BN 80
Technical data
Enclosure: glass-fibre reinforced thermoplastic
Operating principle: magnetic
Actuating magnet: BP 6 S, BP 7 S, BP 10, BP 10 S, BP 15 S,
2 x BP 15 S, BP 34 S, 2 x BP 34 S, BP 20 S, BP 20 S,
BP 31 S, BP 11 S, BP 12 S (not included in delivery)
Protection class: IP67 to IEC 60529
Ambient temperature:
- Storage temperature: –25 °C … +75 °C
Electrical connection: Cable LiYY 2 x 0.25 mm², 1 m
Switching voltage:
- BN 80-RZ: max. 200 VAC/DC
- BN 80-10Z/-01Z: max. 250 VAC/DC
Switching current:
- BN 80-RZ: max. 1.5 A
- BN 80-10Z/-01Z: max. 0.5 A
Switching capacity:
- BN 80-RZ: max. 30 VA, W
- BN 80-10Z/-01Z: max. 10 VA, 8 W
Sparkover voltage: > 450 VAC (50 Hz)
Switching time “Close“: max. 2 ms
Switching time “Open”: max. 0.07 ms
Bounce duration: max. 0.5 ms
Mechanical life: 1000000000 operations
Electrical life: 5,000,000 operations
depending on load
Resistance to vibration: 15 g on sine wave oscillation
Product description
The magnetic reed switch has been developed for situations in which
minimal clearance is available. Despite its compact dimensions, its
switching capacity is sufficient to switch a relay.
The NC or NO function depends on the actuating direction and the
polarity of the actuating magnet. The actuators for the magnetic safety
sensors must be ordered separately.
Ordering code
This operating instructions manual applies to the following types:
-➀Z
BN 80
No. Option Description
01 1 NC
➀
10 1 NO
R 1 bistable contact
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The currently valid declaration of conformity can be
downloaded from the internet at www.schmersal.net.
Dimensions (in mm)
Magnetic reed switches BN 80
33,5
6,5
3,5
0,5
4
13
4
9
x.000 / 01.2019 / v.A. - 103028222-EN / A / 2019-01-14 / AE-Nr.
EN
1

Operating instructions
Magnetic reed switches
BN 80
Mounting
Actuating distance up to 60 mm depending on version and actuating
magnet.
The user must observe the country-specific installation
standards as well as all prevailing safety regulations and
accident prevention rules.
The electrical connection may only be carried out by
authorised personnel in a de-energised condition.
Actuation and switching distances
1 NC contact BN 80-01Z with N-S actuating magnet
1 NO contact BN 80-10Z with N-S actuating magnet
Switching capacity
A
1,0
0,9
0,8
0,7
0,6
0,5
0,4
0,3
0,2
0,1
Switching distance
BN 80-01Z up to 20 mm
BN 80-10Z up to 32 mm
BN 80- RZ up to 60 mm
Disassembly and disposal
Disassembly
The switch must be disassembled in a de-energised condition only.
Disposal
The switch must be disposed of in an appropriate manner in
accordance with the national prescriptions and legislations.
1 bistable contact BN 80-RZ with N actuating magnet