SCI Scandicrafts A2840R User Manual

Fresh Air, Surface and Fabric Regenerator
Air-Surface Sanitizer
OWNER’S MANUAL
MORE THAN JUST AIR PURIFIERS... THEY HELP TO SANITIZE BOTH THE AIR AND SURFACES
INCLUDES:
• INSTALLATION
• OPERATION
• SPECIFICATIONS
• FEATURES
• MAINTENANCE
• 10 PURIFICATION STEPS T HEALTHY HOME
O
A
IMPORTANT:
VE THIS BOOKLET!
SA
A2840/R
CONTENTS
EdenPURE™ G-7 (WHOLE HOUSE MODEL)
SPECIFICATIONS.......................................................................................1
SAFETY WARNINGS..................................................................................2
FEATURES..................................................................................................3
INSPECTION & INSTALLATION.................................................................3
GENERAL OPERATION..............................................................................4
GENERAL MAINTENANCE.........................................................................5
MAINTENANCE DIAGRAMS.......................................................................6
CHANGING THE UV LAMP.........................................................................7
CHANGING THE FUSE...............................................................................8
TROUBLESHOOTING.................................................................................9
WARRANTY................................................................................................18
EdenPURE™ AREA MODEL
SPECIFICATIONS.......................................................................................1
SAFETY WARNINGS..................................................................................10
FEATURES..................................................................................................11
INSPECTION & INSTALLATION.................................................................11
ADVANCED FUNCTIONS...........................................................................12
GENERAL OPERATION..............................................................................13
FUNCTION OVERVIEW..............................................................................13
GENERAL MAINTENANCE.........................................................................14
WARRANTY................................................................................................18
10 PURIFICATION STEPS TO A HEALTHY HOME..................................15-17
Parts and Supplies: Contact the dealer you purchased your product from or visit
www.rppurchase.com to locate your closest dealer.
SPECIFICATIONS
EdenPURE™ G-7
Power Fuse Total Watts Anion Ion Generator Fan Dimensions Weight Activated Oxygen Output Coverage
110v AC, 60Hz
1.6 amp slow blow fuse 5 - 70 Yes 5 Speeds 12 3/4” (H) x 8 7/8” (W) x 8 3/4” (D) 16 pounds Up to 360 mg per hour Up to 3000 sq. ft.
EdenPURE™ Area Model
Power Total Watts Anion Ion Generator Fan Dimensions Weight Activated Oxygen Output Coverage
120v AC, 60Hz 30 - 45 Yes 3 Speeds 11 5/8” (H) x 12 5/8” (W) x 6 3/8” (D) 11 pounds Up to 50 mg per hour Up to 1000 sq. ft.
1
EdenPURE™ G-7
READ AND SAVE THESE INSTRUCTIONS
VERY IMPORTANT:
• Read this manual carefully before operating.
• Do not operate unit if unfamiliar with this manual.
• Keep this manual for future reference.
SAFETY WARNINGS
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY, BASIC PRECAUTIONS SHOULD BE FOLLOWED INCLUDING:
• Disconnect power cord before performing any maintenance or service.
• The rear of the unit should always have at least one inch of open area to allow unrestricted airflow.
• To prevent injury, be sure the power cord is not accessible to small children.
• The supplied power voltage must be uniform with the appliance’s permitted voltage
indicated on the back of the unit. Appliances with 110v/60Hz cannot be used with a 220v/50 Hz power supply.
• Only connect to a properly grounded 3 prong circuit receptacle.
• Do not alter the cord or any other part of the unit.
• Do not use with a broken ceramic plate.
• Do not look directly at the UVC bulb while it is operating.
• Do not use outdoors or on wet surfaces.
• Do not use with a damaged cord or plug.
• Do not unplug by pulling on the cord. To unplug, grasp the plug, not the cord.
• Do not operate the unit in areas where flammable, combustible products, or where
vapors may be present.
• Do not handle the plug or appliance with wet hands.
• Supervision is necessary when appliance is operated near children.
• Turn off all controls before unplugging unit from outlet.
• If appliance is not working as it should, has been dropped, damaged, left outdoors, or
dropped into water, contact the sales representative where you purchased the unit or return it to your local service center.
2
FEATURES
· QUIET FIVE SPEED FAN
· ADJUSTABLE 24-HOUR CLOCK
· ADJUSTABLE POWER OFF TIMER
· ADJUSTABLE PURIFIER CONTROL (USED FOR RAPID ODOR REMOVAL AND
SURFACE STERILIZATION)
· ANION - NEGATIVE ION GENERATOR (NEGATIVE IONS CAUSE THE FLOATING
PARTICULATES TO CLING TOGETHER, FORMING A MASS WHICH DROPS THEM TO THE FLOOR TO BE SWEPT UP)
· STERILIZE (UVC LIGHT HELPS REDUCE AIRBORNE GERMS AS THEY PASS
THROUGH THE UNIT)
· HELPS REDUCE SMOKE AND ODORS FROM YOUR HOME, OFFICE, CAR, BOAT,
RV, ETC...
· REDUCES MOLD, MILDEW AND BACTERIA
· REPLACEABLE UV LAMP
· REMOTE CONTROL OR MANUAL OPERATION VIA FRONT PANEL CONTROLS
· USER INTERFACE DISPLAY
· MAINTENANCE REMINDERS
· WASHABLE PURIFICATION PLATE
· WASHABLE PHOTO-CATALYTIC PROCESS SCREEN
· WASHABLE PRIMARY FILTER
· SLEEP MODE (DISABLES MOST OF THE DISPLAY LIGHTS, BUT UNIT CONTINUES
TO OPERATE)
· IMPROVES INDOOR AIR QUALITY
· USES STANDARD HOUSEHOLD CURRENT
INSPECTION & INSTALLATION
1. Remove unit from shipping carton.
2. Check for shipping damage and loose or broken parts.
3. Remove any protective materials from the outside of the unit.
4. Read Owner’s Manual thoroughly prior to operating or servicing the unit.
5. Insert the battery into the remote by sliding the battery compartment open and placing the battery with the positive side (+) facing up.
6. Open the Primary Filter by removing the four corner screws and remove all protective materials from the inside of the unit, i.e. tape used to hold the Catalytic Screen and/or UV Lamp in place.
7. Make sure Catalytic Screen is secure. (Refer to: “GENERAL MAINTENANCE”, page 5)
8. Make sure the purification plate is secure and fully inserted in its slot. (Refer to: Page 6 Diagram B)
9. Reinstall the Primary Filter and any other temporarily removed parts before continuing.
10. Determine placement location for the unit. possible. A securely fastened wall shelf would be an ideal location.
11. Plug the unit into a 3 prong grounded circuit receptacle.
We recommend placing it up higher if
3
GENERAL OPERATION
The unit can be operated using either the wireless remote or the front control panel.
1. On the rear of the purifier, switch the master power to the “on” position (the front display
will light up).
2. Press the
3. Press the Fanand Fanbuttons to adjust the airflow speed to your desired level.
4. Press the Purifyand Purifybuttons to set the purifier setting from Stage 1 through
Stage 5 to accommodate your desired level.
5. Press the Sterilize button to operate the UVC and Photo Catalyst sanitize feature.
Press the Sterilize button again to stop its operation. The UVC bulb will produce a light blue glow on the inside of the unit when this feature is on. Note: Do not look
directly at the UVC Bulb while it is operating.
6. Press the Anion button to turn on the negative ion generator. Press the Anion button
again to stop the negative ion generator function.
Sleep Button
Press the Sleep button to use the screen saving mode. This will turn most of the display lights off. Press any button on the front panel to deactivate the sleep mode. The working mode of Anion, Purify, Sterilize, and Fan Speed will not change while in sleep mode. If the timer function is set to turn the power off at a set time, do not use the sleep function. The timer will only deactivate the sleep mode instead of shutting down the unit if the sleep mode is on.
Time/Set Button
*** After 8-10 seconds of inactivity, the clock will be set or you will have to start the process again. ***
To set the current time:
1. Press the Time/Set button twice. “Time” will blink on the display.
2. The Purifyand Purifybuttons adjust the hours. The Fanand Fanbuttons adjust the minutes.
To set the power off timer:
1. While the unit is operating, press the Time/Set button once. “Time/Set” will blink on the display.
2. The Purifyand Purifybuttons adjust the hours. The Fanand Fanbuttons
adjust the minutes.
ON/OFF button on the front of purifier to power on the unit. The fan will start.
Read these instructions thoroughly before setting the time.
The clock is a 24-hour clock; 13:00 would be 1:00 p.m.
OFF
O
N
Sterilizer Feature Purifier Feature (5 Stages) Anion Feature
Power Switch Time Fan Speed Operating Display Operating Buttons
4
Remote
GENERAL MAINTENANCE
UNPLUG THE UNIT BEFORE PERFORMING ANY MAINTENANCE PROCEDURES
Recommended Monthly Maintenance
• Clean the Primary Filter
• Clean the Purifier Plate
• Clean the Catalytic Screen
PRIMARY FILTER & CATALYTIC SCREEN CLEANING
You have three options to clean the Primary filter and the Catalytic Screen:
1. When visibly dirty or after 30 days, remove the primary filter and the catalytic screen
from the unit. With a hand-held vacuum, remove the heavy particulates from both filters. This method will extend the life of the filters and ensure proper function of the catalytic screen.
2. If vacuuming does not clean the filter sufficiently, remove the primary filter and the
catalytic screen from the unit and wash them in warm water. Brush gently with a toothbrush to remove particulates. Allow to dry thoroughly before re-installing.
NOTE: Do not use soap because it could damage the filters.
3. If a replacement or additional filter and/or catalytic screen are needed, contact the
dealer you purchased your product from or visit www.rppurchase.com to locate your closest dealer.
CLEANING THE PURIFICATION PLATE
1. Remove the Purification Plate (see Purification Plate and Catalytic Screen Removal below).
2. Wash the Purification Plate with about 1 drop of mild dish soap (per side) and a toothbrush.
3. Use the toothbrush to make small circular motions over all of the metal mesh areas.
Be careful not to drop or break the Purification Plate while cleaning.
4. Rinse with water and allow it to air dry completely before reinstalling.
PRIMARY FILTER REMOVAL
1. Unplug the power to the unit.
2. Unscrew the four rear corner screws from the Primary filter and pull the filter handle
to remove. Refer to Diagram A
3. After servicing Primary filter, place it back in its original position and re-install the
four corner screws.
PURIFICATION PLATE AND CATALYTIC SCREEN REMOVAL
1. Remove Primary filter.
2. Carefully remove the Purification Plate pulling it straight out. This is an ideal time to
clean the Purification Plate. Refer to Diagram B.
Gently pull the Catalytic Screen handle to remove it for cleaning.
3.
4. After servicing Catalytic Screen, place it back in its original position by placing the
bottom of screen in first.
5. Carefully re-insert the Purification Plate into its original position. Make sure the
Purification Plate is fully inserted.
6. Place the Primary filter back in its original position and re-install the four corner screws.