Page 5
2. Your Safety
Motor Features
• Universal mounting, all position with IPXS degree of weather protection
• Patented anti water intrusion system.
• Acoustic dome with super quiet, long vane, backward curved centrifugal fan.
• Airow is dependant on installation and the ducting used.
• Using a single 150mm exi duct run you should attain 600m
3
/hr depending on the ducting installation.
• Theuseofasmaller125pipewouldresultinalossofairow.
• Simple installation: - Mounts onto a 100mm PVC pipe for ultimate strength and allows for easy
Dektite roof sealing.
• Industrial quality motor and fan made in Germany and rated at 40,000 hours.
• Motor is a high efciency PSC type and rated at 62W, costing around the same as a 60W light
globe to run.
• WARRANTY 2 YEARS return to manufacturer. Covers faulty manufacturing or components. It does
not cover normal wear and tear, chemical or storm damage, etc.
General Notes on Installation and Use
This fan unit is designed to be installed using 100mm PVC pipe as the initial connection duct to the fan
module, and is supplied with a 100mm PVC pipe to 150mm exible duct bell-mouth adaptor.
Ducting runs should be more than 2 metres away from the unit and no more than 4 - 5 metres (check
with supplier if longer duct length required). Flexible ducting must be extended sufciently to present
a smooth air passage with bends of at least the radius of twice the diameter of the duct.
WARNING: The Hi Flow VX120 motor system must not be ducted into a wall cavity or a ceiling space
where a build up of grease can occur and become a potential re risk. This will void your warranty.
NOTE: Fan module and dual foil exi-duct are acoustically matched. Use of semi-rigid or rigid ducting
will result in increased noise and void warranty. See installation instruction notes ‘Why exi-duct’.
Recommended Installation Distance
For Hi Flow VX120 motor, a minimum of 3 metres (approx.) is recommended.
NOTE: Installation closer than these distances may result in higher air noise level. Maximum duct
length 4 - 5 metres. Check with supplier if longer length is required. Do not reduce the duct size at
any time and avoid sharp bends.