Schumacher INSTANT POWER XP400W,INSTANT POWER XP600,INSTANT POWER XP750W Owner's Manual

0099001407-00
OWNERS MANUAL / MANUAL DEL USUARIO Models / Modelos: XP400W, XP600, XP750W INSTANT POWER
Jump Starter and DC Power Source Arrancador y Fuente de Poder de CC
PLEASE SAVE THIS OWNER’S MANUAL AND READ BEFORE EACH USE.
POR FAVOR GUARDE ESTE MANUAL DEL PROPIETARIO Y LEER ANTES DE CADA USO. En este manual se explica cómo utilizar el Instant Power segura y efectiva. Por favor, lea y siga las siguientes instrucciones y precauciones.
XP400W
XP750W
XP600
THIS UNIT CONTAINS A SEALED, NON-SPILLABLE LEAD-ACID BATTERY. MUST BE DISPOSED OF PROPERLY.
ESTA UNIDAD CONTIENE UNA BATERÍA SELLADA DE ÁCIDO-PLOMO NO DERRAMABLE QUE DEBE DESECHARSE APROPIADAMENTE.
WARNING: Possible explosion hazard. Contact with battery acid may
cause severe burns and blindness. Keep out of reach of children.
ADVERTENCIA: Posible Riesgo de una explosión. El contacto con una batería de ácido puede causar quemaduras y ceguera. Manténgase alejado de los niños.
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS ........................................................................3
PERSONAL SAFETY PRECAUTIONS...........................................................................3
FEATURES ..................................................................................................................... 4
CHARGING THE INTERNAL BATTERY OF THE INSTANT POWER ............................4
USING THE INSTANT POWER ......................................................................................5
MAINTENANCE AND CARE .......................................................................................... 6
TROUBLESHOOTING .................................................................................................... 7
BEFORE RETURNING FOR REPAIRS ..........................................................................7
SPECIFICATIONS ..........................................................................................................8
REPLACEMENT PARTS/ACCESSORIES .....................................................................8
LIMITED WARRANTY ....................................................................................................8
WARRANTY CARD / TARJETA DE GARANTÍA ........................................................... 15
CONTENIDOS
INSTRUCCIONES IMPORTANTES DE SEGURIDAD ...................................................9
PRECAUCIONES DE SEGURIDAD PERSONAL ..........................................................9
CARACTERÍSTICAS ....................................................................................................10
PARA CARGAR LA BATERIA INTERNA DE LA FUENTE DEL INSTANT POWER .....10
CÓMO UTILIZAR EL INSTANT POWER ...................................................................... 11
MANTENIMIENTO Y CUIDADO ................................................................................... 12
LOCALIZACIÓN Y SOLUCIÓN DE PROBLEMAS .......................................................13
ANTES DE DEVOLVER A REPARACIONES ...............................................................13
ESPECIFICACIONES ................................................................................................... 14
REPUESTOS/ACCESORIOS ....................................................................................... 14
GARANTÍA LIMITADA ...................................................................................................14
WARRANTY CARD / TARJETA DE GARANTÍA ........................................................... 15
• 3 •
IMPORTANT SAFETY INSTRUCTIONS
WARNING – RISK OF EXPLOSIVE GASES
WORKING IN THE VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL OPERATION. IT IS IMPORTANT THAT YOU FOLLOW THESE INSTRUCTIONS EACH TIME YOU USE THE INSTANT POWER.
To reduce the risk of battery explosion, follow these instructions and those published by the battery manufacturer and the manufacturer of any equipment you intend to use in the vicinity of a battery. Review cautionary marking on these products and on the engine.
WARNING: Pursuant to California Proposition
65, this product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.
• Keep out of reach of children.
• Do not disassemble the Instant Power.
Take it to a qualied service professional if service or repair is required. Incorrect
assembly may result in re or electrical shock.
• Do not use the Instant Power to jump a vehicle while charging the internal battery.
• Do not recharge the Instant Power with a damaged extension cord.
• The Instant Power gets hot during charging and must have proper ventilation.
• Do not set the Instant Power on ammable
materials, such as carpeting, upholstery, paper, cardboard, etc.
• Place the Instant Power as far away from the battery being jumped as the cables will permit.
• Do not expose the Instant Power to rain or snow.
• Never place the Instant Power directly above battery being jumped.
• To prevent arcing, never allow the clamps to touch together or to contact the same piece of metal.
• Use of an attachment not recommended or sold by Schumacher® Electric Corporation may result in damage to the unit or personal injury.
• Never operate the Instant Power if it is damaged.
• If someone else uses the Instant Power, ensure they are well informed on how to use it safely, and have read and understood the operating instructions.
• The Instant Power is NOT designed to be installed as a replacement for a vehicle battery.
• Use ONLY on vehicles, boats and garden tractors powered with a 12V DC battery system.
• If the engine fails to start after the recommended number of attempts, disconnect the unit and look for other problems that may need to be corrected.
• Use the Instant Power for jump starting lead-acid batteries ONLY. Do not use for dry cell batteries that are commonly used with home appliances.
PERSONAL SAFETY PRECAUTIONS
• Wear complete eye and clothing protection when working near lead-acid batteries. Always have someone nearby for help.
• Have plenty of fresh water, soap and baking soda nearby for use, in case battery acid contacts your eyes, skin, or clothing. Wash immediately with soap and water and seek medical attention.
• If battery acid comes in contact with eyes,
ush eyes immediately for a minimum 10
minutes and get medical attention.
• Neutralize any acid spills thoroughly with baking soda before attempting to clean up.
• Remove all personal metal items from your body, such as rings, bracelets, necklaces and watches. A battery can produce a short circuit current high enough to weld a ring to metal, causing a severe burn.
• Never smoke or allow a spark or ame in
the vicinity of the battery or engine.
• 4 •
FEATURES
1
4
5
6
8
7
3
2
XP600
1. Rotary switch for USB and jump starter
2. Battery status indicators
3. Battery status button
4. USB port
5. Built-in work light
6. Worklight ON/OFF switch
7. 12V DC power outlet
8. Battery clamps
XP750W
1. Air compressor hose
2. USB port
3. Rotary switch for USB and jump starter
4. Built-in work light
5. Battery status indicators
6. Battery status button
7. Worklight ON/OFF switch
8. 12V DC power outlet
9. Battery clamps
10. Air compressor gauge
11. Air compressor ON/OFF switch
12. Internal battery charger port
13. Air compressor hose wrap cleats
14. Air compressor adapters
and storage bag
2
1
5
6
7
9
8
3
4
14
13
10
11
12
XP400W
1. Rotary switch
2. Battery status indicators
3. Battery status button
4. 12V DC power outlet
5. Battery clamps
1
3
2
5
4
CHARGING THE INTERNAL BATTERY OF THE INSTANT POWER
IMPORTANT! CHARGE IMMEDIATELY
AFTER PURCHASE, AFTER EACH USE AND EVERY 30 DAYS, TO KEEP THE INSTANT POWER’S INTERNAL BATTERY FULLY CHARGED AND PROLONG BATTERY LIFE.
CHECKING THE LEVEL OF THE INTERNAL BATTERY
Press the Battery Status button on the front of the unit. The LED lights will indicate the current charge level as follows:
RED – less than 20% of full charge; immediately charge the unit.
YELLOW – 20-80% of full charge. GREEN – more than 80% of full charge. CHARGING THE INTERNAL BATTERY
Charge the internal battery for the Instant Power using an extension cord (not included).
NOTE: Use of an improper extension cord
could result in a risk of re and electric shock.
• 5 •
1. To charge, ip the AC connector on
the back of the unit UP and plug in an 18 AWG or larger extension cord.
2. Plug the extension cord into a 120VAC
electrical wall outlet.
3. While the jump starter is charging, the RED LED will be on. Complete charging may
take up to 72 hours. When the RED LED turns off, the jump starter is ready to use.
4. When the internal battery is fully charged, the charger will automatically go into maintain mode and maintain the battery at full charge without damaging it. When in maintain mode, the GREEN LED will pulse, as long as there is an AC cord connected to the charging port.
5. Charge the jump starter as soon as possible after use.
CHARGING THE INTERNAL BATTERY WHILE DRIVING
You may also charge the internal battery while driving, using a male-to-male charger cable (part number 94500109 – not included).
IMPORTANT: DO NOT CHARGE INTERNAL BATTERY FOR MORE THAN 30 MINUTES OR LEAVE THE BATTERY UNATTENDED. IT COULD EXPLODE, CAUSING PROPERTY DAMAGE OR PERSONAL INJURY.
1. Make sure the car is running.
2. Insert one end of the accessory cable into
the 12V DC power outlet.
3. Insert the other end of the accessory
cable into the vehicle’s accessory outlet (lighter socket).
NOTE: The RED LED does not operate during this method of charging. Using this method to charge the battery overrides the maintain mode and the battery can be overcharged.
4. Monitor the progress of the charge by pressing the Battery Status button on the front of the unit. When the battery is fully charged, disconnect the accessory cable from the Instant Power, then from the lighter socket of the vehicle.
NOTE: Completely disconnect the charger cable when the engine is not running.
USING THE INSTANT POWER
IMPORTANT: Using the Engine Start feature
without a battery installed in the vehicle will damage the vehicle’s electrical system.
1. Turn the ignition OFF.
2. Lay the DC cables away from any
fan blades, belts, pulleys and other moving parts.
3. For a negative-ground vehicle (as in most
vehicles), connect the Instant Power’s POSITIVE (RED) clamp to the POSITIVE (POS, P, +) battery post. Next, connect the NEGATIVE (BLACK) clamp to the vehicle chassis or engine block, away from the battery.
4. For a positive-ground vehicle, connect
the Instant Power’s NEGATIVE (BLACK) clamp to the NEGATIVE (NEG, N, -) battery post. Next, connect the POSITIVE (RED) clamp to the vehicle chassis or engine block away from the battery.
5. Turn the switch to the ON position.
6. Crank the engine for no more than
8 seconds. If the engine does not start, wait 2 minutes before cranking again.
7. After the engine starts, turn the switch to
the OFF position and remove the Instant Power from the battery.
8. Charge the Instant Power.
USING THE USB PORT (Models XP600 and XP750W)
The USB port provides up to 2A at 5V DC.
1. Ensure the battery clamps are securely clipped on the storage holders.
2. Turn the Instant Power ON.
3. Plug your device into the USB port.
4. When nished using the USB port, turn
the switch to the OFF position.
5. Charge the Instant Power.
USING THE WORK LIGHT (Models XP600 and XP750W)
The work light is controlled by a sliding ON/ OFF switch located on the front of the Instant Power. Make sure the lamp is turned OFF when the unit is being recharged or stored.
Position the Instant Power on a at, stable
surface near the intended work area. Ensure the battery clamps are securely
clipped on the storage holders.
POWERING A 12V DC DEVICE
The Instant Power is a power source for all 12V DC accessories that are equipped with a 12V accessory plug. Use it for power
outages and on shing or camping trips.
NOTE: Do not power a 12V device with the Instant Power while charging the internal battery.
Loading...