SCAN 65-1,65-2,65-6,65-7,65-8,65-9,65-10,65-3,65-4,65-5 Assembly And Instruction Manual

SCAN A/S-DK-5492 VISSENBJERG
Product registration number
Scan 65-series
ASSEMBLY- AND INSTRUCTIONS MANUAL
Please indicate the product registration number at any enquiry
GB
Congratulations on your new Scan wood-burning stove
pleasure with your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions.
Read through this Assembly and Instruction Manual carefully before you start to assemble your stove.
2
Table of contents
Technical data ........................................................................................................ 3
Installation Safety Technical data and dimensions Dimension sketch Type plate Product registration number Additional accessories Loose parts
Assembly ................................................................................................................9
Remove packaging Positioning your wood-burning stove Distance to furniture Distance to flammable materials, shown with insulated flue pipe Distance to flammable materials, shown with un-insulated flue pipe Distance to firewall Height adjustment of stove Load bearing foundation Floor plate Existing chimney and pre-fabricated element chimney Connection between stove and steel chimney Requirements for chimney Connection with 90° elbow pipe Connecting piece / top outlet Connecting piece / rear outlet Fitting the natural stones Fresh air intake Closed combustion system Indicator for control of air supply Scan 65 open plinth
Accessories ...........................................................................................................20
Heat accumulating stones Fitting the top plate of natural stones
Instruction for use ................................................................................................21
CB technique Primary air Secondary air Baffle plates Ash drawer Handle for riddling grate
Instructions for heating ...................................................................................... 22
The Clean Air Act 1993 Lighting Handling fuel
Maintenance ........................................................................................................ 24
Troubleshooting ..................................................................................................26
CONTENTS
3
TECHNICAL DATA
Installation
The house owner is responsible for ensuring that installation and assembly are in accordance with national and local building regu­lations as well as the information provided in this Assembly and Instruction Manual.
When you install any kind of fireplace or stove, you must inform the local building and housing authorities. In addition you are obliged to have the installation inspected and approved by a local chimney sweep prior to commissioning.
To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Your Scan Dealer will be able to recommend a qualified fitter in your area. For information on Scan Dealers, please go to www.scan.dk.
The Scan 65-series consists of:
Safety
Any changes made to the product by the dealer, fitter or user could result in the product and safety functions not functioning as intended. The same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case if parts that are necessary for the operation and safety of the stove are dismantled or removed.
Scan 65-1
Steel sides
Scan 65-2
Steel sides and side windows
Scan 65-1 LB
Steel sides
Scan 65-2 LB
Steel sides and side windows
Scan 65-3
Natural stones
Scan 65-4
Natural stones and side windows
Scan 65-5
Steel sides, baking oven
Scan 65-6
Steel sides, baking oven and side windows
Scan 65-7
High Top, natural stones
Scan 65-8
High Top, natural stones and side windows
Scan 65-9
High Top, steel sides
Scan 65-10
High Top, steel sides and side windows
4
senotherm
30 cm
65-1 /2 ca. 123 kg
65-3 ca. 180 kg
65-4 ca. 168 kg
65-5/6 ca. 162 kg
65-7 ca. 258 kg
65-8 ca. 246 kg
65-9/10 ca. 162 kg
144 mm
148 mm
65-1, 65-3, 65-5, 65-7 & 65-9
0,08
975
< 20
104
82
110
A+
6
221
300
5
12
15-18
13,3
2
1,5
65-2, 65-4, 65-6, 65-8 & 65-10
0,1
1221
< 20
117
79
106
A
6
240
305
6
12
15-18
12,5
2
1,5
4
TECHNICAL DATA
Technical data Unit
CO Emission at 13% O2 %
CO Emission at 13% O2 mg/Nm3
Dust @ 13% O2 mg/Nm3
Nox @ 13% O2 mg/Nm3
Efficiency %
Energy efficiency index
Energy efficiency class
Nominel output kW
Chimney temperature EN 13240 °C
Temperature in connecting piece °C
Amount of smoke g/sek
Sub-pressure EN 13240 Pa
Recommended sub-pressure in connecting piece Pa
Required combustion air supply Nm3/h
Fuel Wood
Fuel consumption kg/h
Amount of fuel kg
Technical data Unit
CO Emission at 13% O2 %
CO Emission at 13% O2 mg/Nm3
Dust @ 13% O2 mg/Nm3
Nox @ 13% O2 mg/Nm3
Efficiency %
Energy efficiency index
Energy efficiency class
Nominel output kW
Chimney temperature EN 13240 °C
Temperature in connecting piece °C
Amount of smoke g/sek
Sub-pressure EN 13240 Pa
Recommended sub-pressure in connecting piece Pa
Required combustion air supply Nm3/h
Fuel Wood
Fuel consumption kg/h
Amount of fuel kg
Test in compliance with EN 13240
Technical data and dimensions
Materials Steel plate, cast iron,
galvanised sheet, vermicolite
Surface treatment
Max. wood length
Weight
Weight
Weight
Weight
Weight
Weight
Weight
Connecting piece internal diameter
Connecting piece external diameter
Approval type Intermittent fuelling*
*Intermittent operation in this context means normal use of a wood-burning stove. In other words, you should let the fire die down until only the embers are left before refueling.
This stove is produced in accordance with type approval for the product, which also covers the product’s Assembly and Instruction Manual.
The Declaration of Performance (DoP) is available from www.scan.dk
5
65-5, 65-6, 65-7, 65-8, 65-9 & 65-10
65-1, 65-2, 65-3 & 65-4
A-A ( 1 : 10 )
Top
Bund
1
1
3
2
490
2
1
0
*
*
*
*
7
2
1
0
1
2
*
1
1
1
1
*
*
3
8
0
1
9
0
154
1
1
4
9
0
*
*
*
A-A ( 1 : 10 )
Bund
2
1
0
*
*
*
*
7
2
1
0
1
2
*
1
1
1
1
*
*
154
9
0
*
*
*
A-A ( 1 : 10 )
Bund
154
1
1
4
9
0
*
*
*
A-A ( 1 : 10 )
Top
Bund
3
8
0
1
9
0
1
1
4
9
0
*
*
*
A-A ( 1 : 10 )
Top
Bund
1
1
4
9
2
*
*
*
3
8
2
1
9
2
A-A ( 1 : 10 )
Bund
154
1
1
4
9
2
*
*
*
A-A ( 1 : 10 )
Top
Bund
1
4
3
3
490
154
1
1
4
9
2
*
*
*
1
5
8
2
1
0
*
*
*
*
1
0
9
8
*
1
4
1
5
*
*
3
8
2
1
9
2
1433 (65-5/6 + 9/10)
1448 (65-7/8)
Bund
154
1
1
4
9
2
*
*
*
1
5
8
2
1
0
*
*
*
*
1
4
1
5
*
*
A-A ( 1 : 10 )
Top
Bund
154
1
1
4
9
2
*
*
*
3
8
2
1
9
2
65-9/10
1415** (65-5/6)
1201** (65-7/8)
1196** (65-9/10)
5
TECHNICAL DATA
Dimension sketch
* Centre rear outlet
** Height to the begin­ ning of the connecting piece at top outlet
*** Fresh air intake bottom
**** Fresh air intake at the back of the stove
6
65-1 LB & 65-2 LB
490
1
0
0
0
1
2
1
5
0
9
7
9
8
8
0
154
1
1
4
9
0
1
9
0
3
8
0
1
2
1
5
0
9
7
9
8
8
0
154
1
1
4
9
0
154
1
1
4
9
0
1
1
4
9
0
1
9
0
3
8
0
6
6
TECHNICAL DATA
* Centre rear outlet
** Height to the begin­ ning of the connecting piece at top outlet
*** Fresh air intake bottom
**** Fresh air intake at the back of the stove
Dimension sketch
* Centre rear outlet
** Height to the begin­ ning of the connecting piece at top outlet
*** Fresh air intake bottom
**** Fresh air intake at the back of the stove
Dimension sketch
6
Scan 65-1 - 65-3 - 65-5 - 65-7 - 65-9
Freestanding room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 Dop 90065600
Wood
Intermittent
EUR
Norway
Classification
Intermittent
Certificate/Standard
EN 13240
Approved by
RWE Power AG
Teknologisk Institut
Dust at 13% O2: < 20 mg/Nm³ Flue gas temperature: 300°C Nominal heat output: 6 kW Efficiency: 82%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials
Side: 350 mm - Back: 150 mm - Front: 1000 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels. Montage- und Bedienungsanleitung beachten. Verwenden Sie nur empfohlene Brennstoffe.
1000 05-2015
0,08% 975 mg/Nm³
Schweiz
Germany
RWE Power AG RWE Power AG
Scan 65-2 - 65-4 - 65-6 - 65-8 - 65-10
Freestanding room heater fired by solid fuel
Standard:
Fuel type: Operation type:
The appliance can be operated in a shared flue.
Country
EN 13240 Dop 90065601
Wood
Intermittent
EUR
Norway
Classification
Intermittent
Certificate/Standard
EN 13240
Approved by
RWE Power AG
Teknologisk Institut
Dust at 13% O2: < 20 mg/Nm³ Flue gas temperature: 305°C Nominal heat output: 6 kW Efficiency: 79%
Scan A/S DK 5492 Vissenbjerg
Minimum distance to combustible materials
Side: 500 mm - Back: 150 mm - Front: 1000 mm
CO emission at 13% O2:
Follow assembly- and instructions manual. Use only recommended fuels. Montage- und Bedienungsanleitung beachten. Verwenden Sie nur empfohlene Brennstoffe.
1000 05-2015
0,10% 1221 mg/Nm³
Schweiz Germany
RWE Power AG RWE Power AG
65-2, 65-4, 65-6, 65-8 & 65-10
65-1, 65-3, 65-5,65-7 & 65-9
6500000
7
TECHNICAL DATA
(With side windows)
(Without side windows)
Type plate
Product registration number
Type plate
All Scan wood-burning stoves are fitted with a type plate that speci­fies the approval standards and the distance to flammable materials.
The type plate is located at the rear of the stove.
Product registration number
All Scan wood-burning stoves are provided with a product registra­tion number. You will always need to quote this number when con­tacting your dealer or Scan A/S.
The product registration number is located at the rear of the stove.
7
8
TECHNICAL DATA
Additional accessories
• Small shaped floor plate in glass or steel
• Large shaped floor plate in glass or steel
• Natural stones top plate for stove with rear outlet
• Natural stones top plate for stove with top outlet
• Heat accumulating stones (Scan 65-7, 65-8, 65-9 & 65-10)
Loose parts
The loose parts are located in the stove's ash drawer.
Scan 65, all types:
• Glove
• Seal
• 4 pcs. screws for fastening the connecting piece
• 1 pcs. indicator for control of air supply
• 1 pcs. screw M5x6, must be placed for United Kingdom.
Scan 65-3 and 65-4:
• 4,5 m gasket
Scan 65-7 and 65-8:
• 7 m gasket
Disposal of packaging
Your Scan stove may come supplied with the following packaging:
WOOD PACKAGING:
The wood packaging can be reused and after final use can be inciner­ated as a CO2 neutral product or sent for recycling.
FLAMINGOTOP:
Send for recycling or waste disposal.
FOAM:
Send for recycling or waste disposal.
PLASTIC BAGS:
Send for recycling or waste disposal.
STRETCH FILM/PLASTIC FILM:
Send for recycling or waste disposal.
8
9
Screws to be removed
Remove the screws securing the stove to the pallet.
Fit the plastic plugs from the service box into the transport protection holes.
Remove the protection between the baffle plates, before taking the stove into use!
Protection for baffle plates
Put back the upper plate on the pins, as the protection pushes the plate upwards.
Pin for baffle plate
ASSEMBLY
Removal of packaging
Check that the stove is not damaged before starting to install it.
The stove comes attached to a wooden pallet on delivery.