SCAN DSA 4,DSA 4 Instructions For Use Manual

Page 1
INSTRUCTIONS FOR
INSTALLATION AND USE
SCAN DSA 4
Tested &
Beaverton
O regon U SA
OMNI-Test Laboratories, In c.
Save these instructions
January 2004
Krog Iversen & CO. A/S, DK- 5492 Vissenbjerg
Denmark
Page 2
CONTENTS
1. IMPORTANT SAFETY NOTICE ..........................................................................................................................3
1.1 Prevent Creosote Fires:......................................................................................................................................3
1.2 Prevent Over Firing:..........................................................................................................................................3
2. CAUTIONS.............................................................................................................................................................4
3. INTRODUCTION / INSTRUCTIONS FOR USE.................................................................................................5
3.1 About the SCAN DSA 4 fireplace.....................................................................................................................5
3.2 Baffle Cassette:..................................................................................................................................................5
3.3 Glass: .................................................................................................................................................................5
3.4 Smoke Detectors:...............................................................................................................................................5
3.5 Room Ventilation: .............................................................................................................................................6
3.6 Firebricks and Skamol liners:............................................................................................................................6
3.7 Ceramic gasket: .................................................................................................................................................6
3.8 Pre Installation Check List: ...............................................................................................................................6
4. INSTALLATION (Qualified technicians only) .....................................................................................................7
4.1 Fireplace size requirements ...............................................................................................................................7
4.2 Fireplace placement requirements .....................................................................................................................7
4.3 Hearth and floor protection requirements:.........................................................................................................8
4.3.1 Minimum Clearances:.................................................................................................................................8
4.4 Masonry Fireplace Requirements......................................................................................................................9
4.5 Drafting Performance ........................................................................................................................................9
4.6 Fireplace with direct connection (Masonry fireplace).......................................................................................9
4.7 Surround Panel Installation (see part numbers below)....................................................................................11
4.8 Combustion Air Supply:..................................................................................................................................11
4.9 Draft Requirements: ........................................................................................................................................12
4.10 Chemney Installation:....................................................................................................................................12
5. OPERATION ........................................................................................................................................................13
5.1 Fueling the fireplace:.......................................................................................................................................13
5.2 Starting a Fire: .................................................................................................................................................13
5.3 Refueling: ........................................................................................................................................................14
6. MAINTENANCE..................................................................................................................................................15
6.1 Ash Disposal and Removal: ............................................................................................................................15
6.2 Cleaning of fireplace: ......................................................................................................................................15
6.3 Removing Baffle Cassette for Cleaning: .........................................................................................................15
6.4 Creosote Formation and the Need for Removal: .............................................................................................16
6.5 Door Glass:......................................................................................................................................................16
6.5.1 Replacing Broken Door Glass:.................................................................................................................16
6.6 Replacement part list: ......................................................................................................................................17
6.7 Safety label:.....................................................................................................................................................17
7. WARRANTY PROVISIONS FOR SCAN WOOD BURNING PRODUCTS.....................................................18
8. TROUBLESHOOTING ........................................................................................................................................19
Page 3
Congratulations on your new SCAN DSA wood burning fireplace. We are confident that you will enjoy your new SCAN DSA fireplace, especially if you follow the instructions and advice given below.
SCAN DSA fireplaces have a number plate. In case of complaints we request that you have the registration number.
In the SCAN DSA fireplace you will find a service box containing the following items: 1 stove mitten 1 handle to operate the door 1 set of fittings for the flue collar 1 set of screws and hexagon spanners 1 bag of fire starters for the first lightning
The SCAN DSA fireplaces have been tested by OMNI-Test Laboratories, Inc. of Beaverton, Oregon, and are listed by OMNI to UL 1482, ULC S628 and EPA certified.
Please: read the entire manual before installing or operation your new fireplace.
1. IMPORTANT SAFETY NOTICE
The SCAN DSA wood-burning fireplace is a closed fireplace.
Protection against a fire hazard is of primary importance when installing a wood-burning fireplace. If utilizing an older chimney, it must be inspected for adequate serviceability. Refer to the heading: Chimney Installation (page 12).
Minimum listed clearances to combustible surfaces and materials must be maintained, including; furniture, drapers, clothing, wood, papers, etc.
1.1 Prevent Creosote Fires:
Both the chimney and chimney connector should be inspected for creosote deposits at least twice monthly during the heating season. Remove all buildups as necessary. This fireplace is approved for burning dry seasoned natural wood only. Using green or inadequately seasoned wood can greatly increase creosote buildup.
1.2 Prevent Over Firing:
Do not over-fire! Over-firing the fireplace can cause a house fire. If the fireplace glows, you are over-firing. Damage caused from over firing is not covered by the manufactures limited warranty.
Page 4
2. CAUTIONS
IF THIS FIREPLACE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESLUT. FOR YOUR SAFETY FOLLOW THESE INSTALLATION INSTRUCTIONS. CONTACT YOUR LOCAL BUILDING DEPARTMENT ABOUT RESTRICTIONS AND INSTALLATIONS INSPECTION IN YOUR AREA.
KEEP START DEVICE CLOSED DURING FIRING OF THIS FIREPLACE, START DEVICE MAY BE OPENED FOR A MAXIMUM OF 5 MINUTES DURING FIRE STARTUP.
NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO START OR “FRESHEN UP” A FIRE IN THIS FIREPLACE KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE FIREPLACE WHILE IT IS IN USE.
DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL.
THIS FIREPLACE IS HOT WHILE IN OPERATION, DO NOT TOUCH, AND KEEP CHILDREN AWAY. CONTACT MAY CAUSE SKIN BURNS. USE GLOVES WHEN STOKING THE FIRE.
DO NOT CONNECT THIS FIREPLACE TO A CHIMNEY FLUE CONNECTED TO ANOTHER FIREPLACE, STOVE OR APPLIANCE.
DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
DO NOT INSTALL IN A MOBILE HOME.
BE SURE TO ALLOW AN ADEQUATE SOURCE OF FRESH AIR INTO THE ROOM WHERE THE FIREPLACE IS OPERATING (SEE ROOM VENTILATION PAGE 6 AND COMBUSTION AIR SUPPLY PAGE 12).
DO NOT OPERATE THE FIREPLACE WITHOUT THE FIREBOX BAFFLE CASSETTE PROPERLY INSTALLED.
BUILD FIRES DIRECTLY UPON THE HEARTH INSIDE THE FIREPLACE. DO NOT USE GRATES, IRONS OR ANY OTHER METHOD TO ELEVATE THE FIRE.
THE SCAN DSA 4 FIREPLACE IS ONLY FOR FIREPLACE INSTALLATION.
Page 5
3. INTRODUCTION / INSTRUCTIONS FOR USE
3.1 About the SCAN DSA 4 fireplace
SCAN DSA 4:
CAUTION:
Do not operate the fireplace with the start device open or ajar, as this will produce extreme temperatures within the fireplace (over-firing), which could result in a house fire. Damage caused by over firing is not covered by the manufacturers limited warranty
3.2 Baffle Cassette:
The SCAN DSA 4 has a baffle cassette assembly that must be installed in the upper firebox. When in the proper position, the lower plate should lay on top of the air manifold and against the rear wall of the firebox. See the maintenance section of this manual
for additional information on removing baffle cassette for cleaning and for drawings of the firebox inclusive of baffle cassette of SCAN DSA fireplace (see page 16).
A ceramic baffle cassette is delivered with all SCAN DSA fireplaces. When mounting a baffle cassette it must be done according to the description in section 6: Removing baffle cassette for cleaning. Make sure that it is placed symmetrically in the stove, i.e. with even amounts of free air space on each side.
We recommend that you treat the ceramic baffle cassette (Skamol) with caution because it is a delicate material (not covered by the limited warranty). It is extremely heat resistant.
3.3 Glass:
The glass is a heat resistance ceramic glass that can withstand continuous temperatures up to 1390°F (754°C). This temperature is well beyond the temperatures in which you operate your insert.
This fireplace is designed to provide a flow of air over the inside of the glass. This air combined with high temperatures helps keep it optimally clean when the combustion air intake is fully opened. When operating the insert on low for extended periods of time, the glass may become dirty. A short, hot fire will help clean off much of the normal buildup (see section 8: Troubleshooting). In order to keep the glass soot free, the moisture content of the wood must be between 15 and 18% on a wet basis.
3.4 Smoke Detectors
:
Since there are always several potential sources of fire in any home, we recommend installing smoke detectors. Do not install them too close to the fireplace as heat can activate them.
Page 6
3.5
Room Ventilation:
During the combustion, oxygen taken from the room air is used. In rare cases it may be necessary to mount a fresh-air duct near the fireplace.
3.6 Firebricks and Skamol liners:
Little cracks may arise in the firebricks and Skamol liners because of a minor content of water, especially if the fireplace is overheated during the first firing. These cracks do not influence the workability of the insert and are not covered by the limited warranty.
3.7 Ceramic gasket:
The SCAN DSA fireplaces are equipped with ceramic gasket to ensure the tightness of the door and the glass. This ceramic gasket is a wearing part and must be changed from time to time. Please consult your authorized dealer in this case.
FIREPLACE INSTALLATION MUST BE SAFE AND LEGAL!
SAFETY NOTICE:
IF YOUR DSA FIREPLACE IS NOT PROPERLY INSTALLED, OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW ALL INSTALLATION AND MAINTENANCE DIRECTIONS. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION REQUIREMENTS IN YOUR AREA.
3.8 Pre Installation Check List:
Before you begin an installation, review your plans, check to see:
1. Your fireplace and chimney connector will be far enough from combustible material to meet all clearance requirements.
2. The floor protection is large enough and is constructed properly to meet all requirements.
3. You have all necessary permits from local authorities. Your local building official is the final authority for approving your installation as safe and determining that it meets local and state codes.
The metal label permanently attached to the left side of every SCAN DSA fireplace shows that it has been tested to current UL and ULC standards, and gives the name of the testing laboratory. Clearance and installation information is also printed on the label. Local authorities will generally accept the label as evidence that, when the fireplace is installed according to the information on the label and in this manual, the installation meets codes and can be approved.
Codes vary in different areas. Before starting the installation, review your plans with the local building authority. Your local dealer can provide any additional information needed.
For any unresolved questions about installation in the USA, refer to the national Fire Protection Association’s publication ANSI/NFPA 211-1996
Standard for Chimneys, Fireplaces, Vents and
Solid Fuel Burning Appliances.
For installation in Canada, refer to CSA CAN-B365,
Installation
Code for Solid Fuel Burning Applications and Equipment
. These standards are the basis for many national codes. They are nationally recognized and are accepted by most local authorities. Your local dealer or your local building official may have a copy of these regulations.