6 Disassembly and disposal
6.1 Disassembly...........................................4
6.2 Disposal ..............................................4
7 EU Declaration of conformity
1. About this document
1.1 Function
This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the safety switchgear. The operating instructions must be available in a legible condition and a complete version in the vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must be carried out by trained specialist personnel, authorised by the plant operator only.
Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation.
Content
1 About this document
1.1 Function ..............................................1
1.2 Target group: authorised qualied personnel ..................1
1.3 Explanation of the symbols used ...........................1
1.4 Appropriate use ........................................1
1.5 General safety instructions ...............................1
1.6 Warning about misuse ...................................2
1.7 Exclusion of liability .....................................2
2 Product description
2.1 Ordering code .........................................2
2.2 Special versions........................................2
2.3 Destination and use .....................................2
2.4 Technical data .........................................2
2.5 Safety classication .....................................2
3 Mounting
3.1 General mounting instructions .............................3
3.2 Dimensions ...........................................3
3.3 Axial misalignment......................................4
3.4 Adjustment............................................4
4 Electrical connection
4.1 General information for electrical connection..................4
4.2 Contact variants........................................4
4.3 Connector plug.........................................4
The machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selection, mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could lead to failures or malfunctions. Warning: Failure to comply with this warning notice could lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine. It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer. Detailed information regarding the range of applications can be found in the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating instructions manual, the country-specific installation standards as well as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: www.schmersal.net.
x.000 / 04.2016 / v.A. - 101119995-EN / N / 2016-04-20 / AE-Nr. 6009
5 Set-up and maintenance
5.1 Functional testing.......................................4
5.2 Maintenance ..........................................4
The information contained in this operating instructions manual is provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and maintenance are observed.
EN
1
Operating instructions Safety sensor
BNS 300
EN
MT
Bdxxhs/h3600
0,1 x n
op
t
cycle
1.6 Warning about misuse
In case of improper use or manipulation of the safety switch­gear, personal hazards or damages to machinery or plant components cannot be excluded when safety switchgear is used. The relevant requirements of the standard ISO 14119 must be observed.
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual. The manufacturer shall accept no liability for damages result­ing from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary re­pairs, conversions and modifications to the device are strictly forbidden; the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device.
2. Product description
2.1 Ordering code
This operating instructions manual applies to the following types:
BNS 300-01ZG-➀­No. Option Description
ST integrated connector 2211 increased switching distance
2230 supplementary signalling output 2334 increased switching distance and
2246 U
2.2 Special versions
For special versions, which are not listed in the order code below 2.1, these specifications apply accordingly, provided that they correspond to the standard version.
2.3 Destination and use
The safety sensor is designed for application in safety circuits and is used for monitoring the position of movable safety guards to ISO 14119 and IEC 60947-5-3. To actuate the safety sensors, only the BPS 300, BPS 303 or BPS 303 SS actuators can be used, conventional magnets are not suitable.
The safety switchgears are classified according to ISO 14119 as type 4 switching devices.
The safety switches are used for applications, in which the hazardous situation is terminated without delay when the safety guard is opened.
Only the entire system consisting of the safety sensor (BNS 300 with integrated safety-monitoring module) and the actuator (BPS 300/ BPS 303 or BPS 303 SS) meets the requirements of the standard IEC 60947-5-3.
connecting cable
supplementary signalling output
42 VAC
e
2.4 Technical data
Standards:
IEC 60947-5-3, BG-GS-ET-14
Enclosure: glass-fibre reinforced thermoplastic Tightening torque: max. 300 Ncm, A/F 36 Protection class: IP67 to IEC 60529 Degree of pollution: 3 Termination: cable Boflex 4 x 0.75 mm²,
connector M12 x 1, 4-pole;
- ordering suffix -2230:
cable YSLYÖ-0 5 x 0.75 mm²
Operating principle: magnetic Actuator: BPS 300, BPS 303, BPS 303 SS, coded Coding level according to ISO 14119: low Switching distances:
- Assured switching distance s
: 5 mm,
ao
8 mm (ordering suffix -2211/-2334)
- Assured switch-off distance s
: 15 mm,
ar
18 mm (ordering suffix -2211/-2334)
Operating voltage:
24 VDC +10 %/–15 %
ordering suffix -2246: 42 VAC
Operating current: Rated impulse withstand voltage U
30 mA
: 4 kV
imp
Rated insulation voltage Ui: 250 VAC / 30 VDC Required short-circuit current: 100 A Output: 1 enabling path Switching voltage: max. 250 VAC Load current: max. 3 A Switching capacity: max. 750 VA Max. fuse rating: 3 A gG D-fuse to IEC 60269-1 Supplementary signalling contact: max. 100 mA Ambient temperature: −25 °C ... +55 °C Storage and transport temperature: −25 °C ... +70 °C Max. switching frequency: 5 Hz Resistance to shock: 30 g / 11 ms Resistance to vibration: 10 ... 55 Hz, amplitude 1 mm EMC rating: according to EN 61000-6-2
2.5 Safety classification
Standards:
ISO 13849-1
Intended structure:
- 1-channel usage: useable to cat.1 / PL c
for max. 5 million of switching cycles / year for
sensor and for MTTF
B
value for safety contact:
10d
- at 100% contact load:
400,000
≥ 40 years for safety contact
d
- at 80% contact load: 1,000,000
- at 60% contact load: 2,500,000
- at 40% contact load: 7,500,000
- at 20% contact load: 20,000,000 Service life: 20 years
TF
d
10d op op
n
op
(Determined values can vary depending on the application-specific parameters hop, dop and t
as well as the load.)
cycle
The user must evaluate and design the safety chain in accordance with the relevant standards and the required safety level.
The entire concept of the control system, in which the safety component is integrated, must be validated to the relevant standards.
2
BNS 300
Operating instructions Safety sensor
EN
M 30 x 1.5
70
M30x1,5
2
2
ø 30
2
ø 30
3. Mounting
3.1 General mounting instructions
During fitting, the requirements of ISO 14119 must be observed.
• Fitting is only authorised in a de-energised condition
• Do not use the sensor and the actuator as a mechanical backstop
• Any mounting position, provided that the active surfaces are opposite
• Screw both nuts in the provided mounting holes to fix the safety
sensor (max. tightening torque 300 Ncm)
• Do not install the safety sensor and the actuator in strong magnetic
fields
• If possible, do not install the safety sensor and the actuator on ferromagnetic material.
• Do not subject the safety sensor and actuator to extreme vibrations
and shocks.
• Keep away from metal chips
• The mounting distance between two sensors should always be at
least 50 mm.
Safety sensor and actuator must be permanently fitted to the safety guards and protected against displacement by suitable measures (tamperproof screws, gluing, drilling of the screw heads).
Actuator
BPS 300 with plastic enclosure
ø 2
ø 4,5
14
90°
15
BPS 303 for food-processing industry, with plastic enclosure
30
ø 2
14
ø 37
15
3.2 Dimensions
All measurements in mm.
Safety sensor with cable
6
78
Safety sensor with connector
5
36
83,6
BPS 303 SS
36
for food-processing industry, with metal enclosure
1,5
13,8
ø 37
15
M4
1000
Actuator BPS 303 and BPS 303 SS
The actuators are primarily provided for use in the food-processing industry and therefore are not labelled.
LED
12
M12x1
The actuators are fixed by means of the supplied tamper-proof screws. The mounting hole must have a diameter of 4.5 mm. Next to the mounting hole, a second mounting hole must be provided. This hole is used for the fixture of the displacement protection dowel. Position of the dowel: refer to the image below.
3
Operating instructions Safety sensor
BNS 300
EN
1
0
1
2
3
4
5
2
2,5
3
3
3
6
8
10
10
BN
BU
24 VDC
30 mAL+L-
24 VDC
1
5
L+
24 VDC
30 mA
3 1 2 4
1
3.3 Axial misalignment
A horizontal and vertical misalignment of the safety sensor and the actuator is tolerated. The possible misalignment depends on the distance of the active surfaces of the sensor and the actuator. The sensor remains active within the tolerance range.
The specified switching distances refer to opposedly mounted safety sensors and actuators.
Assured switching distance: sao = 5 mm,
8 mm (ordering suffix -2211, -2334)
Assured switch-off distance: sar = 15 mm,
18 mm (ordering suffix -2211,
-2334)
3.4 Adjustment
If the central marking of the actuator is within the represented base position area, the authorisation signal is given.
4.3 Connector plug
Integrated connector M12, 4-pole
4
3
2
5. Set-up and maintenance
5.1 Functional testing
The safety function of the safety components must be tested. The following conditions must be previously checked and met:
1. Fitting of the sensor and the actuator
2. Fitting and integrity of the power cable
3. The system is free of dirt and soiling (in particular metal chips)
5.2 Maintenance
In the case of correct installation and adequate use, the safety sensor features maintenance-free functionality. A regular visual inspection and functional test, including the following steps, is recommended:
• Check the fitting of the sensor and the actuator
• Remove possible metal chips
• Check the cable for damage.
Adequate measures must be taken to ensure protection against tampering either to prevent tampering of the safety guard, for instance by means of replacement actuators.
Damaged or defective components must be replaced.
Recommended Adjustment
Align the safety sensor and actuator at a distance of 0.5 x s
.
ao
4. Electrical connection
4.1 General information for electrical connection
The electrical connection may only be carried out by authorised personnel in a de-energised condition.
The safety sensors must be wired in accordance with the wire colours or the pin configuration.
4.2 Contact variants
The contact position shows the actuated sensor function when the safety guard is closed. The LED is illuminated when the guard is closed. Inductive loads (e.g. contactors, relays, etc.) are to be provided with suitable interference suppression circuitry.
BNS 300-01ZG BNS 300-01ZG-2211
BNS 300-01ZG-2230
BNS 300-01ZG-2334 BNS 300-01ZG-2271 BNS 300-01ZG-2246 (42 VAC)
BK BK
100 mA
2 3
30
4
mA
A L-
6. Disassembly and disposal
6.1 Disassembly
The safety switchgear must be disassembled in a de-energised condition only.
6.2 Disposal
The safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations.
BNS 300-01ZG-ST
4
EN
BNS300-C-EN
BNS 300
Operating instructions Safety sensor
7. EU Declaration of conformity

EU Declaration of conformity

Original K.A. Schmersal GmbH & Co. KG
We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
Name of the component: BNS 300
Type: See ordering code
Description of the component: Safety sensor with integrated safety-monitoring module
Relevant Directives: Machinery Directive
Applied standards: DIN EN 60947-5-3:2005,
Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com
EMC-Directive RoHS-Directive
DIN EN ISO 13849-1:2008, DIN EN ISO 13849-2:2008
2006/42/EC 2014/30/EU 2011/65/EU
Notied body, which approved the full quality assurance system, referred to in Appendix X, 2006/42/EC:
Person authorized for the compilation of the technical documentation:
Place and date of issue: Wuppertal, April 20, 2016
TÜV Rheinland Industrie Service GmbH Alboinstr. 56, 12103 Berlin
ID n°: 0035
Oliver Wacker Möddinghofe 30 42279 Wuppertal
Authorised signature
Philip Schmersal
Managing Director
The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net.
5
K. A. Schmersal GmbH & Co. KG
Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal
Phone: +49 - (0)2 02 - 64 74 - 0 Telefax: +49 - (0)2 02 - 64 74 - 1 00 E-Mail: info@schmersal.com Internet: http://www.schmersal.com