SO-161-R Ophthalmic Microscope User Manual Page 2 of 18
CONTENTS
CONTENTS_____________________________________________________________ 2
LIST OF FIGURES_______________________________________________________ 2
INTRODUCTION ________________________________________________________ 3
INTRODUCTION ________________________________________________________ 3
PARTS LIST ____________________________________________________________ 5
ASSEMBLY INSTRUCTIONS _______________________________________________ 6
TABLE MOUNTING ___________________________________________________ 6
MOUNTING TO THE SO-331 FLOOR STAND______________________________ 7
BATTERY CONNECTION, OPERATION, MAINTENANCE AND SAFETY _____ 9
USING THE MICROSCOPE ______________________________________________ 10
ARTICULATED ARM_________________________________________________ 10
POSITIONING THE MICROSCOPE______________________________________ 11
POWER SUPPLY CONTROLS __________________________________________ 11
LAMP REPLACEMENT _______________________________________________ 12
STERILISATION AND CLEANING______________________________________ 13
CARE OF THE OPTICAL HEAD ________________________________________ 14
ADJUSTING FOCUS FRICTION ________________________________________ 15
MOULD PELLET REPLACEMENT______________________________________ 15
SPECIFICATIONS ______________________________________________________ 17
LIST OF FIGURES
Figure 1: SO-161-R Microscope 3
Figure 2: SO-161-R Microscope shown with SO-331 Floor stand 4
Figure 3: Assembling the SO-161-R Microscope 7
Figure 4: Assembling the SO-161-R Microscope on SO-331 Floor stand 8
Figure 5: SO-161-R Power supply bottom panel 9
Figure 6: Articulated arm features 10
Figure 7: SO-161-R Power supply top panel 11
Figure 8: Changing the lamp 12
Figure 9: Sterilisable covers 13
Figure 10: Replacing the mould pellet 15
Issue number 1.0 X:\Current User Manuals\SO-161-R User Manual v1.0.doc
SO-161-R Ophthalmic Microscope User Manual Page 3 of 18
INTRODUCTION
Please read the following information carefully before installing and using the Scan Optics SO 161-R Ophthalmic microscope. Scan Optics is responsible for the safety, reliability and
performance of the equipment only if it is used in accordance with these instructions.
This microscope is designed for use by a certified practitioner, for magnified observation of
patients, and for use in an operating theatre as an observation aid during surgery. Environmental
storage and packing conditio ns of 60-95% relative humidity and 10-40 °C, are recommended for
this product.
No parts or accessories supplied with this microscope are supplied in a sterile condition.
Apart from those instructions within this manual, there are no user-serviceable parts in this
microscope. Scan Optics will retain the discretion to advise whether any repairs may be taken out
by external qualified technical personnel, or whether part(s) of the microscope must be returned to
the manufacturer’s premises for service or repairs to be carried out under warranty or otherwise.
Where appropriately qualified technical personnel are identified by a user, and ratified by Scan
Optics, then Scan Optics will make available on request any information that will assist in
repairing the equipment.
Figure 1: SO -161-R Microscope
Issue number 1.0 X:\Current User Manuals\SO-161-R User Manual v1.0.doc
SO-161-R Ophthalmic Microscope User Manual Page 4 of 18
Figure 2: SO -161-R Microscope shown with SO-331 Floor stand
Issue number 1.0 X:\Current User Manuals\SO-161-R User Manual v1.0.doc
SO-161-R Ophthalmic Microscope User Manual Page 5 of 18
PARTS LIST
MAIN ASSEMBLIES
Power supply assembly includes power supply mounted on G-clamp/pillar
assembly and safety clamp
Articulated Arm Assembly includes horizontal arm and adjustable pantograph arm
Microscope Assembly includes tilt adjuster, microscope head, guide handle,
lamphouse, universal arm and cable
CABLES
Mains Cable 1
12V dc Supply (Battery) Cable 1
OTHER
Focus Knob Sterilisable Covers 2
Eyepieces 2
TOOL KIT
Spare lamp 1
Socket keys set 7: 1.5mm, 2mm, 2.5mm, 3mm, 4mm, 5mm, and 6mm
Lens Cloth 1
OPTIONAL ACCESSORIES SCAN OPTICS PART NUMBER
Floor stand (heavyweight) SO-331*
Floor stand (lightweight) SO-311
Binocular assistant microscope SO-1420
Pupillary distance setter SO-1510
Side handle
Guide handle
*Note that in SO-161-R microscopes supplied with the SO-331 floor stand, the power
supply assembly is mounted on a pillar fitting, not a G-clamp. Refer to this manual for
details.
Issue number 1.0 X:\Current User Manuals\SO-161-R User Manual v1.0.doc
SO-161-R Ophthalmic Microscope User Manual Page 6 of 18
ASSEMBLY INSTRUCTIONS
TABLE MOUNTING
1. Remove the power supply assembly from the carton, and fix it firmly to the table using the
G-clamp knob. Use hand tightening only to fix the assembly in place – use of a spanner or
pliers to tighten the screw may strip the thread or produce excessive deflection in the clamp.
2. Move the safety clamp up the pillar to the desired height of the fixed arm, and lock it in
place with the thumbscrew.
3. Remove the arm assembly from the carton and loosen the elbow lock knob to allow the
pantograph arm to rotate about the end of the fixed arm. Then place the arm on the pillar so
that it rests on the safety clamp.
4. Remove the head assembly from the carton and place the pin into the collet at the end of the
pantograph arm. Tighten the wrist lock knob under the collet to secure the head assembly in
place.
5. Connect the lamphouse cable to the socket located on the top of the power supply box.
6. Connect the mains cable to the IEC socket located on the under-side of the power supply
box. Use the cable-retaining clip to secure the plug in place. Connect the other end of the
mains cable to a reliable EARTHED mains power supply.
7. Check the setting of the voltage selector located on the under-side of the power supply box.
If necessary, change the setting to 120 or 240V as required, using a flat-head screwdriver or
coin. Severe damage to the power supply may result if this is incorrectly set.
8. Switch on the mains power supply at the mains socket. When the ON/OFF switch is
selected to ON, the power supply indicator on the switch will light up.
9. Remove the microscope eyepiece blanks from the head assembly and insert the eyepieces.
Retain the eyepiece blanks in the eyepiece packaging for when the microscope is repacked.
Do not discard the eyepiece blanks.
10. When focusing the microscope, look with the right eye through the right eyepiece first and
use the focus knob or foot control to bring a target into focus at the preferred magnification.
Then look through the left eyepiece with the left eye and adjust the dial to compensate for
any relative refractive error between the eyes.
11. Remove two focus knob covers from the bag inside the carton. Push them into position on
to the focus knobs on either side of the microscope.
CAUTION:
• Scan Optics recommend that ALL packaging materials be retained by the user in a safe
place, in case of future transit needs.
• All covers are intended to be sterilised before any operating procedures.
• The mains power supply must have a protective earth conductor. If there in no earth
conductor, or if the integrity of the earth conductor arrangement is in doubt, the equipment
must be operated from a 12Vdc power source.
Issue number 1.0 X:\Current User Manuals\SO-161-R User Manual v1.0.doc