SCAN 85-1,85-2,85-4,85-5,85-3,85-6,85-7,85-8 Assembly And Instruction Manual

SCAN A/S - DK-5492 VISSENBJERG
Scan 85 series
ASSEMBLY- AND INSTRUCTIONS MANUAL
Congratulations on your new Scan wood-burning stove
You have purchased a product by one of Europe’s leading manufacturer’s of wood-burning stoves, and we are sure that you will have years of plea-
sure with your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions.
Please read this Assembly- and instructions manual before you start to assemble your stove.
Please indicate the product registration number at any enquiry
2
CONTENTS
Table of contents
Technical data .............................................................................................. 3
Installation Safety Technical data and dimensions Dimension sketch Type plate Loose parts Additional accessories
Assembly ........................................................................................................ 7
Remove packaging Handles Product registration number Positioning your wood-burning stove Positioning near to non-flammable materials Distance to furniture Distance to flammable materials Load bearing foundation Floor plate Existing chimney and pre-fabricated element chimney Connection between stove and steel chimney Requirements for chimney Connection with 90° elbow pipe Adjustment screws Connection piece / top outlet Connection piece / rear outlet Height adjustment of top module Fresh air intake Closed combustion system Ash container Heat-storage stone
Instruction for use ................................................................................... 20
CB technique Primary air Secondary air Baffle plates Ash container Handle for riddling grate
Instructions for heating .......................................................................... 21
Lighting Handling fuel
Maintenance .............................................................................................. 23
Servicing ...................................................................................................... 24
Troubleshooting ........................................................................................ 27
TECHNICAL DATA
3
Installation
The house owner is responsible for ensuring that all necessary natio­nal and local safety measures are observed during installation and fitting and also responsible for observing the fitting and operating instructions detailed in this manual.
When you install any kind of fireplace or stove, you must inform the local authorities. You are also responsible for calling in a chimney sweep to inspect and authorize the installation.
To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Our Scan Dealer will be able to recommend a qualified fitter in your area. For information on Scan Dealers, please go to www.scan.dk.
Safety
Any changes made to the product by the dealer, installer or user could result in the product and safety functions not functioning as intended. The same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case if parts that are necessary for the operation and safety of the stove are dismantled or removed.
The Scan 85 series comprises:
Scan 85-1: Stove with handles and trims in black aluminium
Scan 85-2: Stove with handles and trims in brushed aluminium
Scan 85-3: Stove Maxi with handles and trims in black aluminium
Scan 85-4: Stove Maxi with handles and trims in brushed aluminium
Scan 85-5: Stove High Top with handles and trims in black aluminium
Scan 85-6: Stove High Top with handles and trims in brushed aluminium
Scan 85-7: Stove High Base with handles and trims in black aluminium
Scan 85-8: Stove High Base with handles and trims in brushed aluminium
Scan 85-1/2
Scan 85-3/4
Scan 85-5/6
Scan 85-7/8
* Height to the begin­ ning of the connecting piece at top outlet
** Centre rear outlet
*** Centre of fresh air intake rear
**** Centre of fresh air in­ take bottom
* Height to the begin­ ning of the connecting piece at top outlet
** Centre rear outlet
*** Centre of fresh air intake rear
**** Centre of fresh air in­ take bottom
TECHNICAL DATA
4
Dimension sketch Scan 85-1 + Scan 85-2
520
1464
260
260****
112***
1347**
1442*
Dimension sketch Scan 85-3 + Scan 85-4
260
1864
520 260****
1547**
112***
1642*
260****
1347**
112***
1442*
* Height to the begin­ ning of the connecting piece at top outlet
** Centre rear outlet
*** Centre of fresh air intake rear
**** Centre of fresh air in­ take bottom
* Height to the begin­ ning of the connecting piece at top outlet
** Centre rear outlet
*** Centre of fresh air intake rear
**** Centre of fresh air in­ take bottom
TECHNICAL DATA
5
Dimension sketch Scan 85 Maxi
Dimension sketch Scan 85-5 + Scan 85-6
1664
260****
260
1347**
112***
1442*
520
Dimension sketch Scan 85-7 + Scan 85-8
1664
520
1547**
112***
1642*
260****
260
TECHNICAL DATA
6
Type plate
All Scan wood-burning stoves are fitted with a type plate, that speci­fies the approval standards and the distance to flammable materials.
Additional accessories
Large shaped floor plate in steel (not for corner installa­ tion)
Large base floor plate in glass (not for corner installation)
Small shaped floor plate in glass or steel (not for corner installation)
Heat-storage stone Scan 85-3, 85-4, 85-5 og 85-6
Scan 85-Series
Freestanding room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 90585600
Wood
Intermittent
EUR
Norway
Austria
Classification
Intermittent
Klasse 2
Certificate/Standard
EN 13240 300-ELAB-1381-NS 300-ELAB-1381-ØS
Approved by Teknologisk Institut Teknologisk Institut Teknologisk Institut
Dust at 13% O2: 7 mg/Nm³ Flue gas temperature: 272°C Nominal heat output: 8 kW Efficiency: 78%
Angaben für Österreich
Wärmeleistungsbereich: 4,0 - 8,0 kW Brennstoffwärmeleistung: 8 kW Zulässige Brennstoffe: Scheitholz
Prüfbericht:
Teknologisk institut
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials:
Side: 600 mm - Back: 100 mm - Top: 600 mm - Front: 1000 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels. Montage- und Bedienungsanleitung beachten. Verwenden Sie nur empfohlene Brennstoffe.
1000 03-2014
0,06% 801 mg/Nm³
Schweiz
Germany
LRV 11
BStV 1
VKF Nr. 22520
300-ELAB-1381-EN
Teknologisk Institut
Teknologisk Institut
Technical data and dimensions
Materials: ..................................... Steel plate, cast iron, galvanised sheet,
skamolex, chamotte
Surface treatment: ........................................................................... Senotherm
Max. log length when heating with horizontal logs: .................... 30 cm
Max. log length when stoking with vertical logs: ........................... 50 cm
Weight Scan 85: ..........................................................................204 kg - 220 kg
Connecting piece internal diameter: ............................................... 144 mm
Connecting piece external diameter: .............................................. 148 mm
Approval type: ................................................................ Intermittent fuelling
Test in compliance with EN 13240
CO Emission at 13% O2: .................................... 0,06% ............ 801 mg/Nm3
Dust @ 13% O2: ................................................................................... 7 mg/Nm
3
Nox @ 13% O2: .................................................................................. 87 mg/Nm
3
Efficiency: .......................................................................................................... 78%
Nominel output: ........................................................................................... 8 kW
Chimney temperature EN 13240: .......................................................... 272 °C
Amount of smoke: ................................................................................. 7,8 g/sek
Sub-pressure EN 13240: ............................................................................... 12 Pa
Recommended sub-pressure in connecting piece: .................... 18-20 Pa
Required combustion air supply: ................................................ 27,1 Nm3/h
Fuel: .................................................................................................................. Wood
Fuel consumption: ................................................................................. 2,5 kg/h
Amount of fuel: ............................................................................................ 2,2 kg
Intermittent fuelling means normal use of a woodstove. In other words, you should let the fire die down until only the embers are left, before refuelling.
Scan 85 series was build in compliance with the homologized product type specified in the Assembly- and Instructions Manual provided with the product.
The DoP declaration of Performance is available from http://scan.dk
Loose parts
The flue connection piece and other loose parts are located in the stove’s combustion chamber.
Scan 85, all types:
x4 screws for fastening flue connection piece
Gasket for flue connection piece
• Glove
Repair lacquer for coloured stoves
A
A
ASSEMBLY
7
Inspection hatch
Remove packaging
Check that the stove is not damaged before installing it.
The Scan 85 serie are fixed onto the pallet when they are delivered. The four screws securing the stove may be removed through the two inspection hatches in the base.
Screws to be removed
Inspection hatches
Lift the inspection hatches free from their mounts.
Remove the inspection hatches from the stove.
Remove the screws that securing the stove to the pallet.
ASSEMBLY
8
Product registration number
Product registration number
All Scan wood-burning stoves are provided with a product registra­tion number. The product registration number is located at the rear of the stove.
Please make a note of this number at the frontpage; you will always need to quote it when contacting your dealer or Scan A/S.
Handle release
Handles
To open the door of the Scan 85 series, press the handle release. The handle will pop out and the door can be opened.
Type plate
100
600
100
100
5
09
ASSEMBLY
9
Distance to flammable materials
Positioning your wood-burning stove
The wood-burning stove must be set up so that the stove itself, the flue pipe, and the chimney can all be cleaned.
Position near to non-flammable walls
When positioning near a non-flammable wall, we recommend you keep a minimum distance of 50 mm between the rear of the product and the wall for cleaning purposes.
Distance to furniture: 1000 mm
But please check to avoid furniture or other furnishings being dried out due to being too close to the stove.
Parallel rear wall installation
45° Corner installation
Brændbart materiale
600
Flammable material
Loading...
+ 19 hidden pages