Schweigen PKUM1390-6ST, PKGA-600ST, PKKLS-ALBB9ST, PKKLS-ALBW9ST, PKGA-900ST Installation Guide

...
INSTALLATION GUIDE
Isodrive 900
12.2016 / V1.0
www.schweigen.com.au
Welcome
Thank you for purchasing your new Schweigen Isodrive system.
To get the maximum output from this unit, please read through this guide before use and installation.
Please always retain your proof of purchase to aid in any warranty queries.
This appliance and its packaging are produced by processes that minimise waste and respect the environment.
Please help us to continue this eort to protect the environment by using the appliance eciently and dispose of the packaging in a responsible manner.
Page 2
Index
1. Welcome _____________________________________________________________________________________ 2
2. Your Safety
Before Installation ______________________________________________________________________________ 4 Electrical Cord __________________________________________________________________________________ 4 Motor Features ________________________________________________________________________________ 5 General Notes on Installation and Use ____________________________________________________________ 5 Recommended Installation Distance _____________________________________________________________ 5 Minimum Mounting Height ______________________________________________________________________ 6 Avoidance of Back Flow _________________________________________________________________________ 6 Safety of Children ______________________________________________________________________________ 6 Replacement of Supply Cord _____________________________________________________________________ 6 Why Flexi-duct _________________________________________________________________________________ 6
3. Description
Isodrive Motor _________________________________________________________________________________ 7
4. Installation
Roof Installation _______________________________________________________________________________ 9 Wall Installation ________________________________________________________________________________ 10 Flat Roof Installation ___________________________________________________________________________ 12 Through Wall Installation for Isodrive 900 _______________________________________________ 13 Fan Unit Shutter Assembly for Isodrive 900 (Optional) _____________________________________ 14 Twin 200mm Outlet Installation Example _______________________________________________ 15
5. Measurements
Measurements for Isodrive 900 _________________________________________________________________ 16
6. Flexible Duct
Shallow Roof Space _______________________________________________________________ 18 Important Note __________________________________________________________________ 18 Securing Flexible Duct _____________________________________________________________ 19
7. Parts List
Parts List for Isodrive 900 ___________________________________________________________ 20
8. Maintenance
Roof Restoration or Cleaning ________________________________________________________ 22
9. Warranty/Disclaimer ________________________________________________________________________ 23
Page 3
2. Your Safety
RECEIVING YOUR RANGEHOOD
Please read this section thoroughly before attempting to operate the appliance. Inspect your product upon receipt. Any damage or defects MUST be reported
within 48 hours, or no claim will be recognised.
DO NOT INSTALL THIS APPLIANCE IF YOU FIND IT DAMAGED.
If this product is installed damaged, the supplier, nor the retailer, will be responsible for the costs associated with the repair, replacement, removal or re-installation of the appliances.
This appliance is not intended for use by person/s (including children) with reduced physical, sensory or mental capabilities, or lack of experience and/or knowledge. Unless the person has been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance, it is not a toy.
Do not install Isodrive motor to a non-Schweigen and/or non-silent rangehood. If you fail to do so, your warranty will be voided.
The manufacturer declines all responsibility in case of failure to adopt proper safety measures.
Ensure that the location in which this appliance is installed, has good and permanent ventilation.
Please consult local laws and regulations and install in accordance.
Use an electrical connector with earth that is correct for your location.
Check that the voltage in your area corresponds to the appliance as indicated on the rating label.
Before Installation
We recommend this appliance to be installed or repaired by a qualied Schweigen Home Appliances technician.
Please see our website www.schweigen.com.au for recommended installers.
It is dangerous to modify any part of this appliance. Modication of any kind, will immediately void the warranty.
Electrical Cord
Ensure the supply cord is not exposed to heat, chemicals or sharp objects. If the supply cord is damaged, it must be replaced by the manufacturer, service agent or a similarly qualied person in order to avoid a hazard. The power supply cord connection MUST BE installed in such a way that access is easy in case of emergency.
Page 4
2. Your Safety
This guide is for the installation of the Isodrive motor system after the canopy/rangehood or bathroom extraction grill has been mounted on the wall or ceiling. (Refer to canopy/rangehood or bathroom extraction unit installation manual).
NOTE: All PVC pipe and exi ducting measurements are referring to inside measurements, unless otherwise mentioned.
Motor Features
• Roof and wall mounting with IPX4 degree of weather protection.
• Super quiet, long vane, backward curved centrifugal fan.
• Airow is dependant on installation and the ducting used. Using single 200mm ex duct, you should attain up to 900m would result in a loss of airow.
• Simple installation: mounts onto a 150mm PVC pipe for ultimate strength and allows for easy Dektite roof sealing.
3
/hr and depending on the ducting installation. The use of a smaller than 150mm (ISD) pipe
• Industrial quality motor and fan made in Germany and rated at 40,000 hours.
• Motor is a high eciency PSC type and rated at 57W.
• WARRANTY 10 YEARS return to manufacturer. Covers faulty manufacturing or components. It does not cover normal wear and tear.
General Notes on Installation and Use
This fan unit is designed to be installed using 150mm (ISD) PVC pipe as the initial connection duct to the fan module, and is supplied with a 150mm (ISD) PVC pipe to 200mm (ISD) exible duct bell-mouth adaptor.
2
This fan is suitable for connection to multiple duct runs with a minimum inlet area of 22,000mm to 15 metres maximum (check with supplier if longer duct length required). Where possible exible ducting must be extended suciently to present a smooth air passage with bends of at least the radii of twice the diameter of the duct.
WARNING: The rangehood must not be ducted into a wall cavity or a ceiling space, where a build up of grease can occur and become a potential re risk. This will void warranty.
and length up
NOTE: Fan module and dual foil exi-duct are acoustically matched. Use of semi-rigid or rigid ducting will result in increased noise and may void warranty. See installation instruction notes ‘Why exi-duct’.
Recommended Installation Distance
Isodrive 900 motor, recommended 4 to 5 metres of exi ducting.
NOTE: Although less than 4 to 5 metres will increase extraction power this will result in higher noise level.
Maximum duct length 15 metres. Check with supplier if longer duct length is required. Do not reduce the duct size at any time and avoid sharp bends.
Page 5
2. Your Safety
Minimum Mounting Height
This fan unit is intended for mounting at a minimum height of 2.1 metres (measured to the lower part of the fan impeller) above a oor or the ground.
Avoidance of Back Flow
Care should be taken to avoid the back ow of gases into the room from the open ue of gas or other open re appliances.
Safety of Children
This fan is not intended for use by young children or inrm persons without supervision.
Replacement of supply cord
If the supply cord is damaged, it must be replaced by a service agent or suitably qualied person in order to avoid a hazard.
Why Flexi-duct
Some internet sites strongly recommend the use of rigid ducting over fully exible ducting. This may well be the case with conventional rangehoods with internal motor rangehood but not with external motor rangehood.
Schweigen’s unique Isodrive system works in the opposite way to conventional rangehoods, pulling air through the hood and acoustically matched ducting, producing almost silent high volume ow. The use of a complete rigid or semi-rigid ducting system will allow an organ piping eect to occur; like a didgeridoo where a noise is produced at one end of a hollow rigid pipe and the noise is amplied out the other.
The Isodrive system places the noise outside the house and it needs to be kept there.
WARNING: Installation without the use of at least the minimum recommended length of acoustically matched exi-ducting in the system will void performance expectations. Any installation problem must be reported to Schweigen. Call outs relating to incorrect installation will result in a service fee direct to the customer. Schweigen takes no responsibility for problems caused by faulty installation, this may void warranty. A preferred installer list can be obtained from Schweigen website www.schweigen.com.au or by calling 1300 881 693.
Page 6
Isodrive Motor
Included in the box:
1. Isodrive 900 motor (280W x 200H mm approx.) Approx. 3 metre, 10amp cable and standard male plug
1
2. Fire resistant 150mm (160mm OD Note: Cable cut-out at the bottom end only
) PVC riser pipe
3. Description
1
2
3. Flexible ducting
1
Approx. 6 metres, 200mm (210mm OD
) diameter
4. Bell-mouth adopter ring 200mm duct to 150mm riser
Not included in the box:
• Roof seal kit / Dektite
• Support straps for poly pipe which connects to the roof truss
• Aluminium Foil tape
• Hanging Bracket require for wall mount
• Wall Cover Plate (wall mount only)
• Zip ties
3
4
Additional S2 kit for twin 200mm outlet using 900 Isodrive motor:
i. One 150mm x 150mm x 200mm Y joint
ii. Flexible ducting
1
Approx. 3 metre, 200mm (210mm OD
1
OD refers to outside dimension.
) diameter
iii
Page 7
4. Installation
900 motor
Power Cord
150mm PVC Pipe (Locking holes fan end)
Dektite
Bell-mouth Adaptor
NOTE: Prevent any cord bunching by pulling cord through from plug top end
50mm
Pipe protrusion above dektite
Fix fan module using side locking screw
Fit side supports to locate pipe
Strap to supports
Connect to rangehood
Page 8
Connect to power supply
Figure 1 Roof Mount Option
NOTE: Minimum ducting length 4 metres. Fully extend exible ducting, cut to length.
IMPORTANT
For more exible ducting instructions, refer page 22. Shutter assembly for 1600 motor is not shown in the diagram. Weather shield (for 1600 motor only) should be installed to prevent rain/ water entering the unit.
Loading...
+ 16 hidden pages