Welcome to the “Rotator User Manual”. Users should read
this manual carefully, follow the instructions and
procedures, and beware of all the cautions when using this
instrument.
Service
Please provide the customer care representative with the
following information:
•Serial number ( on the rear panel )
•Certification
•Description of problem ( i.e., hardware or software )
•Methods and procedures adopted to resolve the
problems
•Your contact information
When help needed, you can always contact the service
department of manufacturer for technical support in the
following ways:
SCILOGEX, LLC
500 Four Rod Road
Suite 122
Berlin, CT 06037 USA
Tel: 1-860-828-5289
Fax: 1-860-828-5389
E-mail: info@scilogex.com
Http://www.scilogex.com
Warranty
This instrument is warranted to be free from defects in
materials and workmanship under normal use and service,
for a period of 24 months from the date of invoice. The
warranty is extended only to the original purchaser. It shall
not apply to any product or parts which have been damaged
on account of improper installation, improper connections,
misuse, accident or abnormal conditions of operation.
For claims under the warranty please contact your local
supplier. You may also send the instrument directly to
manufacturer, enclosing the invoice copy and by giving
reasons for the claim.
1
Rotator
1. Safety Instructions
Warning!
•Read the operating instructions carefully
before use.
•Ensure that only trained staff works with the
instrument.
Protective ground contact!
•Ensure the socket must be grounded
(protective ground contact) before use.
•When working wear personal safety guards to avoid
the risk of:
‐ Splashing liquids
‐ Broken glass containers
•Follow the safety instructions, guidelines and accident
prevention regulations.
•Do not touch the running parts, moving instrument
care not rolling your fingers.
•Set up the instrument in a spacious area on a stable,
clean, non-slip, dry and fireproof surface. Do not
operate the instrument in explosive atmospheres, with
hazardous substances or under water.
•If the instrument does not run smoothly, please
decrease the motor speed.
•Firmly secure the accessories and vessels in place to
avoid damage or risk.
•Preparation of samples may lead to dangerous
flammable. Only process samples that will not react
dangerous.
•Use the standard accessories listed in the “accessories”
section, and follow the instructions to use accessories
to ensure safety. Please switch off the power before
assembly of accessories, confirm the instrument and
accessories are intact before switch on each time.
•The instrument only be opened by expert, please
switch off before use.
•The voltage stated on the nameplate must correspond
to the mains voltage.
•Do not cover the instrument during running. Prevent
the collision and extrusion to instrument and
accessories.
•Keep away from high magnetic field.
2
Rotator
2. Proper Use
The instrument is designed for mixing sticky substance in
schools, laboratories or factories. It can be installed on a
variety of impeller, for different viscosity of the medium.
This instrument is not suitable for using in residential areas
or other constraints mentioned in Chapter 1.
Do not use the accessories recommended by the
manufacturer, or failure to use the instructions, may be
caused unsafe situation.
3. Inspection
3.1 Receiving Inspection
Unpack the instrument carefully and check for any damages
which may have arisen during transport. If it happens,
please contact manufacturer/supplier for technical support.
Note:
If there is any apparent damage to the system,
please do not connect to the power line.
3.2 Listing of Items
Items
Main unit 1
Power cable 1
User manual 1
T able 1
Qty
3
4. Function
4.1 Control
Rotator
Power switch
Angle control knob
Figure 1
Figure 2
Figure 3
4
Rotator
ItemsDefault settings
Mode switch button
Mode
Speed /timer control
knob
Speed/timer light
Speed/Timer
Power/Overload
protection light
Power/Overload
Shift speed and time display.
Set speed and time by rotating
speed/timer control knob. Push
on/off to start/stop rotating function.
Green/Red LED display light.
Different colors of LED light show
the value for speed or time that LCD
screen currently displays. Green
LED light shows that LCD screen
currently displays speed. Red LED
light shows that LCD screen
currently displays time.
Green/Red LED display light.
LED light shows green when switch
on, LED light shows red when starts
overload protection. When the
torque reaches limited value,
overload protection function will be
started. At the same time overload
protection light flashes, while the
system stops running.
LCD display
Power switch I/O
LCD displays the real working state
and all setting values.
Switch ON or OFF the instrument.
Table 2
4.2 Display
Figure 4
DisplayDescriptions
Set Display when set target value.
ErrDisplay in case of error happening.
Display area When Set displays, this area shows
setting value; When Set disappears, this
area shows running value.
Table 3
5
Rotator
5. Operation
•Place the Rotator in safe and stable surface, ensure the
required operating voltage and power supply voltage
matched, and the socket must be earthed reliably.
•Connect the power cable.
•Switch ON instrument.
•The instrument begins self-checking.
•When initialization is over, LCD displays the last
running values of speed.
•Rotate the speed/timer control knob to set targe t spee d.
a.Press the speed/timer control knob to start
rotating function. Press the knob again to stop rotating
function.
b.Press the mode switch button, LCD displays time,
and then rotating the speed/timer control knob to set
target time. Press the speed/timer control knob to start
rotating function at the set time. During operation,
motion can be stopped at any time by pressing the
speed/timer control knob. If the knob is pressed again,
motion will start again and the timer willrestart
countdown. When the timer reaches zero, the unit will
be automatically halted and an alert will sound.
If these operations above are normal, the instrument is
ready to operate. If not, the instrument may be damaged
during transportation, please contact technical support of
manufacturer/supplier.
Note:
The set values can be altered at any time.
6. Faults
•Instrument cannot be powered ON when start rotating
function.
Check whether the power cable is connected.
•Rotating function suddenly stop
Power/overload protection light changed to red,
LCD displays “Er 03”, indicate the current failure
is “overload protection”.
Pressing the speed/timer control knob first to
close rotating function, and then restart rotating
function after lowered load. If rotating function
cannot start, then repeat the process and gradually
reduce load.
6
Rotator
7. Maintenance and Cleaning
•Proper maintenance can keep instrument working
properly and lengthen its lifetime.
•Do not spray cleanser into the instrument when
cleaning.
•Do not remove the power line when cleaning. Only
use recommended cleansers:
DyesIsopropyl alcohol
Construction
materials
CosmeticsWater containing tenside /
Foodstuffs Water containing tenside
Fuels Water containing tenside
•Before using other method for cleaning or
decontamination, the user must ascertain with the
manufacturer that this method will not damage the
instrument. Wear the proper protective gloves during
cleaning of the instrument.
Water containing tenside /
Isopropyl alcohol
Isopropyl alcohol
Note:
•Electronic device cannot clean with cleanser.
•If you require maintenance service, must be
cleaned the instrument in advance to avoid
pollution of hazardous substances, and to
send back into original packing.
•If the instrument will not use for a long time,
please switch off and place in a dry, clean,
room temperature and stable location.
8. Associated standards and regulations
Construction in accordance with the following safety
standards:
EN 61010-1
UL 3101-1
CAN/CSA C22.2(1010-1)
EN 61010-2-10
Construction in accordance with the following EMC
standards:
EN 61326-1
7
Rotator
Changes or modifications not expressly approved by the
party responsible for compliance could void the user's
authority to operate the equipment.
NOTE: This equipment has been tested and found to
comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful
interference when the equipment is operated in a
commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may
cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be
required to correct the interference at his own expense.
9. Specifications
ItemsSpecifications
Voltage [VAC] 100~240
ItemsSpecifications
Angle range 0°~ 90°
Motor type DC motor
Speed range [rpm] 10~70
Speed display LCD
Timer range [min] 1~1199
Timer display LCD
Permissible relative humidity 80%
Protection class acc. to DIN
EN60529
Timer/Continuous
operation
5-40
IP21
Table 4
Frequency [Hz] 50/60
Power [W] 40
8
Rotator
10. Ordering Informations
Cat. No. Descriptions
MX-RD-Pro, LCD Digital Rotator, used
824232019999
824232119999
824232219999
824232319999
with disk accessories, variable speed,
adjustable mixing angle, US plug,
100V-240V, 50Hz/60Hz
MX-RD-Pro, LCD Digital Rotator, used
with disk accessories, variable speed,
adjustable mixing angle, Cn plug,
100V-240V, 50Hz/60Hz
MX-RD-Pro, LCD Digital Rotator, used
with disk accessories, variable speed,
adjustable mixing angle, Euro plug,
100V-240V, 50Hz/60Hz
MX-RD-Pro, LCD Digital Rotator, used
with disk accessories, variable speed,
adjustable mixing angle, UK plug,
100V-240V, 50Hz/60Hz
824222019999
824222119999
824222219999
824222319999
Accessories
MX-RL-Pro, LCD Digital Rotator, used
with rotisserie accessories, variable
speed,adjustable mixing angle, US plug,
100V-240V, 50Hz/60Hz
MX-RL-Pro, LCD Digital Rotator, used
with rotisserie accessories, variable
speed,adjustable mixing angle, Cn plug,
100V-240V, 50Hz/60Hz
MX-RL-Pro, LCD Digital Rotator, used
with rotisserie accessories, variable
speed, adjustable mixing angle, Euro
plug, 100V-240V, 50Hz/60Hz
MX-RL-Pro, LCD Digital Rotator, used
with rotisserie accessories, variable
speed,adjustable mixing angle, UK plug,
100V-240V, 50Hz/60Hz
Cat. NoDescriptions
18900137
Disk, 1.5ml centrifuge tube,
capacity: 60ea
9
Rotator
Cat. NoDescriptions
18900138
18900139
18900140
Disk, 15ml centrifuge tube,
capacity: 16ea
Disk, 50ml centrifuge tube,
capacity: 8ea
Post for installing disk
together
1.5ml Centrifuge tube,
18900142
capacity: 48ea, horizontal
mount
15ml Centrifuge tube,
18900143
capacity: 24ea, horizontal
mount
50ml Centrifuge tube,
18900144
capacity: 24ea, horizontal
mount
Cat. NoDescriptions
18900145
1.5ml Centrifuge tube,
capacity: 32ea, vertical mount
15ml Centrifuge tube,
18900146
capacity: 16ea, vertical
mount
50ml Centrifuge tube,
18
900147
capacity: 16ea, vertical
mount
Table 5
10
Rotator
Inst
alling rotisserie attachment
Changing attachment
11
SCILOGEX, LLC
1275 Cromwell Ave.
Suite C6
Rocky Hill, CT 06067 USA
Tel: +1(860) 436-9221
Fax: +1(860) 436-9745
info@scilogex.com | www.scilogex.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.