Schweigen PKSCC1200-SP, PKUM11706BSP, PKUM11709BSP User Manual for PKUM11706BSP

INSTALLATION GUIDE
Isodrive 1600
Under our policy of continuous product development,
product specications may change without notice.
Please refer to the online version of the manual for the
latest updates and specications.
www.schweigen.com.auRevision V4 06/05/22
Thank you for purchasing your new Schweigen Isodrive system.
To get the maximum output from this unit, please read through this guide before use and installation.
This guide contains important information on the correct use and maintenance of the unit, as well as important safety notes. This will ensure your personal safety and the lasting value of your Isodrive system.
Please always retain your proof of purchase to aid in any warranty queries.
This appliance and its packaging are produced by processes that minimise waste and respect the environment.
Please help us to continue this eort to protect the environment by using the appliance eciently and dispose of the packaging in a responsible manner.
Page 2
Index
1. Welcome _____________________________________________________________________________________2
2. Your Safety
Receiving your rangehood ______________________________________________________________________ 4 Before Installation ______________________________________________________________________________ 4 Electrical Cord __________________________________________________________________________________ 4 Motor Features ________________________________________________________________________________ 5 General Notes on Installation and Use ____________________________________________________________ 5 Recommended Installation Distance _____________________________________________________________ 5 Minimum Mounting Height ______________________________________________________________________ 6 Avoidance of Back Flow _________________________________________________________________________ 6 Safety of Children ______________________________________________________________________________ 6 Replacement of Supply Cord _____________________________________________________________________ 6
Why Schweigen SteelFlex
3. Description
Isodrive Motor _________________________________________________________________________________ 7
Safety Duct __________________________________________________________ 6
4. Installation
Roof Installation _______________________________________________________________________________ 8 Flat Roof Installation ___________________________________________________________________________ 10 Wall Installation ________________________________________________________________________________ 11 Through Wall Installation with Backdraft Shutter _________________________________________ 13 Fan Unit Shutter Assembly for Isodrive 1600 ____________________________________________ 14 Twin Motor Installation _____________________________________________________________ 15 Single Motor Installation Twin 200mm Outlet ____________________________________________ 17
5. Measurements
Measurements for Isodrive 1600 _____________________________________________________ 18
6. SteelFlex
SteelFlex Assembling SteelFlex
Safety Duct
Safety Ducting __________________________________________________________ 19
Safety Duct ____________________________________________________ 20 Shallow Roof Space _______________________________________________________________ 21 Important Note __________________________________________________________________ 21
Securing SteelFlex
Safety Duct ______________________________________________________ 22
7. Parts List
Parts List for Isodrive 1600 __________________________________________________________ 23
8. Maintenance
Roof Restoration or Cleaning ________________________________________________________ 25
9. Warranty/Disclaimer ________________________________________________________________________ 26
Page 3
2. Your Safety
RECEIVING YOUR RANGEHOOD
Please read this section thoroughly before attempting to operate the appliance. Inspect your product upon receipt. Any damage or defects MUST be reported
within 48 hours, or no claim will be recognised.
DO NOT INSTALL THIS APPLIANCE IF YOU FIND IT DAMAGED.
If this product is installed damaged, the supplier, nor the retailer, will be responsible for the costs associated with the repair, replacement, removal or re-installation of the appliances.
This appliance is not intended for use by person/s (including children) with reduced physical, sensory or mental capabilities, or lack of experience and/or knowledge. Unless the person has been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance, it is not a toy.
Do not install Isodrive motor to a non-Schweigen and/or non-silent rangehood. If you fail to do so, your warranty will be voided.
The manufacturer declines all responsibility in case of failure to adopt proper safety measures.
Ensure that the location in which this appliance is installed, has good and permanent ventilation.
Please consult local laws and regulations and install in accordance.
Use an electrical connector with earth that is correct for your location.
Check that the voltage in your area corresponds to the appliance as indicated on the rating label.
Before Installation
We recommend this appliance to be installed or repaired by an experienced Home Appliances technician.
Please see our website www.schweigen.com.au for experienced installers.
It is dangerous to modify any part of this appliance. Modication of any kind, will immediately void the warranty.
Electrical Cord
Ensure the supply cord is not exposed to heat, chemicals or sharp objects. If the supply cord is damaged, it must be replaced by the manufacturer, service agent or a similarly qualied person in order to avoid a hazard. The power supply cord connection MUST BE installed in such a way that access is easy in case of emergency.
Page 4
2. Your Safety
This guide is for the installation of the Isodrive motor system after the rangehood has been mounted on the wall or roof. (Refer to rangehood installation manual on how to install the rangehood).
NOTE: All PVC pipe and SteelFlex
ducting measurements are referring to inside measurements, unless
otherwise mentioned.
Motor Features
• Roof and wall mounting with IPX4 degree of weather protection.
• Super quiet, long vane, backward curved centrifugal fan.
• Airow is dependant on installation and the ducting used. Using single 200mm SteelFlex
3
attain up to 1600m
/hr. The use of a smaller than 200mm ducting would result in a loss of
airow.
Simple installation: The motor mounts onto a 150mm PVC pipe for ultimate strength and allows for easy
Dektite roof sealing.
• Industrial quality motor and fan made in Germany and rated at 40,000 hours.
duct, you should
• Motor is a high eciency PSC type and rated at 155W costing around the same as two 70W light globes to run.
• WARRANTY 10 YEARS return to manufacturer. Covers faulty manufacturing or components. It does not cover normal wear and tear, chemical or storm damage, etc. (see warranty card for more information).
General Notes on Installation and Use
This fan unit is designed to be installed using 150mm (ISD) PVC pipe as the initial connection duct to the fan
module, and is supplied with a 150mm (ISD) PVC pipe to 200mm (ISD) SteelFlex
This fan is suitable for connection to ducting runs with a minimum inlet area of 22,000mm metres maximum (check with supplier if longer duct length required). Where possible SteelFlex be extended suciently to present a smooth air passage with bends of at least the radius of twice the diameter of the duct. Excessive bends in the ducting will compromised extraction.
WARNING: The rangehood must not be ducted into a wall cavity or a ceiling space, where a build up of grease can occur and become a potential re risk. This will void your warranty.
NOTE: Fan module and Steelex
duct are acoustically matched. Use of semi-rigid or rigid ducting will result in increased noise and may void warranty. See installation instruction notes ‘Why Schweigen SteelFlex Safety Duct’.
duct bell-mouth adaptor.
2
and length up to 10
ducting must
Recommended Installation Distance
Isodrive 1600 motor, recommended 5 to 6 metres of SteelFlex™ ducting and with at least two bends.
NOTE: Installations less than 5 to 6 metres will increase extraction power this will result in higher noise level.
Maximum duct length is 10 metres. Check with supplier if longer duct length is required. Do not reduce the duct size at any time and avoid sharp bends.
Page 5
2. Your Safety
Minimum Mounting Height
This fan unit is intended for mounting at a minimum height of 2.1 metres (measured to the lower part of the fan impeller) above a oor or the ground.
Avoidance of Back Flow
Care should be taken to avoid the back ow of gases into the room from the open ue of gas or other open re appliances.
Safety of Children
This fan is not intended for use by young children or inrm persons without supervision.
Replacement of Supply Cord
If the supply cord is damaged, it must be replaced by a service agent or suitably qualied person in order to avoid a hazard.
Why Schweigen SteelFlex™ Safety Duct
Schweigen SteelFlex™ is an ultra-strong and exible high-performance safety ducting made
®
of Shirikon Firemesh Schweigen – the Silent Rangehood specialists, for quiet and ecient high-volume transfers of temperature-sensitive air. Engineered to enhance the health and safety of your home, Schweigen SteelFlex It is reproof, pest and crush proof with a treated surface that prevents the build-up of grease and bacteria.
Schweigen’s unique Isodrive system works in the opposite way to conventional rangehoods, pulling air through the hood and acoustically matched ducting, producing almost silent high volume ow. The use of a complete rigid or semi-rigid ducting system will allow an organ piping eect to occur; like a didgeridoo where a noise is produced at one end of a hollow rigid pipe and the noise is amplied out the other.
– a tri-layer tear-resistant UV-treated sleeve. Both are developed by
is antimicrobial treated, thermally insulated and acoustically dampened.
The Isodrive system places the noise outside the house.
WARNING: Installation without the use of at least the minimum recommended length of acoustically matched
SteelFlex to Schweigen. Call outs relating to incorrect installation will result in a service fee direct to the customer. Schweigen takes no responsibility for problems caused by faulty installation, this may void warranty. An experienced installer list can be obtained from Schweigen website www.schweigen.com.au or by calling 1300 881 693.
Page 6
in the system will void performance expectations. Any installation problem must be reported
NOTE
For more SteelFlex™ ducting instructions, refer page 19.
3. Description
Isodrive Motor
Included in the box:
1. Isodrive 1600 motor (405W x 220H mm approx.)
Approx. 3 metre, 10amp cable and standard plug
2. Fire resistant 150mm (160mm outside dimension)
PVC riser pipe
3. SteelFlex
200mm (210mm outside dimension) diameter
4. Bell-mouth adapter ring
200mm duct to 150mm riser
5. Weather Shield
Should be installed to prevent rain/water entering the unit
6. Backdraft Shutter
7. 2 x Steel ring clamps for attaching ducting to rangehood
and motor
8. 6 x 20mm self-drilling button head screws
9. 3 x 20mm self-driling screws (for weather shield)
safety ducting. Approx. 6 metres,
1
3 4
5
7 8
2
6
Not included in the box:
Roof seal kit / Dektite
Support straps for poly pipe which connects to the
roof truss
Aluminium foil tape
Hanging bracket required for wall mount
Part number P1107
Wall Cover Plate (wall mount only)
Part number P1108
Mounting Flange (wall mount only)
Part number P40113MF
9
Page 7
4. Installation
Roof Installation
Recommended duct length: 1600 motor — 5 to 6 metres.
Mount 150mm (ISD) rigid PVC pipe securely to beams, trusses or other appropriate structures: refer gure 1. The pipe should be mounted vertically with the roof penetration being sealed using a Dektite or other appropriate sealing membrane or device.
Ensure that the PVC pipe protrudes at least 50mm past the top of the Dektite, checking that the fan assembly clears the roof cladding at upper edge, refer gure 1 – Roof Mount Option.
Pass power cord and plug through mounting ange and pipe, then out the slotted PVC pipe for connection to the socket coming from the canopy/rangehood. Refer to gure 4.
Do not insert plug into socket outlet or switch on until installation has been completed. Fit fan module to pipe and x in position using side locking screw.
Certain external installation congurations may cause audible levels of noise to be heard due to the air being expelled from the motor. To minimize external noise disturbance you can use between 6 to 10 metres of SteelFlex duct to place the Isodrive motor in an appropriate position.
3
Please be aware that the 1600 motor is capable of expelling air at 1600m
/hr.
For more information on environmental noise limit and conditions please contact your local Council. We have a list of experienced installers available on the Schweigen website.
Do not install the SteelFlex
in a straight line and minimum of two gentle bends in the ducts is required.
Page 8
1600 motor
4. Installation
Weather shield attachment (only for 1600 motor)
Power Cord
150mm PVC Pipe (Locking holes fan end)
Dektite
Bell-mouth Adaptor
NOTE: Prevent any cord bunching by pulling cord through from plug top end
50mm
Pipe protrusion above Dektite
Fix fan module using side locking screw
Fit side supports to locate pipe
Strap to supports
Ring clamp
Connect to rangehood
Connect to power supply
Figure 1: Roof mount option
Page 9
Loading...