INSTANT POWER™ Jump Starter and DC Power Source
Fuente de Poder de CC y Arrancador
XJS4
XP400
XJS7C
XP750C
XJS5
XP500
DO NOT RETURN THIS PRODUCT TO THE STORE!
Call Customer Service for Assistance: 800-621-5485
¡NO LO DEVUELVA ESTE PRODUCTO A LA TIENDA!
Llame a Servicios al Cliente para Asistencia: 800-621-5485
FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY OR DEATH.
CUALQUIER FALLA PODRÍA RESULTAR EN SERIAS LESIONES O PODRÍA SER MORTAL.
READ THE ENTIRE MANUAL BEFORE USING THIS PRODUCT.
LEA EL MANUAL COMPLETO ANTES DE UTILIZAR ESTE PRODUCTO.
0099001228WB-00
CONTAINS SEALED, NON-SPILLABLE LEAD-ACID
BATTERY. MUST BE DISPOSED OF PROPERLY.
CONTIENE UNA BATERÍA SELLADA DE ÁCIDOPLOMO NO DERRAMABLE QUE DEBE DESECHARSE
APROPIADAMENTE.
WARNING: Possible explosion hazard. Contact with battery acid
may cause severe burns and blindness. Keep out of reach of
children.
ADVERTENCIA: Posible Riesgo de una explosión. El contacto
con una batería de ácido puede causar quemaduras y ceguera.
Manténgase alejado de los niños.
IMPORTANT: READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL.
SAVE THESE INSTRUCTIONS – Charge the Instant Power™ internal battery
immediately after purchase, after every use and every 30 days. This manual will show
you how to use your Instant Power™ safely and effectively. Please read, understand
and follow these instructions and precautions carefully, as this manual contains
important safety and operating instructions. The safety messages used throughout this
manual contain a signal word, a message and an icon.
The signal word indicates the level of the hazard in a situation.
Indicates an imminently hazardous situation which, if not avoided, will result in
death or serious injury to the operator or bystanders.
Indicates a potentially hazardous situation which, if not avoided, could result
in death or serious injury to the operator or bystanders.
Indicates a potentially hazardous situation which, if not avoided, could result
in moderate or minor injury to the operator or bystanders.
Indicates a potentially hazardous situation which, if not avoided, could result
in damage to the equipment or vehicle or property damage.
Pursuant to California Proposition 65, this product contains chemicals
known to the State of California to cause cancer and birth defects or other
reproductive harm. Wash hands after handling.
IMPORTANT SAFETY INSTRUCTIONS – SAVE THESE INSTRUCTIONS. 1.
This manual contains important safety and operating instructions.
RISK OF ELECTRIC SHOCK OR FIRE.
Read the entire manual before using this product. 1.1
Failure to do so could result in serious injury or death.
Keep out of reach of children.1.2
Do not put ngers or hands into any of the Instant 1.3
Power’s™ outlets.
Do not expose the Instant Power™ to rain or snow.1.4
Use only recommended attachments. Use of an attachment not recommended or sold 1.5
by Schumacher® Electric Corporation may result in a risk of re, electric shock or injury
to persons or damage to property.
To reduce the risk of electric shock, unplug the Instant Power™ charger from the outlet 1.6
before attempting any maintenance or cleaning. Simply turning off the controls will not
reduce this risk.
When charging the internal battery, work in a well ventilated area and do not restrict the 1.7
ventilation in any way.
Do not operate the Instant Power™ with damaged cables or clips; have the cable or 1.8 clip replaced immediately by a qualied service person. (Call customer service at
1-800-621-5485.)
Do not operate the Instant Power™ if it has received a sharp blow, been dropped or 1.9
otherwise damaged in any way; take it to a qualied service person. (Call customer
service at: 1-800-621-5485.)
Do not disassemble the Instant Power™; take it to a qualied service person when 1.10
service or repair is required. Incorrect reassembly may result in a risk of re or electric
shock. (Call customer service at: 1-800-621-5485.)
RISK OF EXPLOSIVE GASES.
WORKING IN THE VICINITY OF A LEAD-ACID BATTERY IS 1.11
DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES DURING
NORMAL BATTERY OPERATION. FOR THIS REASON, IT IS OF UTMOST
IMPORTANCE THAT YOU FOLLOW THE INSTRUCTIONS EACH TIME YOU
USE THE INSTANT POWER™.
• 1 •
To reduce the risk of a battery explosion, follow these instructions and those published 1.12
by the battery manufacturer and the manufacturer of any equipment you intend to use
in the vicinity of the battery. Review the cautionary markings on these products and on
the engine.
PERSONAL PRECAUTIONS2.
RISK OF EXPLOSIVE GASES. A SPARK
NEAR THE BATTERY MAY CAUSE A
BATTERY EXPLOSION. TO REDUCE THE
RISK OF A SPARK NEAR THE BATTERY:
NEVER smoke or allow a spark or 2.1
ame in the vicinity of a battery or engine.
Remove personal metal items such as rings, bracelets, necklaces and watches when 2.2
working with a lead-acid battery. A lead-acid battery can produce a short-circuit current
high enough to weld a ring or the like to metal, causing a severe burn.
Be extra cautious, to reduce the risk of dropping a metal tool onto the battery. It might 2.3
spark or short-circuit the battery or other electrical part that may cause an explosion.
Do not permit the internal battery of the Instant Power™ to freeze. Never charge a 2.4
frozen battery.
To prevent sparking, NEVER allow clips to touch together or contact the same piece of metal.2.5
Consider having someone nearby to come to your aid when you work near a 2.6
lead-acid battery.
Have plenty of fresh water and soap nearby in case battery acid contacts your skin, 2.7
clothing or eyes.
Wear complete eye and body protection, including safety goggles and protective 2.8
clothing. Avoid touching your eyes while working near the battery.
If battery acid contacts your skin or clothing, immediately wash the area with soap and 2.9
water. If acid enters your eye, immediately ood the eye with cold running water for at
least 10 minutes and get medical attention right away.
If battery acid is accidentally swallowed, drink milk, the whites of eggs or water. DO NOT 2.10
induce vomiting. Seek medical attention immediately.
PREPARING TO USE THE INSTANT POWER™3.
RISK OF CONTACT WITH BATTERY ACID. BATTERY ACID
IS A HIGHLY CORROSIVE SULFURIC ACID.
Be sure the area around the battery is well ventilated 3.1
while the jump starter is being used.
Clean the battery terminals before using the jump starter. 3.2
During cleaning, keep airborne corrosion from coming into
contact with your eyes, nose and mouth. Use baking soda and water to neutralize the
battery acid and help eliminate airborne corrosion. Do not touch your eyes, nose or mouth.
Add distilled water to each cell until the battery acid reaches the level specied by the 3.3
battery manufacturer. Do not overll. For a battery without removable cell caps, such as
valve regulated lead acid batteries (VRLA), carefully follow the manufacturer’s instructions.
Read, understand and follow all instructions for the Instant Power™, battery, vehicle and 3.4
any equipment used near the battery and Instant Power™. Study all of the vehicle and
battery manufacturer’s specic precautions to be followed while jump starting.
Determine the voltage of the battery by referring to the vehicle owner’s manual and 3.5
make sure that the output voltage of the jump starter is correct.
Make sure that the Instant Power™ cable clips make tight connections.3.6
• 2 •
INSTANT POWER4. ™ LOCATION
RISK OF EXPLOSION AND CONTACT WITH
BATTERY ACID.
Locate the Instant Power™ as far away 4.1
from the battery as the DC cables permit.
Never place the Instant Power™ 4.2
directly above the battery being jumped; gases
from the battery will corrode and damage the Instant Power™.
Do not operate the Instant Power™ in a closed-in area or restrict the ventilation in any way.4.3
FE ATURES5.
XJS4 and XP400
3
1
2
4
5
6
Battery Status Indicators1.
Battery Status Switch2.
Built-In Worklight3.
Worklight ON/OFF Switch4.
12V DC Power Outlet5.
Battery Clips6.
Internal Battery Charger Plug 7.
(not shown)
XJS5 and XP500
1
3
4
6
2
5
8
7
Battery Status Indicators1.
Battery Status Switch2.
Built-In Worklight3.
Worklight ON/OFF Switch4.
12V DC Power Outlet5.
Battery Clips/USB ON/OFF Switch6.
USB Port7.
Battery Clips8.
Internal Battery Charger Plug 9.
(not shown)
XJS7C and XP750C
1
4
2
6
7
3
9
8
5
Battery Status Indicators1.
Battery Status Switch2.
12V DC Power Outlet3.
Battery Clips/USB ON/OFF Switch4.
USB Port5.
Built-In Worklight6.
Worklight ON/OFF Switch 7.
Air Compressor Hose8.
Battery Clips9.
Internal Battery Charger Plug 10.
(not shown)
Air Compressor ON/OFF Switch 11.
(not shown)
Air Compressor Gauge (not shown)12.
Air Compressor Hose Wrap Cleats 13.
(not shown)
Air Compressor Adapters and 14.
Storage Bag (not shown)
• 3 •
CHARGING THE INTERNAL BATTERY OF THE INSTANT POWER™6.
IMPORTANT: CHARGE IMMEDIATELY AFTER PURCHASE, AFTER EACH USE
AND EVERY 30 DAYS TO KEEP THE INSTANT POWER™ INTERNAL BATTERY
FULLY CHARGED.
LED Indicators6.1
To check the internal battery’s status, press the Battery Status button on the front of the
Instant Power™.
The LED lights will indicate the charge level as follows:
A red LED indicates a 50% or less charge, and you should immediately recharge the •
Instant Power™.
A yellow LED indicates a 50 to 75% charge. The Instant Power™ may be used, but •
should be recharged as soon as possible.
A green LED indicates the internal battery is fully charged.•
NOTE: The internal battery’s percent of charge is most accurate when the Instant
Power™ has been disconnected from all devices and charging sources for a few hours.
Charging the Internal Battery using the Built-In Charger6.2
To charge, ip the AC connector on the back of the Instant Power™ up and plug an 1.
18 gauge (AWG) (0.82 mm2) or larger extension cord onto it. (Extension cord not
included; must be purchased separately.)
Plug the other end of the extension cord into a 120V AC electrical wall outlet.2.
The RED LED will light indicating charging.3.
The GREEN LED will light when the battery has reached full charge. This could 4.
take up to 72 hours, due to the age and condition of the battery. The charger will
automatically go into maintain mode and maintain the battery at full charge without
damaging it.
Charge the Instant Power™ as soon as possible after each use.5.
Do not use the Instant Power™ while charging the internal battery.
You may also charge the internal battery while driving, using a male-to-male charger
cable (p/n 94500109 – not included). Insert one end of the charger cable into the 12V
DC power outlet and the other end into the vehicle’s accessory outlet (lighter socket).
Completely disconnect the charger cable when the engine is not running.
during this method of charging. Using this method to charge the battery overrides the
maintain mode and the battery can be overcharged. Monitor the progress of the battery,
and when it reaches a full (100%) charge, disconnect the charger. Do not charge it for
more than four hours and do not leave the battery unattended or it could explode,
causing property damage or personal injury.
OPERATING INSTRUCTIONS7.
Jump Starting a Vehicle Engine7.1
Turn the vehicle’s ignition OFF before making cable connections.1.
Position the DC cables to reduce the risk of damage by the hood, door and moving 2.
or hot engine parts. NOTE: If it is necessary to close the hood during the jump
starting process, ensure that the hood does not touch the metal part of the battery
clips or cut the insulation of the cables.
Stay clear of fan blades, belts, pulleys and other parts that can cause injury.3.
Check the polarity of the battery posts. The POSITIVE (POS, P, +) battery post 4.
usually has a larger diameter than the NEGATIVE (NEG, N, -) post.
The RED LED and the GREEN LED do not indicate charging status
A SPARK NEAR THE BATTERY MAY CAUSE
A BATTERY EXPLOSION. TO REDUCE THE
RISK OF A SPARK NEAR THE BATTERY:
Do not use the Instant
Power™ while charging the
internal battery.
• 4 •
Determine which post of the battery is grounded (connected) to the chassis. If the 5.
negative post is grounded to the chassis (as in most vehicles), see step 6. If the
positive post is grounded to the chassis, see step 7.
For a negative-grounded vehicle, connect the POSITIVE (RED) clip from the jump 6.
starter to the POSITIVE (POS, P, +) ungrounded post of the battery. Connect the
NEGATIVE (BLACK) clip to the vehicle chassis or engine block away from the
battery. Do not connect the clip to the carburetor, fuel lines or sheet-metal body parts.
Connect to a heavy gauge metal part of the frame or engine block.
For a positive-grounded vehicle, connect the NEGATIVE (BLACK) clip from the jump 7.
starter to the NEGATIVE (NEG, N, -) ungrounded post of the battery. Connect the
POSITIVE (RED) clip to the vehicle chassis or engine block away from the battery.
Do not connect the clip to the carburetor, fuel lines or sheet-metal body parts.
Connect to a heavy gauge metal part of the frame or engine block.
RISK OF EXPLOSION.
Models XJS5, XP500, XJS7C and XP750C: If you have connected the clips
backward, an audio alarm will sound. DO NOT turn the ON/OFF switch to the
ON position. This could cause serious damage to the Instant Power™ or the
vehicle. Reverse the connections and the audio alarm will stop.
Turn ON the Jump Start ON/OFF switch. Crank the engine. If the engine 8.
does not start within 5-8 seconds, stop cranking and wait at least 1 minute before
attempting to start the vehicle again. (This permits the battery to cool down.)
After the engine starts, make sure to turn OFF the Jump Start switch. 9.
Then, disconnect the black clip (-) and then the red clip (+), in that order.
Recharge the Instant Power™ as soon as possible after use.10.
RISK OF EXPLOSION.
To prevent sparking, NEVER allow the clips to touch together or to contact the
same piece of metal. Never attempt to jump start a frozen battery.
Powering a 12V DC Device:7.2
The Instant Power™ is a power source for all 12V DC accessories that are
equipped with a 12V accessory plug. Use it for power outages and shing or
camping trips.
Make sure the device to be powered is OFF before inserting the 12V DC accessory plug
into the 12V DC accessory outlet.
Ensure the battery clips are securely clipped on the storage holders.1.
Open the protective cover of the DC power outlet on the front of the Instant Power™.2.
Plug the 12V DC device into the DC power outlet, and turn the 12V DC device on 3.
(if required).
If the 12V DC device draws more than 15A or has a short circuit, the internal 4.
circuit breaker of the Instant Power™ will trip and disconnect the power to the
device. Disconnect the 12V DC device. The breaker will automatically reset after
an overload occurs.
The DC power outlet is wired directly to the internal battery. Extended operation of a 12V
DC device may result in excessive battery drain. Recharge immediately after unplugging
the 12V DC device.
Using the USB Port (Models XJS5, XP500, XJS7C and XP750C)7.3
The USB port provides up to 500mA at 5V DC.
Ensure the battery clips are securely clipped on the storage holders.1.
Turn the Instant Power™ On/Off switch to the ON (clockwise) position.2.
Plug the device into the USB port on the front panel.3.
Turn the USB device on.4.
Reverse these steps when nished using the USB port.5.
Charge the Instant Power™ as soon as possible after using the USB port.6.
Using the Built-In Light7.4
Position the Instant Power™ on a at, stable surface near the intended work area.1.
Ensure the battery clips are securely clipped on the storage holders.2.
• 5 •
Loading...
+ 15 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.