and Water Cooled User Manual
Product Description & Electrical Requirements
Dimensions
w"xd"xh"
22.75** x 24 x 23
30.75** x 24 x 23
Model
C0322SA-1115/60/1Air12.715
C0322SW-1115/60/1Water11.915
C0322SA-32208-230/60/1Air6.115
C0322SW-32208-320/60/1Water5.615
C0522SA-1115/60/1Air13.815
C0522SW-1115/60/1Water12.215
C0522SA-32208-230/60/1Air7.615
C0522SW-32208-230/60/1Water6.715
C0330SA-1115/60/1Air12.715
C0330SW-1115/60/1Water11.915
C0330SA-32208-230/60/1Air6.115
C0330SW-32208-230/60/1Water5.615
C0530SA-1115/60/1Air13.915
C0530SW-1115/60/1Water12.215
Electrical
volts/Hz/phase
Condenser
Minimum
Circuit
Ampacity
Maximum
Fuse Size*
C0530SA-32208-230/60/1Air7.915
C0530SW-32208-230/60/1Water6.715
C0630SA-32208-230/60/1Air18.220
C0630SW-32208-230/60/1Water1720
C0830SA-32208-230/60/1Air10.215
C0830SW-32208-230/60/1Water915
C0830SA-3208-230/60/3Air8.415
30.75** x 24 x 29
Table notes: Medium cube models have the same electrical characteristics as Small. Series revision
code omitted.
* Or HACR type circuit breakers.
** Maximum width at top panel. Air cooled models add .75" for left side louvers.
C0830SW-3208-230/60/3Water7.215
C1030SA-32208-230/60/1Air1620
C1030SW-32208-230/60/1Water14.815
C1030SA-3208-230/60/3Air1115
C1030SW-3208-230/60/1Water9.815
July 2006
Page 4
C0322 and C0522 Cabinet Layout
PLAN VIEW
22" PRODIGY
24.00 REF.
61
22.00 REF.
55.9
2.00
5.1
2.00
5.1
19.05
48.4
3.25
8.3
10.25
26
7.00
17.8
ICE DROP OPENING
ULTRASONIC
BIN LEVEL
SENSOR
(OPTIONAL)
LEFT SIDE VIEW
24.00
61
LOUVER AND
REMOVABLE FILTER
AC UNITS ONLY
AIR COOLED
BACK VIEW
1.43
3.6
1.62
4.1
3.04
7.7
10.79
27.4
14.56
37
1.60
4.1
3/8" FPT
WATER
INLET
3/4" FPT
DRAIN
.88" DIA
ELECTRICAL
ACCESS
C0322 through C1030
Air and Water Cooled User Manual
Note: Top number is centimeters, bottom number is inches.
C0322, C0522 Air Cooled Side View
Top View
July 2006
Page 5
C0322, C0522 Air Cooled Back View
AIR COOLED
BACK VIEW
3.06
7.8
10.81
27.5
14.59
37
1.48
3.7
1.73
4.4
1.70
4.3
3/4" FPT
DRAIN
3/8" FPT
WATER
INLET
.88" DIA
ELECTRICAL
ACCESS
LEFT SIDE VIEW
24.00
61
LOUVER AND
REMOVABLE FILTER
AC UNITS ONLY
C0322 through C1030
PLAN VIEW
24.00 REF.
61
30.00 REF.
76.2
2.00
5.1
2.00
5.1
19.05
48.4
3.25
8.3
10.25
26
7.00
17.8
ICE DROP OPENING
ULTRASONIC
BIN LEVEL
SENSOR
(OPTIONAL)
LEFT SIDE VIEW
24.00
61
LOUVER AND
REMOVABLE FILTER
AC UNITS ONLY
Air and Water Cooled User Manual
C0330, C0530, C0630, C0830 and C1030 Cabinet Layout
C0330, C0530, C0630 AC Back View
Top View - All
Note: Top number is centimeters, bottom number is inches.
July 2006
C0330, C0530, C0630 Air Cooled Side View
C0830, C1030 Air Cooled Side View
Page 6
Loading...
+ 15 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.