SCIFIT ISO1000, ISO7000 User's Operation Manual

Users’ Operations Manual
ISO1000 & ISO7000
Before using this product, read this manual and follow all safety rules and operating instructions.
Upright Bike
This page purposely left blank
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
SAFE TY INF ORMATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
INTRODUC TION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
SPEC IFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
SETUP & INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRODUCT OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
KEYPAD FUNCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
BIOMECHANICAL POSITIONING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
ADJUS TME NTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ACCESSOR IE S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
HE ART RATE TR ANS MITTE R STRAP & CONTAC T GRIPS . . . . . . . . . . . .10
PROGRAM INSTRUC TIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 - 19
MAINTENANC E & SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
. . . . . . . . . . 4
. . . . . . . . . . 8
WARRA N
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
TY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 - 25
Order on line 24/ 7 at w w w .SCIF IT.com
SAFETY I NFORMATI ON
T
he purpos e of safety symbols is to attract your attention to pos s ible dangers and their explainations, deserve your careful attention and understanding thems elve s, elimina te any danger or warnings they give are not subs titutes for proper accident prevention meas ures
ook for thes e symbols to point out important safety
L
precautions involved
. IT MEANS ATTENTION! Y
.
. The
. The
safety warnings do not, by
.
safety symbols
. The
ins tructions
our safety is
WARNING
F
ailure to obey a safety warning
to yourself and others precautions to reduce the ris k of pers onal injury.
. A
lways follow the safety
can
result in injury
CAUTION
F
ailure to obey a safety caution
to yours elf and others. Alwa ys follow the sa fety precautions to reduce the ris k of pers onal injury.
can
result in injury
,
R ea d all instructions before using your S CIF IT
exercis e machine. S ave these ins tructions for future reference
los e supervision is necessary when exercise machine
C
is being us ed by, or nea r children, or individua ls with disabilities . Keep children away from extended ha nd and foot supports.
U
se the exercis e ma chine only for its intended use as described in this manual. Do not use attachments not recommende d by the ma nufa cturer.
N
ever drop or insert any object into any opening.
o not use outdoors or in a harsh environment where
D
water is present (i.e. pool or spa area s
.
).
SCIFIT • Scientific S olutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFI T
1
I NTRODUCTI ON
Thank you for your purchase of the SCIFI T I SO1000 or I SO7000 Adjustable Position Upright Bike. We have incorporated the
finest technology and ergonomic
design into this machine to assist you in achieving your
fitness
goals. However, for your safety, please adhere to the following recommendations before you begin to exercise.
The SCIFI T ISO1000 & I SO7000 are designed for Class “S” (Studio), Class “I (Medical Device Directive) applications. The intended uses are for Cardio & Pulmonary R ehabilitation as well as Sports Medicine, Physical Therapy, Physical Conditioning and Strength Training. SCI FIT equipment is suitable for placement in sports performance and recreational facilities. T he I SO1000 & I SO7000 have 200 levels of computer controlled
fitness
overwhelming workout.
Consult Your Physician
Consult your physician or medical specialist before participating in any exercise program, especially if you are pregnant, or if you are suffering from: heart disease, respiratory disease, diabetes, hypertension, high blood pressure, elevated cholesterol, arthri any other diseases or physical complaints.
Adult Usage
SCIFI T equipment is designed and intended for adult usage and children of appropriate ages while being supervised. Young children should be kept a safe distance away from equipment.
Cool Dow n
To prevent muscle injuries and soreness, you should always cool down ( at least 5 minutes) by doing a series of stretches after each workout.
resistance, which ensures that users of all
levels will be able to get a challenging but not
” (Special Needs) and Class “I I a”
fitness,
medical rehab,
tis, or
CAUTION
Always stretch a fter a workout s ession to reduce
the risk of pe rs ona l injury. Failure to stretch properly m ay result in injury to youers elf
.
Guidelines for Healt hy Adults
The American College of Sports Medicine (ACSM) and the American Heart Association ( AHA) are continuously updating guidelines and recommendations for physical activity.
The current basic recommendations from ACSM and AHA is:
Do moderately intense cardio 30 minutes a day, days a week. OR Do vigorously intense cardio 20 minutes a day, three days a week. AND Do eight to twelve repetitions of each exercise twice a week.
Moderate-intensity physical activity means working hard enough to raise your heart rate and break a
I t should be noted that to lose weight or maintain weight loss, 60 to 90 minutes of physical activity may be necessary. T he 30 minute recommendation is for the average healthy adult to maintain health and reduce the risk for chronic disease.
To review the latest guidelines and recommendations,
ten strength-training exercises, eight to
ve
www.acsm.org
WARNING
top exercis ing immediately if you fee l nausea
S
dizzine ss, sharp pa in, or any other physica l discomfort. Failure to stop excercising c an res ult in injury or death to yourself
Train Intelligently
To ensure a future of good health, you should always eat well balanced meals, drink plenty of
Always follow training guidelines that are your own physical condition.
.
fluid/water
yats dna ,tuokrow a gnirud
specific to
,
WARNING
Injuries to health may res ult from incorrect or
exce s sive tra ining. F ailure to stop excercis ing can
in injury or death to yourself.
result
.noitasrevnoc a no yrrac ot elba gnieb llits tey ,taews
:etisbew enicideM stropS fo egelloC naciremA eht tisiv
.yltnegilletni gnisicrexe yb t
SCIFIT • Scientific
Solutions for Fi
2
tness • SCIFIT • Scientific
Solutions for Fi
tness •
SCI FIT
SPECI FICATIONS
Weight . . . . . . . . . I S O1 0 0 0 - 170 lbs. / 77 Kg. . . . . . . . . . . . I SO7000 - 178 lbs. / 81 Kg.
Max User Weight . . 350 lbs. / 159 Kg.
Power . . . . . . . . . . Self generating w/auto recharge battery back-up.
Optio nal Low Vo lta ge AC ada pte r ava ilable. Resistance System . I S O1 000 - Electromagnetic Self Generating R esistance . . .I S O7000 - Bidirectional Programs . .
Accuracy Class. . . . . Class A
Warranty . . . . . . . . Within U.S. & Canada 3 years parts, 1 year labor
Outside U.S. 3 years parts, no labor
. . . . . .
Manual, Fit Quik, Constant Workout, ISO-Strength, 7 Pre-programmed Hills proles, Heart Rate, Power Fit test, Power Fit training, Heart Fit Test, Heart Fit Training, Stess Test and Random.
58”
1473 mm
19. 5”
495 mm
56. 5”
1435 mm
24”
610 mm
SCIFIT • Scientific
Solutions for Fi
3
tness • SCIFIT • Scientific
Solutions for Fi
tness •
SCI FIT
SETUP & I NSTALLATI ON
P lace m ent of Cardiov a s cular Ma chine Position the unit in a location that has a stable and level sub-oo in a location that is not in direct sunlight, in areas of extreme temperature and humidity, or where the equipment may be splashed with water or
This machine is intended for indoor use only.
fluids.
r. E quipment should be positioned
Endcap
40” / 1 Meter
Safety Space
Endcap
Equipment should be posistione perimeter of 40” or 1 meter around the unit
d with a safety
WARNING
F
ailure to place the equipment on a stable and level
sub-floor with a safety perimeter can result in injury to yourself and others.
Leve l C a r diovas cu lar Machine If the sub-oor is unle leveling end caps. T he end caps are designed with the recess of end cap off centered. This allows you to rotate the endcap(s) to a position that will level the equipment. After adjustment, check and make sure end caps are fully seated against base frame tubes.
Offset Endcap
vel, the unit is equipped with
40” / 1 Meter
Safety Space
Endcap
40” / 1 Meter
Safety Space
Endcap
SCIFIT • Scientific
Solutions for Fi
P rop er S up ervi s ion Close supervision is required when the exercise machine is being used by or near individuals with disabilities. Keep unsupervised children outside the safety perimeter.
Cle a nin g Never clean the machine with orga ,stnevlos cin alcohol or bleach based cleaners. To promote a healthy environment, wipe any sweat off of unit with a commercially manufactured wipe designed for the
finess industr
y, or a damp cloth.
4
tness • SCIFIT • Scientific
40” / 1 Meter
Safety Space
Solutions for Fi
tness •
SCI FIT
Oversized
Gel Seat
PRODUCT OVERVIEW
Custom Molded
Hand Grips
Heart Rate
Contact Grips
Intelli-Fit Console With Bottle Holder
Dual Fit-Key™ and MP3 Charger USB Receptacles
Vertical Seat
Adjustment
Horizontal Clamp Seat
Adjustment
Leveling Base
Endcaps
Foot Crank
Transport Wheels
SCIFIT • Scientific
Solutions for Fi
5
tness • SCIFIT • Scientific
Solutions for Fi
tness •
SCI FIT
Work Level Status LCD Screen -
The Work Level Status L C D Screen gives a progressive real-time indication of the current work level of any and all programs
KEYPAD FUNCTI ONS
Select Workout or Insert Fitkey
Copyright c 1998-2010. SCFIT Systems, Inc.
Press to start or choose a program
PAUSE/CLEAR - The [Pause/Clear] key will pause the workout. Pressing
[Pause/Clear] a second time when in the pause mode will stop the workout and return to the main screen.
To restart in the paused mode press the[Quick Start] key.
Manual
ENTER -
The E nter Key is pressed to enter selected values for the workout parameters.
Hills
QUICK START
“Quick Start” into the Manual mode, or after logging into a program.The Quick Start key will activate the selected program.
Random Heart Rate
- This key provides a one-touch
Iso-Strength
More
Profile Selection Area -
Allows the user option to choose from 12 different workout profiles
Up Arow and Down Arrow - These keys increase or decrease values of the workout parameters.
SCIFIT • Scientific
Solutions for Fi
6
tness • SCIFIT • Scientific
Solutions for Fi
tness •
SCI FIT
BIOMECHANI CAL POSI TI ONI NG
Body Positioning
Comfort is a key issue to obtain the most exercise, and a upright body posture will result in a broader range of muscle recruitment.
Seat Height
The seat height should be positiioned so that the legs are not hyperextended, and have a slight bend in the knee when at the bottom of the pedal stroke.
Fore- Aft Seat Position
The Fore-A are behind the pedal crank, and your body is in a balanced state. You should be able to stay in balance without gripping the handlebar. Moving the seat forward or backwards will change the relationship of the seat height, so readjustment of seat height may be necessary.
ft position should be set so that your hips
beneficial
Gripping t he Handlebar
Position the seat so that your grip on the handlebar is light and comfortable. The SCIFI T bike has a handlebar that allows several gripping positions. Moving hand positions during a workout will help reduce stress points and upper body tension.
Import ant Note: When using this product for medical or rehabilitation purpose, the program selection and work load should be set by the attending therapist or medical professional based on the the user.
specific
needs of
CAUTION
Alwa ys follow medical profes s iona ls guidelines to
reduce the ris k of personal injury. Failure to follow their directions m ay result in injury to yourse lf.
SCIFIT • Scientific
Solutions for Fi
7
tness • SCIFIT • Scientific
Solutions for Fi
tness •
SCI FIT
ADJUST MENTS
Order online 24 / 7 at w w w.SCI FI T.com
Seat Adjustment
The seat can be adjusted vertically and horizontally.
To adjust the vertical position - Pull the yellow knob of the spring loaded pin outward, move the seatpost to the desired hieght and release the knob so the post may lock in place.
To adjust the horizontal postion - R elease the seat slider clamp, so the seat slider may easily move forward or backwards. Position the slider in the desired location,
Horizontal
Adjustment Clamp
then set the clamp mechanism to lock the slider in place.
Vertical
Adjustment Pin
SCIFIT • Scientific
Solutions for Fi
8
tness • SCIFIT • Scientific
Solutions for Fi
tness •
SCI FIT
ACCESSORI ES
Order online 24 / 7 at w w w.SCI FI T.com
12V Wall pack - Dom (# P1562) I nt’l (# P373 3)
To provide continuos power to the display when the equipment is not in operation, plug in the 12V power pack into the power entry jack located at the lower rear left side of the machine.
Adjustable Crank Kit - # P43 13
The ISO1000/7000 upright bike may also be fitted with adjustable foot cranks to allow the pedals to be set at different comfortable distances for the operator.
Power Inlet Locat ion
SCIFIT • Scientific
Solutions for Fi
9
tness • SCIFIT • Scientific
Solutions for Fi
tness •
SCI FIT
HEART RATE TRANSMITTER STRAP & CONTACT GRI PS
Uses of t he Heart Rat e Transmitt er Strap
The optional wireless heart rate transmitter accessory is a useful device if you desire continuous feedback on your current heart rate during a workout. I n addition, the ISO1000 & ISO7000 include a Heart Rate Control program which requires use of the strap.
The Heart Rate Control program enables the user to up a target heart rate. Through real-time monitoring of the user’s heart rate, the computer maintains the user’s heart rate at or below this established target rate by decreasing the workload if the user’s heart rate exceeds the target.
Activating & Deact ivating Transmitter
Heart Rate Transmitter Straps come in a variety of styles and manufacturers. To properly activate, secure strap to the c that come with the Transmitter Strap.
hest and to deactivate follow the instructions
set-
CAUTION
Alwa ys follow manufacturers instructions for proper
care and us e. Failure to follow manufacturers ins tructions may result in injury to yourself
.
Use of the Heart Rate Contact Grips
For those models with contact heart rate grips, simply grip the contact pads lightly. After a short delay the pulse reading will appear on the display. I f a heart rate transmitter strap is worn, it will override the contact pickup.
The contact grips are not designed for use with SCI FI T’s Heart Rate Control program. This program requires a steady, continuous tel provided using contract heart rate grips.
While the contact grips provide a good barometer for monitoring the users heart rate, they are not recommended for medical where accuracy of monitoring is vital.
emetry signal which can not be
WARNING
eart R ate monitoring s ys tems may be inaccurate.
H I
f you feel faint, stop exerc ising immedia tely. Over
exercis ing may res ult in serious injury or death.
Heart Rate
Contact Grips
Calculating Target Heart Rate Zone
Your approximate M aximum Heart Rate (MHR) is equal to 220 minus your age. The upper limit of your target zone is equal to 0.85 times your MHR. T he lower limit of your target zone is equal to 0. 60 times your MHR.
For Example: Your age is 40: 220 - 40 = 180 180 x .85 = 153 (max MHR) 180 x .65 = 108 (min MHR )
These values are based upon averages, always consult
ur physician to establish the proper Heart Rate Zone
yo for your individual health condition.
SCIFIT • Scientific
Solutions for Fi
1 0
tness • SCIFIT • Scientific
Solutions for Fi
tness •
SCI FIT
PROGRAM INSTRUCTIONS
Programs
SCIFIT products have 200 levels of computer controlled resistance, which ensures that users of all fitness levels will be able to get a challenging but not overwhelming workout. Because the resistance is adjustable in .1 increments, it is easy for the user to track progress. SCIFIT products feature one of the highest resistance capabilities available on any cardio equipment.
Time 15:00
Level 1.0
Weight 150
SCIFIT products are self generated and have an extremely low starting resistance. One pedal movement or crank revolution activates the console and the screen will remain lit at the most minimal levels of movement.
SCIFIT products have a battery back up which will keep the screen lit for a short period after exercise or if the user stops. This varies between 0 seconds and 5 minutes and can change with the amount of use each product gets.
If you after use, an optional wall pack can be plugged in to accomplish this. This is common in medical settings and with Fit-Key Programs.
prefer the console to remain lit before and
Manual Workout
Allows the user to set the intensity at any level. This level will not change unless the user manually increases or decreases the intensity using the [UP] or [DOWN] arrow keys.
Adjust level intensity with the
keys, then press
Time 15:00
Level 1.0
Weight 150
Enter user weight with the keys,
then press and begin exercise.
Fit Quik
Press Then
MANUAL
Time 15:00
Level 1.0 Weight 150
Adjust workout time with the keys,
then press
Allows the user to select a two stage program of cardiovascular work with ISO-strength (Isokinetic) work loads and duration determined within the factory set up.
Press Then
Fit-Quik
11
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
Fit-Quik Cont’d
The categories displayed will depend on the workout that is selected in the factory setting. The following will be seen for the workout choosen.
Manual or Hills
Level 1
Weight 150
Adjust the Level and Weight with the
keys, then press
Constant Workout
Weight 150
Constant Work
Pedal resistance is automatically adjusted to compensate for any change in pedal speed (RPM), thus workload (Watts) will remain constant at any given setting.
Press Then
Time 15:00
Watts 20 Weight 150
Adjust workout time with the
keys, then press
CONSTANT WORK
Adjust the Weight with the
keys, then press
Time 15:00
Watts 20
Weight 150
Adjust target watts with the
keys, then press
Time 15:00
Watts 20
Weight 150
Enter the user weight with the
keys, then press and begin exercise
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
12
PROGRAM INSTRUCTIONS
ISO-Strength Program
ISO-Strength is a isokenitic program, meaning that the unit will resist your movements in order to force you to stay at a set speed. This type of strength workout will not cause excessive soreness because
it is accommodating. The computer will adjust
resistance to keep the user at the target RPM speed.
Time 15:00
RPM 35
Weight 150
Enter user weight with the keys,
Press Then
ISO-STRENGTH
Time 15:00
RPM 35
Weight 150
Adjust workout time with the
keys, then press
Time 15:00
RPM 35
Weight 150
then press and begin exercise
Hills Program
Allows the user to select from seven different Hill profiles at various pre-programmed intensities. The following profiles are available: Hill Course, Sprints, Twin Peaks, Peak, Progressive, Multi-Peaks and Ramp.
Press Then
Prole Course
Time 15:00 Level 1.0
HILLS
Adjust target RPM with the keys,
then press
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
Select 1 of 7 profiles with the
keys, then press
13
PROGRAM INSTRUCTIONS
Hills Cont’d
Prole Course
Time 15:00
Level 1.0
Adjust workout time with the
keys, then press
Prole Course
Time 15:00
Level 1.0
MORE
Pressing this key will enter the user into the 2nd of three workout program selection screens. This screen will show an additional five more pre-programmed workout profiles.
Press
A new screen will appear with additional programs: Heart Rate, Stess Test, Random, Power Fit and Heart Fit.
MORE
Heart Rate Program
The Heart Rate Transmitter Strap is required for this program. Refer to page 10 for a complete
instruction on using the strap and to understand
how to calculate your Target Heart Rate.
Put on Heart Rate Transmitter Strap
Adjust level intensity with the
keys, then press
Time 15:00
Level 1.0
Weight 150
Enter user weight with the keys,
then press and begin exercise
Press Then
HEART RATE
Time 15:00
Heart Rate 120 Weight Rate 150
Adjust the workout time with the
keys, then press
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
14
Heart rate Cont’d
PROGRAM INSTRUCTIONS
Time 15:00
Heart Rate 120
Weight 150
Adjust the target Heart Rate with the
keys, then press
Time 15:00
Heart Rate 120
Weight 150
Enter the user weight with the
keys, then press and begin exercise
First Target 50
Increment 5
Interval 5:00
Select wattage increments after each interval with
the keys, then press
First Target 50
Increment 5
Interval 5:00
Select the length of each interval with the
keys, then press
Stress Test
A designed step test to be used as training program or use with other diagnostic devices (if appropriate). The user sets a target wattage with timed intervals and preset wattage increments.
First Target 50
Increment 5
Interval 5:00
Weight 150
Enter user weight with the
keys, then press and begin exercise
Increment 5 Interval 5:00
Select target wattage with the
keys, then press
15
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
Random Program
The Intelli-Fit console will randomly display different workout profiles each with its own level of difficulty. The operator only has to choose the type of the profile, then select the time length of the workout and the level difficulty.
Note: The highest column of the profile represents the workout level you selected. Columns below it are percentages of the level selected.
Prole Random
Time 15:00
Level 1.0
Adjust level intensity with the
keys, then press
Press Then
RANDOM
Prole Random
Time 15:00 Level 1.0
Select a random profiles with the
keys, then press
Prole Random
Time 15:00
Level 1.0
Time 15:00
Level 1.0
Weight 150
Enter user weight with the keys,
then press and begin exercise
Adjust workout time with the
keys, then press
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
16
PROGRAM INSTRUCTIONS
Power Fit Programs
This key displays two options “Test” and “Training”. These programs are power and strength indicators for the user.
Press and the screen will display
a choice of “Test” or “Training” as shown below.
Power Fit
Power Fit
Test
Training
More
Training
Specifically designed preset wattage training programs based off user Power Fit test evaluation.
Three programs and four levels (Beginner, Intermediate, Advanced and Sport Performance) are available.
Press Then
Program 1
Level Beginner Weight 150
Select 1 of 3 programs with the
keys, then press
TRAINING
Test
This program is based on a pre-programmed wourkout designed to evaluate your “Power Drop %”, which gives a fitness indication of power and strength using wattage as the main measurement.
Press Then
and begin exercise
TEST
Program 1
Level Beginner
Weight 150
Select 1 of 4 levels with the keys,
then press
Program 1
Level Beginner
Weight 150
Enter user weight with the keys,
then press and begin exercise
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
17
PROGRAM INSTRUCTIONS
Heart Fit Programs (Use Chest Strap)
This key displays two options “Test” and “Training”. These programs are Heart Rate recovery indicators for the user.
Press and the screen will display
a choice of “Test” or “Training” as shown below.
Heart Fit
Heart Fit
Test
Training
More
Level Beginner
Weight 150
En ter us er w eig ht w ith th e keys,
then press and beg in exerci se
Training
Designed training programs based on the user’s evaluated Heart Fit test. A training schedule with retesting is recommended. The user has three programs and four levels: Beginner, Intermediate, Advanced and Sports Performance to choose from.
Press Then
TRAINING
Test
This program is based on a pre-programmed workout designed to evaluate your Heart Rate recovery. The user can select from 1 to 4 levels: Beginner, Intermediate, Advanced and Sports Performance.
Press Then
Level Beginner
Weight 150
Select 1 of 4 lev els with th e k eys,
then press
TEST
Level Beginner
Program 1 Weight 150
Select 1 of 4 lev el w ith the keys,
then press
Level Beginner
Program 1
Weight 150
Select 1 of 3 programs w i th the
key s, then press
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
18
PROGRAM INSTRUCTIONS
Training Cont’d
Level Beginner
Program 1
Weight 150
En ter us er w eig ht w ith th e keys,
then press and beg in exerci se
Additional Key Feat ures
SCIFIT has also included extra user friendly key features the user may use during a workout.
CHANGE
Allows the user to change the viewing fomat of the workout profile and data displayed on the LCD screen during the workout.
VIE
W
If at anytime the user may want to pause during a workout, this may done by pressing the [Pause/Clear] key. The screen workout will then minimize and provide the user three options
1. Continue - Maximizes the workout screen and continues the workout where the user had stopped.
2. Change - Returns to a sub-menu where information may changed that was previously entered by the user.
3. Stop - Exits the workout and returns to the main menu.
Note: The console will reset to the main menu after a short period of time if no selection is made.
FAN
The console contains two 3-speed cooling fans that can be activated by the user at anytime.
Power Burst
When activated a count down will display on the screen for the user to prepare to pedal faster for a small duration of time. This time duration can be increased or decreased in the “User Set-up”.
19
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
MAI NTENANCE & SERVICE
Maintenance
The ISO1000 & ISO7000 are virtually maintenance free. After training, always wipe down your SCIFIT exercise product. Perspiration that continuously settles on the frame, upholstery, casings, and control console may eventually cause rust or damage. Damage resulting from lack of maintenance is NOT covered under warranty.
If defective identi
components are
ed and require replacement, the equipment
should be put out of service until repaired.
CAUTION
I
n order to maintain a safe level of operation
equipment mus t be inspec ted on a routine basis for damaged or worn parts. F ailure to inspect equipme nt may result in injury to yourself or others
ISO1000/7000 Maintenance Schedule
Any mechanical or electrical work conducted within the main body of a medical CE class IIa unit MUST BE RECALIBRATED. The generic maintenance schedule below should be applied to medical CE and non-medical CE products.
COMPONENT USE WHEN BY WHOM
Covers, Seat, Damp Cloth Daily Club Maintenance
Handlebars and Console
,
.
UNITED STATES CUSTOMER SERVICE
For assistance in the service of SCIFIT products;
phone : (800) 745-1373 or (918) 359-2040 fax : (918) 359-2045 e-mail:
service@scifit.com
The Product Support department is staffed from 7:00 AM to 6:00 PM CST Monday through Friday. A voice mail service is a
vailable 24 hours a day for recording messages to request technical support and to order replacement parts. Our mailing address is:
SCIFIT Systems Inc. 5151 S. 110th E. Ave. Tulsa, OK 74146 USA
UK & EUROPEAN CUSTOMER SERVICE
phone : +44 1344 300022
fax: +44 1344 868838 e-mail: inf
o@scifit.uk.com
SCIFIT LTD (UK)
Lexham House Forest Road Bin
eld
Berkshire, RG42 4HP UK
LCD Screen LCD TV Screen Weekly Club Maintenance
Soft Cleaning Cloth
Chains (ISO7000) Lightly Applied Quarterly Club Maintenance Chain Lubricant
Nuts and Bolts Tighten When Bimonthly Club Maintenance Neccessary
Order on line 24/ 7 at w w w .SCIFI T.c om
SCIFIT • Scientific S olutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFI T
Company Number: 5970624 (
*COUNTRIES OUTSIDE OF UK & EUROPE
PLEASE USE USA CONTACT NUMBERS*
20
UK)
WARRANTY
t is very im portant that your
I
online
http://www.SCIFIT.com/warrantyregistration.shtml
at
SCIFIT
machine is registered
registratio n form at the back of this manual
SCIFIT Statement of Warranty
SCIFIT
normal and proper use subject to the following limitations
warranties new products against defective workmanship and/or materials under
a
) S C IFIT’s
(
ithin the United States and Canada both parts and the cost of labor required to
W
replace or repair a defective product for a period of one
purchase date as been retur
for a period of two replacement parts or products with any labor costs associated with such replacement or repair to be at Buyer’s expense components outside this policy clause
O
labor for a period of three
*
warranty card and if warranty
shipment from factory
obligation to the original purchaser shall apply to
documented by *warranty card and if warranty card has not
ned by user/dealer, then date of shipment from the factory. T
years, such obligation shall extend only to the supply of
(2)
.
utside the United States and Canada replace defective product with no
(3)
years from user purchase date as documented by
card
has not been returned by user then date of
.
*N
ote warranty card return, web site registration or fax to activate warranty period or shipment date is extant for start of warranty period be given for warranty registration to allow stock rotation and showroom stock thereafter none registration will be shipment date for the start of the warranty period
riginal purchaser must register their purchased products either by
: O
.
his can be done
. T
fill out and mail the
or
.
:
:
(1)
year from
. R
efer to clause (e) for
. A
ninety
(90)
user/dealer
hereafter
day period is to
,
(
(
b
) S CIFIT’s
o allowance shall be granted for repairs made by Buyer without
N
written approval discretion
c
) S CIFIT’s
to normal and abnormal wear and tear, improper use, corrosion (perspiration improper maintenance, improper installation, improper rated, grounded or dedicated electr part of the product has been altered from its original state by Buyer or a third party
.
obligation shall be limited to repairing or replacing defective parts
. The
.
warranty does not apply to parts requiring replacement or repair due
ical
decision to replace or repair shall be solely at
circuits or improper storage, nor does it apply where all or
(d) THIS WARRANTY IS IN L IE U OF ALL OTHER WARRANT IE S,
EXPRESSED OR IMPLIED, ARISING B Y LAW OR OTHE R WISE INC LUDING WARR ANTY OR MERCHA NTA B ILITY OF FITNE S S FO R P A RTIC UL A R PUR P OSE, AND IS IN LIE U OF ALL OTHER LIAB IL ITIES OF S C IFIT INC L UDING DIRE C T, INDIRE C T, SPECIAL AND CONSEQUE NTIAL DA MAGES OR PENA L TIE S EXPRESSED OR IMPLIED WHETHE R ARISING OUT OF C ONTRACT, NEGLIGENC E OR OTHE R SORT.
21
Solutions for Fi
SCIFIT • Scientific
SCIFIT SCIFIT SCIFIT
Solutions for Fi
tness • SCIFIT • Scientific
SCIFIT’s
SCIFIT’s
tness •
prior
.
),
SCI FIT
WARRANTY
SCIFIT STATEMENT OF WARRANTY
2
. 21 s e r ud e c o rP e c i vre S dn a y c i l o
(e) The
determined to be defective
readmills
T
readmill belts
T
readmill Decks
T
readmill structure
T
readmill drive system inclusive of
T
motor
readmill Handrails
T Treadmill Heart rate grips 12 months Treadmill water bottle holders 90 days
readmill trays
T
pholstery
U
S
addles/Seats
Rotary Pedals 12 months Rubber grips Heart rate grips
Rotary structure & F rame Rubber foot Pads (BioFlex) 12 months Rotary water bottle holders Rotary trays
below listed items have the following warranty coverage unless
hes e items include, but are not limited to
. T
– AC5000
only
inverter
&
Rotary Products Warranty Period
90
12
12
models
frame
&
andles
& H
5
3
W
arranty
months
12
months
12
years
5
years
years
days
months months
months
12
months
12 5 years
days
90 90
days
P
eriod
:
Accessories Products Warranty Period
P
edal straps
Heart R ate Receiver/Transmitter 90 days
Low support boots 12 months
High support boots
Assist gloves 90 days USB Keys and Lanyards 90 days
(f) Fires, floods, and acts of God, are not covered under this warranty.
SCIFIT • Scientific S olutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFI T
N
22
ormal wear
12
months
&
tear
WARRANTY
reight and Shipping
F
s e r u d e c o r
3 . 2 1
P
e c
SCIFIT
during transit or installation part for shipping damage at time of delivery or installation, and prior to signing receiving paperwork appropriate transit company
is not responsible for the repair or replacement of any unit or part damaged
customer is responsible for inspection of each unit and
.
If the customer signs an unqualified receipt for freight
. The
. The
customer is responsible for pursuing all freight damage claims with the
damage goods, the customer is solely responsible for the cost of the repair or replacement for such freight damage.
M
aintenance
After training, always wipe down your SC IFIT exercise product. Perspiration that continuous ly settles on frame, upholstery, cas
ings
and control panels may eventually cause rust or damage.
D
amage resulting from lack of maintenance will
under warranty. To clean upholstery, use mild soap and warm water. Dry with a clean towel. Refer to the Treadmill maintenance schedule.
NOT be
covered
roduct Support
P
Assistance for the service of
or fax (918) 359-2045.
C
entral Time Monday
for
recording messages to
O
ur goal is to return every
our
normal business hours.
P
lease have the following information prior to calling technical support:
The product support department is staffed from 7 AM to 5 P M
through Friday
Model number of equipment
erial number of equipment
S P oint of contact name and phone number Detailed description of symptoms encountered.
SCIFIT • Scientific S olutions for Fitness • SCIFIT • Scientific Solutions for Fitness •
SCIFIT
request technical support and to order replacement parts.
voicemail call within 30 minutes of when it is placed during
SCIFIT SCIFIT SCIFIT
products is available by calling
. A
voicemail service is available
23
(800) 745-1373
24
hours daily
SCI FIT
WARRANTY
I
nstallation
SCIFIT
during installation damage at the time of installation
claims with the installer.
I
f an order includes software, such computer software is transferred by
customer pursuant to a single user license, the royalty, term
set forth on or in the package accompanying such software
K
eyMaster software will receive
eligible for product upgrades for one year following purchase
SCIFIT T
hes e names must not be used by other entities in the fitness business
SCIFIT
copied without prior approval fro
is not responsible for the repair or replacement of any unit or part damaged
. The
customer is responsible for inspection of each unit and part for
. The
S
oftware, Trademarks, Copyrights, and Patents
1
year of call-in technical support and owners will be
has trademarked several names to uniquely identify its business and products
decals,user’s manuals, and service manuals are copyrighted and may not be
SCIFIT.
m
customer is responsible for pursuing all damage
SCIFIT to
,
s
and conditions of that are
.
.
.
the
.
SCIFIT
products features
D D
next day delivery
requiremen overnight or 2nd day parts shipping, at customers expense. If requested, SC IFIT will charge the customer’s ground shipment and overnight or 2nd day
has obtained several patents on features and des igns that are unique to its
. SCIFIT
and des igns in other products
uring the first 30 days warranty parts will be shipped via overnight delivery.
etermination must be made before
ts
will defend these patents against those who attempt to utilize these
.
P
arts Shipment
2:00 PM C
. D
uring the remainder of the first year warranty period
will be filled via ground shipment
UP S
account,or
COD
entral Time on any given weekday for
,
parts
. The
the difference in freight cost between
customer is welcome to request
.
24
SCIFIT • Scientific
Solutions for Fi
tness • SCIFIT • Scientific
SCIFIT SCIFIT SCIFIT
Solutions for Fi
tness •
SCI FIT
WARRANTY
eturn of Parts
R
SCIFIT
meet this commitment, the rapid return of defective parts is essential of the parts by our engineering department leads to changes that insure the same problem does not re-occur
W
within the parts invoice net
is committed to continual improvement in the equipment we market
hank you in advance for your assistance
. T
hen requested by
days of receipt of replacement part
20
SCIFIT,
days
30
defective parts must be returned to the
ther
. O
wise
SCIFIT
.
. The
!
SCIFIT
will expect payment on
order to
. In
examination
factory
Please follow these three easy steps for returning parts.
tep
S
1
K
eep the box and packing material in which the new parts arrived
S
2
tep
W
rap the defective part and place in the box for safe return moment needed to fill in the return parts form that is enclosed in the box with the new parts
.
tep
S
3
. P
.
lease take the brief
A UPS prepaid Return L abel will be in the part box for only those parts that need to be
returned
iss ued for the original parts invoice
be will NOT be paid until defective parts are returned to the factory.
. W
hen
ALL of
the parts are received and inspected at the factory, a credit will
ttention s ervice companies
. A
labor invoices
-
Service Labor
W
here applicable, the SCIFIT product support personnel will arrange a local field service technician to provide field support. E very effort will be made to schedule service during
48
business hours (8 hours per business day) following notification of a problem or as
soon as repair parts are available to the field service technician. Where possible, parts will be supplied in advance of the field service technicians so that the product is repaired with one call.
urchased Parts
P
ll purchased parts will carry a
A
installation for more details.
his Limited C ommercial Warranty supercedes the limited commercial warranty printed
T
in the
f you have questions or require additional information, please contact SC IFIT Sys tems,
I
sers Operation Manual” for all
“U
nc. at
I
1-800-745-1373 or
12
month
warranty
efer to Purchased parts shipments and
. R
SCIFIT S
service@ scifit.com
ystems
, Inc.
products
.
25
SCI FIT
SCIFIT • Scientific S olutions for Fitness • SCIFIT • Scientific Solutions for Fitness •
Warranty Card
Register online at http://www.SCIFIT.com/warrantyregistration.shtml or complete this form, fold it and return it to SCIFIT. We request you send this card within 2 weeks after your equipment has been delivered to insure proper warranty registration.
Company Name
Contact Name
Address
City/State/Zip
Home Phone (____) Business Phone (_____)
Model Purchased
Date Received Serial Number
Entity Purchased From
City/State
Please rank the following reasons (1 through 6) for selecting SCIFIT with 1 being most important:
____Features ____ Quality ____Price ____Dealer ___User Friendly ___Appearance
Please Check the appropriate box(s) on how you were introduced to SCIFIT:
Saw in __________________________ Magazine
Introduced by SCIFIT Dealer
Saw at __________________________ Tradeshow Referred by SCIFIT User
Other
Comment
Thank You For Choosing
SCIFIT
Email Address
www.SCIFIT.com
Scientific Solutions For Fitness
TM
R
P2278 Rev. B
Warranty Card 14.1
SCIFIT t Scientic Solutions for Fitness t SCIFIT t Scientic Solutions for Fitness t SCIFIT t Scientic Solutions for Fitness t SCIFIT
Tulsa, OK 74146
SCIFIT
5151 South 110th East Avenue
______________________________ ______________________________ From _________________________
Important: Please keep this page for “Recalibration Records”
Model Number:
Serial Number:
Date of Purchase:
Calibrat ion Dat e ( Medical units) :
Supplied By: SCIFIT Systems Inc.
User Manual: # P4665 Rev. A (11/ 2 010)
1st Recalibration
2nd Recalibration
3rd Recalibration
4th Recalibration
5th Recalibration
DATE
CLUB OR CERTI FI CATI ON LOCATI ON
CERTI FI ED SERVI CE COMPANY
TECH I NI TI ALS
Please make extra blank chart copies for future use
5151 South 110th East Avenue
Tulsa, Oklahoma 74146
USA
Sales: 1-800-278-3933 • 1-918-359-2000
Customer Service: 1-800-745-1373
www
.scifit.com
Order online 24 / 7 at w w w.SCI FI T.com
Loading...