schmersal AZM 170 series Operating Instructions Manual

AZM 170 I
Operating instructions Solenoid interlock
EN
1
1. About this document
1.1 Function
1.2 Target group: authorised qualified personnel
Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation.
The machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selection, mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could lead to failures or malfunctions. Warning: Failure to comply with this warning notice could lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine. It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer. Detailed information regarding the range of applications can be found in the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating instructions manual, the country-specific installation standards as well as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: www.schmersal.net.
The information contained in this operating instructions manual is provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and maintenance are observed.
1.6 Warning about misuse
In case of improper use or manipulation of the safety switch­gear, personal hazards or damages to machinery or plant components cannot be excluded when safety switchgear is used. The relevant requirements of the standard ISO 14119 must be observed.
Content
1 About this document
1.1 Function ..............................................1
1.2 Target group: authorised qualied personnel..................1
1.3 Explanation of the symbols used ...........................1
1.4 Appropriate use ........................................1
1.5 General safety instructions ...............................1
1.6 Warning about misuse ...................................1
1.7 Exclusion of liability .....................................2
2 Product description
2.1 Ordering code .........................................2
2.2 Special versions........................................2
2.3 Destination and use .....................................2
2.4 Technical data .........................................3
2.5 Safety classication .....................................3
3 Mounting
3.1 General mounting instructions .............................3
3.2 Dimensions ...........................................4
4 Electrical connection
4.1 General information for electrical connection..................5
4.2 Contact variants........................................6
5 Set-up and maintenance
5.1 Functional testing.......................................7
5.2 Maintenance ..........................................7
6 Disassembly and disposal
6.1 Disassembly...........................................7
6.2 Disposal ..............................................7
7 EU Declaration of conformity
x.000 / 10.2016 / v.A. - 101212802-EN / C / 2016-09-30 / AE-Nr. 6583
EN
Operating instructions. . . . . . . . . . . . .pages 1 to 8
Original
2
Operating instructions Solenoid interlock
AZM 170 I
EN
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual. The manufacturer shall accept no liability for damages resulting from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the device are strictly forbidden; the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device.
2. Product description
2.1 Ordering code
This operating instructions manual applies to the following types:
AZM 170➀-➁Z➂I➃-➄-➅-
➆ ➇
No. Option Description
Cut clamps
SK Screw connection
11 1 NO / 1 NC 02 2 NC
Latching force 5 N
R Latching force 30 N
Power to unlock
A Power to lock
Cable gland ST M12 x 1 connector ST-2431 M12 connector, separated magnet monitoring
B1 Actuator B1 included B5 Actuator B5 included B6L Actuator B6L included B6R Actuator B6R included
Manual release 2197 Manual release from side (default in the
connector and power-to-unlock version) 1637 Gold-plated contacts
24 VAC / DC Us 24 VAC / DC 110 VAC Us 110 VAC 230 VAC Us 230 VAC
AZM 170➀-➁Z➂I➃➄-➅-➆ 24 VAC / DC No. Option Description
SK Screw connection ST M12 x 1 connector
12 / 11 1 NO 2 NC / 1 NO 1 NC 12 / 02 1 NO 2 NC / 2 NC 12 / 00 1 NO 2 NC / ­11 / 11 1 NO 1 NC / 1 NO 1 NC 11 / 02 1 NO 1 NC / 2 NC 02 / 10 2 NC / 1 NO 02 / 01 2 NC / 1 NC
Latching force 5 N
R Latching force 30 N
Power to unlock
A Power to lock
B1 Actuator B1 included B5 Actuator B5 included B6L Actuator B6L included B6R Actuator B6R included
1637 Gold-plated contacts
2197 Manual release for Power to unlock
Only if the information described in this operating instructions manual are realised correctly, the safety function and therefore the compliance with the Machinery Directive is maintained.
2.2 Special versions
For special versions, which are not listed in the order code below 2.1, these specifications apply accordingly, provided that they correspond to the standard version.
2.3 Destination and use
The solenoid interlock has been designed to prevent in conjunction with the control part of a machine, movable safety guards from being opened before hazardous conditions have been eliminated. The AZM 170 I solenoid interlocks with individual coding offer a higher protection against tampering.
Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened.
The safety switchgear units are classified as type 2 interlocking devices in accordance with ISO 14119 and are rated as highly coded.
Manual release
A manual release is available as a mounting tool and in the event of a power failure in case the power to unlock principle is used. If the triangular key is turned 180°, the locking bolt is pulled into the unlocking position. Please ensure that jamming by external influence on the actuator is avoided. The normal locking function is only restored after the triangular key has been returned to its original position. After being put into operation, the manual release must be secured by installing the sealing plug, which is included in delivery.
Manual release Manual release from side
Ordering suffix -2197 or ST
Triangular key TK-M5 (101100887) available as accessory.
Emergency exit
Fitting and actuation only from within the hazardous area. To activate the emergency exit, turn the red lever in the direction of the arrow to the end stop. Please ensure that jamming by external influence on the actuator is avoided.
The user must evaluate and design the safety chain in accordance with the relevant standards and the required safety level.
The entire concept of the control system, in which the safety component is integrated, must be validated to the relevant standards.
3
AZM 170 I
Operating instructions Solenoid interlock
EN
2.4 Technical data
Standards: IEC 60947-5-1, ISO 14119, BG-GS-ET-19 Enclosure: glass-fibre reinforced thermo-
plastic, self-extinguishing
Actuator and locking bolt: stainless steel 1.4301 Contact material: Silver Holding force F: 1000 N Latching force: 5 N
- Ordering suffix R: 30 N Coding level according to ISO 14119: high Protection class: IP67 Contact type: change-over contact with double break, type Zb
or 2 NC contacts, with galvanically
separated contact bridges
Switching system:
A
IEC 60947-5-1; slow action,
NC contact with positive break
Cable entry: M20 x 1.5 Connection: Cut clamps, screw terminals or M12 connector Cable type: flexible Cable section:
- IDC method of termination (cut clamps): 0.75...1.0 mm²
- Screw terminals: 0.25...1.5 mm² (incl. insulated
conductor ferrules)
Rated impulse withstand voltage U
imp
: 4 kV
- Connector: 0.8 kV Rated insulation voltage Ui: 250 V
- Connector: 60 V Thermal test current I
the
: 6 A
- Connector: 2 A Utilisation category: DC 13
- AZM 170-…-11 and AZM 170-…-02 AC-15, DC-13
- Connector: DC-13 Rated operating current/voltage Ie/Ue: 4 A / 24 VDC;
4 A / 230 VAC;
- Connector: 2 A / 24 VDC Required short-circuit current: 1000 A Max. fuse rating: 6 A gG D-fuse Connector: 2 A gG D-fuse Positive break travel: 11 mm Positive break force: 8.5 N for each NC contact fitted Magnet: 100% ED Rated control voltage Us: 24 VAC / DC;
110 VAC 50 / 60 Hz;
230 VAC 50 / 60 Hz
Power consumption: max. 12 W Ambient temperature: −25 °C … +60 °C Mechanical life: > 1 million operations Actuating speed: max. 2 m/s Actuating frequency: max. 1000 operations/h
2.5 Safety classification
Standards: ISO 13849-1 Envisaged structure:
- Basically: applicable up to Cat. 1 / PL c
- With 2-channel usage and
fault exclusion mechanism*: applicable up to Cat. 3 / PL d
with suitable logic unit
B
10d
NC contact: 2,000,000
B
10d
NO contact at 10% ohmic contact load: 1,000,000 Service life: 20 years
* If a fault exclusion to the 1-channel mechanics is authorised.
MT
TF
Bdxxhs/h3600
d
10d op op
op
n
0,1 x n
op
t
cycle
(Determined values can vary depending on the application-specific parameters hop, dop and t
cycle
as well as the load.)
If multiple safety components are wired in series, the Performance Level to ISO 13849-1 will be reduced due to the restricted error detection under certain circumstances.
3. Mounting
3.1 General mounting instructions
On delivery, the actuator is in inserted condition. For power-to-unlock components, the actuator must be released by means of the manual release. If the triangular key is turned 180°, the locking bolt is pulled into the unlocking position. The normal locking function is only restored after the triangular key has been returned to its original position.
Two mounting holes are provided for fixing the enclosure. The solenoid interlock is double insulated. The use of an earth wire is not authorised. The solenoid interlock must not be used as an end stop. Any mounting position. The mounting position must be chosen so as to avoid the penetration of dirt in the used holes. The unused opening must be sealed by means of slot sealing plugs. Tightening force for the Torx T10 cover screws 0.7 ... 1 Nm.
The safety component and the actuator must be permanently fitted to the safety guards and protected against displacement by suitable measures (tamperproof screws, gluing, drilling, pinning).
Please observe the relevant requirements of the standards ISO 12100, ISO 14119 and ISO 14120.
4
Operating instructions Solenoid interlock
AZM 170 I
EN
3.2 Dimensions
All measurements in mm.
AZM 170 with cut clamps and cable glands
ø 4-10
ø 4,2
24
22
15
90
31
4
60
23
8,2
ca. 24
33
53
M20
30
8
17
-2197
AZM 170SK with screw terminals and cable glands
108
24
15
90
23
17
8,2
ca. 24 76,5
31
¤ 4,2
ø 4-10
45
M20
30
8
22
-2197
KEY: Manual release from side, ordering suffix -2197
AZM 170...-ST with connectors, 2 x 4 poles, A- or B-coding
ø 4,2
24
22
15
20
M12
M12
37
90
18
31
4
60
17
15,5
23
8,2
AZM 170ST with connectors, 1x 4 poles, 1 x 8 poles
ø 4,2
24
22
15
58
¤18
1616
90
18
31
4
76,5
17
16
23
8,2
¤18
Actuator
Straight actuator B1 Angled actuator B5
30
22
20
23
2
33
10
4,3
4,5
30
22
20
8
23
12
2
36
13
7,5
4,3
Flexible actuator B6L Flexible actuator B6R
22
32
30
7
4,3
R min. 50
R min. 50
28
12
23
7
11
24 4
32
30
2
ba
a
b
22
32
30
4,3
R min. 50
R min. 50
22
30
23
20
4,3
11
28
6
7
ba
a
b
5
AZM 170 I
Operating instructions Solenoid interlock
EN
Mounting of the actuator
The marks on the used actuator opening of the solenoid interlock and on the actuator must be opposite.
Please observe that, when fixing the switch e.g. by means of rivetting or welding, the insertion depth of the actuator is not modified. Different actuator forms are available. The actuators B1 and B5 are preferably used for sliding and removable safety guards. For hinged guards, the B6R and B6L actuators.
When the switch is fitted on a hinged safety guard, please ensure that the point of rotation is located within the range of the upper surface of the safety switch, in which the actuator hook is inserted (refer to table).
Actuating radii
d
R min.
d
R min.
R
min
[mm]
d
[mm]
R
min
[mm]
d
[mm]
B6L 50 11 50 11
B6R 50 11 50 11
B1
B5
Key
d
d
R min.
R m
in.
Actuating radius over the small edge of the actuator
d
R m
in.
Actuating radius over the wide edge of the actuator
The axis of the hinge must be d mm above and in a parallel plane to the top surface of the safety switch. The basis setting provides a minimum radius of Rmin.
Actuator B6L / B6R
ba
b
b
a
a
b
The B6L or B6R actuators are set to the smallest radius in factory. To
increase the radius, the setting screws a + b must be turned by means
of a hexagonal key A/F 2.5 mm.
4. Electrical connection
4.1 General information for electrical connection
The electrical connection may only be carried out by authorised personnel in a de-energised condition.
If the risk analysis indicates the use of a monitored interlock they are to be connected in the safety circuit with the contacts indicated with the symbol .
For the cable entry, suitable cable glands with an appropriate degree of protection must be used.
Cut clamp terminals
The IDC method of termination (cut clamp technology) enables connecting flexible wires with cable section 0.75 - 1 mm2 without using conductor ferrules. To this effect, strip the wire according to the drawing (refer to the wiring example) and insert it into the cable gland, close the cable gland, push the conductors in the groove of the cover (refer to wiring example) and screw the cover back. Observe that the individual conductors remain in position to avoid jamming.
70 mm
Screw terminals (SK version)
Unscrew the cover of the enclosure. Connect the cables to the terminal block. Use insulated conductor ferrules to that effect. Screw the cover back on the enclosure.
6
Operating instructions Solenoid interlock
AZM 170 I
EN
4.2 Contact variants
Contacts shown in a de-energised condition and with the actuator inserted.
AZM 170 I with cut clamps and screw terminals
Power to unlock Power to lock
1 NO 1 NC
(ordering sufx -11)
1 NO 1 NC
(ordering sufx -11)
A1
A2
14 22
21
32
13
A1
A2
14 22
21
32
13
2 NC
(ordering sufx -02)
2 NC
(ordering sufx -02)
A1
A2
12 22 21
32
11
A1
A2
12 22 21
32
11
1 NO 2 NC / -
(ordering sufx -12/00)
1 NO 2 NC / -
(ordering sufx -12/00)
A11311
12 21 22
14
A2
A1
11 21
13
14
12 22
A2
A11311
12 21 22
14
A2
A1
11 21
13
14
12 22
A2
2 NC / 1 NC
(ordering sufx -02/01)
2 NC / 1 NC
(ordering sufx -02/01)
A131
32 A2
31
32
A1
11
21
12
22
A2
11
12 21 22
31
32
A1
11 21
12
22
A2
A131
32 A2
11
12 21 22
2 NC / 1 NO
(ordering sufx -02/10)
2 NC / 1 NO
(ordering sufx -02/10)
A113
14 A2
13
14
A1
11
21
12
22
A2
11
12 21 22
A113
14 A2
13
14
11 21
12
22
11
12 21 22
A1
A2
1 NO 1 NC / 1 NO 1 NC
(ordering sufx -11/11)
1 NO 1 NC / 1 NO 1 NC
(ordering sufx -11/11)
A1
11 13
1412
23
31
32
24
A2
3123
24 32
A1
A2
1311
12
14
A1
11 13
1412
23
31
32
24
A2
3123
24 32
A1
A2
1311
12
14
1 NO 1 NC / 2 NC
(ordering sufx -11/02)
1 NO 1 NC / 2 NC
(ordering sufx -11/02)
11 13
1412
A1
41
31
32
42
A2
31 41
4232
A1
A2
1311
12
14
31 41
4232
A1
A2
1311
12
14
A1
11 13
1412
41
31
32
42
A2
AZM 170 I with connector
Power to unlock Power to lock
1 NO 1 NC
(ordering sufx -11)
1 NO 1 NC
(ordering sufx -11)
A1
A2
14 22
21
32
13
1122334
4
A1
A2
14 22
21
32
13
1122334
4
2 NC
(ordering sufx -02)
2 NC
(ordering sufx -02)
A1
A2
12 22
21
32
11
1122334
4
A1
A2
12 22
21
32
11
1122334
4
1 NO 2 NC / 2 NC
(ordering sufx -12/02)
1 NO 2 NC / 2 NC
(ordering sufx -12/02)
A131 41
4232 A2
41
31
32
42
A1
11 21 13
1412 22
A2
1234
1234 5 678
1311
12 21 22
14
41
31
32
42
A1
11 21 13
1412 22
A2
A131 41
4232 A2
1234
1234 5 678
1311
12 21 22
14
1 NO 2 NC / 1 NO 1 NC
(ordering sufx -12/11)
1 NO 2 NC / 1 NO 1 NC
(ordering sufx -12/11)
A13123
24 32 A2
23
31
32
24
A1
11 21 13
1412 22
A2
1311
12 21 22
14
1234
1234 5 678
23
31
32
24
A1
11 21 13
1412 22
A2
A13123
24 32 A2
1311
12 21 22
14
1234
1234 5 678
1 NO 1 NC / 1 NO 1 NC
(ordering sufx -11/11)
1 NO 1 NC / 1 NO 1 NC
(ordering sufx -11/11)
A1
11 13
1412
23
31
32
24
A2
3123
24 32
1234
A1
A2
1234 5 678
13111214
31 41
4232
A1
A2
1234
13111214
1234 5 678
A1
11 13
1412
41
31
32
42
A2
7
AZM 170 I
Operating instructions Solenoid interlock
EN
AZM 170 I with connector
Power to unlock Power to lock
1 NO 1 NC / 2 NC
(ordering sufx -11/02)
1 NO 1 NC / 2 NC
(ordering sufx -11/02)
11 13
1412
A1
41
31
32
42
A2
31 41
4232
A1
A2
1234
13111214
1234 5 678
31 41
4232
A1
A2
1234
13111214
1234 5 678
A1
11 13
1412
41
31
32
42
A2
Key
A
Positive break NC contact Monitoring the interlock according to ISO 14119
5. Set-up and maintenance
5.1 Functional testing
The safety function of the safety components must be tested. The following conditions must be previously checked and met:
1. Fitting of the solenoid interlock and the actuator
2. Check the integrity of the cable entry and connections
3. Check the switch enclosure for damage
5.2 Maintenance
A regular visual inspection and functional test, including the following steps, is recommended:
1. Check for tight installation of the actuator and the switch
2. Remove particles of dust and soiling
3. Check cable entry and connections
Adequate measures must be taken to ensure protection against tampering either to prevent tampering of the safety guard, for instance by means of replacement actuators.
Damaged or defective components must be replaced.
6. Disassembly and disposal
6.1 Disassembly
The safety switchgear must be disassembled in a de-energised condition only.
6.2 Disposal
The safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations.
8
EN
AZM170I-C-EN
Operating instructions Solenoid interlock
AZM 170 I
7. EU Declaration of conformity
The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net.
Name of the component: AZM 170 I
Type: See ordering code
Description of the component: Interlocking device with electromagnetic
interlock for safety functions
Relevant Directives: Machinery Directive
EMC-Directive RoHS-Directive
2006/42/EC 2014/30/EU 2011/65/EU
Applied standards: DIN EN 60947-5-1:2010,
DIN EN ISO 14119:2014
Person authorized for the compilation of the technical documentation:
Oliver Wacker Möddinghofe 30 42279 Wuppertal
K. A. Schmersal GmbH & Co. KG
Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal
Phone: +49 - (0)2 02 - 64 74 - 0 Telefax: +49 - (0)2 02 - 64 74 - 1 00 E-Mail: info@schmersal.com Internet: http://www.schmersal.com
Place and date of issue: Wuppertal, September 7, 2016
Authorised signature
Philip Schmersal
Managing Director
EU Declaration of conformity
Original K.A. Schmersal GmbH & Co. KG
Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com
We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
Loading...