Scientific Industries SI-A536, SI-A546, SI-A586 Instruction Manual

U.S. PAT 4,781,487
70 Orville Drive, Bohemia, NY 11716 U.S.A.
(631) 567-4700 • Fax: (631) 567-5896 • Toll Free: 888-850-6208
Customer Service: custsvc@scientificindustries.com
www.scientificindustries.com
DIGITAL VORTEX-GENIE®2 Mixer. Review instruction 3.0 before attempting to change attachments.
To initiate the "FT" mode, press the MODE button until MIN is illuminated above the START/STOP text. Next, press the UP/DOWN arrow buttons beneath the TIME window to set the desired mixing time. Next, set the speed control by pressing the UP/DOWN arrow buttons beneath the SPEED window. Press the START/STOP button to begin the mixing action. The mixer will run until the set time has elapsed. To stop the cycle before the set time has elapsed, press the START/STOP button. To initiate a new timed cycle, press the START/STOP button again.
2.4 - "FC" (HANDS FREE CONTINUOUS) The "FC" mode allows for unattended operation that will continue indefinitely until you stop the cycle by pressing the START/STOP button. In this mode, you may also use any of the accessory attachments available for the DIGITAL VORTEX-GENIE 2 Mixer.
To initiate the "FC" mode, press the MODE button until MIN is illuminated above the START/STOP text. Next, press the DOWN arrow beneath the TIME window until the illuminated display reaches "0". Upon releasing the button, the display will have two dash marks (--), indicating that no time limit is set. Next, set the speed control by pressing the UP/DOWN arrow buttons beneath the SPEED window. Upon pressing the START/STOP button, the mixer will start and continue to run, unattended, until you once again press the START/STOP button. To restart the cycle, press the START/STOP button again.
2.5 - "SLEEP" The mixer will automatically go into a "SLEEP" mode if the mixer is plugged in but not used for 10 minutes. The TIME and SPEED illuminated displays will go blank and the SEC or MIN illuminated display will blink. Press the START/STOP button to "WAKE UP" the mixer.
Note: The speed control can be adjusted up or down during the mixing cycle,
however, the TIME can only be adjusted before the cycle begins.
3.0 - To change accessory mixing attachments, the following sequence is to be followed explicitly.
3.1 - Turn the power OFF by unplugging the unit from the outlet.
3.2 - Grasp the installed attachment and pull straight up until it releases from the shaft. A technique of lifting the attachment with your finger tips while using your knuckles as a fulcrum will give you the leverage to remove the installed attachment component smoothly.
3.3 - Hold the part you wish to install so the "flat" part of the shaft is aligned with the "flat" of the receptacle in the attachment component. Alternatively, you may place the attachment component on the shaft and turn it until you feel the "flats" aligning.
3.4 - Press attachment component firmly downward until it "snaps" into place. The DIGITAL VORTEX-GENIE 2 Mixer is now ready to use with the newly installed accessory attachment. Plug the unit back into the electrical outlet. Follow instructions
1.0 through 2.5 for proper use of the mixer.
Note: When installing the Microplate Adaptor press firmly down on the areas
indicated on the adaptor base. DO NOT press down on sidewalls as this may bend the attachment.
4.0 - With prolonged use, your DIGITAL VORTEX-GENIE 2 Mixer may become warm to the touch. It should not get HOT to the touch. The motor will radiate a certain amount of heat that will be dissipated by the cast zinc case.
The DIGITAL VORTEX-GENIE
2 for Applied Biosystems is a specially configured mixer for Applied Biosystems' Microplate Protocols ONLY. This is an enhanced version of the ORIGINAL VORTEX-GENIE
Mixer produced by Scientific Industries. VORTEX-GENIE mix­ers are the "Gold Standard" for laboratory mixers. The quality and reliability, that you have come to know so well, are characteristics that are, by design, an integral part of all "GENIE™" products.
APPLICATIONS
The Microplate Adaptor for Applied Biosystems’ Microplate Protocols, securely holds Applied Biosystems’ 96-well plates and 384-well plates. To review Applied Biosystems’ protocols please visit their website at www.appliedbiosystems.com/gameoverblobs.
The 3-inch Platform part no. 0K-0500-902 (not supplied) may be purchased separately for use with single or multiple test tubes, beakers and various flasks.
The Pop-off Cup part no. 146-3011-00 (not supplied) may be purchased separately for use with virtually any size or shaped tube, from microtubes to those up to 40mm in diameter and 200mm in length.
OPERATING INSTRUCTIONS
1.0 - Plug the line cord into a properly grounded electrical outlet.
(120 VAC for the SI-A536 model; 230 VAC for the SI-A546 model; 100 VAC for the SI-A586 model). Illuminated numbers will appear in the TIME and SPEED
windows indicating that the unit is ON and ready for use.
2.0 - The DIGITAL VORTEX-GENIE 2 Mixer has the following modes of operation:
2.1 - "TT" (TIMED TOUCH - 1 to 99 seconds)
This mode can only be used with the optional 3-inch Platform or Pop-off Cup.
For procedures that require short duration vortex mixing from 1 to 99 seconds. Or, for procedures that require accurate and repetitive vortex mixing sequences of 1 to 99 seconds each.
To initiate the "TT" mode, press the MODE button until SEC is illuminated beneath the word TOUCH. Press the UP/DOWN arrow buttons beneath the TIME window to set the desired mixing time. Next, set the speed control by pressing the UP/DOWN arrow buttons beneath the SPEED window. When you touch a tube or other vessel to the 3-inch Platform or Pop-off Cup, the mixer will start and run for 1 to 99 seconds, depending on the TIME setting. The mixer will automatically turn off at the end of the 1 to 99 second cycle. Releasing the pressure on the 3-inch Platform or Pop-off Cup and then re-applying the pressure will initiate another 1 to 99 second cycle. The mixing cycles will be precisely timed and you may initiate as many mixing cycles as you wish.
2.2 - "CT" (CONTINUOUS TOUCH)
This mode can only be used with the optional 3-inch Platform or Pop-off Cup.
The "CT" mode allows for operation that will continue indefinitely until you release pressure on the 3-inch Platform or Pop-off Cup.
To initiate the "CT" mode, press the MODE button until SEC is illuminated above the START/STOP text. Next, press and hold the DOWN arrow button beneath the TIME window until the illuminated display reaches "0". Upon releasing the button, the display will have two dash marks (--), indicating that no time limit is set. Set the speed by pressing the UP/DOWN arrow buttons beneath the SPEED window. Apply pressure to the 3-inch Platform or Pop-off Cup to initiate mixer. Release pressure to stop mixer.
2.3 - "FT" (HANDS FREE TIMED - 1 to 99 minutes) The "FT" mode allows for unattended operation that is timed from 1 to 99 minutes. In this mode, you may use any of the accessory attachments that are available for the