schmersal RSS260,RST-U-2 Operating Instructions Supplementary Sheet

Operating Instructions Supplementary Sheet
47.5
Combination of sensor and actuator
Operating instructions. . . . . . . . . . . . .pages 1 to 2
EN
Translation of the original operating instructions
Aktuální verzi návodu k použití
CS
ve vašem jazyce naleznete na www.schmersal.net.
På www.schmersal.net findes
DA
aktuelle betjeningsvejledninger på EU's officielle sprog.
RSS260 / RST-U-2
Destination and use
The RSS260 safety sensor can be optionally used on safety guards in combination with the RST-U-2 actuators. The operating instructions of the RSS260 is to be considered. When using the combination of RSS260 and RST-U-2 deviating or additional instructions for assembly position and switching distances are listed below.
Warning about misuse
In case of improper use or manipulation of the safety switch­gear, personal hazards or damages to machinery or plant components cannot be excluded when safety switchgear is used. The relevant requirements of the standard ISO 14119 must be observed.
Encontrará el manual de
ES
instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www.schmersal.net.
Il manuale d‘istruzioni aggiornato
IT
nella vostra lingua (lingua ufficiale UE) è scaricabile in Internet all‘indirizzo www.schmersal.net.
U vindt de huidige versie van
NL
de gebruikshandleiding in uw officiële landstaal op het Internet, www.schmersal.net.
O manual de instruções actual,
PT
no seu idioma oficial da UE, encontra-se na nossa página de Internet www.schmersal.net.
Vous trouverez la version
FR
actuelle du mode d’emploi dans votre langue nationale officielle sur l’Internet, www.schmersal.net.
EU公用語で書かれた最新の
JP
取扱説明書は,インターネッ (www.schmersal.net) から ダウンロードできます。
Tutaj znajdziesz aktualną wersję
PL
instrukcji obsługi w Twoim języku na stronie internetowej
www.schmersal.net.
På www.schmersal.net finner
SV
ni de aktuella versionerna av bruksanvisningen på EU’s officiella språk.
Mounting
During fitting, the requirements of ISO 14119 must be observed.
The mounting hole of the RST-U-2 provides a mounting by means M3 countersunk screws (max. tightening torque 0.6 Nm). The active areas of the safety sensor and the actuator have to face each other.
Safety sensor and actuator must be permanently fitted to the safety guards and protected against displacement by suitable measures (tamperproof screws, gluing, drilling of the screw heads).
A 1.2mm pin into the rear hole of the RST-U-2 prevents twisting, if this cannot be excluded otherwise by mounting.
Dimensions
All measurements in mm.
Safety sensor RSS260
1910.5
103007762 / B / 2015-06-19 / AE-Nr. 4827
Actuator RST-U-2
¤6
¤1.2
3
EN
16.5
22
39.2
22
15
M3
9
4
18
7
4
Operating Instructions Supplementary Sheet Combination of sensor and actuator
RSS260 / RST-U-2
EN
Y
Y [mm]
S [mm]
12
X [mm]
S [mm]
Actuating directions
Axial misalignment
Actuation from front
4
12
Actuation from side
2
Lateral actuation only from the shown sensor side
Switching distances to IEC 60947-5-3:
Actuation From front From side
Typical switching distance: 12 mm 9 mm Assured switching distance s
- in the temperature range -10 °C ... +60 °C
- in the temperature range -25 °C ... +65 °C Assured switch-off distance s
9
:
ao
: 18 mm
ar
10 mm
8 mm
6 mm 4 mm
The axial misalignment (Y) is max. ± 18 mm. The height misalignment (X) is max. ± 8 mm. Avoid area of side lobes if lateral activated.
X
Actuating curves
The actuating curves represent the typical switching distance of the safety sensor during the approach of the actuator subject to the actuating direction
Transverse misalignment Height misalignment
10
5
0
-5-20 51015-1520-10 0
Preferred actuation directions: from front or from side In case of a lateral actuation, the switching distances are reduced by approx. 3 mm.
12 10
5
0
-5-20-24 51015-15 20 24-10 0
K. A. Schmersal GmbH & Co. KG
Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal
Comprehensive quality insurance to 2006/42/EC
Schmersal is a certified company to appendix X of the Machinery Directive. As a result, Schmersal is entitled to autonomously conduct the conformity assessment procedure for this combination of products listed in Appendix IV of the MD without involving a notified body.
More technical information can be found in the Schmersal online catalog on the Internet at www.schmersal.net.
Phone: +49 - (0)2 02 - 64 74 - 0 Telefax: +49 - (0)2 02 - 64 74 - 1 00 E-Mail: info@schmersal.com Internet: http://www.schmersal.com
2