Duplication (copy, print, microfilm or any other form) as well as electronic spreading of this document is only permitted after formal writting consent of SCHAEFER GmbH. SCHAEFER GmbH reserves the right to carry out alterations of technical details without prior notice. For all transactions our General Conditions of Sale and Delivery shall be applicable. All rights reserved.
Ress. 010708 Revision: 2009-12-08
3
Index
1 General description ................................. 4
2 Illustration ................................................ 4
3 Configuration ........................................... 5
4 Connection ...............................................5
5 Programming ........................................... 6
5.1 Encoder or Connector? ................................... 7
6 Settings ..................................................... 8
6.1 Input .......................................................................9
6.1.1 Coding ................................................................ 9
6.1.2 Connection ...................................................... 10
6.2 Dot-matrix ....................................................... 11
6.2.1 Presentation .................................................... 11
6.2.2 Frequency ........................................................ 12
6.2.3 Brightness | Intensity .................................. 13
7 Technical data ....................................... 14
8 Models .....................................................14
Index
User Manual Dot-Matrix Display DMD 30/35
4
1 General description
DMD 30/35 range of dot-matrix display that can be used as Position Indicators-, direction- or re-starting Arrows, or a combination of both. The floor Position as well as the direction arrows can be displayed as follows: standing, flashing or scrolling. The displays are available with one digit (DMD 30/35­H1/V1), with two digits (DMD 30/35-H2/V2) or with three digits (DMD 30/35-H3). The H1, H2 and H3 dis­plays have there connections at the side of the display (as Illustrated below) and the V1 and V2 displays are connected from above. All Displays are configured and adjusted by DIP swit­ches located on the back of the Display. The indicating characters/figures, including there functions can also be configured by a PC using SCHAEFER DMD Config­Kit and can be changed at any time. Two free-defined special horizontally rolling texts messages (up to 14 characters) can be included. As from software version
2.6 on the DMD up to four special texts can be con­figured.
General description | Illustration
2 Illustration
5
Configuration | Connection
3 Configuration
Two different kinds of configuration are possible:
• Configuration of the DMD 30/35 at SCHAEFER
according to the customer requirement
• Configuration of the DMD 30/35 on site.
Therefore a DMD-Config-Kit is needed (article No. 010575).
4 Connection
In order to connect the DMD 30/35 you require either a Connector PCB for Binary or Grey code or an Enco­der PCB for signal per floor. (including ribboncable 25 cm).
Article No.
Common anode (neg) Common cathode (pos)
Encoder 1 out of 15 008808 008809
Encoder 1 out of 31 008806 008807
Connector 008812
6
5.1 Encoder or Connector ?
Programming
5 Programming
The pin configuration can be modified via PC (DMD­Config-Kit). Please note that the configuration of the encoder cannot be changed, especially if pins were defined as special text.
Pin configuration
5.1 Encoder or Connector ?
The table below gives you a general idea when an En­coder PCB or Connector PCB should be used. Depending on the number of Floors, horizontally rol­ling messages and type of arrows or travel signal used will depend on whether a connector or encoder is re­quired.
Note: More than two special texts are only possible as from software version 2.6 on the DMD.
Travel GND Down Up Adr 4 Adr 3 Adr 2 Adr 1 Adr 0 V in
Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin
10
9 8 7 6 5 4 3 2 1
7
5.1 Encoder or Connector ?
Programming
Horizon-
tally
Rolling
Messages
Floors
Codierung (control) Display possibilities
Dual/Gray 1 out of n Arrows Travelling
none
to 5 Connector Connector yes yes
6 to 15 Connector Encoder 1 out of 15 yes yes
16 to 31 Connector Encoder 1 out of 31 yes yes
1
to 4 Connector Connector yes yes
5 to 15 Connector Encoder 1 out of 15 und Connector yes yes
16 to 31 Connector Encoder 1 aus 31 yes no
2
to 3 Connector Connector yes yes
4 to 7 Connector Encoder 1 out of 15 und Connector yes yes
8 to 15 Connector Encoder 1 out of 15 und Connector yes no
16 to 31 Connector Encoder 1 out of 31 no no
3*
to 2 Connector Connector yes yes
3 Connector Encoder 1 out of 15 und Connector yes yes
4 to 7 Connector Encoder 1 out of 15 und Connector yes no
8 to 15 Connector Encoder 1 out of 15 no no
16 to 31 Connector Encoder 1 out of 15 no no
4*
to 2 Connector Connector yes no
3 Connector Encoder 1 out of 15 und Connector yes no
4 to 7 Connector Encoder 1 out of 15 und Connector no no
8 to 15 Connector Encoder 1 out of 15 und Connector no no
16 to 31 Connector no
* Mehr als zwei Sondertexte erst ab SW-Version 1.5 auf der DMD 27 möglich.
8
Settings
6 Settings
Different settings can be changed on the display by means of the buttons and respective DIP switches. The values are changed by the DIP switches and adju­sted by the buttons e. g. the brightness of the display can be adjusted as follows:- Switch the Dot Matrix Dip switch No3 to the on position. Press the Dot Matrix button until the required brightness is selected. The setting is saved after the corresponding DIP switch has been turned off.
DIP switches
Dot-matrix
DIP switches
Input
Indicator
Dot-Matrix Button
Input Status LED
1 2 3 4 1 2 3 4
Input Button
9
Settings
6.1 Input | 6.1.1 Coding
6.1 Input
6.1.1 Coding
With DIP switch Input 1 in the on position the co­ding type can be adjusted. By pressing the Input button the different coding type can be selected. The Status LED shows the present status. Switch off the DIP switch to save the selection.
LED: yellow
Binary
LED: yellow green 1 out of n
(signal per floor)
LED: green
Gray
Button
Button Button
10
Settings
6.1.2 Connection
6.1.2 Connection
DIP switch Input 2 controls the switching variant. By switching the DIP switch to the on position and pres­sing the input button, the display can be switched to common cathode (positive switching) or common an­ode (negative switching).
Button
LED: yellow Common cathode
(Positive switching)
LED: green Common anode
(Negative swithing)
Button
DIP switches Input 3 and 4 are reserved for later func­tions and have no effect.
11
6.2 Dot-matrix | 6.2.1 Presentation
Settings
6.2 Dot-matrix
With the dot-matrix button you can switch between different settings. The display shows the correspondi­ng adjustments. The setting is saved after the corre­sponding DIP switch has been turned off.
6.2.1 Presentation
With DIP switch dot-matrix 1, the graphic Versions of the character and arrows can be changed.
If the blinking option is selected, the floor position will be shown as „standing“, only the direction arrows will be displayed „blinking“.
standing
scrolling
blinking
Button
12
Settings
6.2.2 Frequenz
6.2.2 Frequency
With DIP switch dot-matrix 2, the flashing or scrol­ling frequency can be adjusted, this only applies if the Flashing or Scrolling mode is selected. This DIP switch has no function, if the “standing” mode is applied.
8 Z/sec
10 Z/sec
12 Z/sec
14 Z/sec
16 Z/sec
2 Hz
4 Hz
6 Hz 8 Hz 10 Hz
Button
13
6.2.3 Brightness/Intensity
Settings
50%
60%
70%
80%
100%
Button
6.2.3 Brightness/Intensity
With DIP switch dot-matrix 3, the brightness can be changed by pressing the Dot-Matrix Button.
DIP switch dot-matrix 4 is reserved for later func­tions and has no effect.
14
Technical data | Models
7 Technical data
Supply voltage: 12 V ... 30 V (DC, smoothed current)
Current requirement: DMD 30-H1/V1: up to 45 mA DMD 30-H2/V2: up to 75 mA DMD 30-H3: up to 105 mA
Temperature range: 0°C to +65°C/149 °F
Luminosity: red: 49 mcd green: 200 mcd blue: 40 mcd
Addressing 1 out of n: with additional Encoder PCB up to 31 floors
Addressing binary/Gray: with additional Connector PCB up to 31 floors
In conformity with:
8 Models
As well as the standard, other models are available:
• splash-proof model IPX3 according to EN 81-72
• temper proof model for category 1 according to EN 81-71
In conformity with: