Schwank MO-2135-SL Schwank Submittal

2100 SUBMITTAL
SD061213
RL: 4A
RD: AUG 2021
SUBMITTAL DATA
bistroSchwank 2100 SERIES
HIGH EFFICIENCY
INFRARED PATIO HEATER
FOR OUTDOOR INSTALLATION
AND HIGH INTENSITY HEATER
FOR NON-RESIDENTIAL INDOOR USE
PROJECT:
ENGINEER:
CONTRACTOR:
DISTRIBUTOR:
SCHWANK MODEL #:
FUEL:
N.G. L.P.G.
APPROVED BY:
DATE:
APPROVAL #:
bistroSchwank 2100 Series is certified by CSA International to:
ANSI Z83.26 / CSA 2.37 Standard for Gas-Fired Outdoor Infrared Patio Heaters
ANSI Z83.19b / CSA 2.35b Standard for Gas-Fired High-Intensity Infrared Heaters
2100 SUBMITTAL
SD061213
RL: 4A
RD: AUG 2021
2
NOTICE:
Schwank reserves the right to make changes to equipment and specifications without obligation or notification.
This publication, or parts thereof, may not be reproduced in any form, without prior written consent from Schwank. Unauthorized use or distribution of this publication is strictly prohibited.
Schwank
5285 Bradco Blvd., Mississauga, Ontario, L4W 2A6
2 Schwank Way
Waynesboro, Georgia, USA 30830
Customer and Technical Services Phone: 1-877-686-3779 Fax : 1-866-361-0523
Email: csr@schwankgroup.com
www.schwankgroup.com
2100 SUBMITTAL
SD061213
RL: 4A
RD: AUG 2021
3
DIMENSIONS / SPECIFICATIONS 2100 SERIES
End View
Front Perspective View
JOB QTY
MODEL
NO.
INPUT
BTUH
GAS
FINISH 1/2” GAS INLET PIPE SIZE
MANIFOLD
PRESSURE
ELECT-
RICAL
WEIGHT
[LBS.]
HIGH
TEMP.
BLACK
MARINE
STAIN-
LESS
MINIMUM
GAS LINE
PRESSURE
MAXIMUM
GAS LINE
PRESSURE
2135-N 35,000 NAT 6” W.C. 14” W.C. 5” W.C.
VOLT-
AGE
24VAC
CUR-
RENT AMPS 40VA*
32
2135-L 35,000 LP 11” W.C. 14” W.C. 10” W.C. 32
2150-N 50,000 NAT 6” W.C. 14” W.C. 5” W.C. 44
2150-L 50,000 LP 11” W.C. 14” W.C. 10” W.C. 44
2152-N
50,000/
36,500
NAT 6” W.C. 14” W.C. 5” W.C. 44
* Transformer required for a multiple heater installation:
The first heater requires 40 VA and each additional heater 20 VA
The sum total will be the required rating of the system or zone Transformer
If total VA required is between transformer rating sizes, select the next higher VA rated transformer.
11”
44”
10.5”
APPROVALS:
The 2100 Series heater has been tested and approved by CSA International:
For Outdoor Use: ANSI Z83.26-CSA 2.37 Gas-fired Outdoor Infrared Patio Heaters
For Indoor Use: ANSI Z83 19-CSA 2 35 Gas-fired High-Intensity Infrared Heaters
MODEL 2152 2-STAGE CONTROL
2-Stage model heater[s] 2152 must be controlled using “OFF-ON-ON” switch sequence. This se-
quence is necessary for heater operation. Schwank offers the following control switch options with brushed stainless steel wall plate:
JM-0201-TS
Control one 2-stage
heater or one zone
of up to 4 heaters.
QUANTITY:
JM-0202-TS
Control two 2-stage
heaters or two zones
up to 4 heaters/zone.
QUANTITY:
JM-0203-TS
Control three 2-stage
heaters or 3 zones up
to 4 heaters/zone.
QUANTITY:
2100 SUBMITTAL
SD061213
RL: 4A
RD: AUG 2021
4
QTY Application MODEL NO
Ends Under Horizontal 30° Angle
E U A S T B F
OUTDOOR 2135 -N\L 14” 45” 13” 14” 9.5” 9” 60”
OUTDOOR 2150 -N\L 14” 60” 16” 19” 20” 8” 62”
OUTDOOR 2152 -N 14” 60” 16” 19” 20” 8” 62”
INDOOR 2135 -N\L 14” 45” 18” 18” 14.5” 11” 60”
INDOOR 2150 -N\L 14” 60” 21” 23” 20” 10” 62”
INDOOR 2152 -N 14” 60” 21” 23” 25” 10” 62”
Note: Ensure mounting height in any location is sufficient to prevent patrons from coming in
contact with heater, and clearance to combustible material is maintained.
MINIMUM CLEARANCE TO COMBUSTIBLES
Notes:
1. The clearance to combustible material represents the minimum distance that must be maintained between the outer heater surface and a nearby surface. The stated clearance to combustibles represents a surface temperature of: Indoor = 90F° [50C°] above room temperature; Outdoor = 117F° [65C°] above ambient temperature.
2. It is the installers responsibility to ensure that building materials with a low heat tolerance which may degrade at lower temperatures are protected to prevent degradation. Examples of low heat tolerance materials include awnings, vinyl siding, fabrics, some plastics, filmy materials, etc.
Do not mount less than 8 ft above floor. Do not store or place anything directly under heater
2100 SUBMITTAL
SD061213
RL: 4A
RD: AUG 2021
5
ITEM 2: WALL MOUNTING KIT
JP-2100-MB
ITEM 3: ARM WALL MOUNTING KIT
JP-2300-MK
ITEM 4: POST MOUNTING KIT
JP-2300-PK
UNIVERSAL
MOUNT
POST MOUNT
ARM WALL MOUNT
WALL MOUNT
Figure 5: MOUNTING OPTIONS
MOUNTING KIT OPTIONS
NOTE: MOUNT HEATER AT MAXIMUM 30° ANGLE TO AVOID DAMAGE
ITEM 1: UNIVERSAL MOUNTING
KIT
JP-2100-CB-K
Also see next page
2100 SUBMITTAL
SD061213
RL: 4A
RD: AUG 2021
6
bistroSchwank 2100 SERIES COMPONENT DESCRIPTION
2135 & 2150 SINGLE-STAGE CONTROL
PATIO CONTROL PANEL 24 VOLT
WIRELESS REMOTE CONTROL
ThermoControl Plus: TC+1 TC+2 TC+4
2152 2-STAGE CONTROL
JM-0201-TS Single Switch Gang 2-Stage Control - 1 Zone - 1 to 4 Heaters
JM-0202-TS Double Switch Gang 2-Stage Control - 2 Zones - 2 to 8 Heaters
JM-0203-TS Triple Switch Gang 2-Stage Control - 3 Zones - 3 to 12 Heaters
IGNITION
SPARK IGNITED PILOT; DIRECT SPARK MODULE: 3 TRIAL IGNITION SEQUENCE; AUTOMATIC SOFT LOCK-OUT WITH AUTO RESET AFTER 30 MINUTES FOR IGNITION RETRIAL
SINGLE-STAGE NATURAL GAS: 5” W.C. MANIFOLD PRESSURE
2135 & 2150 COMBINATION GAS VALVE
SINGLE-STAGE PROPANE: 10” W.C. MANIFOLD PRESSURE
2152 COMBINATION GAS VALVE
TWO-STAGE NATURAL GAS ONLY: 5” / 3.0” W.C. MANIFOLD PRESSURE
WIND SCREEN
2135: ALUMINUM EGG-CRATE
2150, 2152: STAINLESS STEEL EGG-CRATE
CABINET MARINE GRADE 316 STAINLESS STEEL
VENTURI TUBE ALUMINIZED STEEL ASSEMBLED TO BURNER HOUSING
BURNER
SINGLE ATMOSPHERIC BURNER; 3-TRIAL SPARK IGNITED PILOT WITH SOFT LOCKOUT [30 MINUTE RETRIAL CYCLE]; ELECTRONIC FLAME MONITORING / MAINTENANCE SYSTEM
CERAMIC TILE
SCHWANK EFFECT TILE 14/4 WITH SURFACE INDENTATIONS TO IN-
CREASE EMITTING SURFACE AREA, AND HARD FINISHED EDGES
CERAMIC TILE RETAINERS
STAINLESS STEEL
COMBUSTION
TILE SURFACE TEMPERATURE: 1,760°F [960°C] COLD STATECOMBUSTION TRANSFERS HEAT INSTANTANEOUSLY TO TILE SURFACE AND MINIMIZES EMISSIONS:
CO: 10 – 48 ppm, air free [11 – 50 mg/kWh]
NOx: 9 14 ppm, air free [15 – 25 mg/kWh]
Loading...