Schmalz EVE-KL Operating Instructions Manual

Innovative Vacuum for Automation
Operating Instructions
EVE-KL
30.30.01.00867/00 | 04.2015
Table of Contents
Preface ........................................................................................... 2
Product Description ...................................................................... 3
Use ............................................................................................. 3
Principle of Operation ................................................................. 3
Cooling ....................................................................................... 4
Start Controls.............................................................................. 4
Safety ............................................................................................. 4
Intended Use .............................................................................. 4
Safety Notes ............................................................................... 4
Noise Emission ........................................................................... 4
Transport ....................................................................................... 4
Transport in Packaging ............................................................... 4
Transport without Packaging....................................................... 4
Storage ........................................................................................... 5
Short-term Storage ..................................................................... 5
Conservation .............................................................................. 5
Installation and Commissioning ................................................... 5
Installation prerequisites ............................................................. 5
Mounting Position and Space................................................. 5
Suction Connection ................................................................ 6
Gas Discharge ....................................................................... 6
Electrical Connection / Controls ............................................. 6
Installation .................................................................................. 6
Mounting a NEMA-Motor with BoWex-Coupling ..................... 6
Mounting ................................................................................ 7
Checking Synchronising Gear Oil .......................................... 7
Connecting Electrically ........................................................... 7
Connection Scheme Three-Phase Motor ............................. 7
Connecting Lines/Pipes ......................................................... 8
Recording of Operational Parameters .................................... 8
Operating Notes ......................................................................... 8
Use ........................................................................................ 8
Conveying Condensables Vapours ........................................ 9
Maintenance ................................................................................... 9
Maintenance Schedule ............................................................... 9
Monthly ............................................................................... 9
Every 3 Months: .................................................................. 9
Every 6 Months: .................................................................. 9
Every Year: ....................................................................... 10
Every 20000 Operating Hours, At the Latest after 6 Years: 10
Changing Synchronising Gear Oil ............................................. 10
Overhaul ....................................................................................... 10
Removal from Service ................................................................. 10
Temporary Removal from Service............................................. 10
Recommissioning ..................................................................... 10
Dismantling and Disposal ......................................................... 10
Troubleshooting .......................................................................... 12
Sectional Drawing ....................................................................... 15
Spare Parts .................................................................................. 16
Spare parts Kits ........................................................................... 16
Accessories ................................................................................. 16
Oil ................................................................................................. 16
EC-Declaration of Conformity ..................................................... 17
Technical Data ............................................................................. 18
Schmalz - World of Vacuum tecnologie ..................................... 20
Preface
Congratulations on your purchase of the Schmalz vacuum pump. With watchful observation of the field’s requirements, innovation and steady development Schmalz delivers modern vacuum and pressure solutions worldwide.
These operating instructions contain information for
product description,
safety,
transport,
storage,
installation and commissioning,
maintenance,
overhaul,
troubleshooting and
spare parts
of the vacuum pump. Version drive with integrated frequency inverter:
The drive with integrated frequency inverter is subject to a separate instruction manual.
For the purpose of these instructions, “handling” the vacuum pump means the transport, storage, installation, commissioning, influence on operating conditions, maintenance, troubleshooting and overhaul of the vacuum pump.
Prior to handling the vacuum pump these operating instructions shall be read and understood. If anything remains to be clarified please contact your Schmalz representative!
Keep these operating instructions and, if applicable, other pertinent operating instructions available on site.
Preface EVE-KL
Seite 2 30.30.01.00867-00_EN / 04.2015
a Eye bolt b Terminal box c Directional arrow d Cooling air outlet e Oil sight glass f Oil drain plug g Suction connection (with inlet
air filter) h Inlet air filter (optional) i Cooling air inlet j Position of condensate drain
cock (optional for version
“Aqua”) k Gas discharge l Acoustic enclosure m Cylinder n Rotor o Non return valve p Suction connection (without
inlet air filter)
Product Description
Use
The vacuum pump is intended for
the suction of
air and other dry, non-aggressive, non-toxic and non-explosive gases
Conveying media with a lower or higher density than air leads to an increased thermal and/or mechanical load on the vacuum pump and is permissible only after prior consultation with Schmalz.
Max. allowed temperature of the inlet gas: 40 °C Standard-version:
The gas shall be free from vapours that would condensate under the temperature and pressure conditions inside the vacuum pump.
Version “Aqua”:
The vacuum pump features the corrosion protection coating CPC and is capable of conveying water vapour page 9: Conveying Condensable Vapours). Conveyance of other vapours shall be agreed upon with Schmalz. Conveyance of water or other liquids in liquid phase increases the power consumption and shall therefore be avoided (risk of drive
overload). The vacuum pump is intended for the placement in a non-potentially explosive environment.
Max. permissible number of startings per hour: 12 Vacuum pumps MM 1324 AV standard-version are thermally
suitable for continuous operation down to ultimate pressure.
Vacuum pumps MM 1324 AV Version “Aqua” are thermally suitable for continuous operation at intake pressures down to 200 hPa abs (200 mbar abs). By means of process control and/or vacuum relief valves it must be made sure that the minimum allowed intake pressure will not be underrun.
Vacuum pumps MM 1202 AV, MM 1200 AV, MM 1252 AV and MM 1250 AV are thermally suitable for continuous operation at intake pressures down to 100 hPa abs (100 mbar abs). By means of process control and/or vacuum relief valves it must be made sure that the minimum allowed intake pressure will not be underrun.
Vacuum pumps MM 1322 AV and MM 1320 AV (version 600…3600 min-1) are thermally suitable for continuous operation at intake pressures down to 150 hPa abs (150 mbar abs). MM 1320 AV (version 600…4200 min-1) are thermally suitable for continuous operation at intake pressures down to 200 hPa abs (200 mbar abs). By means of process control and/or vacuum relief valves it must be made sure that the minimum allowed intake pressure will not be underrun.
Version “Aqua”:
The safety valve on the vacuum pump protects the vacuum pump against overheating only. It is not designed for frequent use and must therefore not be used as a system pressure regulating valve.
Principle of Operation
The vacuum pump works on the claw principle. The components are dimensioned such, that on the one hand there
is never contact between the two claws or between a claw and the cylinder, on the other hand the gaps are small enough to keep the clearance loss between the chambers low.
In order to avoid the suction of solids, the vacuum pump is equipped with a screen (715) in the suction connection.
In order to avoid reverse rotation after switching off, the vacuum pump is equipped with a non-return valve (o, 714).
EVE-KL
30.30.01.00867-00_EN / 04.2015 Seite 3
Product Description
The vacuum pump compresses the inlet gas absolutely oil-free. A lubrication of the pump chamber is neither necessary nor allowed.
Cooling
The vacuum pump is cooled by
radiation of heat from the surface of the vacuum pump
the air flow from the fan wheel of the drive motor
the process gas
the air flow from the fan wheel on the shaft of the vacuum
pump
Start Controls
The vacuum pump comes without start controls. The control of the vacuum pump is to be provided in the course of installation.
Noise Emission
For the sound pressure level in free field according to EN ISO 2151
page 18: Technical Data.
CAUTION The vacuum pump emits noise of high intensity in a narrow
band. Risk of damage to the hearing. Persons staying in the vicinity of a non noise insulated vacuum
pump over extended periods shall wear ear protection.
Transport
Safety
Intended Use
Definition: For the purpose of these instructions, “handling” the
vacuum pump means the transport, storage, installation, commissioning, influence on operating conditions, maintenance, troubleshooting and overhaul of the vacuum.
The vacuum pump is intended for industrial use. It shall be handled only by qualified personnel.
The allowed media and operational limits ( Description) and the installation prerequisites ( Installation Prerequisites) of the vacuum pump shall be
observed both by the manufacturer of the machinery into which the vacuum pump is to be incorporated and by the operator.
The maintenance instructions shall be observed.
Prior to handling the vacuum pump these installation and operating instructions shall be read and understood. If anything remains to be clarified please contact your Schmalz representative!
Safety Notes
The vacuum pump has been designed and manufactured according to state-of-the-art methods. Nevertheless, residual risks may remain. These operating instructions highlight potential hazards where appropriate. Safety notes are tagged with one of the keywords DANGER, WARNING and CAUTION as follows:
DANGER Disregard of this safety note will always lead to accidents
with fatal or serious injuries.
WARNING Disregard of this safety note may lead to accidents with
fatal or serious injuries.
CAUTION Disregard of this safety note may lead to accidents with minor
injuries or property damage.
page 3: Product
➔➔➔
page 5:
➔➔➔
Transport in Packaging
Packed on a pallet the vacuum pump is to be transported with a forklift.
Transport without Packaging
In case the vacuum pump is packed in a cardboard box with inflated cushions:
Remove the inflated cushions from the box
In case the vacuum pump is packed in a cardboard box cushioned with rolled corrugated cardboard:
Remove the corrugated cardboard from the box
In case the vacuum pump is laid in foam:
Remove the foam
In case the vacuum pump is bolted to a pallet or a base plate:
Remove the bolting between the vacuum pump and the
pallet/base plate
In case the vacuum pump is fastened to the pallet by means of tightening straps:
Remove the tightening straps
CAUTION Do not walk, stand or work under suspended loads.
Make sure that the eyebolt (a, 615) is in faultless condition (replace a damaged, e.g. bent eyebolt with a new one)
Make sure that the eye bolt (a, 615) is fully screwed in and tightened by hand
Attach lifting gear securely to the eyebolt (a, 615) on the synchronising gear
When the vacuum pump is equipped with a very heavy drive motor and would hang very inclined (>10°) on the synchronising gear eyebolt alone:
Attach lifting gear securely to the eyebolts on the
synchronising gear (a, 615) and the drive motor
In case the drive motor comes without an eyebolt or the eyebolt on the drive motor is located at an unfavourable position:
Loop a belt/rope with suitable length and strength around
the flange of the drive motor
Attach the lifting gear to a crane hook with safety latch
Lift the vacuum pump with a crane
Safety
EVE-KL
Seite 4 30.30.01.00867-00_EN / 04.2015
In case the vacuum pump was bolted to a pallet or a base plate:
Remove the stud bolts from the rubber feet
Storage
Short-term Storage
Make sure that the suction connection and the gas discharge are closed (leave the provided plugs in)
Store the vacuum pump
If possible in original packaging,
indoors,
dry,
dust free and
vibration free.
Conservation
In case of adverse ambient conditions (e.g. aggressive atmosphere, frequent temperature changes) conserve the vacuum pump immediately. In case of favourable ambient conditions conserve the vacuum pump if a storage of more than 3 months is scheduled.
Make sure that all ports are firmly closed; seal all ports that are not sealed with PTFE-tape, gaskets or o-rings with adhesive tape
Note: VCI stands for “volatile corrosion inhibitor”. VCI-products (film, paper, cardboard, foam) evaporate a substance that condenses in molecular thickness on the packed good and by its electro-chemical properties effectively suppresses corrosion on metallic surfaces. However, VCI-products may attack the surfaces of plastics and elastomers. Seek advice from your local packaging dealer! Schmalz uses CORTEC VCI 126 R film for the overseas packaging of large equipment.
Wrap the vacuum pump in VCI film
Store the vacuum pump
If possible in original packaging,
indoors,
dry,
dust free and
vibration free.
For commissioning after conservation:
Make sure that all remains of adhesive tape are removed from the ports
Commission the vacuum pump as described in the chapter Installation and Commissioning (page 5)
Installation and Commissioning
Installation prerequisites
CAUTION In case of non-compliance with the installation prerequisites,
particularly in case of insufficient cooling: Risk of damage or destruction of the vacuum pump and
adjoining plant components! Risk of injury! The installation prerequisites must be complied with.
Make sure that the integration of the vacuum pump is carried out such that the essential safety requirements of the Machine Directive 2006/42/EC are complied with (in the responsibility of the designer of the machinery into which the vacuum pump is to be incorporated; page 17: note in the EC-Declaration of Conformity)
Mounting Position and Space
Make sure that the environment of the vacuum pump is not potentially explosive
Make sure that the following ambient conditions will be complied with:
ambient temperature: 0 … 40 °C
ambient pressure: atmospheric
Make sure that the environmental conditions comply with the
protection class of the drive motor (according to the nameplate)
Make sure that the vacuum pump will be placed or mounted horizontally
Make sure that the base for placement / mounting base is even
Make sure that in order to warrant a sufficient cooling there will
be a clearance of minimum 1 m between the vacuum pump and nearby walls
Make sure that no heat sensitive parts (plastics, wood, cardboard, paper, electronics) will touch the surface of the vacuum pump
Make sure that the installation space or location is vented such that a sufficient cooling of the vacuum pump is warranted
CAUTION During operation the surface of the vacuum pump may reach
temperatures of more than 70 °C. Risk of burns!
Make sure that the vacuum pump will not be touched inadvertently during operation, provide a guard if appropriate
Make sure that the sight glass (e, 76) of the synchronising gear will remain accessible
In case the synchronising gear oil change is planned to be carried out on location:
Make sure that the drain port (f, 80) and the filling port (72)
of the synchronising gear will remain easily accessible
EVE-KL
30.30.01.00867-00_EN / 04.2015 Seite 5
Installation and Commissioning
Suction Connection
CAUTION Intruding foreign objects or liquids can destroy the vacuum
pump.
In case the inlet gas can contain dust or other foreign solid particles:
Make sure that a suitable filter (5 micron or less) is
installed upstream the vacuum pump
Make sure that the suction line fits to the suction connection (g/p) of the vacuum pump
Make sure that the gas will be sucked through a vacuum-tight flexible hose or a pipe
In case of using a pipe:
Make sure that the pipe will cause no stress on the
vacuum pump’s connection, if necessary use an expansion joint
Make sure that the line size of the suction line over the entire length is at least as large as the suction connection (g/p) of the vacuum pump
In case the length of the suction line exceeds 2 m it is prudent to use larger line sizes in order to avoid a loss of efficiency and an overload of the vacuum pump. Seek advice from your Schmalz representative!
In case the vacuum pump shall be maintained after shutdown of the vacuum pump:
Provide a manual or automatic operated valve (= non-
return valve) in the suction line
Version “Aqua”, if very humid process gases and/or adverse operating cycles bear the risk, that condensates remain in the vacuum pump:
Provide a shut-off valve, a drip-leg and a drain cock in the
suction line, so that condensates can be drained from the suction line
Provide a valve for the unthrottled suction of ambient air
(ambient air valve) between the shut-off valve and the vacuum pump (in order to dry the vacuum pump after process end)
For non ultimate-pressure-proof vacuum pumps provide a
vacuum relief valve (suitable for continuous operation) for the throttled aspiration of ambient air during warming up
Make sure that the anti-pulsation chamber is equipped
with a condensate drain cock (j) (optional; if the condensate drain cock is missing contact the Schmalz service)
Make sure that the suction line does not contain foreign objects, e.g. welding scales
Make sure that the line size of the discharge line over the entire length is at least 2”
In case the length of the discharge line exceeds 2 m it is prudent to use larger line sizes in order to avoid a loss of efficiency and an overload of the vacuum pump. Seek advice from your Schmalz representative!
Make sure that the discharge line either slopes away from the vacuum pump or provide a liquid separator or a drip leg with a drain cock, so that no liquids can back up into the vacuum pump
Electrical Connection / Controls
Make sure that the stipulations acc. to the EMC-Directive 2004/108/EC and Low-Voltage-Directive 2006/95/EC as well as the EN-standards, electrical and occupational safety directives and the local or national regulations, respectively, are complied with (this is the responsibility of the designer of the machinery into which the vacuum pump is to be incorporated; page 17: note in the EC-Declaration of Conformity).
Make sure that the power supply for the drive motor is compatible with the data on the nameplate of the drive motor
Make sure that an overload protection according to EN 60204-1 is provided for the drive motor
Make sure that the drive of the vacuum pump will not be affected by electric or electromagnetic disturbance from the mains; if necessary seek advice from the Schmalz service
In case of mobile installation:
Provide the electrical connection with grommets that serve
as strain-relief
Installation
Mounting a NEMA-Motor with BoWex­Coupling
For certain markets the vacuum pump is available without motor, but with a NEMA-adaptor flange and a BoWex-coupling.
Gas Discharge
The discharged gas must flow without obstruction. It is not permitted to shut off or throttle the discharge line or to use it as a pressurised air source.
The following guidelines for the discharge line do not apply, if the aspirated air is discharged to the environment right at the vacuum pump.
Make sure that the discharge line fits to the gas discharge (k) of the vacuum pump
In case of using a pipe:
Make sure that the pipe will cause no stress on the
vacuum pump’s connection, if necessary use an expansion joint
EVE-KL
Installation and Commissioning
Seite 6 30.30.01.00867-00_EN / 04.2015
Remove the NEMA-adaptor flange (I) from the vacuum pump
Pull the elastomer part (V) together with the hub (III) off the
shaft of the vacuum pump
Mount the NEMA-adaptor flange (I) on the motor (the bolts (II) are not part of the Schmalz scope of delivery)
Undo the cylinder screws (VI) and remove the elastomer part (V) from the hub (III)
Make sure that the parallel key is inserted into the motor shaft
Push the hub (III) onto the motor shaft such that the mounting
prevention regulation.
face of the hub (III) will be located 16±1 mm before the mounting face of the NEMA-adaptor flange (I) (sketch)
Fasten the hub (III) on the motor shaft using the set screw (IV)
Apply thread locking agent on the threads of the cylinder
screws (VI)
Mount the elastomer part (V) on the hub (III) with the cylinder screws (VI) and tighten the cylinder screws with 14 Nm
Mount the motor on the vacuum pump
Mounting
Make sure that the installation prerequisites (page 5) are complied with
Set down or mount the vacuum pump at its location
Checking Synchronising Gear Oil
The vacuum pump is delivered with oil filled synchronising gear. The level shall be slightly above the middle of the sight glass (e, 76).
Check on the sight glass (e, 76) that the proper amount of oil is filled
Connecting Electrically
WARNING Risk of electrical shock, risk of damage to equipment. Electrical installation work must only be executed by
qualified personnel that knows and observes the following regulations:
- IEC 364 or CENELEC HD 384 or DIN VDE 0100, respectively,
- IEC-Report 664 or DIN VDE 0110,
- BGV A2 (VBG 4) or corresponding national accident
Connection Scheme Three-Phase Motor
Delta connection (low voltage):
Star connection (high voltage):
Double star connection, multi-voltage motor with 9 terminals (low voltage):
CAUTION The connection schemes given below are typical. Depending on
the specific order or for certain markets deviating connection schemes may apply.
Risk of damage to the drive motor! The inside of the terminal box shall be checked for drive motor
connection instructions/schemes.
Note: For the connection of a drive with integrated frequency inverter see the separate operating instructions!
Electrically connect the drive motor
Connect the protective earth conductor
Star connection, multi-voltage motor with 9 terminals (high voltage):
Double star connection, multi-voltage motor with 12 terminals (low voltage):
EVE-KL
30.30.01.00867-00_EN / 04.2015 Seite 7
Installation and Commissioning
Delta connection, multi-voltage motor with 12 terminals (middle voltage):
Star connection, multi-voltage motor with 12 terminals (high voltage):
CAUTION Operation in the wrong direction of rotation can destroy the
vacuum pump in short time Prior to starting-up it must be made sure that the vacuum pump
is operated in the proper direction (clockwise rotating field).
Version with three-phase motor:
Determine the intended direction of rotation with the
arrow (c) (stuck on or cast)
“Bump” the drive motor ♦ Watch the fan wheel of the drive motor and determine the
direction of rotation just before the fan wheel stops
If the rotation must be changed:
Switch any two of the drive motor wires (three-phase
motor)
Connecting Lines/Pipes
Connect the suction line
Connect the discharge line
Installation without discharge line:
Make sure that the gas discharge (k) is open
Make sure that all provided covers, guards, hoods etc. are mounted
Make sure that the cooling air inlets and outlets are not covered or obstructed and that the cooling air flow is not affected adversely in any other way
Recording of Operational Parameters
As soon as the vacuum pump is operated under normal operating conditions:
Measure the drive motor current and record it as reference for future maintenance and troubleshooting work
Operating Notes
Use
CAUTION The vacuum pump is designed for operation under the
conditions described below. In case of disregard risk of damage or destruction of the
vacuum pump and adjoining plant components! Risk of injury! The vacuum pump must only be operated under the conditions
described below.
The vacuum pump is intended for
the suction of
air and other dry, non-aggressive, non-toxic and non-explosive gases
Conveying media with a lower or higher density than air leads to an increased thermal and/or mechanical load on the vacuum pump and is permissible only after prior consultation with Schmalz.
Max. allowed temperature of the inlet gas: 40 °C Standard-version:
The gas shall be free from vapours that would condensate under the temperature and pressure conditions inside the vacuum pump.
Version “Aqua”:
The vacuum pump features the corrosion protection coating CPC and is capable of conveying water vapour page 9: Conveying Condensable Vapours). Conveyance of other vapours shall be agreed upon with Schmalz. Conveyance of water or other liquids in liquid phase increases the power consumption and shall therefore be avoided (risk of drive
overload). The vacuum pump is intended for the placement in a non-potentially explosive environment.
Max. permissible number of startings per hour: 12 Vacuum pumps MM 1324 AV standard-version are thermally
suitable for continuous operation down to ultimate pressure. Vacuum pumps MM 1324 AV Version “Aqua” are thermally suitable
for continuous operation at intake pressures down to 200 hPa abs (200 mbar abs). By means of process control and/or vacuum relief valves it must be made sure that the minimum allowed intake pressure will not be underrun.
Vacuum pumps MM 1202 AV, MM 1200 AV, MM 1252 AV and MM 1250 AV are thermally suitable for continuous operation at intake pressures down to 100 hPa abs (100 mbar abs). By means of process control and/or vacuum relief valves it must be made sure that the minimum allowed intake pressure will not be underrun.
Vacuum pumps MM 1322 AV and MM 1320 AV (version 600…3600 min-1) are thermally suitable for continuous operation at intake pressures down to 150 hPa abs (150 mbar abs). MM 1320 AV (version 600…4200 min-1) are thermally suitable for continuous operation at intake pressures down to 200 hPa abs (200 mbar abs). By means of process control and/or vacuum relief valves it must be made sure that the minimum allowed intake pressure will not be underrun.
Version “Aqua”:
The safety valve on the vacuum pump protects the vacuum
pump against overheating only. It is not designed for frequent
use and must therefore not be used as a system pressure
regulating valve.
Installation and Commissioning
EVE-KL
Seite 8 30.30.01.00867-00_EN / 04.2015
CAUTION During operation the surface of the vacuum pump may reach
temperatures of more than 70 °C. Risk of burns! The vacuum pump shall be protected against contact during
operation, it shall cool down prior to a required contact or heat protection gloves shall be worn.
CAUTION The vacuum pump emits noise of high intensity in a narrow
band. Risk of damage to the hearing. Persons staying in the vicinity of a non noise insulated vacuum
pump over extended periods shall wear ear protection.
Make sure that all provided covers, guards, hoods etc. remain mounted
Make sure that protective devices will not be disabled
Make sure that cooling air inlets and outlets will not be covered
or obstructed and that the cooling air flow will not be affected adversely in any other way
Make sure that the installation prerequisites (page 5: Installation Prerequisites) are complied with and will remain complied with, particularly that a sufficient cooling will be ensured
Conveying Condensables Vapours
Version “Aqua”:
CAUTION Due to the corrosion protection coating CPC the vacuum pump
is capable of conveying water vapour. Very humid process gases and/or adverse operating cycles can
lead to residual condensates, though, which cause corrosion. If this is the case, it is necessary to counteract residual
condensates by warming up the vacuum pump, conveyance of ambient air after process end and regular draining of the anti­pulsation chamber
Close the shut-off valve in the suction line ♦ Warm up the vacuum pump for approx. 10 minutes
At process start: Open the shut-off valve in the suction line At the process end:
Close the shut-off valve in the suction line ♦ Open the ambient air valve ♦ Operate the vacuum pump for another approx. 10 minutes ♦ Close the ambient air valve ♦ Regularly drain condensate from the anti-pulsation
chamber (j)
Maintenance
DANGER In case the vacuum pump conveyed gas that was
contaminated with foreign materials which are dangerous to health, harmful material can reside in filters.
Danger to health during inspection, cleaning or replacement of filters.
Danger to the environment. Personal protective equipment must be worn during the
handling of contaminated filters. Contaminated filters are special waste and must be
disposed of separately in compliance with applicable regulations.
CAUTION During operation the surface of the vacuum pump may reach
temperatures of more than 70 °C. Risk of burns!
Prior to disconnecting connections make sure that the connected pipes/lines are vented to atmospheric pressure
Maintenance Schedule
Note: The maintenance intervals depend very much on the
individual operating conditions. The intervals given below shall be considered as starting values which should be shortened or extended as appropriate. Particularly heavy duty operation, such like high dust loads in the environment or in the process gas, other contaminations or ingress of process material, can make it necessary to shorten the maintenance intervals significantly.
Monthly
Make sure that the vacuum pump is shut down and locked against inadvertent start up
In case an inlet air filter (h) is installed:
Check the inlet air filter (h), if necessary replace
In case of operation in a dusty environment:
Clean as described under page 9: Every 6 Months
Every 3 Months:
Make sure that the vacuum pump is shut down and locked against inadvertent start up
Check the level and the colour of the synchronising gear oil
The level shall be slightly above the middle of the sight glass (e, 76). The level of the synchronising gear should stay constant over the
lifetime of the oil. If the level does fall, the gear is leaky and the vacuum pump requires repair (Schmalz service).
Every 6 Months:
Make sure that the housing is free from dust and dirt, clean if necessary
Make sure that the vacuum pump is shut down and locked against inadvertent start up
Remove the acoustic enclosure
EVE-KL
30.30.01.00867-00_EN / 04.2015 Seite 9
Maintenance
Note: Make sure that the foam mats do n o t get soaked with water
Clean the fan cowlings, fan wheels, the ventilation grilles and cooling fins
Mount the acoustic enclosure
Dispose of the used oil in compliance with applicable
regulations
Overhaul
Every Year:
Make sure that the vacuum pump is shut down and locked against inadvertent start up
In case an inlet air filter (h) is installed:
Replace the inlet air filter (h)
Check the inlet screen (715), clean if necessary
Every 20000 Operating Hours, At the Latest after 6 Years:
Note: The change interval of 20000 operating hours is valid for
Schmalz approved gear oils only. The change interval depends very much on the operating conditions. Borderline operation may reduce the change interval down to approximately 5000 operating hours or 6 months. Other gear oils may reduce the change interval.
Changing Synchronising Gear Oil
Make sure that the vacuum pump is shut down and locked against inadvertent start up
CAUTION In order to achieve best efficiency and a long life the vacuum
pump was assembled and adjusted with precisely defined tolerances.
This adjustment will be lost during dismantling of the vacuum pump.
It is therefore strictly recommended that any dismantling of the vacuum pump that is beyond of what is described in this manual shall be done by Schmalz service.
DANGER In case the vacuum pump conveyed gas that was
contaminated with foreign materials which are dangerous to health, harmful material can reside in pores, gaps and internal spaces of the vacuum pump.
Danger to health during dismantling of the vacuum pump. Danger to the environment. Prior to shipping the vacuum pump shall be
decontaminated as good as possible and the contamination status shall be stated in a “Declaration of Contamination” (form downloadable from www.schmalz.com).
Schmalz service will only accept vacuum pumps that come with a completely filled in and legally binding signed “Declaration of Contamination” (form downloadable from www.schmalz.com).
Remove the eyebolt (a, 615)
Remove the lid (424)
Undo the venting valve (72) for venting
Place a drain tray underneath the drain plug (f, 80)
Open the drain plug (f, 80) and drain the oil
Make sure that the seal ring on the drain plug (f, 80) is
serviceable, replace if necessary
Firmly reinsert the drain plug (f, 80) together with the seal ring
Remove the venting valve (72) completely
Fill in new gear oil until the level is slightly above the middle of
the sight glass (e, 76)
Make sure that the seal ring on the venting valve (72) is undamaged, if necessary replace the venting valve (72)
Firmly reinsert the venting valve (72) together with the seal ring
Mount the lid (424)
Reinsert the eyebolt (a, 615)
Removal from Service
Temporary Removal from Service
Prior disconnecting pipes/lines make sure that all pipes/lines are vented to atmospheric pressure
Recommissioning
Observe the chapter Installation and Commissioning (page 5)
Dismantling and Disposal
DANGER In case the vacuum pump conveyed gas that was
contaminated with foreign materials which are dangerous to health, harmful material can reside in pores, gaps and internal spaces of the vacuum pump.
Danger to health during dismantling of the vacuum pump. Danger to the environment. During dismantling of the vacuum pump personal
protective equipment must be worn. The vacuum pump must be decontaminated prior to
disposal.
Overhaul
EVE-KL
Seite 10 30.30.01.00867-00_EN / 04.2015
Drain the oil
Make sure that materials and components to be treated as
special waste have been separated from the vacuum pump
Make sure that the vacuum pump is not contaminated with harmful foreign material
According to the best knowledge at the time of printing of this manual the materials used for the manufacture of the vacuum pump involve no risk.
Dispose of the used oil in compliance with applicable regulations
Dispose of the vacuum pump as scrap metal
EVE-KL
30.30.01.00867-00_EN / 04.2015 Seite 11
Removal from Service
Troubleshooting
WARNING Risk of electrical shock, risk of damage to equipment. Electrical installation work must only be executed by qualified personnel that knows and observes the following regulations:
- IEC 364 or CENELEC HD 384 or DIN VDE 0100, respectively,
- IEC-Report 664 or DIN VDE 0110,
- BGV A2 (VBG 4) or corresponding national accident prevention regulation.
CAUTION During operation the surface of the vacuum pump may reach temperatures of more than 70 °C. Risk of burns! Let the vacuum pump cool down prior to a required contact or wear heat protection gloves.
Problem Possible Cause Remedy The vacuum pump does not reach the usual
pressure The drive motor draws a too high current
(compare with initial value after commissioning)
Evacuation of the system takes too long In case a vacuum relief valve/regulating
The screen (715) in the suction connection
In case a filter (h) is installed on the suction
Partial clogging in the suction, discharge or
Long suction, discharge or pressure line with
The valve disk of the inlet non-return valve is
Internal parts are worn or damaged Repair the vacuum pump (Schmalz service) The gas conveyed by the vacuum pump
smells displeasing The vacuum pump does not start The drive motor is not supplied with the
The drive motor starter overload protection is
One of the fuses has blown Check the fuses The connection cable is too small or too long
The vacuum system or suction line is not leak­tight
system is installed:
The vacuum relief valve/regulating system is misadjusted or defective
(g/p) is partially clogged
connection (g/p):
The filter (h) on the suction connection (g/p) is partially clogged
pressure line
too small diameter
stuck in closed or partially open position
Process components evaporating under vacuum
correct voltage or is overloaded
too small or trip level is too low
causing a voltage drop at the vacuum pump
Check the hose or pipe connections for possible leak
Adjust, repair or replace, respectively
Clean the screen (715) If cleaning is required too frequently install a
filter upstream Clean or replace the inlet air filter (h),
respectively
Remove the clogging
Use larger diameter
Disassemble the inlet, clean the screen (715) and the valve (o, 714) as required and reassemble
Check the process, if applicable
Supply the drive motor with the correct voltage
Compare the trip level of the drive motor starter overload protection with the data on the nameplate, correct if necessary
In case of high ambient temperature: set the trip level of the drive motor starter overload protection 5 percent above the nominal drive motor current
Use sufficiently dimensioned cable
Troubleshooting EVE-KL
Seite 12 30.30.01.00867-00_EN / 04.2015
The vacuum pump or the drive motor is
blocked
Make sure the drive motor is connected from the power supply
Remove the fan cover Try to turn the drive motor with the vacuum
pump by hand If the unit is still frozen: remove the drive
motor and check the drive motor and the vacuum pump separately
If the vacuum pump is blocked:
Repair the vacuum pump (Schmalz
The drive motor is defective Replace the drive motor (Schmalz service)
service)
(the proper function of the fan wheel requires the precise adjustment of the coupling on the motor shaft and the pump shaft; therefore the motor can be mounted by the Schmalz service only)
The vacuum pump is blocked Solid foreign matter has entered the vacuum
pump
Repair the vacuum pump (Schmalz service) Make sure the suction line is equipped with a
screen If necessary additionally provide a filter
Corrosion in the vacuum pump from remaining
condensate
Repair the vacuum pump (Schmalz service) Check the process Observe the chapter Conveying Condensable
Vapours (page 9)
Version with three-phase motor:
The vacuum pump was run in the wrong direction
Repair the vacuum pump (Schmalz service) When connecting the vacuum pump make
sure the vacuum pump will run in the correct direction (page 6 Installation)
The drive motor is running, but the vacuum pump stands still
The coupling between the drive motor and the vacuum pump is defective
Replace the coupling element (the proper function of the fan wheel requires
the precise adjustment of the coupling on the motor shaft and the pump shaft; therefore the motor can be mounted by the Schmalz service only)
The vacuum pump starts, but labours or runs noisily or rattles
The drive motor draws a too high current (compare with initial value after commissioning)
Loose connection(s) in the drive motor terminal box
Version with three-phase motor:
Not all drive motors coils are properly connected
Check the proper connection of the wires against the connection diagram
(particularly on motors with six coils) Tighten or replace loose connections
The drive motor operates on two phases only
Version with three-phase motor:
The vacuum pump runs in the wrong direction
Foreign objects in the vacuum pump
Verification and rectification page 5: Installation and Commissioning
Repair the vacuum pump (Schmalz service)
Stuck bearings
The vacuum pump runs very noisily Defective bearings Repair the vacuum pump (Schmalz serv) Worn coupling element Replace the coupling element Low oil level in the synchronising gear The synchronising gear is leaky
Repair the vacuum pump (Schmalz service)
Synchronising gear damaged due to operation
Repair the vacuum pump (Schmalz service)
with low oil level
EVE-KL Troubleshooting
30.30.01.00867-00_EN / 04.2015 Seite 13
The vacuum pump is very hot Insufficient air ventilation Make sure that the cooling of the vacuum
Ambient temperature too high Observe the permitted ambient temperatures Temperature of the inlet gas too high Observe the permitted temperatures for the
Mains frequency or voltage outside tolerance
range
Partial clogging of filters or screens
Partial clogging in the suction, discharge or pressure line
Long suction, discharge or pressure line with
too small diameter
pump is not impended by dust/dirt Clean the fan cowlings, the fan wheels, the
ventilation grilles and the cooling fins Install the vacuum pump in a narrow space
only if sufficient ventilation is ensured
inlet gas Provide a more stable power supply
Remove the clogging
Use larger diameter
Troubleshooting EVE-KL
Seite 14 30.30.01.00867-00_EN / 04.2015
Sectional Drawing
EVE-KL Sectional Drawing
30.30.01.00867-00_EN / 04.2015 Seite 15
Spare Parts
Note: When ordering spare parts or accessories acc. to the table
below please always quote the type (“Type”) and the serial no. (“No”) of the vacuum pump. This will allow Schmalz service to check if the vacuum pump is compatible with a modified or improved part.
The exclusive use of the genuine spare parts and consumables is a prerequisite for the proper function of the vacuum pump and for the granting of warranty, guarantee or goodwill.
Your point of contact for service and spare parts:
81 Seal ring for plug with magnet 1 0482 137 352
Inlet flange, lower part,
714
with non-return valve
715 Screen 1 0534 000 041
Filter cartridge, paper, for inlet
­filter (optional)
Filter cartridge, polyester, for inlet
-
filter (optional)
1 0915 000 670
1 0532 000 004
1 0532 121 864
J. Schmalz GmbH Aacher Straße 29 D - 72293 Glatten
Tel: +49(0) 7443 2403-0 Fax: +49(0) 7443 2403-259
Spare parts Kits
Spare parts kit Part no. Overhaul kit (incl. set of seals, marking “VT” and
“DT”; insert for flexible coupling for Rotex only) Set of seals (marking “DT”) 0990 134 021
0993 134 022
Accessories
Accessories Description Part no.
Inlet air filter
Liquid and dust separator STF 0250
Liquid separator LSS 0250
Liquid separator LSA 0250
inlet-side, horizontal, with paper cartridge, to separate solids
to protect against solids and liquids on the suction side
to protect against condensate and liquids on the suction side
to protect against condensate and liquids on the suction side, with automatic draining
0945 000 071
0962 117 387
0965 117 784
0965 117 780
Pos. Part Qty Part no. 72 Venting valve (=oil fill plug) with
seal ring 76 Sight glass 1 0583 000 001 77 Seal ring for sight glass 1 0480 000 271 80 Plug with magnet and seal ring 1 0415 134 870
1
0543 107 407
Oil
Denomination VS150 ISO-VG 150 Base PAO Density [g/cm³] 0.846 Kinematic viscosity at 40 °C
[mm²/s] Kinematic viscosity at 100 °C
[mm²/s] Flashpoint [°C] 236 Pourpoint [°C] -54 Part number 1 l packaging 0831 164 883 Part number 5 l packaging 0831 164 884 Filling quantity, approx. [l] 1
150
19.8
Spare Parts EVE-KL
Seite 16 30.30.01.00867-00_EN / 04.2015
EVE-KL EC-Declaration of Conformity
30.30.01.00867-00_EN / 04.2015 Seite 17
Technical Data
For motor connection parameters see nameplate
Type
Frequency
[Hz]
Ultimate pressure standard version
[hPa abs = mbar abs]
Ultimate pressure version “Aqua”
[hPa abs = mbar abs]
]
-1
Nominal motor rating
[kW]
Nominal speed
[min
/h]
3
Sound pressure level (EN ISO 2151)
at 400 hPa (=mbar) abs.
suction pressure [db(A)]
Weight
[kg]
Ambient temperature range
[°C]
Ambient pressure
Synchronising gear oil qty
[l]
Nominal suction capacity
[m
Synchronising gear oil filled ex-works
MM 1324 AV
MM 1202 AV
MM 1252 AV
MM 1322 AV
MM 1200 AV
MM 1250 AV
MM 1320 AV 150* 8.1
MM 1320 AV 200* 8.1
*to be limited by means of process control and/or vacuum relief valves **see nameplate of the vacuum pump
50
60 4.2 1800 192 74
50
60
50
60 6.8 3600 300 79
50
60 6.5 3600 360 82
50/60
60 200*
100*
150*
100* 5.5
3.0 1500 160 70
4.0
4.2 3000 200 75
4.3
5.2 3600 240 79
5.5
5.0 3000 250 75
5.1
6.0 3000 300 77
6.0
600-
3600**
600-
4200**
max.
240
max.
300
max.
360
max.
420
79
82
86
~250
… 280
~235
~240
… 285
~275
… 310
~240
~250
~310
1
0 … 40
atmospheric
see nameplate
Technical Data EVE-KL
Seite 18 30.30.01.00867-00_EN / 04.2015
EVE-KL blank page
30.30.01.00867-00_EN / 04.2015 Seite 19
Global contact
Our sales network of local field representatives, international subsidiaries and trade partners ensures quick and competent information and advice in more than 50 countries worldwide.
www.schmalz.com/vertriebsnetz
Online dokumentation
Conveniently download catalogs, operating instructions and CAD data and get comprehensive information about our products and services.
www.schmalz.com/dokumentationen
How-tovideos
In short, easy-to-understand videos we explain the comprehensive functions offered by our products. Take a look, it’s worth it!
www.schmalz.com/gewusst-wie
J. Schmalz GmbH
Aacher Strasse 29 D-72293 Glatten Tel. +49 (0)7443 2403-0 Fax +49 (0)7443 2403-259 schmalz@schmalz.de www.schmalz.com
World of the Vacuum-Tecnologie
Note
These operating instructions were written in the German language. This document should be kept in a safe place for future reference.
The right to make technical changes is reserved. No responsibility is taken for printing errors or other types of errors.
Publisher
© J. Schmalz GmbH, Fehler! Verweisquelle konnte nicht gefunden werden. This document is protected by copyright. J. Schmalz GmbH retains the rights established thereby. Reproduction of
the contents, in full or in part, is only permitted within the limits of the legal provisions of copyright law. Any modifications to or abridgments of the document are prohibited without explicit written agreement from J. Schmalz GmbH.
Schmalz Services
Other services from consulting to training, see
www.schmalz.com/services
30.30.01.00867-00 / 04.2015
Loading...