*P516-130*
P516-130
Instructions for programming AD-Series ofine locks
AD-250
Ofine lock user guide
Para el idioma español, navegue hacia www.schlage.com/support.
Pour la portion française, veuillez consulter le site www.schlage.com/support.

Contents
Overview ...........................................................................................................................3
Getting started ..................................................................................................................4
Schlage Utility Software (SUS) ......................................................................................... 4
Construction access mode ...............................................................................................5
Create the master construction credential - locks with card readers ............................5
Add Construction access mode user credentials - locks with card readers .................. 5
Cancel construction access mode ................................................................................5
Locks with keypads .......................................................................................................5
Test lock operation ............................................................................................................6
Mechanical test .............................................................................................................6
Electronic test................................................................................................................6
Reset to factory defaults ................................................................................................... 7
Level 1 factory default reset ..........................................................................................7
Level 2 factory default reset ..........................................................................................7
Batteries ...........................................................................................................................8
To install or replace batteries ........................................................................................8
Battery failure modes ....................................................................................................9
External power supply ......................................................................................................9
LED reference .................................................................................................................10
Schlage Button ............................................................................................................10
Inside Push Button (IPB) ............................................................................................10
Troubleshooting .............................................................................................................. 11
FCC Statements .............................................................................................................12
This product is compliant of UL 294 and ULC S319 standard. This product’s compliance would be
invalidated through the use of any add-on, expansion, memory or other module that has not yet been
evaluated for compatibility for use with this UL Listed product, in accordance with the requirements of
the Standards UL 294 and ULC S319. This product has been evaluated for CAN/ULC-S319 Class 1.
2 • Schlage • AD-250 user guide

Overview
The Schlage AD-250 is a standalone electronic lock in the AD-Series product line.
• May be powered by batteries or connected to external power using a UL 294 or
ULC S318 / ULC S319 listed power supply capable of sourcing at least 250 mA @ 12
or 24 VDC. See Batteries on page 8, or External power supply on page 9 for
more information.
• Outside lever is normally locked.
• Inside lever always allows egress.
• The lock maintains an audit trail of events.
• Congured using the Schlage Utility Software (SUS). See Schlage Utility Software
(SUS) on page 4 for more information.
Outside
Schlage
Button
Outside
Lever
Keyway
Mag Card
(Insert) Reader
Mag Card + Keypad
(Insert) Reader
Mag Card
(Swipe) Reader
Mag Card + Keypad
(Swipe) Reader
Inside
Optional
Inside Push
Button (IPB)
Optional
Thumbturn
Inside Lever
Battery
Compartment
3

Getting started
Follow these steps when setting up a new lock.
1. Install the lock. See the installation guide that came with the lock, or visit
www.schlage.com/support, for more information.
2. Make sure the batteries are installed properly. See Batteries on page 8 for more
information.
3. Congure the master construction credential (where applicable). See Construction
access mode on page 5 for more information. The lock will remain in construction
access mode until you are ready to set up the rest of the system.
4. Test the lock for proper mechanical and electronic operation. See Test lock operation on
page 6 for more information.
5. Consult the Schlage Utility Software (SUS) user guide for information about conguring
the lock.
6. Familiarize yourself with the information contained in this user guide.
Save this user guide for future reference.
Schlage Utility Software (SUS)
The Schlage Utility Software is used for programming and setup only.
The Schlage Utility Software (SUS) is used to congure locks. This includes transferring
data les between the access control software and locks. For further information about
SUS, see the SUS user guide.
4 • Schlage • AD-250 user guide