Thank you for purchasing your new Schweigen Isodrive system.
To get the maximum output from this unit, please read through this guide before use and installation.
This guide contains important information on the correct use and maintenance of the unit, as well as important
safety notes. This will ensure your personal safety and the lasting value of your Isodrive system.
Please always retain your proof of purchase to aid in any warranty queries.
This appliance and its packaging are produced by processes that minimise waste and respect the environment.
Please help us to continue this eort to protect the environment by using the appliance eciently and dispose
of the packaging in a responsible manner.
2. Your Safety ....................................................................................................................................4
Before Installation ................................................................................................................................................................................ 4
Receiving your rangehood ................................................................................................................................................................ 4
Your Safety ..............................................................................................................................................................................................5
Motor Features .......................................................................................................................................................................................5
General Notes on Installation and Use......................................................................................................................................... 5
Avoidance of Back Flow ...................................................................................................................................................................... 6
Safety of Children ................................................................................................................................................................................. 6
Replacement of supply cord ............................................................................................................................................................. 6
Isodrive Motor ......................................................................................................................................................................................... 7
Through Wall Installation ................................................................................................................................................................... 10
Twin 200mm Outlet Installation Example (3200 kit required) ..........................................................................................12
Optional Back Draft Shutter Installation Through Roof ....................................................................................................... 13
Optional Back Draft Shutter Installation Through Wall ........................................................................................................14
Measurements for Isodrive 3200 (Not to Scale) ......................................................................................................................19
7. Parts List ........................................................................................................................................20
Parts List for Isodrive 3200 .............................................................................................................................................................. 20
Please read this section thoroughly before attempting to operate the appliance.
Inspect your product upon receipt. Any damage or defects MUST be reported
within 48 hours, or no claim will be recognised.
DO NOT INSTALL THIS APPLIANCE IF YOU FIND IT DAMAGED.
If this product is installed damaged, the supplier, nor the retailer, will be responsible
for the costs associated with the repair, replacement, removal or re-installation of
the appliances.
This appliance is not intended for use by person/s (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and/or knowledge. Unless the person has been given supervision
or instruction concerning the use of the appliance by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance, it is not a toy.
Do not install Isodrive motor to a non-Schweigen and/or non-silent rangehood. If you fail to do so, your
warranty will be voided.
The manufacturer declines all responsibility in case of failure to adopt proper safety measures when installing
or using the appliance.
Ensure that the location in which this appliance is installed, has good and permanent ventilation.
Please consult local laws and regulations and install in accordance.
Use an electrical connector with earth that is correct for your location.
Check that the voltage in your area corresponds to the appliance as indicated on the rating label.
Before Installation
We recommend this appliance to be installed or repaired by a qualied Schweigen Home Appliances technician.
Please see our website www.schweigen.com.au for recommended installers.
It is dangerous to modify any part of this appliance. Modication of any kind, will immediately void the warranty.
Electrical Cord
Ensure the supply cord is not exposed to heat, chemicals or sharp objects. If the supply cord is damaged, it must be
replaced by the manufacturer, service agent or a similarly qualied person in order to avoid a hazard. The power
supply cord connection MUST BE installed in such a way that access is easy in case of emergency.
Page 4
2. Your Safety
This guide is for the installation of the Isodrive motor system after the canopy/rangehood has been mounted
on the wall or ceiling. (Refer to canopy/rangehood unit installation manual).
NOTE: All PVC pipe and exi ducting measurements are referring to inside measurements, unless otherwise
mentioned.
Motor Features
• Roof and wall mounting with IPX4 degree of weather protection.
• Super quiet, long vane, backward curved centrifugal fan.
• Airow is dependant on installation and the ducting used. Using single 250mm ex duct, you should attain
up to 3200m
result in a loss of airow.
• Simple installation: mounts onto a 250mm PVC pipe for ultimate strength and allows for easy Dektite roof
sealing.
• Industrial quality motor and fan made in Germany and rated at 40,000 hours.
3
/hr depending on the ducting installation. The use of a smaller than 250mm (ISD) pipe would
• Motor is a high eciency PSC type and rated at 150W costing around the same as two 70W light globes to
run.
• WARRANTY 10 YEARS return to manufacturer. Covers faulty manufacturing or components. It does not
cover normal wear and tear.
General Notes on Installation and Use
This fan unit is designed to be installed using 250mm (OSD) PVC pipe as the initial connection to the fan module.
The fan unit is supplied with a 250mm (OSD) PVC pipe, 250mm (ISD) exible duct. (See page 10 for installation
detail).
2
This fan is suitable for connection to multiple duct runs with a minimum inlet area of 22,000mm
installing, 15 metres of 250mm exi ducting MUST be used and no more than 2 to 3 bends in the exi ducting.
Where possible exible ducting must be extended suciently to present a smooth air passage with bends of at
least the radii of twice the diameter of the duct.
WARNING: The rangehood must not be ducted into a wall cavity or a ceiling space, where a build up of grease
can occur and become a potential re risk. This will void warranty.
NOTE: Fan module and dual foil exi-duct are acoustically matched. Use of semi-rigid or rigid ducting will result
in increased noise and may void warranty. See installation instruction notes ‘Why exi-duct’.
. When
Recommended Installation Distance
Isodrive 3200 motor, recommended 4 to 5 metres of exi ducting.
NOTE: Although less than 4 to 5 metres will increase extraction power this may result in a higher air noise level. Maximum duct length 15 metres (use 250mm ducting), however please be aware that increasing the
duct length above 5 metre will decrease airow. Check with supplier if longer duct length is required. Do
not reduce the duct size at any time and avoid sharp bends.
Page 5
2. Your Safety
Minimum Mounting Height
This fan unit is intended for mounting at a minimum height of 2.1 metres (measured to the lower part of the
fan impeller) above a oor or the ground.
Avoidance of Back Flow
Care should be taken to avoid the back ow of gases into the room from the open ue of gas or other open re
appliances.
Safety of Children
This fan is not intended for use by young children or inrm persons without supervision.
Replacement of supply cord
If the supply cord is damaged, it must be replaced by a service agent or suitably qualied person in order to
avoid a hazard.
Why Flexi-duct
Some internet sites strongly recommend the use of rigid ducting over fully exible ducting. This
may well be the case with conventional rangehoods with internal motor rangehood but not with
external motor rangehood.
Schweigen’s unique Isodrive system works in the opposite way to conventional rangehoods, pulling air through
the hood and acoustically matched ducting, producing almost silent high volume ow. The use of a complete
rigid or semi-rigid ducting system will allow an organ piping eect to occur; like a didgeridoo where a noise is
produced at one end of a hollow rigid pipe and the noise is amplied out the other.
The Isodrive system places the noise outside the house and it needs to be kept there.
WARNING: Installation without the use of at least the minimum recommended length of acoustically matched
exi-ducting in the system will void performance expectations. Any installation problem must be reported
to Schweigen. Call outs relating to incorrect installation will result in a service fee direct to the customer.
Schweigen takes no responsibility for problems caused by faulty installation, this may void warranty. A
preferred installer list can be obtained from Schweigen website www.schweigen.com.au or by calling 1300 881 693.
Page 6
NOTE
For more exible ducting instructions, refer page 19.
3. Description
Isodrive Motor
Included in the box:
1. Isodrive 3200 motor
Approx. 3 metre, 10amp cable and standard male plug
1
2. Fire resistant 250mm OD
NOTE: Cable cut-out at the both ends
3. Flexible ducting (250mm)
Approx. 4 metres, 250mm (260mm OD
4. Flexible ducting (200mm)
Approx. 1.5 metres, 200mm (210mm OD
5. 250-200mm reducer (only use when connecting the Isodrive
3200 motor to a single 200mm opening on a rangehood).
Not included in the box:
• Roof seal kit / Dektite
• Support straps for poly pipe which connects to the
roof truss
Mount 250mm (ISD) rigid PVC pipe securely to beams, trusses or other appropriate structures: refer gure 1.
The pipe should be mounted vertically with the roof penetration being sealed using a Dektite or other appropriate
sealing membrane or device when installing through a metal nished roof. DO NOT install on a over lapping join.
Ensure that the PVC pipe protrudes at least 50mm past the top of the Dektite, checking that the fan assembly
clears the roof cladding at upper edge, refer gure 1.
Pass power cord and plug through mounting ange and pipe, then out the slotted PVC pipe for connection to the
female plug coming from the canopy/rangehood. Refer to gure 1.
Do not insert plug into socket outlet or switch on until installation has been completed. Fit fan module to pipe and
x in position using side locking screw.
Certain external installation congurations may cause audible levels of noise to be heard due to the air being
expelled from the motor. To minimize external noise disturbance you can use between 5 to 15 metres of exi duct
to place the Isodrive motor in an appropriate position.
3
Please be aware that the 3200 motor is capable of expelling air at 3200m
For more information on environmental noise limit and conditions please contact your local Council. We have a list
of recommended installers available on the Schweigen website.
/hr.