BZ 16
1 About this document
1.1 Function
This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operati­on and disassembly of the safety switchgear. The operating instructions must be available in a legible condition and a complete version in the vicinity of the device.
1.2 Target group: authorised qualied personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation.
The machine builder must carefully select the harmonised standards to
be complied with as well as other technical specications for the selec­tion, mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information.
Content
1 About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualied personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2 Product description
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.5 Safety classication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3 Mounting
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.3 Axial misalignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.4 Actuation from side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4 Electrical connection
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . . 3
4.2 Contact variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
5 Set-up and maintenance
5.1 Functional testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
5.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6 Disassembly and disposal
6.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
6.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Caution: Failure to comply with this warning notice could lead to failures or malfunctions. Warning: Failure to comply with this warning notice could lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure the proper functionality of the entire machinery or plant.
The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufac­turer. Detailed information regarding the range of applications can be found in the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating instruc-
tions manual, the country-specic installation standards as well as all
prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet: www.
schmersal.net.
The information contained in this operating instructions manual is provi-
ded without liability and is subject to technical modications.
If multiple safety components are wired in series, the Perfor­mance Level to EN ISO 13849-1 will be reduced due to the
restricted error detection under certain circumstances. The
entire concept of the control system, in which the safety com­ponent is integrated, must be validated to EN ISO 13849-2.
KAS / 03.2010 / 1169410-EN
7 Appendix
7.1 EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
There are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
EN
1
Operating instructions Safety sensor BZ 16
1.6 Warning about misuse
In case of inadequate or improper use or manipulations of the safety switchgear, personal hazards or damages to machi-
nery or plant components cannot be excluded. The relevant
requirements of the standard EN 1088 must be observed.
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual. The manufacturer shall accept no liability for damages resul­ting from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary re­pairs, conversions and modications to the device are strictly forbidden;
the manufacturer shall accept no liability for damages resulting from
such invasive work, arbitrary repairs, conversions and/or modications
to the device.
2 Product description
2.1 Ordering code
This operating instructions manual applies to the following types:
➀ ➁
BZ 16­No. Option Description
11 1 NO contact / 1 NC contact
02 2 NC contacts
Actuating planes:
D cover-side U bottom V front side
2.2 Special versions
For special versions, which are not listed in the order code below 2.1, these specications apply accordingly, provided that they correspond to
the standard version.
Cable entry: 3 x M20 Operating principle: non-contact, with coded actuator Actuating magnet: BZ 16-B1, coded
s
: 10 mm minimum distance 2 mm in case
ao
of approach from side
: 20 mm (minimum distance 2 mm in case
s
ar
of approach from side) Hysteresis: approx. 6 mm Repeat accuracy R: < 1 mm I
: 160 mA / 24 VDC ±15 % (polarity reversal)
e/Ue
No-load current: ≤ 70 mA Max. fuse rating: 0.25 A (slow blow) Outputs: 2 enabling paths 2 NC or 1 NC / 1 NO Switching voltage: max. 250 VAC Switching current: max. 4 A Switching capacity: max. 1000 W Required short-circuit
100 A
current: Voltage drop: see Contact resistance Max. fuse rating: 4 A gG D-fuse Utilisation category: AC-15: 230 V / 3 A
DC-13: 24 V / 4 A Power consumption: < 4 W
: 250 VAC
U
i
Overvoltage category: III Degree of pollution: 3 U
: 4 kV
imp
Max. switching frequency: 1 Hz Duration of risk: < 200 ms Ambient temperature: 0 °C … + 55 °C
Storage and transport
- 20 ºC … + 70 °C temperature: Resistance to shock: 30 g / 11 ms Resistance to vibrations: 10...55 Hz, amplitude 1 mm Mechanical life: 50 million operations Contacts: AgSnO, self-cleaning, positive drive Contact resistance: 100 mΩ in new state
2.3 Destination and use
The safety sensor is designed for application in safety circuits and is
used for monitoring the position of movable safety guards to EN 1088 and IEC 60947-5-3. To actuate the safety sensors, only the BZ 16-B1 actuator can be used, conventional magnets are not suitable.
The safety switches are used for applications, in which the hazardous
situation is terminated without delay when the safety guard is opened.
Actuating planes
2.4 Technical data
Standards: IEC 60947-5-3, BG-GS-ET-14 Design: rectangular Enclosure: glass-bre reinforced thermoplastic,
self-extinguishing
Protection class: IP 67 to EN 60529 Termination: Screw terminals Cable section: max. 2 x 1.5 mm
2
(including conductor ferrules)
2.5 Safety classication
Standards: EN ISO 13849-1, EN 62061,
IEC 60947-5-3 PL: up to e Control category: up to 4 PFH value: 4.73 x 10
-8 /
h
Applicable for applications with up to max.
100,000 switching cycles/year (NC/NC
version) or 50,000 switching cycles/year
(NO/NC version) and with max. 250 mA
contact load. Diverging applications upon
request. SIL: up to 3 Service life: 20 years Classication: PDF-M
3 Mounting
3.1 General mounting instructions
Fitting is only authorised in a de-energised condition
Do not use the sensor and the actuator as a mechanical backstop
• Any mounting position, provided that the active surfaces are opposite
• Inseparably x the safety sensor and the actuator to the safety guard (the mounting dimensions are indicated on the back of the enclosure)
• Fix the safety sensor and the actuator onto a at surface
• Do not install the sensor and the actuator in strong magnetic elds
• If possible, do not mount the sensor and the actuator on ferromagne-
tic material
Do not subject the components to extreme vibrations
Keep away from metal chips
Mounting distance between two sensors should always be at least
10 mm
2
EN
Operating instructions
1211 2221
24VDC
Safety sensor
BZ 16
4 Electrical connection
During tting of the actuator and the sensor, the require­ments of DIN EN 1088, especially points 5.2 and 5.7 must be
observed! Please make sure that the actuating elements or the spare actuators are not accessible to prevent tampering.
Protect the BZ 16-B1 actuator against unauthorised removal e.g. by means of tamper-proof screws, rivetting, etc.
3.2 Dimensions
All measurements in mm.
60
20
39
26
37
90
M20 x 1,5
9 17
3.3 Axial misalignment
A horizontal and vertical misalignment of the safety sensor and the actuator is tolerated. The possible misalignment depends on the dis­tance of the active surfaces of the sensor and the actuator. The sensor remains active within the tolerance range.
The specied switching distances refer to opposedly mounted safety
sensors and actuators.
3.4 Actuation from side
In case of an actuation of the sensor from side, a minimum distance of s = 2 mm must be observed between the actuator and the sensor (see gure). To ensure a safe switch-off, the distance between the safety sensor and the actuator must be at least 20 mm (sar) or higher (opening width of the safety guard). The safety sensor and the actuator must be installed with a minimum lateral misalignment of ± 3 mm.
40
52
8
M5
7
M20 x 1,5
40
M20 x 1,5
assured switching distance:
sao = 10 mm
Assured switch-off distance sar = 20 mm
4.1 General information for electrical connection
The electrical connection may only be carried out by autho­rised personnel in a de-energised condition.
The safety sensors must be wired in accordance with the specied
wiring diagram.
4.2 Contact variants
The contact position shows the actuated sensor function when the safety guard is closed.
Inductive loads (e.g. contactors, relays, etc.) are to be provided with
suitable interference suppression circuitry.
2 NC contacts 1 NO contact / 1 NC contact
+
-
BZ 16-02D BZ 16-02U BZ 16-02V
After the safety sensor is wired, open and close the safety guard to
check whether the enabling signal is given.
5 Set-up and maintenance
5.1 Functional testing
The safety function of the safety components must be tested. The
following conditions must be previously checked and met:
1. Fitting of the sensor and the actuator
2. Fitting and integrity of the power cable
3. The system is free of dirt and soiling (in particular metal chips)
5.2 Maintenance
In the case of correct installation and adequate use, the safety sensor
features maintenance-free functionality.
A regular visual inspection and functional test, including the following steps, is recommended:
• Check the tting of the sensor and the actuator
Remove possible metal chips
Check the cable for damage
Damaged or defective components must be replaced.
6 Disassembly and disposal
6.1 Disassembly
The safety switchgear must be disassembled in a de-energised condi­tion only.
BZ 16-11D BZ 16-11U BZ 16-11V
6.2 Disposal
The safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations.
EN
3
Operating instructions Safety sensor BZ 16
7 Appendix
7.1 EC Declaration of conformity
EC Declaration of conformity
Translation of the original declaration of conformity
We hereby certify that the hereafter described safety components both in its basic design and construction conform to the applicable European Directives.
Name of the safety component / type: BZ 16
Description of the safety component: Safety sensor with integrated
Harmonised EC-Directives: 2006/42/EC EC-Machinery Directive
Used harmonized standards: EN 60204-1
Person authorized for the compilation of the technical documentation:
Notied body for the prototype test: Berufsgenossenschaft Feinmechanik /
EC- test certicate: xxxxxxxxxxxxxxx
K.A. Schmersal GmbH
Industrielle Sicherheitsschaltsysteme Möddinghofe 30 ▪ 42279 Wuppertal
Germany
Internet: www.schmersal.com
safety-monitoring module
2004/108/EC EMC-Directive
EN 61000-6-1
EN 61000-6-2
Ulrich Loss Möddinghofe 30 42279 Wuppertal
Elektrotechnik
Gustav-Heinemann-Ufer 130 50968 Cologne ID n°: 0340
EN 61000-6-3
EN 61000-6-4
IEC 60947-5-3
Place and date of issue:
BZ 16-B-EN
Note
The currently valid declaration of conformity can be downloa­ded from the internet at www.schmersal.net.