Schneider Electric Systems Canada OM900 Users Manual

O Series Data Radio User Manual
User Manual
OM900 Data Radio
www.triodatacom.com
Page 1 © Copyright 2007 Trio DataCom Pty. Ltd.
O Series Data Radio – User Manual
Contents
Part A – Preface 3
Part B – O Series Overview 5
Part C – Applications 7
Part D – Module Pinouts 8
Part E – System Planning and Design 10
Selecting Antennas 11
Part F – Mounting and LED Indicators 14
Part G – Specifications 16
Appendix – FCC Approved Antennas 17
Page 2 © Copyright 2007 Trio DataCom Pty. Ltd.
O Series Data Radio – User Manual

Part A – Preface

Part A - Preface

Warranty

All equipment supplied by Trio DataCom Pty Ltd is covered by warranty for faulty workmanship and parts for a period of twelve (12) months from the date of delivery to the customer. During the warranty period Trio DataCom Pty Ltd shall, at its option, repair or replace faulty parts or equipment provided the fault has not been caused by misuse, accident, deliberate damage, abnormal atmosphere, liquid immersion or lightning discharge; or where attempts have been made by unauthorised persons to repair or modify the equipment.
The warranty does not cover modifications to software. All equipment for repair under warranty must be returned freight paid to Trio DataCom Pty Ltd or to such other place as Trio DataCom Pty Ltd shall nominate. Following repair or replacement the equipment shall be returned to the customer freight forward. If it is not possible due to the nature of the equipment for it to be returned to Trio DataCom Pty Ltd, then such expenses as may be incurred by Trio DataCom Pty Ltd in servicing the equipment in situ shall be chargeable to the customer.
When equipment for repair does not qualify for repair or replacement under warranty, repairs shall be performed at the prevailing costs for parts and labour. Under no circumstances shall Trio DataCom Pty Ltd’s liability extend beyond the above nor shall Trio DataCom Pty Ltd, its principals, servants or agents be liable for the consequential damages caused by the failure or malfunction of any equipment.

FCC Compliance Notices

FCC Part 15 Notice
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation.
This device must not be modified in any way or FCC compliance may be void.
FCC Approved Antennas
This device can only be used with Antennas listed in the Appendix of the O Series User Manual. Please Contact Trio Datacom if you need more information or would like to order an antenna.
RF Exposure
To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended. The antenna used for this transmitter must not be co-located in conjunction with any other antenna or transmitter.
MAXIMUM EIRP
FCC Regulations allow up to 36 dBm effective isotropic radiated power (EIRP). Therefore, the sum of the transmitted power (in dBm), the cabling loss and the antenna gain (in dBi) cannot exceed 36 dBm.

Australian Compliance Notices

Important Notice

© Copyright 2007 Trio DataCom Pty Ltd All Rights Reserved
This manual covers the operation of the M Series of Digital Data Radios. Specifications described are typical only and are subject to normal manufacturing and service tolerances.
Trio DataCom Pty Ltd reserves the right to modify the equipment, its specification or this manual without prior notice, in the interest of improving performance, reliability or servicing. At the time of publication all data is correct for the operation of the equipment at the voltage and/or temperature referred to. Performance data indicates typical values related to the particular product.
This manual is copyright by Trio DataCom Pty Ltd. All rights reserved. No part of the documentation or the information supplied may be divulged to any third party without the express written permission of Trio DataCom Pty Ltd.
Same are proprietary to Trio DataCom Pty Ltd and are supplied for the purposes referred to in the accompanying documentation and must not be used for any other purpose. All such information remains the property of Trio DataCom Pty Ltd and may not be reproduced, copied, stored on or transferred to any other media or used or distributed in any way save for the express purposes for which it is supplied.
Products offered may contain software which is proprietary to Trio DataCom Pty Ltd. However, the offer of supply of these products and services does not include or infer any transfer of ownership of such proprietary information and as such reproduction or reuse without the express permission in writing from Trio DataCom Pty Ltd is forbidden. Permission may be applied for by contacting Trio DataCom Pty Ltd in writing.
MAXIMUM EIRP
ACMA Regulations allow up to 30 dBm (1 Watt) of effective isotropic radiated power (EIRP) in the 915MHz license free band and 36 dBm (4 Watts) of EIRP in the 2.4GHz band. Therefore, the sum of the transmitted power (in dBm), the cabling loss and the antenna gain cannot exceed the above stated EIRP limits.
Page 3 © Copyright 2007 Trio DataCom Pty. Ltd.
O Series Data Radio – User Manual
Part B – O Series Overview
Important Notices for Class I, Division 2, Groups A, B, C & D Hazardous Locations
Applies to models OM900-xxxxx-xHx(CSA Marked)
This product is available for use in Class I, Division 2, Groups A, B, C & D Hazardous Locations. Such locations are defined in Article 500 of the US National Fire Protection Association (NFPA) publication NFPA 70, otherwise known as the National Electrical Code and in Section 18 of the Canadian Standards Association C22.1 (Canadian Electrical Code).
The transceiver has been recognised for use in these hazardous locations by the Canadian Standards Association (CSA) International. CSA certification is in accordance with CSA Standard C22.2 No. 213-M1987 and UL Standard 1604 subject to the following conditions of approval:
1. The radio modem must be mounted in a suitable enclosure so that a tool is required to gain access for disconnection of antenna, power and communication cables.
2. The antenna, DC power and interface cables must be routed through conduit in accordance with the National Electrical Codes.
3. Installation, operation and maintenance of the radio modem should be in accordance with the radio modem’s user manual and the National Electrical Codes.
4. Tampering or replacement with non-factory components may adversely affect the safe use of the radio modem in hazardous locations and may void the approval.
WEEE Notice (Europe)
This symbol on the product or its packaging indicates that this product must not be disposed of with other waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact the dealer from whom you originally purchased the product.
Dieses Symbol auf dem Produkt oder seinem Verpacken zeigt an, daß dieses Produkt nicht mit anderer Vergeudung entledigt werden darf. Stattdessen ist es Ihre Verantwortlichkeit, sich Ihre überschüssige Ausrüstung zu entledigen, indem es rüber sie zu einem gekennzeichneten Ansammlungspunkt für die Abfallverwertung elektrische und elektronische Ausrüstung übergibt. Die unterschiedliche Ansammlung und die Wiederverwertung Ihrer überschüssigen Ausrüstung zu der Zeit der Beseitigung helfen, Naturresourcen zu konservieren und sicherzugehen, daß es in gewissem Sinne aufbereitet wird, daß menschliche Gesundheit und das Klima schützt. Zu mehr Information ungefähr, wo Sie weg von Ihrer überschüssigen Ausrüstung für die Wiederverwertung fallen können, treten Sie bitte mit dem Händler in Verbindung, von dem Sie ursprünglich das Produkt kauften.
5. A power connector locking screws as supplied by Trio Datacom
MUST be used.
WARNING EXPLOSION HAZARD

Other Related Documentation and Products

Revision History

Issue 1 May 2007 Initial Release Issue 2 Jun 2007 Minor FCC Modifications Issue 3 Jul 2007 Minor FCC Modifications
Page 4 © Copyright 2007 Trio DataCom Pty. Ltd.
O Series Data Radio – User Manual

Part B – O Series Overview

Definition of O Series Data Radio
Trio O Series industrial strength spread spectrum data radios are the ideal solution for professional serial data communications in wireless point to point or point to multi-point SCADA and telemetry applications when the use of licensed frequencies is not possible or when data throughput requirements are greater than traditional licensed frequency equipment can achieve.
O Series systems can be rapidly deployed as permanent or temporary alternatives to costly cable based circuits. They allow complex networks with extended coverage to be implemented at minimum cost, delivering dependable communications in the most demanding environments.

O Series Product Range

The TRIO O Series comprises the OM900, which operates within the 902-928MHz license free frequency band, and the OM240 that can be configured for use in the 2.4GHz license free bands available throughout the world.
O Series – Features and Benefits
Radio
License free communication in international 2.4GHz and 902-928 MHz ISM frequency bands
Versions suitable for use in most parts of the world
Robust, frequency hopping spread spectrum technology for superior interference immunity
1 Watt transmitter output power – adjustable down to 0.01W
High performance receiver
256kbps over the air data speed
Supports point to point and point to multi-point operation
User selectable master, remote and repeater operation
Collision avoidance for simultaneous polling and spontaneous reporting
Data Modem
Suitable for most industry standard data protocols e.g., MODBUS, DNP3, IEC870-5-101, DF1, etc.
User configurable 1200-115,000 bps asynch RS-232/RS485 port
Fully transparent 3 wire user interface
Intelligent transmitter control
Excellent BER performance
Internal CRC and user-selectable forward error correction
Multiple user configurable security layers including data encryption
Page 5 © Copyright 2007 Trio DataCom Pty. Ltd.
O Series Data Radio – User Manual

Standard Accessories

Part B – O Series Overview
Antennas
These antennas are for use outside North America. See Appendix for FCC approved antennas.
Part Number Description
ANT9AL Antenna Yagi 6 Element 9dBd Alum 850-
930MHz
ANT9SS Antenna Yagi 6 Element 9dBd S/S 850-930MHz
ANT13AL Antenna Yagi 15 Element 13dBd Alum 850-
930MHz
ANT13AL Antenna Yagi 15 Element 13dBd S/S 850-
930MHz
ANT900WHIP Antenna Omni-Dirn Whip TNC - Demo Use 902-
928MHz
ANT915OMNI Antenna Omni-Dirn Unity Gain 902-928MHz
ANT2G4/13A Antenna Yagi Enclosed 13dBd Gain 2.4GHz
ANT2G4/16A Antenna Grid Reflector 16dBd Gain 2.4GHz
ANT2G4/24A Antenna Grid Reflector 24dBd Gain 2.4GHz
ANT2G4WHIP Antenna Omni-Dirn Whip TNC - Demo Use
2.4GHz
ANT2G4OMNI Antenna Omni-Dirn Unity Gain 2.4GHz
ANT2G4/6OM Antenna Omni-Dirn 6dBd Gain 2.4GHz
Note:
Part Number Description
RF Cables and Accessories
RFCAB5M2 5.0m RG-213 type Antenna Feeder Cable
terminated with N type Male Connectors
RFCAB10M 10.0m RG-213 type Antenna Feeder Cable
terminated with N type Male Connectors
RFCAB20M4 20.0m LDF4-50 type (1/2” foam dialectric)
Antenna Feeder Cable terminated with N type Male Connectors
LGHTARRST Lightning Surge Arrestor In-line N Female to N
Female DC<1000MHz
LGHTARRST2 Lightning Surge Arrestor In-line N Female to N
Female 2 to 6GHz
1. Frequencies must be specified at time of order.
Power Supplies
PS13V82A Power Supply 13.8V 2A 240VAC
PS13V82ASW Power Supply Switch Mode 13.8V 2A 110-
240VAC
Page 6 © Copyright 2007 Trio DataCom Pty. Ltd.
Loading...
+ 12 hidden pages