Thank you for purchasing this Schweigen BRB700 system.
To get the maximum output from this unit, please read through this operating guide before use
and installation.
The operating guide contains important information on the correct use and maintenance of the unit,
as well as important safety notes. This will ensure your personal safety and the lasting value of your
motor system.
We trust that you will enjoy your new Schweigen BRB700 system.
Please always retain your proof of purchase to aid in any warranty queries.
This appliance and its packaging are produced by processes that minimise waste and respect
the environment.
Please help us to continue this eort to protect the environment by using the appliance eciently
and dispose of the packaging in a responsible manner.
Motor Features ________________________________________________________________________________ 5
General Notes on Installation and Use ____________________________________________________________ 5
Recommended Installation Distance _____________________________________________________________ 5
Minimum Mounting Height ______________________________________________________________________ 6
Avoidance of Back Flow _________________________________________________________________________ 6
Safety of Children ______________________________________________________________________________ 6
Replacement of supply cord _____________________________________________________________________ 6
Why Flexi-duct _________________________________________________________________________________ 6
Please read this section thoroughly before attempting to operate the appliance.
Inspect your product upon receipt. Any damage or defects MUST be reported
within 48 hours, or no claim will be recognised.
DO NOT INSTALL THIS APPLIANCE IF YOU FIND IT DAMAGED.
If this product is installed damaged, the supplier, nor the retailer, will be responsible
for the costs associated with the repair, replacement, removal or re-installation of
the appliances.
1. This appliance is not intended for use by person/s (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and/or knowledge. Unless the person has been given
supervision or instruction concerning the use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance, it is not a toy.
2. Air exhaust must be installed in accordance with local laws.
Before Installation
We recommend this appliance to be installed or repaired by a qualied Schweigen Home Appliances technician.
Please see our website www.schweigen.com.au for recommended installers.
It is dangerous to modify any part of this appliance. Modication of any kind, will immediately void the warranty.
The manufacturer declines all responsibility in case of failure to adopt proper safety measures.
Ensure that the location in which this appliance is installed, has good and permanent ventilation.
Please consult local laws and regulations and install in accordance.
Use an electrical connector with earth that is correct for your location.
Check that the voltage in your area corresponds to the appliance as indicated on the rating label.
Electrical Cord
Ensure the supply cord is not exposed to heat, chemicals or sharp objects. If the supply cord is damaged, it must be
replaced by the manufacturer, service agent or a similarly qualied person in order to avoid a hazard.
Page 4
3. General
This manual is for the installation of the motor systems use for bathroom and general extraction.
Motor Features
• Universal mounting all position with IPX4 degree of weather protection
• Patented anti water intrusion system.
• Acoustic dome with super quiet, long vane, backward curved centrifugal fan.
• Airow is dependant on installation and the ducting used.
3
• Using a single 150mm exi duct run you should attain 600m
• The use of a smaller 125 ducting would result in a loss of airow.
• Simple installation: - Mounts onto a 100mm PVC pipe for ultimate strength and allows for easy
Dektite roof sealing.
• Industrial quality motor and fan made in Germany and rated at 40,000 hours.
• Motor is a high eciency PSC type and rated at 62W.
• WARRANTY 5 YEARS return to manufacturer. Covers faulty manufacturing or components. It does not
cover normal wear and tear.
/hr depending on the ducting installation.
General Notes on Installation and Use
This fan unit is designed to be installed using 100mm PVC pipe as the initial connection duct to the fan module,
and is supplied with a 100mm PVC pipe to 150mm exible duct bell-mouth adaptor.
This fan is suitable for connection to multiple duct runs with a minimum inlet area of 11,000 mm². Ducting runs
should be more than 2 metres away from the unit and no more the 4-5 metres (check with supplier if longer
duct length required). Flexible ducting must be extended suciently to present a smooth air passage with
bends of at least the radii of twice the diameter of the duct.
WARNING: The BRB700 must not be ducted into a wall cavity or a ceiling space, where a build up of grease
can occur and become a potential re risk.
NOTE: Fan module and dual foil exi-duct are acoustically matched. The use of semi-rigid or rigid ducting will
result in increased noise levels and void the warranty. See installation instruction notes ‘Why exi-duct’.
Recommended Installation Distance
For the BRB700 motor system, a minimum of 2-3 metres is recommended.
NOTE: Installation closer than these distances will result in higher noise levels. Maximum duct length
4-5 metres. Check with supplier if longer length is required. Do not reduce the duct size at any time
and avoid sharp bends.
Page 5
3. General
Minimum Mounting Height
This fan unit is intended for mounting at a minimum height of 2.1 metres (measured to the lower part of the
fan impeller) above oor/ground level.
Avoidance of Back Flow
Care should be taken to avoid the back ow of gases into the room.
Safety of Children
This fan is not intended for use by young children or inrm persons without supervision.
Replacement of supply cord
If the supply cord is damaged, it must be replaced by a service agent or suitably qualied person in order
to avoid a hazard.
Why Flexi-duct
Some internet sites strongly recommend the use of rigid ducting over fully exible ducting.
The use of a complete rigid or semi-rigid ducting system will cause an organ piping eect to occur; like a
didgeridoo, where a noise is produced at one end of a hollow rigid pipe and the noise is amplied out the other.
The motor system puts the noise outside the house.
Warning: Installation without the use of at least the minimum recommended length of acoustically matched
exi-ducting will void performance expectations. Any installation problems must be reported to Schweigen.
Call outs relating to incorrect installation will result in a service fee direct to the customer. Schweigen takes
no responsibility for problems caused by faulty installation. Faulty installation may void warranty. A preferred