instrucciones actual en su
idioma oficial de la UE en
nuestra página de Internet
www.schmersal.net.
Il manuale d‘istruzioni aggiornato
IT
nella vostra lingua (lingua ufficiale
UE) è scaricabile in Internet
all‘indirizzo
www.schmersal.net.
U vindt de huidige versie van
NL
de gebruikshandleiding in uw
officiële landstaal op het Internet,
www.schmersal.net.
På www.schmersal.net findes
DA
aktuelle betjeningsvejledninger
på EU's officielle sprog.
Vous trouverez la version
FR
actuelle du mode d’emploi dans
votre langue nationale officielle
sur l’Internet,
www.schmersal.net.
日本語の取扱説明
JP
書は、インターネット
(www.schmersal.net)から
ダウンロード出来ます。
Tutaj znajdziesz aktualną wersję
PL
instrukcji obsługi w Twoim
języku na stronie internetowej
www.schmersal.net.
AZM 415-22
AZM 415-33
1. About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional
information.
O manual de instruções actual,
PT
no seu idioma oficial da UE,
encontra-se na nossa página de
Internet www.schmersal.net.
På www.schmersal.net finner
SV
ni de aktuella versionerna av
bruksanvisningen på EU’s
officiella språk.
Content
1 About this document
1.1 Function ..............................................1
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating
instructions manual, the country specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
In case of improper use or manipulation of the safety switchgear, personal hazards or damages to machinery or plant
components cannot be excluded. The relevant requirements
of the standard ISO 14119 must be observed.
1
Operating instructions
Solenoid interlock
AZM 415-22
AZM 415-33
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from
defective mounting or failure to comply with this operating instructions
manual. The manufacturer shall accept no liability for damages
resulting from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary
repairs, conversions and modifications to the device are strictly
forbidden; the manufacturer shall accept no liability for damages
resulting from such invasive work, arbitrary repairs, conversions and/or
modifications to the device.
2. Product description
2.1 Ordering code
This operating instructions manual applies to the following types:
Only if the information described in this operating instructions
manual are realised correctly, the safety function and
therefore the compliance with the Machinery Directive is
maintained.
2.2 Special versions
For special versions, which are not listed in the order code below 2.1,
these specifications apply accordingly, provided that they correspond to
the standard version.
2.3 Purpose
The AZM 415 solenoid interlock has been designed to prevent movable
safety guards, e.g. fences, covers or doors, in conjunction with the
control part of a machine, e.g. fail-safe delay timers or fail-safe standstill
monitors, from being opened before hazardous conditions (e.g. run-on
mouvements) have been eliminated. The AZM 415-33 includes three
switch inserts and is designed for monitoring double safety guards.
Interlocks with power to lock principle may only be used in
special cases after a thorough evaluation of the accident risk,
since the safety guard can be opened immediately on failure
of the power supply or upon activation of the main switch.
The safety switchgears are classified according to
ISO 14119 as type 2 interlocking devices.
Power to unlock
➀➁ ➂➃ ➄
Power to unlock
without manual release
Manual release using triangular key
(only for power to unlock principle)
Solenoid interlock with manual release AZM 415-33PDKE
The manual release is only used with components that operate on the
power to unlock principle. It is used as a mounting tool and also as a
tool to open a closed and locked safety guard in case of a power failure.
The point of access to the manual release or the manual release itself
must be protected in accordance with the provisions of the professional
association, e.g. by sealing during mounting.
Unlocking: using triangular key (available as accessory)
Reset: by turning the triangular key back
The user must evaluate and design the safety chain in
accordance with the relevant standards and the required
safety level.
The entire concept of the control system, in which the safety
component is integrated, must be validated to the relevant
standards.
2.4 Technical data
Standards:IEC 60947-5-1, ISO 14119
Enclosure:light-alloy die-cast, enamel finish
Actuator and locking bolt:zinc-plated metal / aluminium
Locking force F:
- AZM 415-22:3,500 N
- AZM 415-33:2,500 N (each safety guard)
Latching force:150 ... 400 N (adjustable)
Coding level according to ISO 14119: low
Ambient temperature: −25 °C … + 50 °C
Protection class: IP67
Degree of pollution: 3
Positive break travel (unlocked):AZM 415-22: 5 mm
AZM 415-33: 4,5 mm
Positive break force (unlocked):min. 15 N (depending on
the setting of the ball latch)
Actuating speed: max. 0.2 m/s
Max. actuating frequency:2,000 s/h
Mechanical life:> 1,000,000 operations
Contact material: Silver
Contact types:Change-over contact with double break, type Zb
Utilisation category: AC-15
Rated operating current/voltage Ie/Ue:4 A / 230 VAC
Rated impulse withstand voltage U
Rated insulation voltage Ui:250 V
Thermal test current I
Max. fuse rating:6 A gG D-fuse
Required rated short-circuit current:1,000 A
Magnet switch-on time:100 %
Rated control voltage Us:24 VAC / DC,
Power consumption:max. 10 W
A
IEC 60947-5-1; slow action, NC contact with
positive break
(including conductor ferrules)
:4 kV
imp
:6 A
the
110 VAC, 50 / 60 Hz,
230 VAC, 50 / 60 Hz,
2
EN
Operating instructions
MT
Bdxxhs/h3600
0,1 x n
op
t
cycle
88
Solenoid interlock
AZM 415-22
AZM 415-33
2.5 Safety classification of the interlocking function
Standards:ISO 13849-1
Envisaged structure:
- Basically: applicable up to Cat. 1 / PL c
- With 2-channel usage and
fault exclusion mechanism*: applicable up to Cat. 3 / PL d
with suitable logic unit
B
NC contact: 2,000,000
10D
B
NO contact at 10% ohmic contact load: 1,000,000
10D
Mission time:20 years
* If a fault exclusion to the 1-channel mechanics is authorised.
TF
D
(Determined values can vary depending on the application-specific
parameters hop, dop and t
If multiple safety components are wired in series, the Performance
Level to ISO 13849-1 will be reduced due to the restricted error
detection under certain circumstances.
2.6 Safety classification of the guard locking function
If the device is used as an interlock for personal safety, a safety
classification of the guard locking function is required.
When classifying the guard locking function, a distinction must be
made between monitoring of the interlocking function and control of the
release function.
The following safety classification of the unlocking function is based on
the application of the principle of safety energy disconnection for the
solenoid supply.
10Dopop
n
op
as well as the load.)
cycle
3. Mounting
3.1 General mounting instructions
Four mounting holes are provided for fitting the solenoid interlock. The
solenoid interlock must not be used as an end stop. Any mounting
position. The mounting position however must be chosen so that the
ingress of dirt and soiling in the used opening is avoided. A smooth
insertion of the actuator in the enclosure must be ensured.
Please observe the relevant requirements of the standards
ISO 12100, ISO 14119 and ISO 14120.
Mounting of the actuator
See actuator mounting instructions.
The actuator must be permanently fitted to the safety guards
and protected against displacement by suitable measures
(tamperproof screws, gluing, drilling of the screw heads).
3.2 Dimensions
All measurements in mm.
AZM 415-22
29,5
23,5
¤ 11
¤ 6,5
A
100
24,7
M23x1
M20x1,5/ST
84
M20x1,5/STR
The classification of the release function is only valid for
devices with monitored guard locking function and in the
power to unlock version (see ordering code).
A fault exclusion for the locking device of the solenoid interlock can be
assumed by a safety external energy disconnection.
In this case, the locking device of the solenoid interlock does not have
an effect on the failure probability of the unlock function.
The safety level of the unlock function is determined exclusively by the
external safety power shutdown.
Safety power
shutdown
+24 VDC
PL ?
PFH
d
0 VDC
Fault exclusion with regard to wiring routing must be
observed.
Solenoid
interlocks
A1
?
A2
Guard locking
function
If for a certain application the power to unlock version of
a solenoid interlock cannot be used, for this exception an
interlock with power to lock can be used if additional safety
measure need to be realised that have an equivalent safety
level.
28
8,6
46,5
AZM 415-33
114
130
141
124
20
E
46,5
29,5
11
¤ 11
108
¤ 6,5
125
A
M20x1,5/STL
M20x1,5/ST
44,8
8,6
M23x1
Key
A setting screw: ball latch 150 ... 400 N
E Manual release
3.3 Adjustment
In the unlocked condition, the safety guard is kept in a closed condition
by the adjustable ball latch. By rotating a hexagonal key wrench
clockwise, the desired holding force can be increased; if the hexagonal
key wrench is rotated counterclockwise, the holding force is decreased.
The holding force must always be set as low as possible.
42,542,5
26
M23x1
EN
3
Operating instructions
Solenoid interlock
AZM 415-22
AZM 415-33
4. Electrical connection
4.1 General information for electrical connection
The electrical connection may only be carried out by
authorised personnel in a de-energised condition.
If the risk analysis indicates the use of a monitored interlock
they are to be connected in the safety circuit with the
contacts indicated with the symbol .
4.2 Connection and sealing
For the cable entry, suitable cable glands with an appropriate degree
of protection must be used. Non-used openings must be sealed by
means of threaded plugs. The switching compartment must be cleaned
(removal of cable excess etc.); put back the cover after wiring and
uniformly tighten the cover screws.
Tightening torque for the fixing screws:
- Cover: 0,6 … 0,7 Nm (AZM 415-33: 1,2 … 1,4 Nm)
- Bottom cover: 0,7 … 0,8 Nm
4.3 Contact variants
Contacts shown in a de-energised condition and with the actuator
inserted.
Power to unlock principle
AZM 415-22ZPKAAZM 415-33ZPDKA
13 11
A1
S1
A2
14 12
21
24
23
13 11
A1
S2
22
2122
233324
S2
S1
14 12
A2
3132
S3
34
5. Set-up and maintenance
5.1 Functional testing
The safety function of the safety components must be tested. The
following conditions must be previously checked and met:
1. Fitting of the solenoid interlock and the actuator
2. Check the integrity of the cable entry and connections
3. Check the switch enclosure for damage
5.2 Maintenance
A regular visual inspection and functional test, including the following
steps, is recommended:
1. Check for tight installation of the actuator and the switch
2. Remove particles of dust and soiling
3. Check cable entry and connections
Adequate measures must be taken to ensure protection
against tampering either to prevent tampering of the safety
guard, for instance by means of replacement actuators.
Damaged or defective components must be replaced.
6. Disassembly and disposal
6.1 Disassembly
The safety switchgear must be disassembled in a de-energised
condition only.
6.2 Disposal
The safety switchgear must be disposed of in an appropriate
manner in accordance with the national prescriptions and legislations.
Power to lock
AZM 415-22ZPKAAZM 415-33ZPDKA
13 11
14 12
A1
A2
S2
22
21
24
23
P
13 11
S1
14 12
A1
A2
S1
P
Key
A
Positive break NC contact
Monitoring the interlock according to ISO 14119
P
Actuated
Q
Not actuated
23
3132
332434
S2
2221
S3
4
EN
Operating instructions
Solenoid interlock
7. EU Declaration of conformity
EU Declaration of conformity
AZM 415-22
AZM 415-33
OriginalK.A. Schmersal GmbH & Co. KG
We hereby certify that the hereafter described components both in their basic design and construction conform
to the applicable European Directives.
Name of the component:AZM 415
Type:See ordering code
Description of the component:Interlocking device with electromagnetic