1. Welcome
Thank you for purchasing this Schweigen BRB700 system.
The operating guide contains important information on the correct use and maintenance of the unit, as well as important safety notes. This will ensure your personal safety and the lasting value of your motor system.
We trust that you will enjoy your new Schweigen BRB700 system.
Please always retain your proof of purchase to aid in any warranty queries.
This appliance and its packaging are produced by processes that minimise waste and respect the environment.
Please help us to continue this eort to protect the environment by using the appliance eciently and dispose of the packaging in a responsible manner.
Page 2
Page 3
Table of Contents
1. Welcome _____________________________________________________________________________________ 2
2. Your Safety
Warning _______________________________________________________________________________________ 4 Before Installation ______________________________________________________________________________ 4 Electrical Cord __________________________________________________________________________________ 4
3. General
Motor Features ________________________________________________________________________________ 5 General Notes on Installation and Use ____________________________________________________________ 5 Recommended Installation Distance _____________________________________________________________ 5 Minimum Mounting Height ______________________________________________________________________ 6 Avoidance of Back Flow _________________________________________________________________________ 6 Safety of Children ______________________________________________________________________________ 6 Replacement of supply cord _____________________________________________________________________ 6 Why Flexi-duct _________________________________________________________________________________ 6
4. Roof Installation
1. Roof Installation _____________________________________________________________________________ 7
2. Eaves Installation ____________________________________________________________________________ 9
3. Wall Installation ______________________________________________________________________________ 10 Optional DVW600 Installation ________________________________________________________ 11
5. Back Draft Shutter System
Back Draft Shutter System Futment to Bell-mouth Adaptor ________________________________________ 12
6. Flexible Ducting
Flexible Ducting ________________________________________________________________________________ 13 Shallow Roof Space ____________________________________________________________________________ 14
7. Maintenance
Roof Restoration or Cleaning ____________________________________________________________________ 16
8. Measurements
Vent __________________________________________________________________________________________ 17 BRB700 Motor _________________________________________________________________________________ 18
9. Warranty / Disclaimer _______________________________________________________________________ 19
Page 3
Page 4
2. Your Safety
WARNING
Please read this section thoroughly before attempting to operate the appliance. Inspect your product upon receipt. Any damage or defects MUST be reported within 48 hours, or no claim will be recognised.
DO NOT INSTALL THIS APPLIANCE IF YOU FIND IT DAMAGED.
If this product is installed damaged, the supplier, nor the retailer, will be responsible for the costs associated with the repair, replacement, removal or re-installation of the appliances.
1. This appliance is not intended for use by person/s (including children) with reduced physical, sensory or mental capabilities, or lack of experience and/or knowledge. Unless the person has been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance, it is not a toy.
2. Air exhaust must be installed in accordance with local laws.
Before Installation
We recommend this appliance to be installed or repaired by a qualied Schweigen Home Appliances technician.
Please see our website www.schweigen.com.au for recommended installers.
It is dangerous to modify any part of this appliance. Modication of any kind, will immediately void the warranty.
The manufacturer declines all responsibility in case of failure to adopt proper safety measures.
Ensure that the location in which this appliance is installed, has good and permanent ventilation.
Please consult local laws and regulations and install in accordance.
Use an electrical connector with earth that is correct for your location.
Check that the voltage in your area corresponds to the appliance as indicated on the rating label.
Electrical Cord
Ensure the supply cord is not exposed to heat, chemicals or sharp objects. If the supply cord is damaged, it must be replaced by the manufacturer, service agent or a similarly qualied person in order to avoid a hazard.
Page 4
Page 5
3. General
This manual is for the installation of the motor systems use for bathroom and general extraction.
Motor Features
• Universal mounting all position with IPX4 degree of weather protection
• Patented anti water intrusion system.
• Acoustic dome with super quiet, long vane, backward curved centrifugal fan.
• Airow is dependant on installation and the ducting used.
3
• Using a single 150mm exi duct run you should attain 600m
• The use of a smaller 125 ducting would result in a loss of airow.
• Simple installation: - Mounts onto a 100mm PVC pipe for ultimate strength and allows for easy
Dektite roof sealing.
• Industrial quality motor and fan made in Germany and rated at 40,000 hours.
• Motor is a high eciency PSC type and rated at 62W.
WARRANTY 5 YEARS return to manufacturer. Covers faulty manufacturing or components. It does not
cover normal wear and tear.
/hr depending on the ducting installation.
General Notes on Installation and Use
This fan unit is designed to be installed using 100mm PVC pipe as the initial connection duct to the fan module, and is supplied with a 100mm PVC pipe to 150mm exible duct bell-mouth adaptor.
This fan is suitable for connection to multiple duct runs with a minimum inlet area of 11,000 mm². Ducting runs should be more than 2 metres away from the unit and no more the 4-5 metres (check with supplier if longer duct length required). Flexible ducting must be extended suciently to present a smooth air passage with bends of at least the radii of twice the diameter of the duct.
WARNING: The BRB700 must not be ducted into a wall cavity or a ceiling space, where a build up of grease can occur and become a potential re risk.
NOTE: Fan module and dual foil exi-duct are acoustically matched. The use of semi-rigid or rigid ducting will result in increased noise levels and void the warranty. See installation instruction notes ‘Why exi-duct’.
Recommended Installation Distance
For the BRB700 motor system, a minimum of 2-3 metres is recommended.
NOTE: Installation closer than these distances will result in higher noise levels. Maximum duct length
4-5 metres. Check with supplier if longer length is required. Do not reduce the duct size at any time and avoid sharp bends.
Page 5
Page 6
3. General
Minimum Mounting Height
This fan unit is intended for mounting at a minimum height of 2.1 metres (measured to the lower part of the fan impeller) above oor/ground level.
Avoidance of Back Flow
Care should be taken to avoid the back ow of gases into the room.
Safety of Children
This fan is not intended for use by young children or inrm persons without supervision.
Replacement of supply cord
If the supply cord is damaged, it must be replaced by a service agent or suitably qualied person in order to avoid a hazard.
Why Flexi-duct
Some internet sites strongly recommend the use of rigid ducting over fully exible ducting.
The use of a complete rigid or semi-rigid ducting system will cause an organ piping eect to occur; like a didgeridoo, where a noise is produced at one end of a hollow rigid pipe and the noise is amplied out the other.
The motor system puts the noise outside the house.
Warning: Installation without the use of at least the minimum recommended length of acoustically matched exi-ducting will void performance expectations. Any installation problems must be reported to Schweigen. Call outs relating to incorrect installation will result in a service fee direct to the customer. Schweigen takes no responsibility for problems caused by faulty installation. Faulty installation may void warranty. A preferred installer list can be obtained from the Schweigen website www.schweigen.com.au or call 1300 881 693.
Page 6
Page 7
Three options for mounting the unit
Roof Mount Option
Mounting Flange
110mm PVC Pipe
Dektite
Slot option
4. Installation
Ensure clearance
100 — 500
Bell-mouth adaptor
Min 90mm long PVC pipe
20
min
20
min
Eave Mount Option
Wall Mount Option
Figure 1 The three options for mounting the unit.
1. Roof Installation
Mount the 100mm rigid PVC pipe securely to the beams, trusses or other appropriate structures, refer gure 1. on the next page.
Bell-mouth adaptor
Electrical connection between rangehood and remote fan module
(Recommended duct length: 2-3 metre)
To fan
Vent
The pipe should be mounted either vertically or perpendicular to the roof cladding with the roof penetration being sealed using a Dektite or other sealing device. Please note Schweigen do not provide any sealing kits.
Ensure that the pipe protrudes at least 80mm past the top of the Dektite, checking that the mounting ange clears the roof cladding at upper edge as shown in gure 1.
The maximum recommended protrusion is 500mm. Fit mounting ange, refer gure 1, to pipe using silicon sealant, then tape in position until sealant has set.
Fit fan module to the mounting ange by placing in position, rotating clockwise to engage bayonet ngers and secure by screwing in locking screw (while holding fan module rmly in the fully clockwise position).
Page 7
Page 8
4. Installation
Roof Clading
Locking Screw
Fan Module
Mounting Flange
Dektite
Slot option
Optional bend
Slot pipe for power cord exit. Cover with ducting tape if required
Bell-mouth adaptor
Roof Frame
110mm PVC Pipe
Secure pipe to structure
150mm exible ducting
5 metre max
Power cord
Figure 3
Page 8
Page 9
4. Installation
2. Eaves Installation
After ensuring sucient clearance exists for the mounting ange and ducting (gure 1), cut a circular hole 165mm Ø, maintaining adequate clearances. The eave sheeting must be reinforced.
Pre-drill mounting ange recess (gure 4).
If access to the eave space is restricted, before xing the mounting ange to the eave, preassemble the mounting ange, PVC pipe, bell-mouth adaptor and exi-duct, then feed up into roof space. Remember to run power cord through the assembly and out the slotted PVC pipe wall (gure 4).
Fit the fan module to mounting ange by placing in position, rotating clockwise to engage bayonet ngers then secure by screwing in locking screw (while holding fan module rmly in the fully clockwise position).
Ensure that one of the three bayonet ngers is accessible for
Roof Frame/Truss
securing locking screw
150mm Ducting
Bell-mouth Adaptor
Roof Cladding
Top Plate
Locking Screw
Eaves
Pre-drill mounting ange recess and secure to reinforced eaves sheet using #8 self tapping screws
Wall
Figure 4
Page 9
Page 10
4. Installation
3. Wall Installation
The installation should be similar to eaves mounting if access to the inside is limited, but if unrestricted. Refer to EAVES INSTALLATION and gure 5.
Min 90mm long PVC pipe
Bell-mouth Adaptor
Flexible 150mm ducting
Min 20mm
NOTE: Ensure that power cord is fed through exit slot and is not allowed to double back restricting fan inlet
Figure 5
Page 10
Page 11
Optional DVK700 Installation
4. Installation
For dual installation, bathroom, toilet or laundry, adjust inlet grilles to balance air ow as required. The strongest extraction should be at the shower, please adjust damper accordingly.
To main power/switch
Additional dual vent kit, Y-branch, 3 metre length exi ducting and inlet grille with adjustable damper (Kit model no: DVK700)
Optional Y-branch
For bathroom installation, locate inlet over or near shower recess
Figure 2 Ventilation Option for Dual Vent
Page 11
Page 12
5. Back Draft Shutter System
Back Draft Shutter System Fitment to Bell-mouth Adaptor
This back draft shutter system cannot be installed in eave type installation.
Vertical Installation
Figure 7 shows an example of vertical installation.
Tape over anges
Bell-mouth adaptor
100mm pipe to fan
To fan
Air ow
Back draft shutter system
Figure 7
Back draft shutter system
IMPORANT
If shutter system
is mounted in the horizontal position, shutter shaft should
be vertical.
Tape over anges
Page 12
Fit exi-duct over shutter assembly
Direction of airow
Part number: 150 MMBDSS
Figure 6
Page 13
6. Flexible Ducting
Flexible Ducting
Flexible ducting must be fully extended and cut to the required length upon installation. Maximum fan performance will not be achieved unless the ducting is fully extended. Failure to fully extend the ducting results in smaller air passage and lower airow. Incorrect installation may reduce airow and increase noise levels. Call outs relating to incorrect installation will result in a service fee directed to the customer. Schweigen will take no responsibility for problems caused by faulty installation. Installation must be carried out by a qualied technician. A preferred installer list can be obtained from Schweigen website www.schweigen.com.au.
Please keep the exi ducting taut, and 2-3 metres in length
NOTE: In shallow roof spaces extend exi ducting horizontally
Reducer 200 to 150mm
IMPORTANT
Please do not crush or kink exible ducting as it will reduce air ow and may cause noise to occur through the system. Ducting must be kept taut at all times.
Page 13
Page 14
6. Flexible Ducting
Shallow Roof Space
In shallow roof spaces, 90 degree elbow PVC joint can be used as a substitute for the bend.
Page 14
Page 15
6. Flexible Ducting
Securing Flexible Duct
Flexible duct must be installed with supports at maximum intervals of 1.5 metres. Flexible ductwork can be supported by using gaer or electrical tape, provided that it does not restrict the internal diameter of the ducting. Ducting installed looped over hanging beams should be installed in such a manner as to ensure the changes of direction are gradual. Support of the ducting with the use of hangers may be required, see option 2.
NOTE: Ducting should be kept taut at all times.
Option 1
Secure the exible duct to the beam
Option 2
Support exible duct by using hangers.
NOTE: Care shall be taken to minimize sagging or snaking of the duct between supports.
Aluminium foil
tape or cable tie
Hanger
Aluminium foil tape or
cable tie
Figure 9 Examples of securing ducting
Page 15
Page 16
7. Maintenance
Roof Restoration or Cleaning
Before roof restoration or cleaning, please completely cover the outside motor system and avoid all chemical contact.
IMPORANT
Any damages caused by the use of chemical products are not covered by warranty.
Figure 10 Avoid chemical contacted to motor system
Page 16
Page 17
8. Measurements
312
Vent
89
312
51.735.8
200
48.4
196 252
Two timber support batons by installer
150mm reducer
194.25mm outlet
Ceilling
251 x 251
Plaster in edge strip
312 x 312
Page 17
Page 18
8. Measurements
BRB700 Motor
370mm
35
29
278
157
110
28
195
35 minimum
Page 18
Page 19
9. Warranty / Disclaimer
Calling the Technical Assistance Service Hotline
In the event that the failure is not due to the faults mentioned in Trouble Shooting, contact Customer Service.
In Australia, Customer Service 1300 829 066
In New Zealand, Customer Service 0800 200 510
Lodging an online Service Request
In the event that failure is not due the reason/s in the trouble shooting section, you can lodge an online Service Request.
To lodge a Service Request, visit our website www.schweigen.com.au/pages/support/service-warranty and click on the link to download the service request form.
A service request will require the following information:
• The purchase date
• The rangehood model and motor type
• The rangehood serial number or batch number (this number is on a sticker inside the rangehood)
• A copy of the purchase receipt (without a receipt your service request cannot be processed)
Faulty Installation
It is not the responsibility of Schweigen Home Appliances to rectify any incorrect installations. A service call out fee will be charged for any Schweigen technician that attends a call, whereby it is established that the fault is due to an incorrect installation or non-manufacturing fault. Should the appliance be installed in such a way that the service agent is unable to gain access to the appliance, the person/s who own the premises where the appliance resides — will be responsible to provide access to the appliance at their expense.
WARRANTY (See insert for more information)
Motor has a 5-Year replacement product warranty. This is a change over warranty. The consumer is responsible for any charges associated with removal of the faulty unit and installation of the new unit. The customer is also responsible for any freight charges incurred in the change over process.
Disclaimer
Under our policy of continuous product development, product specications may change without notice. Prospective purchasers should therefore check with the retailer to ensure this publication correctly describes the products being oered for sale. All information supplied is to be used for general reference purposes only and is on the understanding that Schweigen Home Appliances will not be liable for any loss, liability or damage of whatever kind arising as a result of any reliance upon such information. All pictures used in the guide are for illustrative purposes only.
Page 19
Page 20
SCH00015
Australia 8/3-4 Anzed Court, Mulgrave 3170 Victoria. Phone 1300 881 693
Email sales@schweigen.com.au Web www.schweigen.com.au
New Zealand 5 Tolich Place, Henderson, Auckland 0610. Phone 0800 200 510
Email info.parex@emerson.com Web www.parex.co.nz
Loading...