SCAN 68-7, 68-8, 68-9, 68-10, 68-11 Assembly And Instruction Manual

...
UK – Scan 68
ASSEMBLY AND INSTRUCTION MANUAL SCAN 68
CONGRATULATIONS ON YOUR NEW SCAN WOOD-BURNING STOVE
You have purchased a product by one of Europe’s leading manufacturers of wood-burning stoves, and we are sure that you will have years of pleasure from your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions.
Scan 68-1
Wall hung model Without side windows Black mouldings
Scan 68-2
Wall hung model Without side windows Aluminium mouldings
Scan 68-3
Pedestal Without side windows Black mouldings
Scan 68-4
Pedestal Without side windows Aluminium mouldings
Scan 68-5
Portal Without side windows Black mouldings
Scan 68-6
Portal Without side windows Aluminium mouldings
Scan 68-7
Wall hung model With side windows Black mouldings
Scan 68-8
Wall hung model With side windows Aluminium mouldings
Scan 68-9
Pedestal With side windows Black mouldings
Scan 68-10
Pedestal With side windows Aluminium mouldings
Scan 68-11
Portal With side windows Black mouldings
Scan 68-12
Portal With side windows Aluminium mouldings
Scan 68-13 LB
Low Base Without side windows Black mouldings
Scan 68-14 LB
Low Base Without side windows Aluminium mouldings
Scan 68-13
Steel sides Without side windows Black mouldings
Scan 68-14
Steel sides Without side windows Aluminium mouldings
Scan 68-13 HT
High Top Without side windows Black mouldings
Scan 68-14 HT
High Top Without side windows Aluminium mouldings
Scan 68-15 LB
Low Base Without side windows Black mouldings
Scan 68-16 LB
Low Base Without side windows Aluminium mouldings
Scan 68-15
Soapstone Without side windows Black mouldings
Scan 68-16
Soapstone Without side windows Aluminium mouldings
Scan 68-15 HT
High Top Soapstone Without side windows Black mouldings
Scan 68-16 HT
High Top Soapstone Without side windows Aluminium mouldings
SCAN 68-SERIEN
TABLE OF CONTENTS
¬
MOUNTING THE UK-SCREW 43
¬
TECHNICAL DATA 4
Installation ....................................................................................... 4
Safety ................................................................................................. 4
Technical data and dimensions ................................................. 4
Dimension ......................................................................................... 5
Type plate........................................................................................11
Product registration number ...................................................12
¬
ASSEMBLY 12
Additional accessories ...............................................................12
Loose parts.....................................................................................12
Disposal of packaging ................................................................12
Removal of packaging ................................................................13
Mounting of the burn chamber on the pedestal basel ....14
Mounting of the burn chamber on the portal basel .........15
Mounting of the door assembly ..............................................16
Mounting of Wall-hung model ..................................................17
Mounting of the wall fitting on the stove ............................18
Removal of the self-closing door spring..............................21
Mounting of external air supply on the wall fitting .........21
Fitting natural stone ...................................................................22
Mounting of high top ...................................................................23
High Top for natural stone ........................................................23
Wall mounting kit for Scan 68 with high top ......................24
Heat-storage stone .....................................................................25
Height adjustment of stove ......................................................26
Connecting piece ..........................................................................26
Existing chimney and pre-fabricated element chimney .27
Connection between stove and steel chimney ..................27
Requirements for chimney .......................................................27
Connection with 90° elbow pipe .............................................27
Load-bearing subsurface ..........................................................28
Floor plate ......................................................................................28
Positioning your wood-burning stove ...................................28
Distance to furniture ..................................................................28
Distance to flammable materials, ..........................................29
Distance to firewall .....................................................................30
¬
INSTRUCTIONS FOR USE 31
CB technology (Clean Burning) ................................................31
Primary air ......................................................................................31
Secondary air .................................................................................31
Baffle plates ..................................................................................31
Ash container .................................................................................31
The Clean Air Act 1993 and Smoke Control Areas ..........31
Refueling on to a low fire bed ..................................................32
Warning about over-firing .........................................................32
Operation with door left open .................................................32
Dampers left open .......................................................................32
Fresh air intake .............................................................................33
Closed combustion system ......................................................33
¬
INSTRUCTIONS FOR HEATING 34
Environmentally-friendly firing ..............................................34
Lighting ............................................................................................34
“Top down” lighting.......................................................................34
Continuous firing ..........................................................................35
Firing in the spring or autumn ..................................................35
The function of the chimney .....................................................35
Using your stove in various weather conditions ...............35
General notes ................................................................................35
Chimney fire ...................................................................................35
¬
HANDLING FUEL 36
Selecting wood/fuel ....................................................................36
Preparation ....................................................................................36
Storing .............................................................................................36
Moisture ..........................................................................................36
Use of the following as fuel is illegal ....................................36
Calorific value of the wood .......................................................36
¬
MAINTAINANCE 37
¬
TROUBLESHOOTING 40
¬
WARRANTY 41
¬
NOTES 42
4
TECHNICAL DATA AND DIMENSIONS
Materials
Steel plate
Cast iron
Galvanised sheet
Vermicolite
Surface treatment Senotherm
Max. wood length ca. 33 cm
Weight Scan 68-1/2/7/8 ca. 98 kg
Weight Scan 68-3/4/9/10 ca. 105 kg
Weight Scan 68-5/6/11/12 ca. 107 kg
Weight Scan 68-13/14 ca. 110 kg
Weight Scan 68-13/14 LB ca. 100 kg
Weight Scan 68-15/16 ca. 190 kg
Weight Scan 68-15/16 LB ca. 170 kg
Connecting piece internal diameter 144 mm
Connecting piece external diameter 148 mm
Approval type Intermittent fuelling*
Intermittent operation in this context means normal use of a wood-burning stove. In other words, you should let the fire die down until only the embers are left before refueling.
This stove is produced in accordance with type approval for the product, which also covers the product’s Assembly and Instruction Manual.
The Declaration of Performance (DoP) is available from www.scan.dk
*
PLEASE NOTE!
You get the best use of the stove
by using a top-down lighting.
See "instruction for heating"
TECHNICAL DATA
INSTALLATION
¬ The house owner is responsible for ensuring that installation and assembly are in accordance with national and local
building regulations as well as the information provided in this Assembly and Instruction Manual.
¬ When you install any kind of fireplace or stove, you must inform the local building and housing authorities. In addition
you are obliged to have the installation inspected and approved by a local chimney sweep prior to commissioning.
¬ To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Your
Scan Dealer will be able to recommend a qualified fitter in your area. For information on Scan Dealers, please go to www.scan.dk.
SAFETY
Any changes made to the product by the dealer, fitter or user could result in the product and safety functions not func­tioning as intended. The same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case if parts that are necessary for the operation and safety of the stove are dismantled or removed.
Test in compliance with EN 13240
CO Emission at 13% O
2
0,04 %
CO Emission at 13% O
2
556 mg/Nm
3
Dust @ 13% O
2
14 mg/Nm
3
Nox @ 13% O
2
85 mg/Nm
3
Efficiency 79 %
Energy efficiency index 105,6
Energy efficiency class A
Nominel output 5 kW
Chimney temperature EN 13240 265 °C
Amount of smoke 5,3 g/sek
Sub-pressure EN 13240 12 Pa
Recommended sub-pressure in connecting piece
17 Pa
Required combustion air supply 16,2 m
3
/h
Fuel Wood
Fuel consumption 1,6 kg/h
Amount of fuel 1,4 kg
Test in compliance with EN 13240 in smoke restricted areas
Efficiency 80 %
Energy efficiency index 107
Energy efficiency class A+
Nominel output 5,5 kW
1272
500
192
179
371
611 0*
326***
1255**
350
130*** 220***
250***
794
500
400
371
221
179
400
776**
681*
250***
794
500
400
371
776
681
250
B A
C
1272
500
611 0
326
1255
350
130 220
250
B A
C
C
5
DIMENSION SKETCH SCAN 68-3, 68-4, 68-9 AND 68-10 (PEDESTAL)
DIMENSION
A
Centre rear outlet
B
Height to the beginning of the connecting piece at top outlet
C
Centre of fresh air intake
All measurements are in millimeters
A
Centre rear outlet
B
Height to the beginning of the connecting piece at top outlet
C
Centre of fresh air intake
All measurements are in millimeters
SCAN 68-1, 68-2, 68-7 AND 68-8 (WALL HUNG MODEL)
1222
500
250***
371
192
179
1110*
1205**
350
175***
1110
1205
350
175
1222
500
250
1110
1205
350
175
B A
C
C
6
DIMENSION SKETCH SCAN 68-5, 68-6, 68-11 AND 68-12 (PORTAL)
A
Centre rear outlet
B
Height to the beginning of the connecting piece at top outlet
C
Centre of fresh air intake
All measurements are in millimeters
1222
500
371
192
179
1110*
1205**
219***
147***
276***
250***
1110
1205
219
147
276
1222
500
1110
1205
219
147
276
250
B A
C
C
C
500
250***
3
7
1
1
7
9
1
9
2
1
0
0
0
8
8
9
*
9
8
3
*
*
147***
219***
8
8
500
250
1
0
0
0
8
8
9
9
8
3
147
219
8
8
B A
C C
7
DIMENSION SKETCH 68-13 AND 68-14 (STEEL SIDES)
DIMENSION SKETCH SCAN 68-13 AND 68-14LB (LOW BASE)
A
Centre rear outlet
B
Height to the beginning of the connecting piece at top outlet
C
Centre of fresh air intake
All measurements are in millimeters
A
Centre rear outlet
B
Height to the beginning of the connecting piece at top outlet
C
Centre of fresh air intake
All measurements are in millimeters
1650
371
276
1110*
1205**
250***
147***
179
192
366
1650
276
1110
1205
250
147
366
B A
C
C
8
DIMENSION SKETCH SCAN 68-13 AND 68-14 HT (HIGH TOP)
A
Centre rear outlet
B
Height to the beginning of the connecting piece at top outlet
C
Centre of fresh air intake
All measurements are in millimeters
1
2
5
7
586
3
7
1
1
9
2
1
7
9
1
2
0
5
1
1
1
0
2
7
6
147
219
1
2
5
7
586
1
2
0
5
1
1
1
0
2
7
6
147
219
B A
C
C
500
250***
3
7
1
1
7
9
1
9
2
1
0
0
0
8
8
9
*
9
8
3
*
*
147***
219***
8
8
1
0
3
5
586
294
219
147
8
8
889
983
B A
C
C
9
DIMENSION SKETCH SCAN 68-15 AND 68-16 (SOAPSTONE)
DIMENSION SKETCH SCAN 68-13 AND 68-14 (SOAPSTONE + LOW BASE)
A
Centre rear outlet
B
Height to the beginning of the connecting piece at top outlet
C
Centre of fresh air intake
All measurements are in millimeters
A
Centre rear outlet
B
Height to the beginning of the connecting piece at top outlet
C
Centre of fresh air intake
All measurements are in millimeters
1
6
8
5
586
1
2
0
5
1
1
1
0
2
7
6
147
219
3
7
1
1
9
2
1
7
9
1
6
8
5
586
1
2
0
5
1
1
1
0
2
7
6
147
219
B A
C
C
C
10
DIMENSION SKETCH SCAN 68-15 AND 68-16 HT (SOAPSTONE + HIGH TOP)
A
Centre rear outlet
B
Height to the beginning of the connecting piece at top outlet
C
Centre of fresh air intake
All measurements are in millimeters
Scan 68-7 and 68-8
Wall mounted room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 90068601
Wood
Intermittent
EUR Norway Austria
Classification
Intermittent
15a B-VG
Certificate/Standard
EN 13240
NS 3058
ELAB-2100-AUS
Approved by Teknologisk Institut Teknologisk Institut Teknologisk Institut
Dust at 13% O2: 14 mg/Nm³ Flue gas temperature: 265°C Nominal heat output: 5,5 kW Efficiency: 80%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials Do not install on combustible materials Side: 500 mm - Front: 950 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels. Montage- und Bedienungsanleitung beachten.
1000 04-2015
0,04% 556 mg/Nm³
Schweiz
Germany
LRV 11 Stufe 2
VKF
1. BlmSchV
Scan 68-3-4-5-6-13-14-15-16
Freestanding room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 90068602
Wood
Intermittent
EUR
Norway
Austria
Classification
Intermittent
15a B-VG
Certificate/Standard
EN 13240
NS 3058
ELAB-2100-AUS
Approved by Teknologisk Institut Teknologisk Institut Teknologisk Institut
Dust at 13% O2: 14 mg/Nm³ Flue gas temperature: 265°C Nominal heat output: 5,5 kW Efficiency: 80%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials
Side: 400 mm - Back: 150 mm - Front: 1100 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels. Montage- und Bedienungsanleitung beachten.
1000 04-2015
0,04% 556 mg/Nm³
Schweiz
Germany
LRV 11 Stufe 2
VKF
1. BlmSchV
Scan 68-1 and 68-2
Wall mounted room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 90068600
Wood
Intermittent
EUR
Norway
Austria
Classification
Intermittent
15a B-VG
Certificate/Standard
EN 13240
NS 3058
ELAB-2100-AUS
Approved by Teknologisk Institut Teknologisk Institut Teknologisk Institut
Dust at 13% O2: 14 mg/Nm³ Flue gas temperature: 265°C Nominal heat output: 5,5 kW Efficiency: 80%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials Do not install on combustible materials Side: 400 mm - Front: 1100 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels. Montage- und Bedienungsanleitung beachten.
1000 04-2015
0,04% 556 mg/Nm³
Schweiz
Germany
LRV 11 Stufe 2
VKF
1. BlmSchV
Scan 68-9-10-11-12
Freestanding room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 90068603
Wood
Intermittent
EUR Norway Austria
Classification
Intermittent
15a B-VG
Certificate/Standard
EN 13240
NS 3058
ELAB-2100-AUS
Approved by Teknologisk Institut Teknologisk Institut Teknologisk Institut
Dust at 13% O2: 14 mg/Nm³ Flue gas temperature: 265°C Nominal heat output: 5,5 kW Efficiency: 80%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials
Side: 500 mm - Back: 150 mm - Front: 950 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels. Montage- und Bedienungsanleitung beachten.
1000 04-2015
0,04% 556 mg/Nm³
Schweiz
Germany
LRV 11 Stufe 2
VKF
1. BlmSchV
11
TYPE PLATE
All Scan wood-burning stoves are fitted with a type plate that specifies the approval standards and the distance to flam­mable materials.
The type plate is located at the rear of the stove.
Typeplates
6800000
12
PRODUCT REGISTRATION NUMBER
All Scan wood-burning stoves are provided with a product registration number. You will always need to quote this number when contacting your dealer or Scan A/S.
The product registration number is located at the rear of the stove.
ADDITIONAL ACCESSORIES
¬ Small shaped floor plate in glass or steel ¬ High Top (Scan 68-13/14)
¬ Large shaped floor plate in glass or steel ¬ High Top (Scan 68-15/16)
¬ Storage door for the Portal unit. ¬ Heat accumulating stones for high top
¬ Connecting piece for inside flue pipe, 6" ¬ Wall mounting kit for Scan 68 with high top
LOOSE PARTS
¬ Glove ¬ Dekor ring for top outlet
¬ Connecting piece 6" ¬ 4 Screw M5 x 10 mm
¬ Seal ¬ 1 Pass Screw M5 x 10 mm (UK) - Please see instructions
DISPOSAL OF PACKAGING
Your Scan stove may come supplied with the following packaging:
Wood packaging Wood packaging: after final use can be incinerated as a CO2 neutral product or sent for recycling
Flamingotop Send for recycling or waste disposal
Foam Send for recycling or waste disposal
Plastic bags Send for recycling or waste disposal
Stretch/plastic film Send for recycling or waste disposal
ASSEMBLY
Type plate
Product registration number
Product registration number
B
41
2
3
5
13
REMOVAL OF PACKAGING
Check that the stove is not damaged before starting to install it.
Pull back and lift.
Please remove protection
The plastic plugs are mounted in the transport safety holes.
Remove the two screws in the wood compartment and lift the stove off the pallet.
A ( 1 : 5 )
A ( 1 : 5 )
A ( 1 : 5 )
1 2
14
The stove is delivered with the screws mounted. These must be removed before mounting the base.
MOUNTING OF THE BURN CHAMBER ON THE PEDESTAL BASEL
When the stove has been placed on the base, the four screws must be remounted.
Loading...
+ 30 hidden pages