88884422//8888443
max. R1.5
M3
33.3
33.3
40
3.2
6.2x90˚
50
40
37.5
26.5 6
32.5
+0.2
0
+0.2
0
3
POWER ENTRY MODULES WITHOUT LINE FILTER
IEC Appliance Connector C14 with Fuseholder 2-pole
Plug removal necessary for fuse
replacement
C14
70° C
DDeessccrriippttiioon
n
C18
70° C
- Panel Mount:
Screw-on from front side
- 2 Functions:
Inlet protection class I or II, Fuseholder for fuse-links 5 x 20 mm, 1or 2-pole
- Quick connect terminals 4.8 x 0.8 mm
- We recommend for new applications type 4707
TTeecchhnniiccaall DDaatta
a
Ratings IEC 10 A / 250 VAC; 50 Hz
Ratings UL/CSA 6 A / 250 VAC; 60 Hz
Dielectric Strength > 2 kVAC between L-N
> 4 kVAC between L/N-PE
(1 min/50 Hz)
Allowable Operation Temp. -25 °C to 70 °C
Degree of Protection from front side IP 40 acc. to IEC 60529
Protection Class Suitable for appliances with protection
class I or II acc. to IEC 61140
erminal
T
Quick connect terminals 4.8 x 0.8 mm
Panel Thickness s Screw-on: max 6 mm
Mounting screw torque max 0.5 Nm
Material: Housing Thermoplastic, UL 94V
-0
CChhaarraacctteerriissttiiccs
s
- All single elements are already wired
- With slotted screw type fuseholder
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuse drawer can only be opened with the aid of a tool
The fuseholder is accessible from the equipment front
- Qualified for use in equipment according IEC/EN 60950
WWeebblliinnkks
s
Approvals: http://www.schurter.com/approvals
RoHS: http://www.schurter.com/rohs
Appliance-Inlet /-Outlet C14/C18 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 °C, 10 A, Protection class I or II
Fuseholder 1 or 2 pole, Shocksafe category PC2 acc.
to IEC 60127-6,
for fuse-links 5 x 20 mm
Rated Power Acceptance @ T
23 °C
Power Acceptance @ T
a > 23°C
a
5 x 20: 1.6
pole
Admissible power acceptance at higher
ambient temperatur
W (1 pole)/ 1,2 W (2-pole) per
e see derating curves
DDiimmeennssiioonns
1
www.schurter.com
s
Length 50
mm
88884422//8888443
0 20 40 60 80 100
0.2
0.0
I = < < I
n
I = 0.7 I
n
I = 1.0 I
n
1.6
0.6
0.4
0.8
1.2
1.0
1
.4
0 20 40 60 80 100
0.0
I = < < I
n
I = 0.7 I
n
I = 1.0 I
n
1.2
0.2
0.4
0.8
0.6
1.0
3
POWER ENTRY MODULES WITHOUT LINE FILTER
DDiiaaggrraamms
DDeerraattiinngg ccuurrvvees
s
1-pole
s
2-pole
tance in Watt
tance in Watt per pole
Admissible power accep-
Ambient air temperature Ta °C
VVaarriiaanntts
s
Admissible power accep-
Ambient air temperature Ta °C
Socket and fuse-carrier
PPrrootteeccttiioonn CCllaassss FFuusseehhoollddeerr CCaassee OOrrddeerr NNuummbbeerr
I 1 pole black 0040.5012
I 2-pole black 0040.5000.2
I 2-pole Grey 0040.5001.2
II 2-pole black 0040.5015
PPaacckkaaggiinngg uunniitt
100 Pcs
2