All equipment supplied by Trio DataCom Pty Ltd is covered by
warranty for faulty workmanship and parts for a period of twelve
(12) months from the date of delivery to the customer. During the
warranty period Trio DataCom Pty Ltd shall, at its option, repair
or replace faulty parts or equipment provided the fault has not
been caused by misuse, accident, deliberate damage, abnormal
atmosphere, liquid immersion or lightning discharge; or where
attempts have been made by unauthorised persons to repair or
modify the equipment.
The warranty does not cover modifications to software. All
equipment for repair under warranty must be returned freight paid
to Trio DataCom Pty Ltd or to such other place as Trio DataCom
Pty Ltd shall nominate. Following repair or replacement the
equipment shall be returned to the customer freight forward. If it is
not possible due to the nature of the equipment for it to be returned
to Trio DataCom Pty Ltd, then such expenses as may be incurred
by Trio DataCom Pty Ltd in servicing the equipment in situ shall be
chargeable to the customer.
When equipment for repair does not qualify for repair or
replacement under warranty, repairs shall be performed at the
prevailing costs for parts and labour. Under no circumstances shall
Trio DataCom Pty Ltd’s liability extend beyond the above nor shall
Trio DataCom Pty Ltd, its principals, servants or agents be liable
for the consequential damages caused by the failure or malfunction
of any equipment.
FCC Compliance Notices
FCC Part 15 Notice
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept
any interference received including interference that may cause
undesired operation.
This device must not be modified in any way or FCC compliance
may be void.
FCC Approved Antennas
This device can only be used with Antennas listed in the Appendix
of the O Series User Manual. Please Contact Trio Datacom if you
need more information or would like to order an antenna.
RF Exposure
To satisfy FCC RF exposure requirements for mobile transmitting
devices, a separation distance of 20 cm or more should be
maintained between the antenna of this device and persons during
device operation. To ensure compliance, operations at closer
than this distance is not recommended. The antenna used for this
transmitter must not be co-located in conjunction with any other
antenna or transmitter.
MAXIMUM EIRP
FCC Regulations allow up to 36 dBm effective isotropic radiated
power (EIRP). Therefore, the sum of the transmitted power (in
dBm), the cabling loss and the antenna gain (in dBi) cannot exceed
36 dBm.
This manual covers the operation of the M Series of Digital Data
Radios. Specifications described are typical only and are subject to
normal manufacturing and service tolerances.
Trio DataCom Pty Ltd reserves the right to modify the equipment,
its specification or this manual without prior notice, in the interest
of improving performance, reliability or servicing. At the time of
publication all data is correct for the operation of the equipment
at the voltage and/or temperature referred to. Performance data
indicates typical values related to the particular product.
This manual is copyright by Trio DataCom Pty Ltd. All rights
reserved. No part of the documentation or the information supplied
may be divulged to any third party without the express written
permission of Trio DataCom Pty Ltd.
Same are proprietary to Trio DataCom Pty Ltd and are supplied
for the purposes referred to in the accompanying documentation
and must not be used for any other purpose. All such information
remains the property of Trio DataCom Pty Ltd and may not be
reproduced, copied, stored on or transferred to any other media or
used or distributed in any way save for the express purposes for
which it is supplied.
Products offered may contain software which is proprietary to Trio
DataCom Pty Ltd. However, the offer of supply of these products
and services does not include or infer any transfer of ownership
of such proprietary information and as such reproduction or reuse
without the express permission in writing from Trio DataCom Pty
Ltd is forbidden. Permission may be applied for by contacting Trio
DataCom Pty Ltd in writing.
MAXIMUM EIRP
ACMA Regulations allow up to 30 dBm (1 Watt) of effective
isotropic radiated power (EIRP) in the 915MHz license free band
and 36 dBm (4 Watts) of EIRP in the 2.4GHz band. Therefore, the
sum of the transmitted power (in dBm), the cabling loss and the
antenna gain cannot exceed the above stated EIRP limits.
Important Notices for Class I, Division 2,
Groups A, B, C & D Hazardous Locations
Applies to models OM900-xxxxx-xHx(CSA Marked)
This product is available for use in Class I, Division 2, Groups
A, B, C & D Hazardous Locations. Such locations are defined in
Article 500 of the US National Fire Protection Association (NFPA)
publication NFPA 70, otherwise known as the National Electrical
Code and in Section 18 of the Canadian Standards Association
C22.1 (Canadian Electrical Code).
The transceiver has been recognised for use in these hazardous
locations by the Canadian Standards Association (CSA)
International. CSA certification is in accordance with CSA Standard
C22.2 No. 213-M1987 and UL Standard 1604 subject to the
following conditions of approval:
1. The radio modem must be mounted in a suitable enclosure so
that a tool is required to gain access for disconnection of antenna,
power and communication cables.
2. The antenna, DC power and interface cables must be routed
through conduit in accordance with the National Electrical Codes.
3. Installation, operation and maintenance of the radio modem
should be in accordance with the radio modem’s user manual and
the National Electrical Codes.
4. Tampering or replacement with non-factory components may
adversely affect the safe use of the radio modem in hazardous
locations and may void the approval.
WEEE Notice (Europe)
This symbol on the product or its packaging indicates that this
product must not be disposed of with other waste. Instead, it is
your responsibility to dispose of your waste equipment by handing
it over to a designated collection point for the recycling of waste
electrical and electronic equipment. The separate collection and
recycling of your waste equipment at the time of disposal will help
conserve natural resources and ensure that it is recycled in a
manner that protects human health and the environment. For more
information about where you can drop off your waste equipment
for recycling, please contact the dealer from whom you originally
purchased the product.
Dieses Symbol auf dem Produkt oder seinem Verpacken
zeigt an, daß dieses Produkt nicht mit anderer Vergeudung
entledigt werden darf. Stattdessen ist es Ihre Verantwortlichkeit,
sich Ihre überschüssige Ausrüstung zu entledigen, indem es
rüber sie zu einem gekennzeichneten Ansammlungspunkt
für die Abfallverwertung elektrische und elektronische
Ausrüstung übergibt. Die unterschiedliche Ansammlung und
die Wiederverwertung Ihrer überschüssigen Ausrüstung zu der
Zeit der Beseitigung helfen, Naturresourcen zu konservieren
und sicherzugehen, daß es in gewissem Sinne aufbereitet wird,
daß menschliche Gesundheit und das Klima schützt. Zu mehr
Information ungefähr, wo Sie weg von Ihrer überschüssigen
Ausrüstung für die Wiederverwertung fallen können, treten Sie
bitte mit dem Händler in Verbindung, von dem Sie ursprünglich das
Produkt kauften.
5. A power connector locking screws as supplied by Trio Datacom
MUST be used.
WARNING EXPLOSION HAZARD
Other Related Documentation
and Products
Revision History
Issue 1 May 2007 Initial Release
Issue 2 Jun 2007 Minor FCC Modifications
Issue 3 Jul 2007 Minor FCC Modifications
Trio O Series industrial strength spread spectrum data radios are
the ideal solution for professional serial data communications in
wireless point to point or point to multi-point SCADA and telemetry
applications when the use of licensed frequencies is not possible
or when data throughput requirements are greater than traditional
licensed frequency equipment can achieve.
O Series systems can be rapidly deployed as permanent or
temporary alternatives to costly cable based circuits. They allow
complex networks with extended coverage to be implemented at
minimum cost, delivering dependable communications in the most
demanding environments.
O Series Product Range
The TRIO O Series comprises the OM900, which operates within
the 902-928MHz license free frequency band, and the OM240
that can be configured for use in the 2.4GHz license free bands
available throughout the world.
O Series – Features and Benefits
Radio
• License free communication in international 2.4GHz and
902-928 MHz ISM frequency bands
• Versions suitable for use in most parts of the world
• Robust, frequency hopping spread spectrum technology for
superior interference immunity
• 1 Watt transmitter output power – adjustable down to 0.01W
• High performance receiver
• 256kbps over the air data speed
• Supports point to point and point to multi-point operation
• User selectable master, remote and repeater operation
• Collision avoidance for simultaneous polling and
spontaneous reporting
Data Modem
• Suitable for most industry standard data protocols e.g.,
MODBUS, DNP3, IEC870-5-101, DF1, etc.
• User configurable 1200-115,000 bps asynch RS-232/RS485
port
• Fully transparent 3 wire user interface
• Intelligent transmitter control
• Excellent BER performance
• Internal CRC and user-selectable forward error correction
• Multiple user configurable security layers including data
encryption