Schneider Electric Powerline Communications HE2010FDR2120 User Manual

ILV2010, ILV2110, ILV2120
Head End/Repeater
C
ONTENTS
CHAPTER 1: TECHNICAL SPECIFICATIONS
A: Specifications ILV2010, ILV2110, ILV2120 - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-2
CHAPTER 2: INTRODUCTION
A: About This Guide - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-2
Warnings, Cautions, and Notes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-2 Installation Notes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-2 Disclaimer- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-2 Glossary - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-2 Document History - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-2
:
CHAPTER 3: SAFETY INSTRUCTIONS
A: Safety Precautions- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-2
Safety Symbols and Labels - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-2
CHAPTER 4: HARDWARE INSTALLATION
A: Mounting Recommendations - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-2 B: Coupler Cable Installation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-3 C: Switch - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-5 D: Installation of Mains Supply - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-6
Connection Steps - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-6 E: Top Part Change- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-7 F: Filters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-8
Filter Installation- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-8
Shorting Jumpers - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-9 G: Ethernet Interface - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-10 H: Ventilation Plug - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4- 10 I: Sealing Wire - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-10
CHAPTER 5: STATUS LEDS
A: Status LEDs Functionality - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-2
ILV2010 Status LEDs - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-2
ILV2110 Status LEDs - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-3
ILV2120 Status LEDs - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-5
APPENDIX: COMBINING FILTERS
A: Single Injection Point When Using FDD- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -II
How to Connect Single Injection Point - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -II
ILV2010, ILV2110, ILV2120 Installation Guide ENG PM1065/1 PC1 – 3
:
this page intentionally left blank
– 4
Chapter
1
Technical Specifications
ILV2010, ILV2110, ILV2120 Installation Guide ENG PM1065/1 PC1 1 – 1
Chapter 1: Technical Specifications

A. Specifications ILV2010, ILV2110, IL V2120

Physical Features

Weight Approx 2.5kg Dimensions Approx 190x150x80 mm Material Aluminum Ports & Connectors 1 coupler interface (ILV2010 and ILV2110)
2 coupler interfaces (ILV2120) RJ45 10/100BASE-T RS485 serial port
Status indicators (LEDs) Power, Status, PLC, Eth (ILV2010)

Electrical Characteristics

Power Consumption
Voltage 100-240VAC Frequency 50/60Hz PSD (Power
Spectral Density)
Class of equipment Class II Internal fuse (F1) 250 V (Min.), 2 A T
ILV2110/ILV2010 - Max 10W (+8W with optional active accessories) ILV2120 - Max 17W (+15W with optional active accessories)
- 46dBm/Hz @ 10MHz bandwidth
- 49dBm/Hz @ 20MHz bandwidth
- 50dBm/Hz @ 30MHz bandwidth

Environmental

Ingress Protection (IP) IP54
Operating
Operating environment
Schneider Standard FT15005 Category C2. The climatic conditions of category C2 are in accordance to the conditions defined in IEC 60721-3-3 standard: - 3K3
1 – 2
Relative humidity 10% to 100% non-condensing Ambient operating temperature -25C° to 45C° (ILV2110)
-25C° to 40C° (ILV2120)
-25C° to 55C° in restricted areas according to EN 60950
Storage
Storage environment According to ETS 300 019-1-1 Class 1.1 Relative humidity 5% to 95% non-condensing Temperature -5°C to +45°C
C hapter 1: Technical S pecifications
Transport
Transport environment According to ETS 300 019-1-2 Class 2.3
Relative humidity 95% non-condensing
Temperatu r e -40°C to +70°C, < 30days

CE Approval and labels

EMC
Electrical safety
E N55022 cla s s B E N55024 prE N50412-1 type 1, clas s 2
E N 60950-1:2001 IE C 60950-1:2001
Any changes or modifications not expressly approved by Ilevo could void the user's authority to operate this equipment.
IL V 2010, ILV 2110, IL V 2120 Installation G uide E NG P M1065/1 P C1 1 – 3
Chapter 1: Technical Specifications
this page intentionally left blank
1 – 4
Chapter
Introduction
2
ILV2010, ILV2110, ILV2120 Installation Guide ENG PM1065/1 PC1 2 – 1
Chapter 2: Introduction

A. About This Guide

This guide is intended for service personnel that have completed the Ilevo PLC course. This documentation is valid for
• ILV2010 - PU1071/1 - HE Top
• ILV2110 - PU1067/1 - Time Division (TD) part
• ILV2120 - PU1060/1 - Frequency Division (FD) part
• ILV21xx - PU1069/1 - Bottom part

Warnings, Cautions, and Notes

Throughout this guide, there may be blocks of text ind i ca ted by sym b ols . These blocks are warning, caution and notes, and they are used as follows:
WARNING: A WARNING indicates the potential for bodily harm and tells you how to avoid the problem.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
NOTE: A NOTE indicates important information that helps you make better use of your modems.

Installation Notes

The graphics and screen illustrations shown in this manual may differ from what you see from your system, but the steps still apply.

Disclaimer

Products and corporate names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies, and are used only for identifi­cation or explanation and to the owners’ benefit, without intent to infringe.

Glossary

FD Frequency Division HE Head End HW Hardware PLC Powerline Communication TD Time Division
2 – 2

Document History

Revision Date Remark
A December, 2005 B July, 2006 Added appendix PC1 June, 2007 Minor changes
Loading...
+ 22 hidden pages