SCAN 68-16,68-13,68-12,68-11,68-15,68-10,68-9,68-8,68-7,68-6,68-5,68-14,68-4,68-3,68-2,68-1 Assembly And Instruction Manual

SCAN A/S - DK-5492 VISSENBJERG
Congratulations on your new Scan wood-burning stove
You have purchased a product by one of Europe’s leading manufacturer’s of wood-burning stoves, and we are sure that you will have years of pleasure
with your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions.
Please read this Assembly- and instructions manual before you start to assemble your stove.
Product registration number
Please indicate the product registration number at any enquiry
ASSEMBLY- AND INSTRUCTIONS MANUAL
GB
2
Table of contents
Technical data ........................................................................................................ 3
Installation Safety Technical data and dimensions Dimension sketch Product registration number Type plate
Assembly ................................................................................................................10
Additional accessories Service box Loose parts Remove packaging Removal of the self-closing door spring Mounting of the base/wall fitting Load bearing foundation Floor plate Positioning your wood-burning stove Distance to furniture Distance to flammable materials, shown with un-insulated flue pipe Distance to flammable materials, shown with insulated flue pipe Distance to firewall Height adjustment of stove Existing chimney and pre-fabricated element chimney Connection between stove and steel chimney Requirements for chimney Connection with 90° elbow pipe Connecting piece / top outlet Connecting piece / rear outlet Fresh air intake Closed combustion system Fitting the natural stones/
Accessories ..........................................................................................................27
High Top Heat accumulating stones
Instruction for use ..............................................................................................31
CB technique Primary air Secondary air Baffle plates Ash drawer High Top
Instructions for heating ................................................................................... 32
Lighting Handling fuel
Maintenance .........................................................................................................34
Burn chamber
Troubleshooting .................................................................................................. 38
Important - Mounting the UK screw...............................................................39
CONTENTS
3
Installation
The house owner is responsible for ensuring that all necessary national and local safety measures are observed during installation and fitting and also responsible for observing the fitting and operating instructions detailed in this manual.
When you install any kind of fireplace or stove, you must inform the local authorities. You are also responsible for calling in a chimney sweep to inspect and authorize the installation.
To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Our Scan Dealer will be able to recommend a qualified fitter in your area. For information on Scan Dealers, please go to http://scan.dk.
Safety
Any changes made to the product by the dealer, installer or user could result in the product and safety functions not functioning as intended. The same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case if parts that are necessary for the operation and safety of the stove are dismantled or removed.
TECHNICAL DATA
68-1 Wall 68-2 Wall 68-3 Pedestal 68-4 Pedestal 68-5 Portal 68-6 Portal 68-13 Simple Portal 68-14 Simple Portal 68-15 Simple Portal 68-16 Simple Portal
68-7 Wall 68-8 Wall 68-9 Pedestal 68-10 Pedestal 68-11 Portal 68-12 Portal
Please note. It is possibly to choose high top, natural stones, accumul. stones and facedoor for selected models.
Scan 68 Series
Without side windows
With side windows
Natural
stones
Natural
stones
Model No. Model Aluminium Natural stones
Options
Alu Black
High
top
Face door
Heat-storage
stones
4
PedestalWall
Portal
Simple Portal Simple Portal
PedestalWall
Portal
Simple Portal
High Top
Simple Portal
High Top
TECHNICAL DATA
With lateral glass panes
With steel sides
Without lateral glass panes
5
TECHNICAL DATA
Scan 68 Technical data Unit
CO Emission at 13% O
2
0,06 %
CO Emission at 13% O
2
785 mg/Nm
3
Dust @ 13% O
2
12 mg/Nm
3
Nox @ 13% O
2
91 mg/Nm
3
Efficiency 79 %
Nominel output 5 kW
Chimney temperature EN 13240 248 °C
Amount of smoke 5,4 g/sek
Sub-pressure EN 13240 12 Pa
Recommended sub-pressure in connecting piece 17 Pa
Required combustion air supply 16,56 Nm3/h
Fuel Wood
Fuel consumption 1,6 kg/h
Amount of fuel 1,25 kg
Technical data and dimensions
Materials: .............Steel plate, cast iron, galvanised sheet, vermicolite
Surface treatment: .......................................................................... Senotherm
Max. wood length: ..................................................................................... 33 cm
Weight Scan 68-1/2/7/8 : ...........................................................ca. 98 kg
Weight Scan 68-3/4/9/10 : .........................................................ca. 105 kg
Weight Scan 68-5/6/11/12 : ........................................................ca. 107 kg
Weight Scan 68-13/14 : .................................................................ca. 110 kg
Weight Scan 68-15/16 : .................................................................ca. 190 kg
Connecting piece internal diameter: ...............................................144 mm
Connecting piece external diameter: ..............................................148 mm
Approval type: ................................................................ Intermittent fuelling
Intermittent fuelling means normal use of a woodstove. In other words, you should let the fire die down until only the embers are left, before refuelling.
The Scan 68 - series was build in compliance with the homologized product type specified in the Assembly- and Instructions Manual provided with the product.
The DoP declaration of performance is available from http://scan. dk
Test in compliance with EN 13240
Please note: You get the best use of the stove by using a ”top-down lighting”, see page 30.
794
500
400
371
221
179
400
776**
681*
250***
1272
500
192
179
371
611 0*
326***
1255**
350
130*** 22
0***
250***
6
* Centre rear outlet
** Height to the beginning of the connecting piece at top outlet
*** Centre of fresh air intake bottom
* Centre rear outlet
** Height to the beginning of the connecting piece at top outlet
*** Centre of fresh air intake bottom
Dimension sketch Scan 68-1, Scan 68-2, Scan 68-7 + Scan 68-8
Dimension sketch Scan 68-3, Scan 68-4, Scan 68-9 + Scan 68-10
TECHNICAL DATA
1110*
1205**
219***
147***
276***
1222
500
250***
371
192
179
1110*
1205**
350
175***
1222
500
371
192
179
1110*
1205**
219***
147***
276***
250***
7
* Centre rear outlet
** Height to the beginning of the connecting piece at top outlet
*** Centre of fresh air intake
* Centre rear outlet
** Height to the beginning of the connecting piece at top outlet
*** Centre of fresh air intake
Dimension sketch Scan 68-5, Scan 68-6, Scan 68-11 + Scan 68-12
Dimension sketch Scan 68-13 + Scan 68-14
TECHNICAL DATA
1257
580
1205
1110
276
147
219
1257
580
371
192
179
1205
1110
276
147
219
1650
276
1110*
1205**
250***
147***
8
***
1650
371
276
1110*
1205**
250***
147***
179
192
366
*** ***
* Centre rear outlet
** Height to the beginning of the connecting piece at top outlet
*** Centre of fresh air intake
Dimension sketch Scan 68-15 + Scan 68-16
TECHNICAL DATA
Dimension sketch Scan 68-13 HT + Scan 68-14 HT
1685
580
1205
1110
276
147
219
371
192
178
6800000
Målskitse Scan 68-15 HT + Scan 68-16 HT
***
9
******
* Centre rear outlet
** Height to the beginning of the connecting piece at top outlet
*** Centre of fresh air intake
TECHNICAL DATA
Type plates
All Scan wood-burning stoves are fitted with a type plate, that speci­fies the approval standards and the distance to flammable materials.
The type plate is located at the back of the stove.
Type plate
Product registration number
Product registration number
All wood-burning stoves are provided with a product registration number. The product registration number is located at the back of the stove.
Please make a note of this number on the front page as you will always have to state it when contacting your dealer or Scan A/S.
Important!
You have to replace the type plate with the one you received with the manual.
10
Scan 68-7 and 68-8
Wall mounted room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 90068601
Wood
Intermittent
EUR
Norway
Austria
Classification
Intermittent
15a B-VG
Certificate/Standard
EN 13240
NS 3058
ELAB-2100-AUS
Approved by Teknologisk Institut Teknologisk Institut Teknologisk Institut
Dust at 13% O2: 14 mg/Nm³ Flue gas temperature: 265°C Nominal heat output: 5,5 kW Efficiency: 80%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials Do not install on combustible materials Side: 500 mm - Front: 950 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels. Montage- und Bedienungsanleitung beachten.
1000 04-2015
0,04% 556 mg/Nm³
Schweiz Germany
LRV 11 Stufe 2
VKF
1. BlmSchV
Scan 68-3-4-5-6-13-14-15-16
Freestanding room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 90068602
Wood
Intermittent
EUR
Norway
Austria
Classification
Intermittent
15a B-VG
Certificate/Standard
EN 13240
NS 3058
ELAB-2100-AUS
Approved by Teknologisk Institut Teknologisk Institut Teknologisk Institut
Dust at 13% O2: 14 mg/Nm³ Flue gas temperature: 265°C Nominal heat output: 5,5 kW Efficiency: 80%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials
Side: 400 mm - Back: 150 mm - Front: 1100 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels. Montage- und Bedienungsanleitung beachten.
1000 04-2015
0,04% 556 mg/Nm³
Schweiz
Germany
LRV 11 Stufe 2
VKF
1. BlmSchV
Scan 68-1 and 68-2
Wall mounted room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 90068600
Wood
Intermittent
EUR
Norway
Austria
Classification
Intermittent
15a B-VG
Certificate/Standard
EN 13240
NS 3058
ELAB-2100-AUS
Approved by Teknologisk Institut Teknologisk Institut Teknologisk Institut
Dust at 13% O2: 14 mg/Nm³ Flue gas temperature: 265°C Nominal heat output: 5,5 kW Efficiency: 80%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials Do not install on combustible materials Side: 400 mm - Front: 1100 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels. Montage- und Bedienungsanleitung beachten.
1000 04-2015
0,04% 556 mg/Nm³
Schweiz
Germany
LRV 11 Stufe 2
VKF
1. BlmSchV
Scan 68-9-10-11-12
Freestanding room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 90068603
Wood
Intermittent
EUR
Norway
Austria
Classification
Intermittent
15a B-VG
Certificate/Standard
EN 13240
NS 3058
ELAB-2100-AUS
Approved by Teknologisk Institut Teknologisk Institut Teknologisk Institut
Dust at 13% O2: 14 mg/Nm³ Flue gas temperature: 265°C Nominal heat output: 5,5 kW Efficiency: 80%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials
Side: 500 mm - Back: 150 mm - Front: 950 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels. Montage- und Bedienungsanleitung beachten.
1000 04-2015
0,04% 556 mg/Nm³
Schweiz Germany
LRV 11 Stufe 2
VKF
1. BlmSchV
TECHNICAL DATA
Scan 68-7UK and 68-8UK
Wall mounted room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 90068605
Wood
Intermittent
UK
Classification
Intermittent
Certificate/Standard
EN 13240
300-ELAB-2100-EN-U
Approved by Teknologisk Institut Teknologisk Institut
Dust at 13% O2: 12 mg/Nm³ Flue gas temperature: 248°C Nominal heat output: 5 kW Efficiency: 79%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials Do not install on combustible materials Side: 500 mm - Front: 950 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels.
1000 10-2014
0,06% 785 mg/Nm³
Scan 68-9-10-11-12UK
Freestanding room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 90068607
Wood
Intermittent
UK
Classification
Intermittent
Certificate/Standard
EN 13240
300-ELAB-2100-EN-U
Approved by Teknologisk Institut Teknologisk Institut
Dust at 13% O2: 12 mg/Nm³ Flue gas temperature: 248°C Nominal heat output: 5 kW Efficiency: 79%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials
Side: 500 mm - Back: 150 mm - Front: 950 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels.
1000 10-2014
0,06% 785 mg/Nm³
Scan 68-7UK and 68-8UK
Wall mounted room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 90068605
Wood
Intermittent
UK
Classification
Intermittent
Certificate/Standard
EN 13240
300-ELAB-2100-EN-U
Approved by Teknologisk Institut Teknologisk Institut
Dust at 13% O2: 12 mg/Nm³ Flue gas temperature: 248°C Nominal heat output: 5 kW Efficiency: 79%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials Do not install on combustible materials Side: 500 mm - Front: 950 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels.
1000 10-2014
0,06% 785 mg/Nm³
Scan 68-3-4-5-6-13-14-15-16UK
Freestanding room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 90068606
Wood
Intermittent
UK
Classification
Intermittent
Certificate/Standard
EN 13240
300-ELAB-2100-EN-U
Approved by Teknologisk Institut Teknologisk Institut
Dust at 13% O2: 12 mg/Nm³ Flue gas temperature: 248°C Nominal heat output: 5 kW Efficiency: 79%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials
Side: 400 mm - Back: 150 mm - Front: 1100 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels.
1000 10-2014
0,06% 785 mg/Nm³
Scan 68-1UK and 68-2UK
Wall mounted room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 90068604
Wood
Intermittent
UK
Classification
Intermittent
Certificate/Standard
EN 13240
300-ELAB-2100-EN-U
Approved by Teknologisk Institut Teknologisk Institut
Dust at 13% O2: 12 mg/Nm³ Flue gas temperature: 248°C Nominal heat output: 5 kW Efficiency: 79%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials Do not install on combustible materials Side: 400 mm - Front: 1100 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels.
1000 10-2014
0,06% 785 mg/Nm³
Scan 68-9-10-11-12UK
Freestanding room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 DoP 90068607
Wood
Intermittent
UK
Classification
Intermittent
Certificate/Standard
EN 13240
300-ELAB-2100-EN-U
Approved by Teknologisk Institut Teknologisk Institut
Dust at 13% O2: 12 mg/Nm³ Flue gas temperature: 248°C Nominal heat output: 5 kW Efficiency: 79%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials
Side: 500 mm - Back: 150 mm - Front: 950 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels.
1000 10-2014
0,06% 785 mg/Nm³
A
A
11
Additional accessories
Small shaped floor plate in glass or steel
Large shaped floor plate in glass or steel
Storage door for the Portal unit.
Connecting piece for inside flue pipe, 6"
High Top (Scan 68-13/14)
High Top (Scan 68-15/16)
Heat accumulating stones for high top
Wall mounting kit for Scan 68 with high top
Loose parts
• Glove
Connecting piece 6"
• Seal
Dekor ring for top outlet
1 Pass Screw M5 x 10 mm (GB) - Please see page 37.
4 Screw M5 x 10 mm
Removal of the self-closing door spring
The stove is born with a spring that makes the door close automati­cally. This spring can easily be removed with a nipper.
Bottom view
Disposal of packaging
Your Scan stove may come supplied with the following packaging:
Wood packaging: The wood packaging can be reused and after final use can be incinerated as a CO2 neutral product or sent for recycling.
Flamingotop: Send for recycling or waste disposal.
Foam:Send for recycling or waste disposal.
Plastic bags: Send for recycling or waste disposal.
Stretch film/plastic film: Send for recycling or waste disposal.
Please remove protection
ASSEMBLY
B
12
ASSEMBLY
Pull back and lift.
Removal of packaging
Check that the stove is not damaged before starting to install it. Scan 68-13 and Scan 68-14 comes attached to a wooden pallet on
delivery. To remove the packaging, see the illustrations below.
Transport brackets
Check that the stove is not damaged before starting to install it.
Plaspropper fra servicepakken monteres i transportsikringshullerne.
Loading...
+ 28 hidden pages