HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Disconnect all power before servicing equipment.
Failure to follow these instructions will result in death or serious injury.
RISCHIO DI SCARICA ELETTRICA, ESPLOSIONE O ARCO ELETTRICO
Scollegare l’apparecchio da tutti i circuiti di alimentazione prima di qualsiasi intervento.
Il mancato rispetto di queste istruzioni provocherà morte o gravi infortuni.
RISQUE D'ÉLECTROCUTION, D'EXPLOSION OU D’ARC ELECTRIQUE
Coupez toutes les alimentations avant de travailler sur cet appareil.
Le non-respect de ces instructions provoquera la mort ou des blessures graves.
RISCO DE ELECTROCUSSÃO, DE EXPLOSÃO, OU DE ARCO ELÉCTRICO
Desconecte todas as alimentações antes de manipular o produto.
A não observância destas instruções resultará em morte, ou ferimentos graves.
PELIGRO DE DESCARGA ELÉCTRICA, EXPLOSIÓN O ARCO ELECTRICO
Desconecte todas las alimentaciónes antes de manipular el producto.
Si no se siguen estas instrucciones provocará lesiones graves o incluso la muerte.
可能有触电、 爆炸或者电弧灼伤的危险
在此电力设备 上进行工作时, 请先切断所有电源
若违背这些说明, 则可能会导致严重的人 身伤害甚至死亡
GEFAHR VON ELEKTRISCHEM SCHLAG, EXPLOSION ODER LICHTBOGEN
Vor dem Arbeiten am Gerät alle Spannungsversorgungen abschalten.
Die Nichtbeachtung dieser Anweisungen führt zu Tod oderschwerer Körperverletzung.
Опасность поражением электрическим током, опасность взрыва или вспышки дуги.
Перед обслуживанием или ремонтом убедитесь, что питание отключено.
Несоблюдение этих инструкций приведет к смерти или серьезной травме.
WARNING
RISK OF FIRE OR ELECTRIC SHOCK (FOR CONTACTOR WITH UL HI-FAULT SHORT CIRCUIT CURRENT RATINGS ONLY)
The opening of the branch-circuit protective device may be an indication that a fault current has been interrupted. To reduce the risk of fire or electric shock, current-carrying parts and the other components of the controller should be examined and replaced if damaged.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
W9 1379131 0131 A05 09 - 2012 1/2
3P AC TeSys K contactors are grade 2 according to GB 21518. Maximum power consumption lower than 5.0 VA.
根据GB 21518标准,三极 TeSys K系列交流接触器能效等级为2级,产品最大吸持功率低于5.0 VA
Philips N 2
2
mm
1 X 6,35 2 x 2,28
mm
0.34 .
. .
2.5
Torque / : 7lb-in AWG: 1 x 18min
- Surge suppressor
- Limiteur de surtension
- Uberspannungsbegrenzer
- Limitatore di sovratensione
- Limitador de sobretención
- Limitador de sobretensão
2
mm
0.34...2.5 +
0.34...1.5
mm
0.75
4
2
. . .
mm
0.75...4 +
0.75...4
2
2
mm
1.5 .
. .
4
2 x 14 or 1 x 12 max
c
mm
1.5...4 +
1.5...4
ø 6
L
C
Ø
2
mm
7
C
N.mL mm
0,8
7
Ø
mm
3
LA4 KEp
a
c / a
50 / 1.97 in
W9 1379131 0131 A05
35 / 1.38 in
80 /3.09 in
8x Ø4 mm (6UNC)
35 / 1.38 in
35 / 1.38 in
50 / 1.97 in
4 x Ø 4 mm (6 UNC)
2/2
Loading...