OEM Shear Pin Load Cell
LS-3410-SP Series
Robust designs manufactured specifically for use in harsh and challenging environments offshore,
such as platforms, ships, rigs and drilling applications.
Redundant signal with dual electronics
Range up to 1200 metric tons
IP68, Submersible upon request
Ex ia IIC T4 , ATEX and IEC approved
Stainless Steel
The LS-3410-SP is a well proven 4-20mA output
Shear pin Transmitter with fast response time,
high accuracy and long life time performance in
harsh and hazardous environments.
More than 1000 custom designed version are
stored in our database. Huge flexibility in
design and a long record of field proven
solutions has made these sensors popular
among customers in the gas and oil industry.
The sensor is digitally calibrated with an
analogue 4-20mA output signal in a two
conductor configuration.
The electronics are molded and encapsulated
inside the sensor, proven to be the best
solution for EMC, potential leakage and long
lifetime performance.
Typical Applications are:
Offshore Drilling Offshore Production Cranes Winches Mooring systems
DS-0228 20.12.2016
www.scansense.no
Data Sheet
Technical information
Note: Due to continuous product improvement, published specifications may change without notice.
Electrical connections
Cable:
Hydraulic hose protected cable for tough environments Cable BFOU(i) Cable ӦLFLEX Cable MOR Polyrad Cable Subsea
Connector
Gisma (titanium) Souriau (brass) Souriau (nickel-chrome coated brass) Glenair (stainless steel)
Full scale load
0 - 5T 1200T
Maximum load at 20°C (Test Load)
0T ... 25T Full scale range x 2
25T … 180T Full scale range x 2 to x 1.33
180T 1200T Full scale range x 1.33
Temperature Range
-45°C to 80°C
Linearity
± 0.5% of full scale
Total accuracy at ambient temperature:
± 1% of full scale
TCS (Thermal Compensated Sensitivity)
Typical 0.03% full scale x (temp. - amb)
Output Current
4-20mA, Current Loop
Supply Voltage
12-28 VDC
Electrical connection
2 wire
Response time
Min.13ms
Power supply regulation
Yes
Voltage Spike Protection
Yes
Polarity protection
Yes
Insulation test
50 V DC (RMS) > 1GΩ
Sealing
IP68 / Submersible upon request
Material
Stainless steel
Intrinsic Safe Code
Ex ia IIC T4 Ga -45°C <Tamb<Ta: 80°C Ex ia IIIC T102°C Da