FCC ID: 2AUCU-14101Z
IC: 25381-14101Z
CAN ICES-3(B) / NMB-3(B)
** = color code: WH (white), LA (light almond), BK (black), GY (gray) / ** = código de color: WH (blanco), LA (almendra clara), BK (negro), GY (gris) / ** = Code de
couleur : BL (blanc), BE (beige), NO (noir), GR (gris)
Retain for future use. / Conservar para uso futuro. / À conserver pour usage ultérieur.
FeaturesCaracterísticasCaractéristiques
•
Wireless Z-Wave technology
creates a mesh network for
command and control
interoperability with other Z-Wave
compliant controllers and
devices.
Manual and remote on/off control
•
of any connected lighting and
other electrical load.
•
Single pole or 3-way
(multi-location) use with auxiliary
switch SQR50101**Z.
•
Measure the energy usage of the
connected loading, display the
actual consumption (in W) and
the accumulated power used (in
kWh) in the user interface of the
gateway.
•
La tecnología inalámbrica Z-Wave crea
una red de malla para la
interoperabilidad de comandos y
controles con otros controladores y
dispositivos compatibles con Z-Wave.
•Control de encendido/apagado manual
y remoto de cualquier luminaria
conectada y otra carga eléctrica.
Uso unipolar o de 3 vías (ubicación
•
múltiple) con el interruptor auxiliar
SQR50101**Z.
•
•
La technologie sans fil Z-Wave crée un
réseau maillé pour assurer
l’interopérabilité du commandement et
des commandes avec d’autres
télécommandes et dispositifs
compatibles avec Z-Wave.
Télécommande manuelle et à distance
•
dotée de la fonction marche/arrêt pour
contrôler tout éclairage connecté, ainsi
que toute autre charge électrique.
•
Utilisation unipolaire ou à 3 voies
(emplacements multiples) à l’aide de
l’interrupteur auxiliaire SQR50101**Z.
•
NOTE: Please refer to the gateway
NOTA:REMARQUE :
installation manual for energy usage
display and energy measurement
features.
SQR14101**Z Z-Wave Switch, Single Pole Energy Monitoring Specifications
Especificaciones de monitoreo de energía del interruptor Z-Wave SQR14101**Z unipolar
Spécifications relatives au contrôle de la consommation de l’énergie d’un interrupteur SQR14101**Z Z-Wave unipolaire
Voltage / Tensión / Tension120 Vac, 60 Hz / 120 Vca, 60 Hz / 120 V CA, 60 Hz
Incandescent / Incandescente / Ampoules1000 W
LED / LED / DEL5 A
Standard Ballast / Balasto estándar / Ballast standard1200 Va / 1200 Va / 1 200 VA
Resistive / Resistivo / Résistive1800 W (15 A)
Motor / Motor / Moteur1/2 Hp
Operating Temperature / Temperatura de operación / Température de
fonctionnement
Supply Connection / Conexión de alimentación / Raccordement au courant14 AWG
Wireless Type / Tipo inalámbrico / Modèle sans filZ-Wave (Support S2 and SmartStart)
Wireless Frequency / Frecuencia inalámbrica / Fréquence radio908.40 MHz / 908.42 MHz / 916 MHz
1
Suitable for at least 90°C. / Apto para al menos 90 ° C. / Convient pour au moins 90 ° C.
This switch is intended to be used for
non-critical automation activities. It is not
intended to support life, safety, or medical
equipment.
Failure to follow these instructions can
result in personal injury or equipment
damage.
PrecautionsPrecaucionesPrécautions
HAZARD OF ELECTRIC SHOCK, EXPLOSION,
OR ARC FLASH
• Apply appropriate personal protective
equipment (PPE) and follow safe electrical work
practices. See NFPA 70E, NOM-029-STPS or
CSA Z462 or local equivalent.
• This equipment must only be installed and
serviced by qualified electrical personnel.
• Turn off all power supplying this equipment
before working on or inside equipment.
• Always use a properly rated voltage sensing
device to confirm power is off.
• To reduce the risk of overheating and possible
equipment damage, do not install to control a
receptacle, a motor-operated appliance, a
fluorescent lighting fixture, or a
transformer-supplied appliance.
• Use with copper wire only.
• Indoor use only.
• Replace all devices, doors, and covers before
turning on power to this equipment.
Failure to follow these instructions will
result in death or serious injury.
HAZARD OF HEAT AND FIRE DAMAGE
Read all instructions before installation. The
manufacturer will not be held responsible for
product damage resulting from not following
the instructions.
• Wet hands are strictly prohibited.
• Work strictly according to the rated load.
• Do not continue working after
self-disassembly of any nature and damage
of external forces.
Failure to follow these instructions can
result in death, injury, or equipment
damage.
PELIGRO DE DESCARGA ELÉCTRICA, EXPLOSIÓN O
DESTELLO POR ARQUEO
• Utilice equipo de protección personal (EPP) apropiado y
siga las prácticas de seguridad eléctrica establecidas por
su Compañía, consulte la norma 70E de NFPA, NOM029-STPS o CSA Z462 o la norma local equivalente.
• Solamente el personal eléctrico calificado deberá instalar
y prestar servicio de mantenimiento a este equipo.
• Desenergice el equipo antes de realizar cualquier trabajo en él.
• Siempre utilice un dispositivo detector de tensión de valor
nominal adecuad para confirmar la desenergización del
equipo.
• Para reducir el riesgo de sobrecalentamiento y
posibles daños al equipo, no lo instale para controlar
un receptáculo, un electrodoméstico operado por un
motor, un accesorio de iluminación fluorescente o un
electrodoméstico alimentado por un transformador.
• Use solo con conductor de cobre.
• Uso exclusivo en interiores.
• Vuelva a colocar todos los dispositivos, las puertas y las
cubiertas antes de volver a energizar el equipo.
El incumplimiento de estas instrucciones podrá
causar la muerte o lesiones serias.
RISQUE D'ÉLECTROCUTION, D'EXPLOSION OU
ÉCLAIR D'ARC
• Portez un équipement de protection personnelle (ÉPP)
approprié et observez les méthodes de travail électrique
sécuritaire. Voir NFPA 70E, NOM-029-STPS ou CSA Z462
ou aux équivalents applicables dans votre region du monde.
• Seul un personnel qualifié doit effectuer l'installation et
l'entretien de cet appareil.
• Coupez l'alimentation de l'appareil avant d'y travailler.
• Utilisez toujours un dispositif de détection de tension
ayant une valeur nominale appropriée pour vous
assurer que l'alimentation est coupée.
• Afin de réduire le risque de surchauffe et de dommages
possibles aux équipements, ne pas installer un appareil
motorisé, un appareil d’éclairage fluorescent ou un
appareil alimenté par un transformateur pour contrôler
une prise de courant.
• À utiliser avec des fils en cuivre uniquement.
• Pour utilisation à l’intérieur uniquement.
• Replacez tous les dispositifs, les portes et les
couvercles avant de mettre l'appareil sous tension.
Si ces directives ne sont pas respectées, cela
entraînera la mort ou des blessures graves.
WARNING: This product can expose you to
chemicals including Carbon black which is
known to the State of California to cause
cancer, and Bisphenol A (BPA), which is
known to the State of California to cause
birth defects or other reproductive harm. For
more information go to
www.P65Warnings.ca.gov
.
ADVERTENCIA: Este producto puede exponerle a
químicos incluyendo negro de carbón, que son
conocidos por el Estado de California como
causantes de cáncer, y Bisfenol A (BPA), que es
conocido por el Estado de California como
causante de defectos de nacimiento u otros daños
reproductivos. Para mayor información, visite
www.P65Warnings.ca.gov.
AVERTISSEMENT: Ce produit peut vous exposer à
des agents chimiques, y compris noir de carbone,
identifiés par l'État de Californie comme pouvant
causer le cancer, et Bisphénol A (BPA) reconnus par
l'État de Californie comme pouvant causer des
malformations congénitales ou autres troubles de
l'appareil reproducteur. Pour de plus amples
informations, prière de
consulter www.P65Warnings.ca.gov.
Neutral / Tapa de barrera / Couvercle de la cloison
T
Traveler / Intermediario / Terre
G
Ground / Tierra / Mettre à la terre
L
Load / Carga / Charge
H
N
G
L
T
N
G
G
T
N
L
G
Outlet Box /
Caja
de tomacorriente /
Bo
Î
te de sortie
Outlet Box /
Caja
de tomacorriente /
Bo
Î
te de sortie
Wire connector /
Conector de
conductores /
Serre-fils
SQR14101**ZSQR50101**Z
LOAD /
CARGA /
CHARGE
LOAD
HOT
TRAVELER
NEUTRAL
TRAVELENEUTRAL
or
SQWVS14101**Z
SQWVM14101**Z
X Series
Serie X
Série X
XD Series
Serie XD
Série XD
XD Series Multi-gang
Serie XD, múltiples receptáculos
Jumelage multiple série XD
NOTE: ** = color code: WH (white), LA (light almond), BK (black), GY (gray)
NOTA: ** = código de color: WH (blanco), LA (almendra clara), BK (negro), GY (gris)
REMARQUE : ** = code de couleur : BL (blanc), BM (beige métallisé), NR (noir), GS (gris)
Only for installation of XD Series cover plate.
Solo para la instalación de la placa de cubierta de la serie XD.
Uniquement pour l’installation du couvercle de la série XD.
S2-authenticated inclusion method,
based on the gateway’s feature. It is
highly recommended to only select
S2-authenticated or the highest
inclusion method, and deselect other
methods. This ensures the highest
security level during Z-Wave service.
During S2-authenticated inclusion,
users may be asked to scan the QR
code or enter a 5-digit pin code
attached on the device.
A. SmartStart inclusion: The feature
assumes the gateway has
implemented SmartStart. Users
could use the APP of the gateway
or the gateway camera to scan
the QR code on device or on
device package before powering
on the device, and then when the
device is powered on, it shall be
automatically added to the
gateway.
B. Manual inclusion: When the
gateway is in adding mode
(please refer to the instruction of
the Z-Wave gateway for the
operations on gateway itself).
NOTA:REMARQUE :
A.A.
B.B.
Join or leave the Z-Wave network / Spa / Fre
4. Exclusion from a Z-Wave
network: When the gateway is in
removing mode (please refer to
the instruction of the Z-Wave
gateway for the operations on
gateway itself).
5. Remote control: After the device is
included in a Z-Wave gateway, the
gateway can provide control of an
individual device, groups of
devices and scenes, and offers
flexibility in setting up the lighting
control network. Please refer to the
gateway instructions for details.
The wireless range is the effective
distance of remote control and it will
be impacted by the following
conditions:
•
Each wall or obstacle (e.g.,
refrigerator, TV, etc.) between the
remote or Z-Wave switch and the
destination device will reduce the
wireless range.
Brick, tile, or concrete walls block
•
more of the wireless signal than
walls made of wooden studs and
plasterboard (drywall).
•The angle of direction between
the remote or Z-Wave switch and
the destination device will also
impact the wireless range;
normally, placing the Z-Wave
switches face-to-face will get the
best wireless range
Wall-mounted Z-Wave switches
•
installed in metal junction boxes
may suffer a significant loss of
range since the metal box blocks
a large part of the wireless signal.
••
••
••
••
6. Reset to factory defaults:6.6.
Reset to factory defaults / Spa / Fre
3 x quick click + 1 x press > 10 seconds
NOTE:NOTA:REMARQUE :
•
Use this procedure only when the
Z-Wave gateway is missing or
otherwise inoperable.
•
Reset the switch to factory
default settings will set the switch
to not in Z-Wave network state,
delete the association setting and
restore the configuration setting
to the default.
held, the LED will blink quickly for
10 seconds and then the paddle
can be released after the LED
change to solid on, the LED will
blink quickly for 3 seconds when
factory reset succeeds.
Advanced SettingSpaFre
The advanced setting requires an
advanced gateway. Basic gateway
does not support this setting. Users
can do the setting through the
interface of the advanced gateway.
All configuration parameters can be
restored to factory default settings by
the gateway or by manual reset.
Synchronization of load power and
LED indicator /
Sincronización de la alimentación de
carga y el indicador LED /
Synchronisation de l'alimentation de
la charge et de l'indicateur DEL
Valid Value /
Valor válido /
Valeur valide
0 = Power ON, LED OFF /
0 = Alimentación encendida, LED apagado /
0 = Sous tension, DEL éteint
1 = Power ON, LED ON /
1 = Alimentación encendida, LED apagado /
Fre
Default Value /
Valor predeterminado /
Valeur par défaut
Default = 1 /
Spa /
Fre
Association / Asociación / Association
Grouping ID / Id. de
agrupamiento / Code
d'identification de groupe
15
25AssGroupSet: send on/off set command / spa / fre
Maximum No. of Nodes /
Número máximo de
nodos / Nombre maximal
de nœuds
Description / Descripción / Description
Lifeline: send switch reset local notification / spa / fre
StatusReport: on/off status report / spa / fre
PowerReport: power metering report / spa / fre
LED Indication / Spa / Fre
Blue LED flashing
Spa
Fre
Blue LED on / Spa / FreSwitch is turned on (default setting, can be configured). / spa / fre
Blue LED off / Spa / FreSwitch is turned off (default setting, can be configured). / spa / fre
LED blinking slowly for 3 minutes: device not in network / spa / fre
LED blinking fast: adding/leaving network / spa / fre
LED keep on for 1 minute: adding/leaving network successfully / spa / fre
LED blink fast for 3s: factory reset success / spa / fre
SmartStart inclusion taking too long / Spa / FrePower cycle the switch to escalate inclusion. / spa / fre
Inclusion is unsuccessfulMove the switch closer to the gateway and repeat the inclusion operation. / spa / fre.
Federal Communication Commission Interference Statement
The equipment has been tested and found to comply with the limits for a class B Digital Device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This equipment uses, generates and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction, may cause harmful interference to radio communication. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with
minimum distance 20 cm between the radiator and your body.
RF Exposure: A distance of 20 cm shall be maintained between the antenna and users, and the transmitter module may not be co-located with any other transmitter
or antenna.
Non-modification Statement
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
FCC Supplier’s Declaration of Conformity
Model number : SQR14101WHZ, SQR14101LAZ, SQR14101BKZ
Suppliers Name: Schneider Electric
Suppliers Address (USA) : 800 Federal Street Andover, MA 01810 USA
Suppliers Website: www.schneider-electric.us
FCC Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired operation.
ISED Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada
applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
L’appareil ne doit pas produire de brouillage;
L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
This equipment complies with ISED RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated
with a minimum distance of 20 cm between the radiator and any part of your body.
Pour se conformer aux exigences de conformité CNR 102 RF exposition, une distance de séparation d'au moins 20 cm doit être maintenue entre l'antenne de cet
appareil ettoutes les personnes.
Warranty Information / Información importante / Renseignements sur la garantie
Schneider Electric warranties its products to be free of defects in materials and workmanship for a period of two (2) years. There are no obligations or liabilities on the
part of Schneider Electric for consequential damages arising out of or in connection with the use or performance of this product or other indirect damages with
respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation.
Schneider Electric garantiza que sus productos estarán libres de defectos en materiales y mano de obra por un período de dos (2) años. No hay obligaciones ni
responsabilidades por parte de Schneider Electric por daños consecuentes que surjan o estén relacionados con el uso o el rendimiento de este producto u otros
daños indirectos con respecto a la pérdida de propiedad, los ingresos o las ganancias, o al costo de remoción, instalación o reinstalación.
Schneider Electric garantit que ses produits sont exempts de défauts de matériaux et de fabrication pour une période de deux (2) ans. Schneider Electric n’a aucune
obligation ni responsabilité à l’égard des dommages indirects découlant de l’utilisation de ce produit ou en rapport avec celle-ci, ni d’autres dommages indirects
résultant de la perte de biens, de revenus ou de profits, ou des frais de retrait, d’installation ou de réinstallation.
Electrical equipment should be installed,
operated, serviced, and maintained only by
qualified personnel. No responsibility is assumed
by Schneider Electric for any consequences
arising out of the use of this material.
Schneider Electric and Square D are
trademarks and the property of
Schneider Electric SE, its subsidiaries, and
affiliated companies. All other trademarks are
the property of their respective owners.
Schneider Electric USA, Inc.
800 Federal Street
Andover, MA 01810 USA
888-778-2733
www.schneider-electric.us
12
Solamente el personal calificado deberá instalar, hacer
funcionar y prestar servicios de mantenimiento al
equipo eléctrico. Schneider Electric no asume
responsabilidad alguna por las consecuencias
emergentes de la utilización de este material.
Schneider Electric y Square D son marcas comerciales
y propiedad de Schneider Electric SE, sus filiales y
compañías afiliadas. Todas las otras marcas
comerciales son propiedad de sus respectivos
propietarios.
Importado en México por:
Schneider Electric México, S.A. de C.V.
Av. Ejercito Nacional No. 904
Col. Palmas, Polanco 11560 México, D.F.
55-5804-5000
www.schneider-electric.com.mx
Seul un personnel qualifié doit effectuer l’installation,
l’utilisation, l’entretien et la maintenance du matériel
électrique. Schneider Electric n’assume aucune
responsabilité des conséquences éventuelles
découlant de l’utilisation de cette documentation.
Schneider Electric et Square D sont des marques
commerciales et la propriété de Schneider Electric SE,
ses filiales et compagnies affiliées. Toutes les autres
marques commerciales sont la propriété de leurs
propriétaires respectifs.
Schneider Electric Canada, Inc.
5985 McLaughlin Road
Mississauga, ON L5R 1B8 Canada
800-565-6699
www.schneider-electric.ca
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.