SCIFIT PRO2,PRO1000 User's Operation Manual

Users’ Operations Manual
PRO2
®
PRO1000
PRO2
®
Total Body Exerciser
&
PRO1000 Upper Body Exerciser
Before using this product, read this manual and follow all safety rules and operating instructions.
This page purposely left blank
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
TABLE OF CONTENTS
SAFETY INFORMATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SETUP & INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 14
PRODUCT OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
KEYPAD FUNCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
BIOMECHANICAL POSITIONING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-19
ACCESSORIES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-21
HEART RATE TRANSMITTER STRAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
PROGRAM INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23-31
MAINTENANCE & SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33-37
Order Online 24/7 at www.SCIFIT.COM
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
SAFETY INFORMATION
The purpose of safety symbols is to attract your attention to possible dangers. The safety symbols, and their explanations, deserve your careful attention and understanding. The safety warnings do not, by themselves, eliminate any danger. The instructions or warnings they give are not substitutes for proper accident prevention measures.
Look for these symbols to point out important safety precautions. It means attention! Your safety is involved.
WARNING
Failure to obey a safety warning can result in injury to yourself and others. Always follow the safety precautions to reduce the risk of personal injury.
CAUTION
Failure to obey a safety caution can result in injury to yourself and others. Always follow the safety precautions to reduce the risk of personal injury.
Read all instructions before using your SCIFIT exercise machine. Save these instructions for future reference.
Close supervision is necessary when exercise machine is being used by or near children, or individuals with disabilities. Keep children away from extended hand and foot supports.
Use the exercise machine only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer.
Never drop or insert any object into any opening.
Do not use outdoors or in a harsh environment where water is present (i.e. pool or spa areas).
1
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
INTRODUCTION
Thank you for your purchase of the SCIFIT PRO2 Total Body Excerciser or PRO1000 Upper Body Exerciser. We have incorporated the finest technology and ergonomic design into this machine to assist you in achieving your fitness goals. However, for your safety, please adhere to the following recommendations before you begin to exercise.
The SCIFIT PRO2 and PRO1000 are designed for Class “S” (Studio), Class “I” (Special Needs) and Class ”II a” (Medical Device Directive) applications. The intended uses are for Cardio & Pulmonary Rehabilitation as well as Sports Medicine, Physical Therapy, Physical Conditioning and Strength Training. SCIFIT equipment is suitable for placement in fitness, medical rehab, sports performance and recreational facilities. 200 levels of computer controlled resistance ensures that users of all fitness levels will be able to get a challenging but not overwhelming workout.
Consult Your Physician
Consult your physician or medical specialist before participating in any exercise p you are pregnant, or if you are suffering from: heart disease, respiratory disease, diabetes, hypertension, high blood pressure, elevated cholesterol, arthritis, or any other diseases or physical complaints.
Adult Usage
SCIFIT equipment is designed and intended for adult usage and children of appropriate ages while being supervised. Young children should be kept a safe distance away from equipment.
Cool Down
To prevent muscle injuries and soreness, you should always cool down (at least 5 minutes) by doing a series of stretches after each workout.
rogram, especially if
®
CAUTION
Always stretch after a workout session to reduce the risk of personal injury. Failure to stretch properly may result in injury to yourself.
Guidelines for Healthy Adults
The American College of Sports Medicine (ACSM) and the American Heart Association (AHA) are continuously updating guidelines and recommendations for physical activity.
The current basic recommendations from ACSM and AHA is:
Do moderately intense cardio 30 minutes a day, ve days a week. OR Do vigorously intense cardio 20 minutes a day, three days a week. AND Do eight to ten strength-training exercises, eight to twelve repetitions of each exercise twice a week.
Moderate-intensity physical activity means working hard enough to raise your heart rate and break a
It should be noted that to lose weight or maintain weight loss, 60 to 90 minutes of physical activity may be necessary. The 30 minute recommendation is for the average healthy adult to maintain health and reduce the risk for chronic disease.
To review the latest guidelines and recommendations,
deM stropS fo egelloC naciremA eht tisiv
www.acsm.org
WARNING
Stop exercising immediately if you feel nausea, dizziness, sharp pain, or any other physical discomfort. Failure to stop excercising can result in injury or death to yourself.
Train Intelligently
To ensure a future of good health, you should always eat well balanced meals, drink plenty of fluid/water
Always follow training guidelines that are specific for your own physical condition.
WARNING
Injuries to health may result from incorrect or excessive training. Failure to stop excercising can result in injury or death to yourself.
.noitasrevnoc a no yrrac ot elba gnieb llits tey ,taews
:etisbew enici
.yltnegilletni gnisicrexe yb tfi yats dna ,tuokrow a gnirud
2
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
SPECIFICATIONS
Weight . . . . . . . . . PRO2 - 230 lbs. / 104 Kg. . . . . . PRO1000 - 220 lbs. / 100 Kg.
Max User Weight . . 350 lbs. / 159 Kg.
Power . . . . . . . . . . Self generating w/auto recharge battery back-up.
Optional Low Voltage AC adapter available. Resistance System . Electromagnetic Self Generating Bi-directional Resistance
Work Load . . . . . . . Manual, Fit Quik, Constant Workout, ISO-Strength, 7 Pre-programmed Hills profiles
Heart Rate, Power Fit Test, Power Fit Training, Heart Fit Test, Heart Fit Training
Stress Test and Random
Accuracy Class. . . . . Class A
Warranty . . . . . . . . Within U.S. & Canada 3 years parts, 1 year labor
Outside U.S. 3 years parts, no labor
61”
1524 mm
30”
762 mm
61.5”
1562 mm
3
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
SETUP & INSTALLATION
Placement of Cardiovascular Machine
To aid in the placement of equipment, two wheels are located on the front of the unit. Movement of machine should be done with two people. Carefully lift the rear of unit until wheels are engaged on floor and position unit in desired location.
Position the unit in a location that has a stable and level sub-floor. Equipment should be positioned in a location that is not in direct sunlight, in areas of extreme temperature and humidity, or where the equipment may be splashed with water or fluids. This machine is intended for indoor use only.
Equipment should be positioned with a safety perimeter of 40” or 1 meter around unit.
WARNING
Failure to place the equipment on a stable and level
sub-floor with a safety perimeter can result in injury to yourself and others.
Endcap
40” / 1 Meter
Safety Space
40” / 1 Meter
Safety Space
Endcap
40” / 1 Meter
Safety Space
Level Cardiovascular Machine
If the sub-floor is unlevel, the unit is equipped with leveling end caps. The end caps are designed with the recess of end cap off centered. This allows you to rotate the endcap(s) to a position that will level the equipment. After adjustment, check and make sure end caps ar
e fully seated against base frame tubes.
Offset Endcap
40” / 1 Meter
Safety Space
Proper Supervision
Close supervision is required when the exercise machine is being used by or near individuals with disabilities. Keep unsupervised children outside the safety perimeter.
Cleaning
Never clean the machine with organic solvents, alcohol or bleach based cleaners. To promote a healthy environment, wipe any sweat off of unit with a commercially manufactured wipe designed for the fitness industry, or a damp cloth.
4
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
ASSEMBLY
Assembly
For equipment that is shipped overseas, some assembly is required. Follow the steps below for assembly.
Required Tools:
Required Parts:
Item Qty. Description Part #
1 6 3/8” x 1” Socket HD Cap Bolt N/A
2 6 3/8” Split Lock Washer N/A 3 6 3/8” Flat Washer N/A
Long Needle Point Center Punch 5/16” Allen Drive Socket
Ratchet Torque wrench
Assemble Monocoque Frame to Base Frame
With the aid of a second person, align bottom mounting threaded nutserts of Monocoque Frame with the Base Frame mounting holes.
Starting on the right side, (A) Insert a long needle point center punch through the front threaded mounting hole of the base frame. (B) Push up on the frame until the nut-serts are aligned with the mounting holes (C) Slide (Qty.1) 3/8” split washer and (Qty.1) 3/8” flat washer onto three 3/8” bolts, align and loosely thread two of the bolts into remaining open mounting holes. (D) Remove the center punch and loosely thread in the third bolt.
(E) Repeat step A-D for the left side. (F) Tighten all bolts to 48 ft/lbs or 576 in/lbs (65 nm).
(B)
(C)
(E)
3
2
1
(D)
(A)
5
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
ASSEMBLY
SWIVEL SEAT ASSEMBLY
Step 1:
Pull upward the yellow paddle handle of the seat adjustment lever, then lift and slide the seat post onto the frame track making sure the roller guide rail is between the top and bottom wheels of the base.
Roller guide
Step 2:
Attach the handlebar plate to the seat post with (Qty. 4) of items #1, #2, #3 and #4 as shown on the drawing below.
#1
Tools Required:
3/16 Hex wrench 1/2 Wrench or socket
#2 #3 #4
Item #1 (x 4) 5/16-18 x 1 Socket Flat Head Screw
Item #2 (x 4) 5/16 Flat Washer
Item #3 (x 4) 5/16 Split Washer
Item #4 (x 4) 5/16 Nut
SCIFIT • Scientific
Solutions for Fi
6
tness • SCIFIT • Scientific
Solutions for Fi
tness •
SCIFIT
ASSEMBLY
SWIVEL SEAT ASSEMBLY CONT’D
Step 3: (Bucket Seat Assembly )
a. Align the front holes of the bucket seat with the 3rd set of holes from the front of the handlebar plate, (see diagram), then loosely screw in (Qty. 1) of item #1 into one of the front holes. b. Align the other three holes and loosely screw in item #1 into each hole. c. Tighten all four screws to secure the bucket seat.
Front holes for Bucket seat
Tools Required:
1/2 Wrench or socket
Item #1 (x 4) 5/16-18 x 1.25 Serrated Screw
Rear holes for Bucket seat
#1
Step 3a: (2-Piece Seat Assembly)
a. Align the front two holes of the seat mount plate with the 1st set of holes of the handlebar plate (see diagram), then insert (Qty. 1) of item #1 into one of the front holes to hold the seat mount plate in place. b. Align the front hole of the bottom seat pad with the inserted screw and loosely screw it into the seat pad. c. Align the other front hole of the seat pad and loosely screw in (Qty. 1) of item #1 screw. d. Slide (Qty. 1) of item #3, then (Qty. 2) of item #4 onto each item #2 screws, then loosely screw them into the rear two holes of the seat pad. e. Tighten all four screws to secure the bottom seat pad and plate mount.
Two front holes to mount Seat plate
Tools Required:
1/2 Wrench or socket
Bottom Seat Pad
Item #1 (x 2) 5/16-18 x 1.25 Serrated Screw
Item #2 (x 2) 5/16-18 x 1 Hex Head Screw
Item #3 (x 2) 5/16 Split Washer
Item #4 (x 4) 5/16 Flat Washer
SCIFIT • Scientific
Solutions for Fi
Rear holes to mount Seat plate
7
tness • SCIFIT • Scientific
#1 #2
Solutions for Fi
Seat Mount Plate
#4 #3
SCIFIT
tness •
ASSEMBLY
FIXED SEAT ASSEMBLY
Step 1:
Pull upward the yellow knob of the seat adjustment lever, then lift and slide the seat post onto the frame track making sure the roller guide rail is between the top and bottom wheels of the base.
Roller Guides
Step 2: (Bucket Seat Assembly)
a. Align one of the front two holes of the Bucket seat with the front set of holes on the fixed seat mount (see diagram), then insert (Qty. 1) of item #1 into one of the seat holes and loosely tighten into place. b. Align the second front hole of the seat and loosely tighten with (Qty. 1) item #1 screw. d. Insert and loosely tighten the remaining two rear holes with (Qty. 2) item #1 screws. e. Tighten all four screws to secure the seat to the fixed seat mount.
Align holes of seat with these holes on the fixed seat mount.
Tools Required:
1/2 Wrench or socket
Front
Item #1 (x 4) 5/16-18 x 1.25 Serrated Screw
SCIFIT • Scientific
Solutions for Fi
8
tness • SCIFIT • Scientific
Solutions for Fi
Rear
tness •
SCIFIT
ASSEMBLY
FIXED SEAT ASSEMBLY CONT’D
Step 2a: (2-Piece Seat Assembly)
a. Align the front two holes of the seat mount plate with the 1st set of holes of the fixed seat mount. (see diagram), then insert (Qty. 1) of item #1 into one of the front holes to hold the seat mount plate in place. b. Align the front hole of the bottom seat pad with the inserted screw and loosely screw it into the seat pad. c. Align the other front hole of the seat pad and loosely screw in (Qty. 1) of item #1 screw. d. Align, then loosely screw in (Qty. 2) of item #1 into the two remaining rear holes. e. Tighten all four screws to secure the bottom seat pad and plate mount.
(Item #1) x 4
Low back seat assembly shown for clarity
Tools Req u ired: 1/2” Wrench or socket
Item #1 (x 2) 5/16-18 x 1.25 Serrated Screw
Align bottom seat pad holes with these four hole locations
9
SCIFIT • Scientific S olutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCI FI T
ASSEMBLY
Verify Upper Cranks Are Secure
During shipment it is possible that the two set screws securing the crank hub to the shaft may become slightly loose. It is strongly recommended that these set screws be checked before attaching the crank handles. The following steps will explain this procedure.
Tools Required:
5/ 16 Hex bit Tor que wrenc h set for 480 in/ lbs (5.54 Kg/m).
Step 1:
Starting on the right side, use a 5/16 Hex bit to remove the 1st set screw #P3110 (5/8-18 x .5 Socket) and place to the side.
Step 2:
Using a 5/16 Hex bit and Torque wrench set at 480 in/lbs. Insert the bit into the crank hub to reach the 2nd set screw #P3111 (5/8-18 x .75 Socket) and TIGHTEN to the 480 in/lb
setting on the wrench.
Note: The w ren ch w ill click w hen it has reached the 48
Step 3:
Again using a 5/16 Hex bit and Torque wrench set at 480 in/lbs, reinsert the set screw removed in step 1 into the crank hub and TIGHTEN to the 480 in/lb setting on the wrench.
Step 4:
Repeat steps 1 thru 3 for the left side.
0 in / lb (5.54 Kg/m) setti n g.
10
SCIFIT • Scientific S olutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCI FI T
ASSEMBLY
Verify Lower Cranks Are Secure (PRO2 Only)
During shipment it is possible that the two set screws securing the crank hub to the shaft may become slightly loose. It is strongly recommended that these set screws be checked before attaching the crank handles. The following steps will explain this procedure.
Tools Required:
5/ 16 Hex bit Tor que wrenc h set for 480 in/ lbs (5.54 Kg/m)
Adjustable Lower Cranks (PRO2 Only)
Step 1:
Starting on the right side, use a 5/16 Hex bit to remove the 1st set screw #P3110 (5/8-18 x .5 Socket) and place to the side.
Step 2:
Using a 5/16 Hex bit and Torque wrench set at 480 in/lbs. Insert the bit into the crank hub to reach the 2nd set screw #P3111 (5/8-18 x .75 Socket) and TIGHTEN to the 480 in/lb setting on the wrench.
Note: The w ren ch w ill click w hen it has reached the 48
Step 3:
Again using a 5/16 Hex bit and Torque wrench set at 480 in/lbs, reinsert the set screw removed in step 1 into the crank hub and TIGHTEN to the 480 in/lb setting on the wrench.
Step 4:
Repeat steps 1 thru 3 for the left side.
0 in / lb (5.54 Kg/m) set ting.
11
SCIFIT • Scientific S olutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCI FI T
ASSEMBLY
Verify LWR Fixed Cranks Are Secure (PRO2)
Your machine may have the lower fixed crank hub option, these hubs are usually removed for shipment purposes. If this is the case, attaching them is very simple. The following will explain the steps necessary to attach the hubs.
Tools Required:
5/ 16 Hex bit Tor que wrenc h set for 480 in/ lbs (5.54 Kg/m)
Step 1:
Starting on the left side, slide the hub onto the lower shaft of the machine, allowing 3/4” between the frame and the end of hub. Align the set screw hole over the flat surface area of the shaft, then use a 5/16 hex bit to secure #P3111 (5/8-18 x .75 Socket) set screw as shown in the drawing.
Step 2:
Using a 5/16 Hex bit and Torque wrench set at 480 in/lbs, TIGHTEN the set screw to this setting.
Note: The w ren ch w ill click w hen it has reached the 480 in / lb (5.54 Kg/m) sett i ng.
Step 1
Step 3:
Using a 5/16 Hex bit insert and secure #P3110 (5/16-18 x .5) set screw on top of the set screw #P3111 previously inserted in steps 1 and 2.
Step 4:
Tehn using a 5/16 Hex bit and Torque wrench set at 480 in/lbs, TIGHTEN the set screw as done in step 2.
Note: The w ren ch w ill click w hen it has reached the 480 in / lb setti n g (5.54 Kg/m)
Step 5:
Repeat steps 1 thru 4 for the under side of the hub.
Step 6:
Repeat steps 1 thru 5 for the right side of the machine.
Step 2
Step 3 & 4
12
SCIFIT • Scientific S olutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCI FI T
ASSEMBLY
Assemble Hand Crank Handles to Hubs
Identify Left and Right Hand Crank Handles
Left Hand
Crank Handle
Right Hand
Crank Handle
(A) Insert parallel rods through bearing holes of hub. (B) Pull yellow crank arm locking pin out and push
rods through until end of rod protrudes from farside. (C) To prevent unwanted dropping of crank arm when adjusting crank arm positions, install a 1/4-20 x 1/2” socket button head screw and 1/4” washer into the end of each rod.
Assemble Foot Crank Pedals to Hubs(PRO2 Only)
Identify Left and Right Foot Crank Pedals
Left Foot
Crank Pedal
Right Foot
Crank Pedal
(A) Insert parallel rods through bearing holes of hub. (B) Pull yellow crank arm locking pin out and push
rods through until end of rod protrudes from farside. (C) To prevent unwanted dropping of crank arm when adjusting crank arm positions, install a 1/4-20 x 1/2” socket button head screw and 1/4” washer into the end of each rod.
(A)
1/4-20 x 1/2”
SBH Screw
(A)
(B)
1/4-20 x 1/2”
SBH Screw
(C)
1/4” Washer
(B)
1/4” Washer
(C)
13
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
ASSEMBLY
Optional Wheelchair Platform (#1180)
To install the optional wheelchair platform you must first remove the seat assembly from the base. Pull up on the yellow T-handle seat adjustment rod and slide
the seat assembly completely off the roller track.
Pull T-handle up and hold
Move seat off of roller track
With the aid of an assistant, carefully raise the base up, and lower the work console down until the console is resting on the floor. To prevent damage to the covers place a pad, piece of carpet or cardboard between the case and oor.
(A) With a 1/2” socket, loosen the four back end bolts that secure the stainless steel adjustment track to the base frame just enough to slide the platform under the lockwasher. NOTE: Do not remove the bolts.
(B) Slide the platform slots between the lockwasher and the frame, with the flat surface of the platform flush against the frame.
(C) tighten the four bolts, then repeat the process for the other side.
After securing the platforms with the help of another person, carefully lift and set the machine to it’s normal position, then reinstall the seat assembly the same way it was removed from the seat track.
CAUTION
Monocoque Frame is top heavy.Two people are required to position frame in place. Failure to support frame properly may result in injury to yourself and/or others.
Protective Pad
(A) Loosen Four (4) Bolts
(B) Slide Slots Under Washers
(C) Tighten Bolts
14
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
Adjustable Display
Adjustable or Fixed swivel seat
PRODUCT OVERVIEW
Water Bottle
Holder
Adjustable Arm Crank
Adjustable
Foot Crank
(PRO2 Only)
Wheelchair
Tie Down Anchor
Transport Wheels
Horizontal
Seat Adjustment
Foot Assist
Seat Adjustment Rod
Vertical and Rotational lever
Leveling Base
Endcaps
15
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
Work Level Sta tus LCD Screen -
The Work Level Status L C D Screen gives a progressive real-time indication of the current work level of any and all programs
KEYPAD FUNCTI ONS
Select Workout or Insert Fitkey
Copyright c 1998-2010. SCFIT Systems, Inc.
Press to start or choose a program
-
PAUSE/ CLEAR - The [Pause/Clear] key will pause the workout. Pressing
[Pause/Clear] a second time when in
the pause mode will stop the workout and return to the main screen.
To restart in the paused mode press the[Quick Start] key.
Manual
ENTER -
The Enter Key is pressed to enter selected values for the workout parameters.
Hills
QUI CK START
“Quick Start” into the Manual mode, or after logging into a program.The Quick Start key will activate the selected program.
Random Heart Rate
- This key provides a one-touch
Iso-Strength
More
Profile Selection Area -
Allows the user option to choose from 12 different workout profiles
Up Arow a nd Down Arrow - These keys increase or decrease values of the workout parameters.
16
SCIFIT • Scientific S olutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCI FI T
BIOMECHANICAL POSITIONING
Swivel or Fixed Seat and Wheelchair Use Adjust seat or wheelchair forward or backward to a comfortable location for the upper body movement. A slight torso rotation is desired on extension. Avoid locking arms at extension by adjusting the seat position or arm crank radius. Adjust the height of the cranks to a comfortable position that encourages proper posture or at the desired angle for specific training or rehabilitation movements. Such movements and adjustments should be under the guidance and supervision of a fitness or medical professional. If your Pro2 features a seat with height adjustment, you may adjust either the seat height or the control head to obtain the desired axis of rotation and body position.
Crank Length Adjustment
Adjust the foot and crank arm radius to desired length. The longer the crank arm length the larger the circle the user will experience when exercising. Generally a larger circle will result in broader muscle recruitment and greater torso rotation.
Comfort is a key issue and these guidelines may be helpful.
Users Height:
5’ 6” and under = shortest crank settings 5’ 7” to 5’10” = middle crank settings 5’ 11” and taller = longest crank setting
Important Note: When using this product for medical or rehabilitation purpose, the crank radius, seat height and distance should be set by the attending therapist or medical
professional based on the specic needs of the user.
CAUTION
Always follow medical professionals guidelines to reduce the risk of personal injury. Failure to follow their directions may result in injury to yourself.
17
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
ADJUSTMENTS
Control Console Adjustment
The control console should be positioned so it is eye level or in direct line of sight of the user. The control console can be repositioned by pushing backwards or pulling forward.
Crank Arm Adjustment
Crank arms can be adjusted to accomodate user height, achieve proper bio-mechanical positioning and work different muscle groups.
To adjust crank arm position, pull yellow spring loaded locking pin out and move crank arm to new position.
Foot Crank Adjustment
Foot crank pedals can be adjusted to accomodate user height, achieve proper bio-mechanical positioning and work different muscle groups.
To adjust foot crank position, pull yellow spring loaded locking pin out and move foot crank to new position.
Reversing Crank Arms
The upper body crank arms can be easily adjusted to work in unison or in a rotary rowing motion. To take advantage of this feature, first remove the Allen head screw and washer from the steel crank rods on the right side of the unit. The allen keys and instructions are included in your owners package. This is done one time only. To reverse the crank, and slide the crank arm completely out of the Crank hub. Pull the yellow pin and re-insert the crank arm carefully in the opposite position. The crank arms will now be working in unison. It is important to know that the function can not work in conjunction with the lower body movement on the PRO2.
Using your SCIFIT PRO2 or PRO1000 in this manner encourages abdominal and back involvement and can be used to in the treatment of specific medical conditions.
pull the yellow pin
18
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
ADJUSTMENTS
Swivel Seat Adjustments
Horizontal Adjustment - The seat can be adjusted in
1” increments and is held in place with a spring loaded adjustment pin. The seat system is easily adjusted by pulling up on the T-handle yellow knob and sliding the seat assembly forward or back.
The seat may also be adjusted forward or back by pressing on the Foot assist pedal.
Adjust the seat so the arms have a slight bend at full extension. The feet can be located in the most comfortable area on the flat surface of the foot rest.
Vertical Adjustment - Pull up on the yellow paddle shaped handle to raise or lower the seat. NOTE: No weight should be on the seat when raising.
Swivel Adjustment - Push down on the yellow paddle shaped handle to rotate the seat. The seat will lock into place at each 90 degree position.
Pull handle up to raise or lower seat
Push handle down to rotate seat
Pull T-Handle up to move seat forward and back
Press Foot pedal to move seat forward and back
19
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
ACCESSORIES
12V Power Pack - #P1562 (Dom.) #P3733 (Int’l)
To provide continuous power to the display when equipment is not in operation, plug in the 12V power pack into the jack located on the lower front side of monocoque frame.
Low Support Boot - #A3248 (Optional)
Footplate with a lip at the back to keep the feet from
sliding off the pedal. Open at the front and has Vel­cro straps to keep the feet in place. They come with
the crank bars for easy installation and removal.
Order online 24/ 7 at w ww .SCI FI T.com
Tie Downs - #P2506 (Optional)
The tie downs are adjustable straps with clips on each end. They fix to the wheelchair on the PRO1, PRO1000 or PRO2 at the front cross tube. The footrest must be removed to expose the tie down anchors.
High Support Boots - #A2242 (Optional)
A plastic calf high boot which is open at the front and has Velcro straps to keep the legs in place. They come with the crank bars for easy installation and removal.
20
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
ACCESSORIES
Glove Assist - #P3981 (OPTIONAL)
For individuals tha have limited strength with fingers and wrist, the Assist Gloves are available. Fit hand into glove, wrap glove pad with fingers around crank handles and secure in place with velcro strips.
Order Online 24/7 at www.SCIFIT.com
21
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
HEART RATE TRANSMITTER STRAP
Uses of the Heart Rate Transmitter Strap
The optional wireless heart rate transmitter accessory is a useful device if you desire continuous feedback on your current heart rate during a workout. In addition, the PRO2 and PRO1000 includes a Heart Rate Control program which requires use of the strap.
The Heart Rate Control program enables the user to set­up a target heart rate. Through real-time monitoring of the user’s heart rate, the computer maintains the user’s heart rate at or below this established target rate by decreasing the workload if the user’s heart rate exceeds the target.
Activating & Deactivating Transmitter
Heart Rate Transmitter Straps come in a variety of styles and manufacturers. To properly activate, secure strap to the chest, and to deactivate follow the instructions that come with the Transmitter Strap.
CAUTION
Always follow manufacturers instructions for proper care and use. Failure to follow manufacturers instructions may result in injury to yourself.
Calculating Target Heart Rate Zone
Your approximate Maximum Heart Rate (MHR) is equal to 220 minus your age. The upper limit of your target zone is equal to 0.85 times your MHR. The lower limit of your target zone is equal to 0.60 times your MHR.
For Example: Your age is 40: 220 - 40 = 180 180 x .85 = 153 (max MHR) 180 x .65 = 108 (min MHR)
These values are based upon averages, always consult your physician to establish the proper Heart Rate Zone for your individual health condition.
WARNING
Heart Rate monitoring systems may be inaccurate. If you feel faint, stop exercising immediately. Over exercising may result in serious injury or death.
22
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
Programs
SCIFIT products have 200 levels of computer controlled resistance, which ensures that users of all fitness levels will be able to get a challenging but not overwhelming workout. Because the resistance is adjustable in .1 increments, it is easy for the user to track progress. SCIFIT products feature one of the highest resistance capabilities available on any cardio equipment.
Time 15:00
Level 1.0
Weight 150
SCIFIT products are self generated and have an extremely low starting resistance. One pedal movement or crank revolution activates the console and the screen will remain lit at the most minimal levels of movement.
SCIFIT products have a battery back up which will keep the screen lit for a short period after exercise or if the user stops. This varies between 0 seconds and 5 minutes and can change with the amount of use each product gets.
If you after use, an optional wall pack can be plugged in to accomplish this. This is common in medical settings and with Fit-Key Programs.
prefer the console to remain lit before and
Manual Workout
Allows the user to set the intensity at any level. This level will not change unless the user manually increases or decreases the intensity using the [UP] or [DOWN] arrow keys.
Adjust level intensity with the
keys, then press
Time 15:00
Level 1.0
Weight 150
Enter user weight with the keys,
then press and begin exercise.
Fit Quik
Press Then
MANUAL
Time 15:00
Level 1.0 Weight 150
Adjust workout time with the keys,
then press
Allows the user to select a two stage program of cardiovascular work with ISO-strength (Isokinetic) work loads and duration determined within the factory set up.
Press Then
Fit-Quik
23
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
Fit-Quik Cont’d
The categories displayed will depend on the workout that is selected in the factory setting. The following will be seen for the workout choosen.
Manual or Hills
Level 1
Weight 150
Adjust the Level and Weight with the
keys, then press
Constant Workout
Weight 150
Constant Work
Pedal resistance is automatically adjusted to compensate for any change in pedal speed (RPM), thus workload (Watts) will remain constant at any given setting.
Press Then
Time 15:00
Watts 20 Weight 150
Adjust workout time with the
keys, then press
CONSTANT WORK
Adjust the Weight with the
keys, then press
Time 15:00
Watts 20
Weight 150
Adjust target watts with the
keys, then press
Time 15:00
Watts 20
Weight 150
Enter the user weight with the
keys, then press and begin exercise
24
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
ISO-Strength Program
ISO-Strength is a isokenitic program, meaning that the unit will resist your movements in order to force you to stay at a set speed. This type of strength workout will not cause excessive soreness because
it is accommodating. The computer will adjust
resistance to keep the user at the target RPM speed.
Time 15:00
RPM 35
Weight 150
Enter user weight with the keys,
Press Then
ISO-STRENGTH
Time 15:00
RPM 35
Weight 150
Adjust workout time with the
keys, then press
Time 15:00
RPM 35
Weight 150
then press and begin exercise
Hills Program
Allows the user to select from seven different Hill profiles at various pre-programmed intensities. The following profiles are available: Hill Course, Sprints, Twin Peaks, Peak, Progressive, Multi-Peaks and Ramp.
Press Then
Prole Course
Time 15:00 Level 1.0
HILLS
Adjust target RPM with the keys,
then press
Select 1 of 7 profiles with the
keys, then press
25
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
Hills Cont’d
Prole Course
Time 15:00
Level 1.0
Adjust workout time with the
keys, then press
Prole Course
Time 15:00
Level 1.0
MORE
Pressing this key will enter the user into the 2nd of three workout program selection screens. This screen will show an additional five more pre-programmed workout profiles.
Press
A new screen will appear with additional programs: Heart Rate, Stess Test, Random, Power Fit and Heart Fit.
MORE
Heart Rate Program
The Heart Rate Transmitter Strap is required for this program. Refer to page 22 for a complete
instruction on using the strap and to understand
how to calculate your Target Heart Rate.
Put on Heart Rate Transmitter Strap
Adjust level intensity with the
keys, then press
Time 15:00
Level 1.0
Weight 150
Enter user weight with the keys,
then press and begin exercise
Press Then
HEART RATE
Time 15:00
Heart Rate 120 Weight Rate 150
Adjust the workout time with the
keys, then press
26
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
Heart rate Cont’d
PROGRAM INSTRUCTIONS
Time 15:00
Heart Rate 120
Weight 150
Adjust the target Heart Rate with the
keys, then press
Time 15:00
Heart Rate 120
Weight 150
Enter the user weight with the
keys, then press and begin exercise
First Target 50
Increment 5
Interval 5:00
Select wattage increments after each interval with
the keys, then press
First Target 50 Increment 5
Interval 5:00
Select the length of each interval with the
keys, then press
Stress Test
A designed step test to be used as training program or use with other diagnostic devices (if appropriate). The user sets a target wattage with timed intervals and preset wattage increments.
First Target 50
Increment 5
Interval 5:00
Weight 150
Enter user weight with the
keys, then press and begin exercise
Increment 5 Interval 5:00
Select target wattage with the
keys, then press
27
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
Random Program
The Intelli-Fit console will randomly display different workout profiles each with its own level of difficulty. The operator only has to choose the type of the profile, then select the time length of the workout and the level difficulty.
Note: The highest column of the profile represents the workout level you selected. Columns below it are percentages of the level selected.
Prole Random
Time 15:00
Level 1.0
Adjust level intensity with the
keys, then press
Press Then
RANDOM
Prole Random
Time 15:00 Level 1.0
Select a random profiles with the
keys, then press
Prole Random
Time 15:00
Level 1.0
Time 15:00
Level 1.0
Weight 150
Enter user weight with the keys,
then press and begin exercise
Adjust workout time with the
keys, then press
28
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
Power Fit Programs
This key displays two options “Test” and “Training”. These programs are power and strength indicators for the user.
Press and the screen will display
a choice of “Test” or “Training” as shown below.
Power Fit
Power Fit
Test
Training
More
Training
Specifically designed preset wattage training programs based off user Power Fit test evaluation.
Three programs and four levels (Beginner, Intermediate, Advanced and Sport Performance) are available.
Press Then
Program 1
Level Beginner Weight 150
Select 1 of 3 programs with the
keys, then press
TRAINING
Test
This program is based on a pre-programmed wourkout designed to evaluate your “Power Drop %”, which gives a fitness indication of power and strength using wattage as the main measurement.
Press Then
and begin exercise
TEST
Program 1
Level Beginner
Weight 150
Select 1 of 4 levels with the keys,
then press
Program 1
Level Beginner
Weight 150
Enter user weight with the keys,
then press and begin exercise
29
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
Heart Fit Programs (Use Chest Strap)
This key displays two options “Test” and “Training”. These programs are Heart Rate recovery indicators for the user.
Press and the screen will display
a choice of “Test” or “Training” as shown below.
Heart Fit
Heart Fit
Test
Training
More
Level Beginner
Weight 150
En t er user w eight with the k eys,
then press and begin ex ercise
Training
Designed training programs based on the user’s evaluated Heart Fit test. A training schedule with retesting is recommended. The user has three programs and four levels: Beginner, Intermediate, Advanced and Sports Performance to choose from.
Press Then
TRAINING
Test
This program is based on a pre-programmed workout designed to evaluate your Heart Rate recovery. The user can select from 1 to 4 levels: Beginner, Intermediate, Advanced and Sports Performance.
Press Then
Level Beginner
Weight 150
Sel ect 1 of 4 lev els w i t h the keys,
then press
TEST
Level Beginner
Program 1 Weight 150
Sel ect 1 of 4 lev el w ith th e k eys,
then press
Level Beginner
Program 1
Weight 150
Sel ect 1 of 3 prog r am s w ith the
keys, th en press
30
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
Training Cont’d
Level Beginner
Program 1
Weight 150
En t er user w eight with the keys,
then press and begin ex ercise
Additional Key Features
SCIFIT has also included extra user friendly key features the user may use during a workout.
CHANGE
Allows the user to change the viewing fomat of the workout profile and data displayed on the LCD screen during the workout.
VIE
W
If at anytime the user may want to pause during a workout, this may done by pressing the [Pause/Clear] key. The screen workout will then minimize and provide the user three options
1. Continue - Maximizes the workout screen and continues the workout where the user had stopped.
2. Change - Returns to a sub-menu where information may changed that was previously entered by the user.
3. Stop - Exits the workout and returns to the main menu.
Note: The console will reset to the main menu after a short period of time if no selection is made.
FAN
The console contains two 3-speed cooling fans that can be activated by the user at anytime.
Power Burst
When activated a count down will display on the screen for the user to prepare to pedal faster for a small duration of time. This time duration can be increased or decreased in the “User Set-up”.
31
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
MAI NTENANCE & SERVI CE
Maintenance
The PRO is virtually maintenance free. After training, always wipe down your SCIFIT exercise product. Perspiration that continuously settles on the frame, upholstery, casings, and control console may eventually cause rust or damage. Damage resulting from lack of maintenance is not covered under warranty.
If defective components are identified an
d require replacement, the equipment should be put out of service until repaired.
CAUTION
I
n order to maintain a safe level of operation equipment must be inspected on a routine bas is for damaged or worn parts may result in injury to yourself or others.
PRO2/PRO1000 Maintenance Schedule
Any mechanical or electrical work conducted within the main body of a medical CE class IIa unit MUST be recalibrated. The generic maintenance schedule below should be applied to medical CE and non-medical CE products
COMPONENT USE WHEN BY WHOM
Covers, Seat,Handlebars Damp Cloth Daily Club Maintenance
and Console
. F
ailure to inspect equipment
UNITED STATES CUSTOMER SERVICE
For assistance in the service of SCIFIT products;
phone : (800) 745-1373 or (918) 359-2040 fax : (918) 359-2045 e-mail:
service@scifit.com
The Product Support department is staffed from 7:00 AM to 6:00 PM CST Monday through Friday. A voice mail service is available 24 hours a day for
recording messages to request technical support and to order replacement parts. Our mailing address is:
SCIFIT Systems Inc.
,
5151 S. 110th E. Ave. Tulsa, OK 74146 USA
UK & EUROPEAN CUSTOMER SERVICE
phone : +44 1344 300022
fax: +44 1344 868838 e-mail: inf
o@scifit.uk.com
SCIFIT LTD (UK)
Lexham House Forest Road Bin
eld
Berkshire, RG42 4HP UK
LCD Screen LCD TV Screen Weekly Club Maintenance soft cleaning cloth
Chains Lightly Applied Monthly Club Maintenance
Chain Lubricant
Company Number: 5970624 (UK)
*COUNTRIES OUTSIDE OF UK & EUROPE
Nuts and Bolts Tighten When Bimonthly Club Maintenance neccessary
Base Roller Guide Track Damp Cloth Monthly Club Maintenance
PLEASE USE USA CONTACT NUMBERS*
Ord er onli n e 24/ 7 at w w w .S C IFIT.co m
32
SCIFIT • Scientific S olutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCI FI T
WARRANTY
t is very im portant that your
I
online
http://www.SCIFIT.com/warrantyregistration.shtml
at
S CIF IT
mac h ine is regis tere d
regis tration fo r m at the back of this manual
SCIFIT Statement of Warranty
SC IFIT
normal and proper use subject to the following limitations
warranties new products against defective workmanship and/or materials under
a
) S C IFIT’s
(
ithin the United States and Canada both parts and the cost of labor required to
W
replace or repair a defective product for a period of one
purchase date as been retur
for a period of two replacement parts or products with any labor costs associated with such replacement or repair to be at Buyer’s expense components outside this policy clause
O
labor for a period of three
*
warranty card and if warranty
shipment from factory
obligation to the original purchaser shall apply to
documented by *warranty card and if warranty card has not
ned by user/dealer, then date of shipment from the factory. T
years, such obligation shall extend only to the supply of
(2)
.
utside the United States and Canada replace defective product with no
(3)
years from user purchase date as documented by
card
has not been returned by user then date of
.
*N
ote
riginal purchaser must register their purchased products either by
: O
warranty card return, web site registration or fax to activate warranty period or shipment date is extant for start of warranty period be given for warranty registration to allow stock rotation and showroom stock thereafter none registration will be shipment date for the start of the warranty period
.
his c a n be done
. T
fill out and mail the
or
.
:
:
(1)
year from
. R
efer to clause (e) for
. A
ninety
(90)
user/dealer
hereafter
day period is to
,
(
(
b
) S C IFIT’s
o allowance shall be granted for repairs made by Buyer without
N
written approval discretion
c
) S C IFIT’s
to normal and abnormal wear and tear, improper use, corrosion (perspiration improper maintenance, improper installation, improper rated, grounded or dedicated electr part of the product has been altered from its original state by Buyer or a third party
.
obligation shall be limited to repairing or replacing defective parts
. The
.
warranty does not apply to parts requiring replacement or repair due
ical
decision to replace or repair shall be solely at
circuits or improper storage, nor does it apply where all or
(d) THIS WARR A NTY IS IN LIEU OF ALL OTHE R WARR ANTIES,
EX P R E S S E D OR IMP L IED, ARISING B Y LA W OR OTHE R WIS E INC L UDING WARR A NTY OR ME RC HANTA B IL ITY OF FITNES S FOR P A RTICUL A R PURP OS E, AND IS IN LIEU OF AL L OTHER LIAB ILITIE S OF SC IFIT INC L UDING DIREC T, INDIRE C T, S P EC IA L AND C ONSE Q UE NTIAL DA MA G E S OR PE NAL TIE S EXP RE S S E D OR IMPL IED WHETHER ARIS ING OUT OF C ONTRA C T, NEG L IGENC E OR OTHER S OR T.
33
Solutions for Fi
SCIFIT • Scientific
SCIFIT SCIFIT SCIFIT
Solutions for Fi
tness • SCIFIT • Scientific
SCIFIT’s
SCIF IT’s
tness •
prior
.
),
SCI FI T
WARRANTY
SCIFIT STATEMENT OF WARRANTY
(e) The
determined to be defective
T
rea d mills
readmill belts
T
readmill belts decks
T
T
readmill structure
T
readmill drive system inclusive of
motor
T
readmill Handrails
readmill Heart rate grips
T
T
readmill water bottle holders
readmill trays
T
U
pholstery
S
addles/Seats
Rotary Pedals 12 months
ubber grips
R
eart rate grips
H R
otary structure
R
ubber footPads
otary water bottle holders
R
otary trays
R
below listed items have the following warranty coverage unless
. T
hes e items include, but are not limited to
– AC 5000
only
&
inverter
90
R
otary Produc ts
models
&
frame
& H
andles
12
W
12
W
arranty Period
12 12
5
3
90
arranty Period
12
months months
years
5
years
years
months
days
days
months months
& F
rame
(BioF
) 12
lex
12
12
5
90
90
months
months
years
months
days
days
:
A
c c es s ories
edal straps
P
H
eart Rate Receiver/Transmitter
Low
support boots
H
igh support boots ssist gloves
A USB K
(f) F
eys and Lanyards
ires, floods, and acts of God,are not covered under this warranty
P
roduc ts
N
W
arranty Period
ormal wear
90
12
12
90
90
&
days
months months
days days
tear
.
34
SCIFIT • Scientific S olutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCI FI T
WARRANTY
reight and Shipping
F
s e r u d e c o r
3 . 2 1
P
e c
SC IFIT
during transit or installation part for shipping damage at time of delivery or installation, and prior to signing receiving paperwork appropriate transit company
is not respons ible for the repair or replacement of any unit or part damaged
customer is responsible for inspection of each unit and
If the customer signs an unqualified reciept for freight or
.
. The
. The
customer is responsible for pursuing all freight damage claims with the
damage goods, the customer is solely responsible for the cost of the repair or replacement for such freight damage.
M
aintenance
After training, always wipe down your S C IFIT exercise product.
erspiration that continuous ly settles on frame, uphols tery, cas
P
ings
and control panels may eventually cause rust or damage.
D
amage resulting from lack of maintenance will NOT be covered under warranty. To clean uphols tery, use mild soap and warm water. Dry with a clean towel. Refer to the Treadmill maintenance schedule.
P
roduct Support
ssistance for the service of
A
or fax
C
for
O
our
SCIFIT • Scientific S olutions for Fitness • SCIFIT • Scientific Solutions for Fitness •
(918) 359-2045.
entral Time Monday
recording messages to
ur goal is to return every
normal business hours
lease have the following information prior to calling technical support
P
M S P D
odel number of equipment erial number of equipment oint of contact name and phone number etailed des cription of symptoms encountered
SCIFIT
The
product support department is staffed from
through Friday
request technical support and to order replacement parts
voicemail call within
.
SCIFIT SCIFIT SCIFIT
products is available by calling
voicemail service is available
. A
minutes of when it is placed during
30
.
35
(800) 745-1373
7 AM to 5 PM
hours daily
24
:
.
SCI FI T
WARRANTY
I
nstallation
SC IFIT
during installation damage at the time of installation claims with the installer
I
f an order includes software, such computer software is transferred by customer pursuant to a single user license, the royalty, term set forth on or in the package accompanying such software
K
eyMaster software will receive
eligible for product upgrades for one year following purchase
SC IFIT T
hes e names must not be used by other entities in the fitness busines s
SC IFIT
copied without prior approval fro
is not responsible for the repair or replacement of any unit or part damaged
. The
customer is responsible for inspection of each unit and part for
. The
.
S
oftware
has trademarked several names to uniquely identify its busines s and products
decals,user’s manuals, and service manuals are copyrighted and may not be
, T
rademarks
1
m
year of call-in technical support and owners will be
SCIF IT.
customer is responsible for pursuing all damage
, C
opyrights, and Patents
SCIFIT to
,
s
and conditions of that are
.
.
.
the
.
SC IFIT
products features
D D
next day delivery requiremen overnight or 2nd day parts shipping, at customer’s expense charge the customer’s ground shipment and overnight or 2nd day
has obtained several patents on features and des igns that are unique to its
. SC IFIT
and des igns in other products
uring the first etermination must be made before
ts
will defend these patents against those who attempt to utilize these
.
P
arts Shipment
30
days warranty parts will be shipped via overnight delivery
2:00 PM C
. D
uring the remainder of the first year warranty period
will be filled via ground shipment
UP S
account,or
COD
. The
the difference in freight cost between
.
36
.
entral Time on any given weekday for
,
customer is welcome to request
. If
requested
parts
, SC IFIT
will
SCIFIT • Scientific S olutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCI FI T
SCIFIT SCIFIT SCIFIT
WARRANTY
R
eturn of Parts
SC IFIT
meet this commitment, the rapid return of defective parts is essential of the parts by our engineering department leads to changes that insure the same problem does not re-occur
W
within the parts invoice net
is committed to continual improvement in the equipment we market
. T
hank you in advance for your assistance
hen requested by
20
days of receipt of replacement part
SCIFIT,
30
days
defective parts must be returned to the
. O
ther
wise
SCIF IT
.
. In
order to
. The
examination
!
SCIF IT
will expect payment on
factory
Please follow these three easy steps for returning parts.
S
tep
1
K
eep the box and packing material in which the new parts arrived
S
2
tep
W
rap the defective part and place in the box for safe return
moment needed to fill in the return parts form that is enclosed in the box with the new
.
parts
S
3
tep
A UP S
returned be will
prepaid Retu rn Label will be in the part box for only those parts that need to be
. W
iss ued for the original parts invoice
NOT be
ALL of
hen
paid until defective parts are returned to the factory
the parts are received and inspected at the factory, a credit will
. A
ttention s ervice companies
. P
.
lease take the brief
-
labor invoices
.
S
ervice Labor
W
here applicable, the
technician to provide field support
48
busines s hours
soon as repair parts are available to the field service technician will be supplied in advance of the field service technicians so that the product is repaired with one call
A
ll purchased parts will carry a
installation for more details
T
his Limited Commercial Warranty supercedes the limited commercial warranty printed
I
f you have questions or require additional information, please contact
.
in the
“U
SCIFIT
(8
hours per busines s day) following notification of a problem or as
product support personnel will arrange a local field service
. E
very effort will be made to schedule service during
P
urchased Parts
12
month
warranty
.
sers Operation Manual” for all
Inc. at 1-800-745-1373 or
. W
here possible, parts
. R
efer to Purchased parts shipments and
SCIF IT S
ystems
, Inc.
products
.
SCIF IT S
service@scifit.com
ystems
37
,
SCI FI T
SCIFIT • Scientific S olutions for Fitness • SCIFIT • Scientific Solutions for Fitness •
R
SCIFIT
Warranty Card
SCIFIT SCIFIT SCIFIT SCIFIT
or complete this form, fold it and return it to SCIFIT. We request
Register online at
http
://
you send this card within 2 weeks after your equipment has been delivered to insure proper warranty registration.
Company Name
Contact Name
Address
City/State/Zip
www
.SC IFIT.
com/warrantyregistration.shtml
Email Address
Home Phone (____) Business Phone (_____)
Model Purchased
Date Received Serial Number
Entity Purchased From
City/State
Please rank the following reasons (1 through 6) for selecting SCIFIT with 1 being most important:
____Features____Quality____Price____Dealer___User Friendly___Appearance
Please Check the appropriate box(s) on how you were introduced to SCIFIT:
Saw in ______________________ Magazine
Saw at ____________________ Tradeshow
Other
Comment
Introduced by SCIFIT Dealer
Referred by SCIFIT User
W
arranty
C
ard
Thank You For Choosing
Scientific Solutions For Fitness
TM
www.SCIFIT.com
P2278 Rev. B
Tulsa, OK 74146
SCIFIT
5151 South 110th East Avenue
______________________________ ______________________________ From _________________________
Important: Please keep this page for “Recalibration records”
Model Number:
Serial Number:
Date of Purchase:
Calibration Date (Medical units):
Supplied By: SCIFIT Systems Inc.
User Manual: #P4728A (11/2010)
1st Recalibration
2nd Recalibration
3rd Recalibration
4th Recalibration
5th Recalibration
DATE
CLUB OR CERTIFICATION LOCATION
CERTIFIED SERVICE COMPANY
TECH INITIALS
Please make extra blank chart copies for future use
5151 South 110th East Avenue
Tulsa, Oklahoma 74146
USA
Sales: 1-800-278-3933 • 1-918-359-2000
Customer Service: 1-800-745-1373
Order online 24/ 7 at w ww .SCI FI T.com
Loading...