Scilogex MS7-S,MS7-H550-S User Manual

LED Digital 7’’ Square Hotplate Stirrer
12300085
Contents
Preface ................................................................................. 1
Service ................................................................................. 1
Warranty .............................................................................. 1
1. Safety Instructions ....................................................... 2
2. Proper use .................................................................... 3
3. Inspection .................................................................... 4
3.1 Receiving Inspection ............................................. 4
3.2 Listing of Items ..................................................... 4
4. Control ......................................................................... 4
4.1 Control elements .................................................... 4
4.2 Display (Hotplate Model) ...................................... 6
5. Trial run ....................................................................... 6
6. Working with external temperature sensor (Hotplate
Model) ................................................................................. 7
7. Faults ........................................................................... 8
8. Maintenance and Cleaning .......................................... 8
9. Associated standards and regulations .......................... 9
10. Technical data .............................................................. 9
11. Ordering information ................................................. 10
1
LED Digital 7 Square Hotplate Stirrer
Preface
Welcome to the LED Digital 7” Square Hotplate Stirrer. Users should read this Manual carefully, follow the instructions and procedures, and be aware of all the cautions when using this instrument.
Service
When help needed, you can always contact the Service Department of manufacturer for technical support in the following ways:
SCILOGEX, LLC 500 Four Rod Road Suite 122 Berlin, CT 06037 USA Tel1- (860) 828-5614 Fax1- (860) 828-5389 E-mail: info@scilogex.com WebsiteHttp://www.scilogex.com
Please provide the customer care representative with the following information
• Serial numberon the rear panel
Certification
• Description of problem (i.e., hardware or software)
• Methods and procedures adopted to resolve the problems
• Your contact information
Warranty
This instrument is warranted to be free from defects in materials and workmanship under normal use and service, for a period of 24 months from the date of invoice. The warranty is extended only to the original purchaser. It shall not apply to any product or parts which have been damaged on account of improper installation, improper connections, misuse, accident or abnormal conditions of operation. For claims under the warranty please contact your local supplier. You may also send the instrument directly to manufacturer, enclosing the invoice copy and by giving reasons for the claim.
2
LED Digital 7 Square Hotplate Stirrer
1. Safety Instructions
Warning!
Read the operating instructions carefully
before use.
Ensure that only trained staff works with the
instrument.
Risk of burn!
Caution when touch the housing parts and
the hotplate which can reach temperature of 550°C.
Pay attention to the residual heat after
switching off.
Protective ground contact
Make sure that socket must be grounded
(protective ground contact) before use.
• When working wear personal safety guards to avoid the risk from:
- Splashing and evaporation of liquids
- Release of toxic or combustible gases
• Set up the instrument in a spacious are on a stable, clean, non-slip, dry and fireproof surface. Do not operate the instrument in explosive atmospheres, with hazardous
substances or under water.
• Gradually increase the speed, reduce the speed if:
- Stirring bar breaks away due to high speed
- The instrument is not running smoothly, or container
moves on the base plate
• Temperature must always be set to at least 50 lower than the fire point of the media used.
• Be aware of hazards due to:
- Flammable materials or media with a low boiling
temperature
- Overfilling of media
- Unsafe container
• Process pathogenic materials only in closed vessels.
• Check the instrument and accessories prior to each use.
Do not use damaged components. Safe operation is only guaranteed with the accessories described in the Accessorieschapter. Accessories must be securely attached to the device and can not come off by themselves. Always disconnect the plug before fitting accessories.
When the external temperature sensor needed, the tip of
the measuring sensor must be at least 5-10mm from vessel bottom and wall.
3
LED Digital 7 Square Hotplate Stirrer
• The instrument can only be disconnected from the main power supply by pulling out the main or the connector plug.
• The voltage stated on the label must correspond to the main power supply.
• Ensure that the main power supply cable does not touch the hotplate. Do not cover the device.
Forbid to put pressure and over heat media on the surface of glass ceramic, that can be caused surface broken.
• The instrument may only be opened by experts.
• Keep away from high magnetic field.
2. Proper use
The instrument is designed for mixing and/or heating liquids in schools, laboratories or factories.
Observe the minimum distances between the devices, between the device and the wall and above the assembly (min. 100 mm)
>100mm
>100mm
Figure 1 This device is not suitable for using in residential areas or other constraints mentioned in Chapter 1.
Loading...