Scantech ORION O-3050,Nexus N-3030 User Manual

User’s Manual
Scantech-ID ORION O-3050
Copyright © 2010, Scantech-ID BV.
This manual is copyrighted, with all rights reserved. Under the copyright laws, this manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic medium or machine readable form without prior written consent of Scantech International BV.
Limited Warranty
Under all circumstances this manual should be read attentively, before installing and/or using the pro-duct. In no event shall Scantech International BV be liable for any direct, indirect, special, consequential or incidental damages arising out of the use or inability to use this documentation or product, even if advised of the possibility of such damages. In particular, Scantech International BV shall not be liable for any hardware, software, or data that is stored or used with the product, including the cost of repairing, replacing or recovering the above. Scantech International BV reserves the right to change parts of the device at any time without preceding or direct announcement to the client. Scantech International BV reserves the right to revise this manual, and to make changes in the contents without obligation to notify any person or entity of the revision or change. A serial number appears on the product. Make sure that this official registration number has not been removed. It should be used whenever servicing by Scantech International BV or an authorized Scantech dealer is necessary.
Important
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to EN55022, and with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the user’s manual, may cause harmful interference to radio communications. Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Any unauthorized changes or modifications to this equipment could void the user’s authority to operate this equipment.
For CE-countries:
- The ORION is in conformity with the CE standards. Please note that a Scantech CE-marked power
supply unit should be used to conform to these standards.
For USA & Canada
- To be used with UL listed and CSA certified computers/POS systems.
- A utiliser avec des ordinateurs/systèmes POS registrés UL/certifiés CSA.
- This scanner should only be powered by a UL listed or CUL Certified Power Supply having limited power
source of Class 2 outputs, rated +12 Vdc / minimum 0,64 A, minimum 40 °C or the scanner should be directly powered by a UL listed and CSA certified computer/POS system, having limited power source of Class 2 outputs, rated 8 Vdc to 16 Vdc / minimum 0,55 A, minimum 40 °C.
Radio and television interference
Operation of this equipment in a residential area can cause interference with radio or television reception. This can be determined by turning the equipment off and on. The user is encouraged to try to correct the interference by one or more of the following measures:
Re-orientate the receiving antenna
Relocate the devices with respect to the receiver
Move the device away from the receiver
Plug the device into a different outlet in order to have the device and receiver on
different branch circuits If necessary, the user should consult the manufacturer, an authorized Scantech dealer or experienced radio/television technician for additional suggestions. The booklet "How to Identify and Resolve Radio-TV Interference Problems", prepared by the Federal Communications Commission, can be of help. It can be obtained from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004000003454.
P/N A1020015x January 29th 2010 First Version
Table of contents
Preface ...................................................................................................i
Chapter 1
The ORION O-3050 ..................................................................... 1
1.1 Unpacking the ORION O-3050................................................ 2
1.2 Declaration of conformity ...................................................... 4
1.3 Scanning bar codes with the ORION O-3050 ........................... 5
1.4 Scanner labelling .................................................................. 6
1.5 Maintaining the scanner......................................................... 9
1.6 Controlling the scanner from the POS system ....................... 10
Chapter 2
Installing the ORION O-3050 ...................................................... 13
2.1 Connecting the scanner....................................................... 14
2.2 Interface selection .............................................................. 16
2.3 Installing the scanner on a counter surface ........................... 17
2.4 Installing the scanner with the counter stand ............................ 19
2.5 Installing the scanner using the flexible scanner stand............ 19
2.6 Removing the scanner from the back cover plate .................. 22
Appendices ............................................................................................... 23
A Connector types and pin definitions...................................... 24
B Technical specifications....................................................... 27
C Troubleshooting.................................................................. 29
Preface
The ORION is a new presentation laser scanner which allows hands free bar code scanning, based on proven Scantech-ID technologies which form the basis of all our omni-directional scanners. Bar code labels are read by presenting the labels towards the scanner. Scanning labels with the ORION hardly requires any arm movement. As a result only little free space on the counter top is necessary.
The ORION can either be fixed on a counter surface or on a flexible stand. The flexible stand allows you to direct the scan pattern in a way that is optimal for your application.
The ORION reads all popular bar code symbologies. An important feature of the ORION is its programmable sleep mode. If the scanner is not used within a programmable period of time, the scanner switches off automatically. The scanner can be re-activated by pressing the switch on top of the scanner. The ORION is available in two colour versions, both supporting multiple interface for communication with any host system. The multiple interface versions are: RS-232 + USB + P-USB + Keyboard Wedge.
This manual contains two chapters and three appendices. The first chapter describes the ORION and its general features. The description for installation can be found in the second chapter. Precisely follow the instructions for the installation of the scanner. Default settings can be changed with the bar code labels from the Scantech Configuration Guide that came with the scanner. Appendix A gives the pin definition for the Data ports of the scanner. The pin definition may be required when you want to make a new cable for communication with the POS/computer. Technical specifications of the ORION can be found in Appendix B. Refer to Appendix C for troubleshooting if the scanner is not working properly.
Chapter 1 The ORION O-3050
The ORION O-3050
2
1.1 UNPACKING THE ORION O-3050
Remove the scanner and its accessories from the box and packing material. Refer to the packing list to make sure you have received all the items ordered. Visually inspect the scanner and accessories for any evidence of physical damage. Refer to the upper figure on page 5 to locate the interface label and make sure that the scanner interface corresponds with the host system interface. Immediately contact your supplier if anything appears to be damaged, or if the supported interface does not correspond with the host system interface.
The ORION O-3050
3
The specific parts of the ORION O-3050 are:
Sleep mode button
- When a sleep mode time-out is programmed,
the scanner can be re-activated by pressing this switch. The sleep mode feature is programmable with the menu labels from the Configuration guide. NOTE: The default value for the sleep mode time-out is set to 30 minutes. When the scanner is in sleep mode, the LED is intermittently flashing red.
LED
- A red LED indicates that the scanner is ready to
read a bar code. A green LED indicates a good read.
Good read buzzer
- The buzzer is heard whenever data has been
read correctly. The frequency and volume can be adjusted
Standard parts & accessories:
Flexible scanner stand
- The rotary and flexible stand allows you to
direct the scan pattern in a way that is optimal for your application (a mounting kit with screws and tapes is included).
Back cover plate
- This plate serves to fix the scanner to the
counter.
Interface cable
- One of various types of cable to connect to
your host computer / POS system.
Power supply
- Powers your scanner via the AC power outlet if
your scanner is not directly powered.
User’s manual
- This manual in print
Configuration guide
- Booklet containing barcodes for configuration
of your scanner
Optional parts & accessories:
Counter stand
- The stand serves to fix the scanner to the
counter.
The ORION O-3050
4
1.2 DECLARATION OF CONFORMITY
Scantech-ID B.V.
Scantech-ID BV Vanadiumweg 22 3812 PZ Amersfoort The Netherlands Tel. +31 (0)33 4698400 Fax +31 (0)33 4650615
Hereby declares under our sole responsibility that the product:
Product: ORION Model number: O-3050 (and equivalent) Product View:
Will comply with the following product specifications:
Laser Safety: - IEC 825-1 (1993) and 21 CFR1040 Electrical Safety: - EN 60950 (1992), IEC 950 (1991), UL 1950 3rd. edition,
c-UL (CSA-C22-2 950- M95)
EMC: - EN 55022:2006 + A1:2007
- EN 61000-3-2: 2006
- EN 61000-3-3: 1995 + A1:2001 + A2:2005
- EN 55024:1998 + A1:2001 + A2:2003
- IEC 61000-4-2: 1995 + A1: 1998 + A2: 2000;
- IEC 61000-4-3: 2006 + IEC: 61000 -4-4: 2004;
- IEC 61000-4-5: 2005 + IEC: 61000 -4-6: 2003; +A1: 2004 +A2: 2006;
- IEC 61000-4-8: 1993 + A1: 2000; IEC 61000 -4-11:2004
Please note that a Scantech ID CE-marked power supply unit should be used to conform the product specifications stated above.
The ORION O-3050
5
1.3 SCANNING BAR CODES WITH THE ORION O-3050
The ORION O-3050 is an omni-directional presentation scanner featuring a 7 directional scan field with a 24 lines scan pattern. Bar code labels can easily be read by presenting them to the scanner.
The scanner's scan volume is illustrated in the figure below. The optimal reading zone lies between 2 and 15 cm from the scanner window, but bar codes can be read up to 30 cm (11.8 in.) from the scanner window. If a scanner with flexible stand is purchased, the stand allows you to direct the optimal reading zone in a way that suits your application most.
Scanning a bar code label with a presentation scanner is very simple: present the product’s bar code label to the scanner as illustrated in the figure below.
Loading...
+ 28 hidden pages