Schweigen PKGA-1200SE, PKUM11709BSE, PKSCC1200-SE, PKCC-INARTSE, PKUM1390-9BSE User Manual

...
INSTALLATION GUIDE
Isodrive 3200
Under our policy of continuous product development,
product specications may change without notice.
Please refer to the online version of the manual for the
latest updates and specications.
www.schweigen.com.auRevision V5 06/05/22
Thank you for purchasing your new Schweigen Isodrive system.
To get the maximum output from this unit, please read through this guide before use and installation.
This guide contains important information on the correct use and maintenance of the unit, as well as important safety notes. This will ensure your personal safety and the lasting value of your Isodrive system.
Please always retain your proof of purchase to aid in any warranty queries.
This appliance and its packaging are produced by processes that minimise waste and respect the environment.
Please help us to continue this eort to protect the environment by using the appliance eciently and dispose of the packaging in a responsible manner.
Page 2
Index
1. Welcome _____________________________________________________________________________________2
2. Your Safety
Receiving your rangehood ______________________________________________________________________ 4 Before Installation ______________________________________________________________________________ 4 Electrical Cord __________________________________________________________________________________ 4 Motor Features ________________________________________________________________________________ 5 General Notes on Installation and Use ____________________________________________________________ 5 Recommended Installation Distance _____________________________________________________________ 5 Minimum Mounting Height ______________________________________________________________________ 6 Avoidance of Back Flow _________________________________________________________________________ 6 Safety of Children ______________________________________________________________________________ 6 Replacement of Supply Cord _____________________________________________________________________ 6
Why Schweigen SteelFlex
3. Description
Isodrive Motor _________________________________________________________________________________ 7
Safety Duct __________________________________________________________ 6
4. Installation
Roof Installation _______________________________________________________________________________ 8 Through Wall Installation ____________________________________________________________10 Twin 200mm Outlet Installation Example (3200 kit required) ________________________________12 Optional Backdraft Shutter Installation Through Roof ______________________________________13 Optional Backdraft Shutter Installation Through Wall _______________________________________14 Optional Weather Shield Installation Guide ______________________________________________15
5. Measurements
Measurements for Isodrive 3200 _____________________________________________________ 16
6. SteelFlex
SteelFlex Assembling SteelFlex
Safety Duct
Safety Ducting Installation _________________________________________________ 17
Safety Duct ____________________________________________________ 18 Shallow Roof Space _______________________________________________________________ 19 Important Note __________________________________________________________________ 19
Installing SteelFlex
Safety Duct _____________________________________________________ 20
7. Parts List
Parts List for Isodrive 320 ___________________________________________________________ 21
8. Maintenance
Roof Restoration or Cleaning ________________________________________________________ 23
9. Warranty/Disclaimer ________________________________________________________________________ 24
Page 3
2. Your Safety
RECEIVING YOUR RANGEHOOD
Please read this section thoroughly before attempting to operate the appliance. Inspect your product upon receipt. Any damage or defects MUST be reported
within 48 hours, or no claim will be recognised.
DO NOT INSTALL THIS APPLIANCE IF YOU FIND IT DAMAGED.
If this product is installed damaged, the supplier, nor the retailer, will be responsible for the costs associated with the repair, replacement, removal or re-installation of the appliances.
This appliance is not intended for use by person/s (including children) with reduced physical, sensory or mental capabilities, or lack of experience and/or knowledge. Unless the person has been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance, it is not a toy.
Do not install Isodrive motor to a non-Schweigen and/or non-silent rangehood. If you fail to do so, your warranty will be voided.
The manufacturer declines all responsibility in case of failure to adopt proper safety measures.
Ensure that the location in which this appliance is installed, has good and permanent ventilation.
Please consult local laws and regulations and install in accordance.
Use an electrical connector with earth that is correct for your location.
Check that the voltage in your area corresponds to the appliance as indicated on the rating label.
Before Installation
We recommend this appliance to be installed or repaired by an experienced Home Appliances technician.
Please see our website www.schweigen.com.au for experienced installers.
It is dangerous to modify any part of this appliance. Modication of any kind, will immediately void the warranty.
Electrical Cord
Ensure the supply cord is not exposed to heat, chemicals or sharp objects. If the supply cord is damaged, it must be replaced by the manufacturer, service agent or a similarly qualied person in order to avoid a hazard. The power supply cord connection MUST BE installed in such a way that access is easy in case of emergency.
Page 4
2. Your Safety
This guide is for the installation of the motor used in the Isodrive systems after the canopy/rangehood has been mounted on the wall or ceiling. (Refer to canopy/rangehood unit installation manual).
NOTE: All PVC pipe and SteelFlex
ducting measurements are referring to inside measurements, unless
otherwise mentioned..
Motor Features
• Roof and wall mounting with IPX4 degree of weather protection.
• Super quiet, long vane, backward curved centrifugal fan.
• Airow is dependant on installation and the ducting used. Using a single 250mm SteelFlex
3
should attain up to 3200m
/hr depending on the ducting installation. The use of a smaller than
250mm ducting would result in a loss of airow.
Simple installation: The motor mounts onto a 250mm PVC pipe for ultimate strength and allows for easy
Dektite roof sealing.
• Industrial quality motor and fan made in Germany and rated at 40,000 hours.
• Motor is a high eciency PSC type and rated at 150W costing around the same as two 70W light globes to run.
• WARRANTY 10 YEARS return to manufacturer. Covers faulty manufacturing or components. It does not cover normal wear and tear, chemical or storm damage etc. (see warranty card for more information).
duct, you
General Notes on Installation and Use
This fan unit is designed to be installed using 250mm (ISD) PVC pipe as the initial connection duct to the fan
module, and is supplied with a 250mm (ISD) PVC pipe and 250mm (ISD) SteelFlex
(see page 17 for installation
details).
This fan is suitable for connection to multiple duct runs with a minimum inlet area of 22,000mm
installing, maximum 8 metres of the 250mm SteelFlex
the ducting. Where possible SteelFlex
ducting must be extended suciently to present a smooth air passage
ducting MUST be used and no more than 2 to 3 bends in
2
. When
with bends of at least the radius of twice the diameter of the duct. Excessive bends in the ducting will
compromised extraction.
WARNING: The rangehood must not be ducted into a wall cavity or a ceiling space, where a build up of grease
can occur and become a potential re risk. This will void your warranty.
NOTE: Fan module and SteelFlex in increased noise and may void warranty. See installation instruction notes ‘Why Schweigen SteelFlex
duct are acoustically matched. Use of semi-rigid or rigid ducting will result
Safety Duct’.
Recommended Installation Distance
Isodrive 3200 motor, recommended 4 to 6 metres of SteelFlex™ ducting and with at least two bends.
NOTE: Although less than 4 to 5 metres will increase extraction power this may result in a higher air noise level. Maximum duct length 8 metres (use 250mm ducting), however please be aware that increasing the duct length above 5 metre will decrease airow. Check with supplier if longer duct length is required. Do not reduce the duct size at any time and avoid sharp bends.
Page 5
2. Your Safety
Minimum Mounting Height
This fan unit is intended for mounting at a minimum height of 2.1 metres (measured to the lower part of the fan impeller) above a oor or the ground.
Avoidance of Back Flow
Care should be taken to avoid the back ow of gases into the room from the open ue of gas or other open re appliances.
Safety of Children
This fan is not intended for use by young children or inrm persons without supervision.
Replacement of Supply Cord
If the supply cord is damaged, it must be replaced by a service agent or suitably qualied person in order to avoid a hazard.
Why Schweigen SteelFlex™ Safety Duct
Schweigen SteelFlex™ is an ultra-strong and exible high-performance safety ducting made
®
of Shirikon Firemesh Schweigen – the Silent Rangehood specialists, for quiet and ecient high-volume transfers of temperature-sensitive air. Engineered to enhance the health and safety of your home, Schweigen SteelFlex It is reproof, pest and crush proof with a treated surface that prevents the build-up of grease and bacteria.
Schweigen’s unique Isodrive system works in the opposite way to conventional rangehoods, pulling air through the hood and acoustically matched ducting, producing almost silent high volume ow. The use of a complete rigid or semi-rigid ducting system will allow an organ piping eect to occur; like a didgeridoo where a noise is produced at one end of a hollow rigid pipe and the noise is amplied out the other.
– a tri-layer tear-resistant UV-treated sleeve. Both are developed by
is antimicrobial treated, thermally insulated and acoustically dampened.
The Isodrive system places the noise outside the house.
WARNING: Installation without the use of at least the minimum recommended length of acoustically matched
SteelFlex to Schweigen. Call outs relating to incorrect installation will result in a service fee direct to the customer. Schweigen takes no responsibility for problems caused by faulty installation, this may void warranty. An experienced installer list can be obtained from Schweigen website www.schweigen.com.au or by calling 1300 881 693.
Page 6
in the system will void performance expectations. Any installation problem must be reported
NOTE
For more SteelFlex™ ducting instructions, refer page 17.
3. Description
Isodrive Motor
Included in the box:
1. Isodrive 3200 motor
Approx. 3 metre, 10amp cable and standard plug
2. Fire resistant 250mm outside dimension PVC riser pipe
3. SteelFlex
250mm (260mm outside dimension) diameter
4. SteelFlex
200mm (210mm outside dimension) diameter
5. 4 x Steel ring clamps
6. 6 x 20mm self-drilling button head screws
7. 250-200mm reducer (only use when connecting the
Isodrive 3200 motor to a single 200mm opening on a rangehood)
Not included in the box:
Roof seal kit / Dektite
Support straps for poly pipe which connects to the
roof truss
safety ducting (250mm). Approx. 4 metres,
safety ducting (200mm). Approx. 2 metres,
1
3 4
5
7
2
6
Aluminium foil tape
Wall Mounting Kit
Included with the 3200 Kit
(for rangehoods with twin outlets only)
8. SteelFlex
safety ducting. Approx. 2 metres,
200mm (210mm outside dimension) diameter
9. Y joint (250 X 200 X 200mm)
10. 2 x 200mm ring clamps
Optional:
10. Wall plate (P2025)
11. 250mm backdraft shutter (250MMBDSSBUILDASS)
12. Weather shield kit (ISO32000WGBUILDASS)
12
8
11
9
10
13
Page 7
4. Installation
Roof Installation
Recommended duct length: 3200 motor — minimum 4 metres, optimal 4-5 metres.
Mount 250mm (ISD) rigid PVC pipe securely to beams, trusses or other appropriate structures: refer gure 1. The pipe should be mounted vertically with the roof penetration being sealed using a Dektite or other appropriate sealing membrane or device when installing through a metal nished roof. DO NOT install on a over lapping join.
Ensure that the PVC pipe protrudes a minimum of 50mm past the top of the Dektite, checking that the fan assembly clears the roof cladding at upper edge as shown in gure 1 — Roof Mount Option.
Pass power cord and plug through mounting ange and pipe, then out the slotted PVC pipe for connection to the socket coming from the canopy/rangehood. Refer to gure 1.
Do not insert plug into socket outlet or switch on until installation has been completed. Fit fan module to pipe and x in position using side locking screw.
Certain external installation congurations may cause audible levels of noise to be heard due to the air being expelled from the motor. To minimize external noise disturbance you can use between 4 to 8 metres of SteelFlex duct to place the Isodrive motor in an appropriate position.
3
Please be aware that the 3200 motor is capable of expelling air at 3200m
/hr.
For more information on environmental noise limit and conditions please contact your local Council. We have a list of experienced installers available on the Schweigen website.
Do not install the SteelFlex
in a straight line and minimum of two gentle bends in the ducts is required.
Page 8
Power cord
4. Installation
3200 motor
250mm PVC Pipe
Dektite
50mm Pipe protrusion above
Fix pipe to fan module with side locking screws
250mm SteelFlex™ duct (minimum 4 metres ducting length fully extended)
Fit side supports to locate
Strap to supports
NOTE: Prevent any cord bunching by pulling cord through from plug top end
Connect to power supply
250-200mm reducer
200mm SteelFlex MUST keep taught
duct
Only use when connecting the motor to a single 200mm outlet on the rangehood.
Figure 1: Roof mount option
IMPORTANT
For more SteelFlex™ ducting instructions, refer page 17.
Page 9