Scilogex 83101005 User Manual

SK-O(L)330- Pro Orbital and Linear Digital Shaker
S K - O ( L )1 8 0 - Pro Orbital and Linear Digital Shaker
User Manual
Cat No.12300140
SK-L330-Pro SK-O330-Pro SK-L180-Pro SK-O180-Pro
Please read the User Manual and the related Video of this instrument on our website carefully before use, and follow all operating and safety instructions! The website www.scilogex.com
Linear Digital shaker(7.5Kg) Orbital Digital shaker(7.5Kg) Linear Digital shaker(2.5Kg) Orbital Digital shaker(2.5Kg)
Contents
Contents Inside front cover Preface 1 Service 1 Warranty 1
1.Safety Instructions 2
2.Proper Use 3
3.Inspection 3
3.1 Receiving Inspection 3
3.2 Listing of Items 3
4. Trial Run 3
5.Control and Set 4
5.1 Control 4
5.2 Set 5
5.2.1 Set Time 5
5.2.2 Setting Speed 5
6.Operating Modes 6
6.1 Mode A 6
6.2 Mode B 7
6.3 Switching the Mode 7
6.4 Switch the shaking direction 8
7.Supported Load 8
8.Faults 8
9.Interface 8
10.Maintenance and Cleaning 9
11.Associated Standards and Regulations 9
12.Technical Data 10
13.Products and Accessories 10
1
SK-O(L)330- Pro Orbital and Linear Digital Shaker SK-O(L)180- Pro Orbital and Linear Digital Shaker
Preface
Welcome to theOrbital and Linear Digital Shaker User Manual. Users should read this manual carefully, follow the instructions and procedures, and beware of all the cautions when using this instrument.
Service
When help needed, you can always contact manufacturer for technical support in the following ways: SCILOGEX, LLC 500 Four Rod Road Suite 122 Berlin, CT 06037 USA Tel1- (860) 828-5614 Fax1- (860) 828-5389 E-mail: info@scilogex.com WebsiteHttp://www.scilogex.com
Please provide the customer care representative with the following information:
Serial Numberon the rear panel
Description of problem (i.e., hardware or software)
Methods and procedures adopted to resolve the problems
Your contact information
Warranty
You have purchased a Scilogex instrument. This instrument is warranted to be fre e from defects in materia ls and workmanship under normal use and service, for a period of 24 months from the date of invoice. The warranty is extended only to the original purchaser. It shall not apply to any product or parts which have been damaged on account of improper installation, improper connections, misuse, accident or abnormal conditions of operation. For claims under the warranty please contact your local dealer. You may also send the instrument direct to our works, enclosing the invoice copy and by giving reasons for the claim. You would be solely liable for freight costs.
2
SK-O(L)330- Pro Orbital and Linear Digital Shaker SK-O(L)180- Pro Orbital and Linear Digital Shaker
1.Safety Instructions
Warning!
Read the operating instructions completely before use and follow the safety instructions.
Ensure that only trained staff work with the instrument.
Protective ground contact
Make sure the socket must be earthed (protective ground contact) before use.
Wear the personal protective equipment in accordance with the hazard category of the media to be processed.
- Splashing of liquids.
- vibration force led to broken glass container.
- The bodyhairclothesjewelry are inhaled.
Use the instrument following the safety instruction profession safety rules to avoid any accident.
Users are not allowed to touch moving parts of the instrument to avoid any accidents. Pay attention to protect hands or fingers from rolling when moving the instrument.
Set up the instrument in a spacious area on an stable, clean, non-slip, dry and fireproof surface. Do not operate the instrument in explosive atmospheres, with hazardous substances or under water.
Observe the vessel on the shaking table for medium
s and
splashing out of liquid when setting the motor speed. Reduce the motor speed if the instrument is not running smoothly.
Accessories must be securely attached to the instrument so that it cannot come off by itselves, and vessels must be firmly placed on the shaking table to avoid any injury.
Working with combustible med
ia or flammable materials may result in additional hazards. Only process media that will not react dangerously to the extra energy produced through processing should be used on the instrument.
Safe operation is only guaranteed with the accessories described in the Accessories chapter and by following the operating instructions in full. Always disconnect the plug before fitting accessories. Check the instrument and accessories beforehand for damage each time you use them. Do not use damaged components.
The instrument may only be opened by trained technicians. And always disconnect the plug beforehand.
The operating voltage required as stated on the instrument and voltage in the supply network must match.
Do not cover the instrument. Protect the instrument and accessories from bumps and impacts.
Keep away from high magnetic field.
3
SK-O(L)330- Pro Orbital and Linear Digital Shaker SK-O(L)180- Pro Orbital and Linear Digital Shaker
2.Proper use
The instrument is designed for mixing or shaking liquids in schools, laboratories or factories. SK-330/180-Pro is suitable for usage in various attachments for mixing liquids in bottles, flasks, test tubes for a maximum supported weight of
7.5 kg(330)and 2.5Kg(180). This instrument is not suitable for use in residential areas or other areas that may cause danger to the user or instrument as mentioned in chapter 1.
3.Inspection
3.1 Receiving Inspection
Unpack the instrument carefully and check for any damages which may have arisen during transport. If it happens, please contact manufacturer for technical support.
Note: If there is any apparent damage to the system, please do not plug it into the power line.
3.2 Listing of Items
The packing includes the following items:
Items Qty
Main unit 1
Power cable 1
User manual 1
Table 1
4. Trial run
Do trial operation as follows:
Make sure the required operating voltage and power supply voltage match.
Ensure the socket is securely earthed.
Plug in the power cablePower ON the instrument.
LCD displays the safe rotary speed limit.
LCD displays operating mode.
Turn the speed knob to set the rated rotary speed
Press the speed knob. And the shaking function is switched
ON.
Press the motor regulation knob again. and the shaking function is switched OFF. If these operations above are normal, the instrument is ready to operate following the operation chapter. If these operations are not normal, the instrument may be in security protection state or be damaged.
4
SK-O(L)330- Pro Orbital and Linear Digital Shaker SK-O(L)180- Pro Orbital and Linear Digital Shaker
If the mounting surface is not even, you can improve the stability of the instrument with the adjustable feet. To do this, turn the appropriate foot downward with the wrench until the instrument is standing securely on the surface.
Figure 1
5.Control and Set
5.1 Control
LCD time
LCD speed
Items Descriptions
Set the rated rotary speed. rotation
Speed knob
Time knob
LCD
Mains switch Switch ON or OFF.
is switched ON or OFF via pressing the knob.
Se t wo rk i n g ti me . r ot a t i on is switched ON or OFF via pressing the knob
Display the status of instrument and any set
Time knob
Figure 2
Table 2
Shaking table
5
SK-O(L)330- Pro Orbital and Linear Digital Shaker SK-O(L)180- Pro Orbital and Linear Digital Shaker
Put the instrument on stable and safe place and plug in the mains power.
Turn ON the mains switch on the left panel.
The instrument starts self-test.
Th e in s t rume n t sh o w s r a ted spee d an d ti m e af t e r
initialization.
Turn the speed knob on the left side to set the rated speed.
Press the speed knob and characters on the left LCD do
not flash any more, and the shaking function is switched ON.
Press the speed knob again and characters on the left LCD begin to flash, and the shaking function is switched OFF.
Turn the time knob on the left side to set the rated time
Press the time knob and characters on the LCD do not
flash any more, and the timing function is switched ON.
Press the time knob again and characters on the right LCD begin to flash, and the timing function is switched OFF.
5.2 Set
5.2.1 Set time
The rated shaking time can be set by turning the time knob on the right. A distinction is made for the shaking time setting between timed mode and continuous operation. If continuous mode is selected, the shake can continue its shaking function for any amount of time with the previously set speed. If timed mode is selected, the shaker can run in the
set time. After the instrument is powered OFF and restarted, the set time is erased to zero blanking and it switches into offline operating mode. If a target time (max. 19h 59min) and speed are set, users can activate the instrument with pressing the time knob and the time begin to read,If: Apressin g the time knobt he speed and the tim e will stop. Pressing the time knob again,restart the shake function,the time will use the pre-set time Bpressing the speed knobthe speed and the time will stop; Pressing the time knob again,restart the shake function,the time not(There are flashing on the righe of the LCD )pressing the time knob again restart the time function. The time will use the pre-set time.
Note: The current set time can be varied at any time.
5.2.2 Setting Speed
The rated speed and upper speed limit can be set by turning the speed knob (As the Figure 6) . The continuous mode can be switched ON with pressing the left knob without the time setting and switched OFF with pressing the knob again.. Adjust the motor speed knob slowly in order to keep the instrument running smoothly.
6
SK-O(L)330- Pro Orbital and Linear Digital Shaker SK-O(L)180- Pro Orbital and Linear Digital Shaker
Note: The current set speed can be varied at any time.
Figure 4
6.Operating modes
6.1 Mode A
Operating mode A is the default mode set in factory. After turning ON the instrument with the mains switch, the shaking and timing functions are turned OFF. The LCD displays the set time and speed values. They are adopted or varied when the corresponding functions are turned ON. After turning ON the instrument, the following process will be shown on the display.
The left LCD displays SAF and the right displays the upper speed limit( rpmwhich can be set by pressing the speed knob and turning at the same time.
The set or stored speed value is shown in the left display, and the set or stored time value is shown in the right display. Turn the speed knob and time knob can set the speed and time.
Figure 5
After pressing the speed knob or time knob, the instrument begins to run at the set speed. The actual speed and time remaining are shown in the LCD. If the remaining has reached zero, the shaker stops its motion. Pressing the speed knob alone,the instrument will work at continuous mode(The time function is OFF)
Figure 3
The LCD displays run modes StA”、“A or B for about 2 seconds.
Figure 6
Note: The set values can be varied during shaking. Shaking can be stopped by pressing the left or right knob.
7
SK-O(L)330- Pro Orbital and Linear Digital Shaker SK-O(L)180- Pro Orbital and Linear Digital Shaker
6.2 Mode B
When the instrument is turned ON and values for speed and time are erased to zero, users can set. The upper speed limit that has been set is taken over from operating mode A and cannot be modified. After the power has been turned OFF, the instrument will no longer automatically start up in operating Mode B by itself. After turning ON the instrument and selected run mode, the following process will be shown on the display.
The left LCD displays SAF and the right displays the upper speed limit( rpmwhich cannot be changed.
Figure 7
T he LCD display s run mod es St A for about 2 seconds.
Figure 8
The set speed value is shown in the left display, and the set time value is shown in the right display. Then set the motor rotary speed and time.
Figure 9
Figure 10
After pressing the speed knob or time knob, the instrument begins to run at the set speed. The actual speed and time remaining are shown in the LCD. If the remaining has reached zero, the shaker stops its motion.
Figure 11
Note: The set values can be varied during shaking. Shaking can be stopped by pressing the left or right knob.
6.3 Switching the mode
Switch the operating mode as follows:
Turn OFF the instrument with the mains switch.
Hold down both knobs and turn ON the instrument with
8
SK-O(L)330- Pro Orbital and Linear Digital Shaker SK-O(L)180- Pro Orbital and Linear Digital Shaker
the mains switch. After about 5 second, you can let go of the knobs.
Switch between operating Modes A and B in order.
6.4 Switch the shaking direction
Change the shaking direction according to the steps as follows:
Turn OFF the instrument;
Press and hold time knob, at the same time turn on the
instrument, release the time knob after 10 seconds;
Switch the operation direction in turn.
7.Supported load
In order to ensure safe, the shaker must only be operated within the supported weight (7.5kg for 330 and 2.5Kg for
180). Make sure the holding surface of the shaker is always clean and level. Ensure the individual shaking vessels must be placed evenly and fastened securely in the middle of the shaking table no matter one or multiple shaking vessels are placed.
8.Faults
When switched ON, the instrument doesnt work
■ Check whether the power cable fitted well
■ Check whether the fuse is broken
The speed cannot reach set value
■ Check whether it is overloaded
The motor does not start via pressing the speed knob and time knob
■ Check whether the time is set to zero
9.Interface
SK-O330(180)-Pro/ SK-L330(180)-Pro Orbital and Linear Digital Shaker, special adapter and cable are used to link to external device.and the Standard 9-pin interface to connect with the PC.
The cable between the shaker and the computer used EIA Standard RS232C communication linecorresponding to the DIN 66020 interface.
Transmission method: Asynchronous signal transmission.
Mode of transmission: Fully Duplex.
1 start bit; 8 character bits; 1 stop bit.
Transmission speed: 9600 bit/s
Note Forbid to plug in and plug off the power cable when the instrument working
9
SK-O(L)330- Pro Orbital and Linear Digital Shaker SK-O(L)180- Pro Orbital and Linear Digital Shaker
10.Maintenance and cleaning
Use and maintain the instrument in right way to keep it in good operating state in order to lengthen its life time and avoid the damage to the instrument. Only use the cleaning agents which have been approved by manufacturer to clean the instrument.
Only use cleanser that we advised as below
Dyes Isopropyl alcohol
Construction materials
Cosmetics
Foodstuffs Water containing tenside
Fuels Water containing tenside
For ma te r ia l s wh i ch ar e not list e d, pl ea s e re q ues t information from manufacturer or your supplier. Before using another than the recommended method for cleaning or decontamination, the user must as does not destroy the instrument. Wear the proper protective gloves during cleaning of the instrument.
Water containing tenside / isopropyl alcohol
Water containing tenside / isopropyl alcohol
certain that this method
Note:
Electrical instrument may not be placed in the cleansing agent for the purpose of cleaning.
The instrument must be cleaned and put it into the initial packaging carton before sending to service for repair, avoiding the contamination of hazardous.
Switch OFF the instrument and put it in the dry, clean, stable place at room temperature in long-term disuse.
11.Associated standards and regulations
Construction in accordance with the following safety standards
EN 61010-1 UL 3101-1 CAN/CSA C22.2(1010-1) EN 61010-2-10
Construction in accordance with the following EMC standards
EN 61326-1
10
SK-O(L)330- Pro Orbital and Linear Digital Shaker SK-O(L)180- Pro Orbital and Linear Digital Shaker
12.Technical data
Items Parameters
Voltage [VAC] 100~240
Frequency [Hz] 50/60
Power [W] 30
Shaking movement Orbital/ linear
Orbital diameter [mm]
Max. shaking weight (with attachment) [kg]
Motor type
Motor rating input [W] 28
Motor rating output [W] 15
Permissible ON time [%] 100
Speed range [rpm]
Speed display LCD
Timer Yes
10SK-O(L)330-Pro/
4.5SK-O(L)180-Pro
7.5SK-O(L)330-Pro/
2.5SK-O(L)180-Pro
External rotor brushless motor
100-350(SK-L330-Pro) 100-500(SK-O330-Pro) 100-350(SK-L180-Pro) 100-800(SK-O180-Pro)
Timer display LCD
Time setting range [min] 1 – 1199
Items Parameters
Run type Time / Continuous operation
Dimensions [D×W×H mm]
Weight [kg]
Permissible ambient temperature [°C]
Permissible relative humidity
Protection class acc. To DIN EN60529
420×370×100(SK-O(L)330­Pr o) / 3 4 0 × 3 0 0 × 1 0 0 ( SK ­O(L)180-Pro)
13.5( SK-O(L)330-Pro)/
8.1(SK-O(L)180-Pro)
540
80%
IP21
RS232 interface Yes
Table 3
11
SK-O(L)330- Pro Orbital and Linear Digital Shaker SK-O(L)180- Pro Orbital and Linear Digital Shaker
13.Products and Accessories
Cat.No Descriptions
SK-L180-Pro Linear Digital Shaker
831010019999
831010039999
831010049999
831010059999
832010019999
832010039999
(2.5Kg),No Attachment, Cn plug, 110/220/50Hz/60Hz
SK-L180-Pro Linear Digital Shaker (2.5Kg),No Attachment, Euro plug, 110/220/50Hz/60Hz
SK-L180-Pro Linear Digital Shaker (2.5Kg),No Attachment, UK plug, 110/220/50Hz/60Hz
SK-L180-Pro Linear Digital Shaker (2.5Kg),No Attachment, USA plug, 110/220/50Hz/60Hz
SK-
O180-Pro Orbital Digital Shaker
(2.5Kg)No Attachment, Cn plug, 110V/220V/50Hz/60Hz
SK -O 1 8 0 - P ro Or b i t al Di g i t al Shaker (2.5Kg)No Attachment, Euro plug, 110V/220V/50Hz/60Hz
Cat.No Descriptions
SK-O180-Pro Orbital Digital Shaker
832010049999
(2.5Kg)No Attachment, UK plug, 110V/220V/50Hz/60Hz
SK -O 1 8 0 - P ro Or b i t al Di g i t al
832010059999
Shaker (2.5Kg)No Attachment, USA plug, 110V/220V/50Hz/60Hz
SK-L330-Pro Linear Digital Shaker
831010029999
(7.5 Kg)No Attachment, Cn plug, 110V/220V/50Hz/60Hz
SK-L330-Pro Linear Digital Shaker
831010069999
(7.5 Kg)No Attac hment, Eur o plug, 110V/220V/50Hz/60Hz
SK-L330-Pro Linear Digital Shaker
010079999
831
(7.5 Kg)N o At t a c hment , UK plug, 110V/220V/50Hz/60Hz
SK-L330-Pro Linear Digital Shaker
831010089999
(7.5 Kg)No Attachment, US A plug, 110V/220V/50Hz/60Hz
SK-O330-Pro Orbital Digital Shaker
832010029999
(7.5 Kg)No Attachment, Cn plug, 110V/220V/50Hz/60Hz
12
SK-O(L)330- Pro Orbital and Linear Digital Shaker SK-O(L)180- Pro Orbital and Linear Digital Shaker
Cat.No Descriptions
SK -O 3 3 0 - P ro Or b i t al Di g i t al
832010069999
Shaker (7.5 Kg)No Attachment, Euro plug, 110V/220V/50Hz/60Hz
SK -O 3 3 0 - P ro Or b i t al Di g i t al
832010079999
Shaker (7.5 Kg)No Attachment, UK plug, 110V/220V/50Hz/60Hz
SK -O 3 3 0 - P ro Or b i t al Di g i t al
832010089999
Shaker (7.5 Kg)No Attachment, USA plug, 110V/220V/50Hz/60Hz
Accessories
Accessories
Figure
Cat.No and
Designation
18900027
SK330.1
18900040
SK330.3
Operation mode
SK 330.1 Universal Attachment
SK330.3 Lengthways Roller Attachment
18900041
SK330.4
18900028
SK 330.2
18900036
18900025
SK 180.1
18900038
SK180.3
18900039
SK180.4
SK330.4 Dish Atta c h men t (w i th slip-resistant foil)
SK 330.2 Fixing Clip Attachment
Bars for SK330.1 Universal Attachment black
SK 180.1 Universal Attachment
SK180.3 Lengthways Roller Attachment
SK180.4 Dish Atta c h men t (w i th slip-resistant foil)
SK-O(L)330- Pro Orbital and Linear Digital Shaker SK-O(L)180- Pro Orbital and Linear Digital Shaker
18900026
SK 180.2
18900037
18900029
SK330.2.1
18900030
SK330.2.2
18900031
SK330.2.3
SK 180.2 Fixing Clip Attachment
Bars for SK180.1 Universal Attachmentblack
Fixing Clips for Flask Volume 25 ml
F i x i n g Cl i p s fo r Flask Volume 50 ml
F i x i n g Cl i p s fo r Fl ask Volum e 100 ml
18900032
SK330.2.4
18900033
SK330.2.5
18100319 RS232 9-Pin interface line
Table 4
F i x i n g Cl i p s fo r F l a s k V o l u m e 200/250 ml
F i x i n g Cl i p s fo r Fl ask Volum e 500 ml
Suitable to shakerPC Software used
Note: The software ShakerPC can be download free on our website www.scilogex.com.
SCILOGEX, LLC
500 Four Rod Road
Suite 122
Berlin, CT 06037
USA
Tel1- (860) 828-5614
Fax1- (860) 828-5389
E-mail: info@scilogex.com
WebsiteHttp://www.scilogex.com
Loading...