Schweigen UM1390-6SEL, UM1390-9SEL Installation Manual

INSTALLATION GUIDE
Endline Isodrive System 1350
02.2018 / V1.0
www.schweigen.com.au
Welcome
Thank you for purchasing your new Schweigen Endline Isodrive system.
This guide contains important information on the correct use and maintenance of the unit, as well as important safety notes. This will ensure your personal safety and the lasting value of your Isodrive system.
Please always retain your proof of purchase to aid in any warranty queries.
This appliance and its packaging are produced by processes that minimise waste and respect the environment.
Please help us to continue this eort to protect the environment by using the appliance eciently and dispose of the packaging in a responsible manner.
Page 2
Index
1. Welcome _____________________________________________________________________________________2
2. Your Safety
Receiving your Isodrive Motor ____________________________________________________________________ 4 Before Installation ______________________________________________________________________________ 4 Electrical Cord __________________________________________________________________________________ 4 Motor Features ________________________________________________________________________________ 5 General Notes on Installation and Use ____________________________________________________________ 5 Recommended Installation Distance _____________________________________________________________ 5 Minimum Mounting Height ______________________________________________________________________ 6 Avoidance of Back Flow _________________________________________________________________________ 6 Replacement of Supply Cord _____________________________________________________________________ 6 Why Flexi-duct _________________________________________________________________________________ 6
3. Description
Isodrive Motor - Box Contents ___________________________________________________________________ 7 Dimensions ____________________________________________________________________________________ 7 Installation Overview ___________________________________________________________________________ 8
4. Motor Installation
Wall Installation __________________________________________________________________ 8 Full Housing Assembly - Cross Section ____________________________________________________________ 10 Removable Motor Assembly _________________________________________________________ 11 Wall Aperture Cut Out ______________________________________________________________ 12 Motor Housing to Wall Fitment _______________________________________________________ 12 Front View of Motor Housing (view from behind front grille) _________________________________ 13 Installation using Optional Rear Clamp Assembly _________________________________________ 13 Attaching Optional Fire Ember Mesh Guard (Exploded view) __________________________________ 14
5. Flexible Ducting Installation
Flexible Ducting __________________________________________________________________ 15 Shallow Space ___________________________________________________________________ 15 Important Note __________________________________________________________________ 15 Securing Flexible Duct _____________________________________________________________ 16
6. Parts List
Parts List for Endline Isodrive 1350 Motor _______________________________________________17
7. Maintenance
Cleaning ________________________________________________________________________ 18
8. Specications/Warranty/Disclaimer ________________________________________________________ 18
Page 3
2. Your Safety
RECEIVING YOUR ISODRIVE MOTOR
Please read this section thoroughly before attempting to operate the appliance. Inspect your product upon receipt. Any damage or defects MUST be reported
within 48 hours, or no claim will be recognised.
DO NOT INSTALL THIS APPLIANCE IF YOU FIND IT DAMAGED.
If this product is installed damaged, the supplier, nor the retailer, will be responsible for the costs associated with the repair, replacement, removal or re-installation of the appliances.
This appliance is not intended for use by person/s (including children) with reduced physical, sensory or mental capabilities, or lack of experience and/ or knowledge. Unless the person has been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance, it is not a toy.
Do not install Isodrive motor to a non-Schweigen and/or non-silent rangehood. If you fail to do so, your warranty will be voided.
The manufacturer declines all responsibility in case of failure to adopt proper safety measures.
Ensure that the location in which this appliance is installed, has good and permanent ventilation.
Please consult local laws and regulations and install in accordance.
Use an electrical connector with earth that is correct for your location.
Before Installation
We recommend this appliance to be installed or repaired by a qualied Schweigen Home Appliances technician.
Please see our website www.schweigen.com.au for recommended installers.
It is dangerous to modify any part of this appliance. Modication of any kind, will immediately void the warranty.
Electrical Cord
Ensure the supply cord is not exposed to heat, chemicals or sharp objects. If the supply cord is damaged, it must be replaced by the manufacturer, service agent or a similarly qualied person in order to avoid a hazard. The power supply cord connection MUST BE installed in such a way that access is easy in case of emergency.
Check that the voltage in your area corresponds to the appliance as indicated on the rating label.
Page 4
2. Your Safety
This guide is for the installation of the Isodrive motor system after the rangehood has been mounted. (Refer to rangehood installation manual on how to install the rangehood).
NOTE: All exi ducting measurements are referring to inside measurements, unless otherwise mentioned.
Motor Features
• IPX4 degree of weather protection.
• Super quiet, long vane, backward curved centrifugal fan.
• Airow is dependant on installation and the ducting used. Using single 200mm exi-duct will
3
deliver up to 1350m
than 200mm exi ducting would result in a loss of airow and it is not recommended.
Simple installation: Industrial quality motor and fan made in Germany and rated at 40,000 hours.
• Motor is a high eciency PSC type and rated at 88W costing around the same as two 40W light globes to run.
• WARRANTY 10 YEARS covers faulty manufacturing or components. It does not cover normal wear and tear.
/hr. The use of a smaller
WARNING: The Endline Isodrive 1350 Motor System must be installed into an external wall cavity. The motor can not be installed into an internal wall cavity or ceiling space where a build up of grease can occur and become a potential re risk. This will void warranty.
NOTE: Fan module and dual foil exi-duct are acoustically matched. Use of semi-rigid or rigid ducting will result in increased noise and may void warranty. See installation instruction notes ‘Why exi­duct’.
Recommended Ducting Installation Distance
Schweigen recommends a length of 4 to 6 metres of exi ducting, with at least 1 to 2 bends for optimal performance. Any shorter distances may result in higher airow noise. The maximum ducting installation length is 10 metres. Check with supplier if longer duct length is required. Do not reduce the 200mm exi duct size at any time and avoid
sharp bends.
General Notes on Installation and Use
This fan unit is designed to be installed using 200mm exi ducting.
This fan is suitable for connection to ducting runs
2
with a minimum inlet area of 17,000mm up to 10m maximum (check with supplier if longer duct length required). Where possible exible ducting must be extended suciently to present a smooth air passage with bends of at least the radii of twice the diameter of the duct. Excessive bends in the
ducting will compromised extraction.
and length
Page 5
2. Your Safety
Minimum Mounting Height
This fan unit is intended for mounting at a minimum height of 2.1 metres (measured to the lower part of the fan impeller) above a oor or the ground.
Avoidance of Back Flow
Care should be taken to avoid the back ow of gases into the room from the open ue of gas or other open re appliances.
Replacement of supply cord
If the supply cord is damaged, it must be replaced by a service agent or suitably qualied person in order to avoid a hazard.
NOTE: Do not use with a timer.
Why Flexi-duct?
Some internet sites strongly recommend the use of rigid ducting over fully exible ducting. This may well be the case with conventional rangehoods with internal motors but not with external motor rangehood.
Schweigen’s unique Isodrive system works in the opposite way to conventional rangehoods, pulling air through the hood and acoustically matched ducting, producing almost silent high volume ow. The use of a complete rigid or semi-rigid ducting system will allow an organ piping eect to occur; like a didgeridoo where a noise is produced at one end of a hollow rigid pipe and the noise is amplied out the other.
The Isodrive system drives the noise outside the house.
WARNING:
Installation without the use of at least the minimum recommended length of acoustically matched exi-ducting in the system will void performance expectations. Any installation problem must be reported to Schweigen. Call outs relating to incorrect installation will result in a service fee direct to the customer. Schweigen takes no responsibility for problems caused by faulty installation, this may void warranty.
Page 6
A preferred installer list can be obtained from Schweigen website www.schweigen.com.au or by calling 1300 881 693.